Low Pressure Sight Glass Up to 35 bar MWP Type SG

Similar documents
RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Liquid Distributor Type RD

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Filter Driers with Replaceable Core

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

Check valve Types NRV and NRVH

Tube-in-tube heat exchanger Type HE

REFRIGERATION PRODUCTS

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

Dehydrators and Filters

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application

Thermostatic Expansion Valves Type TR 6

OIL SEPARATORS APPLICATIONS

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

DEHYDRATORS AND FILTERS

R32. Plan now, for a smooth and profitable conversion. The countdown to R32 has begun! alternative.

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Tube-in-tube heat exchanger Type HE

Copeland Scroll Condensing Units for the Food Service Market

EcoFlow Electronic Expansion System Type EES

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

Sealed Type Liquid Line and Suction Line Specifications

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

CHECK VALVES INSTALLATION

LINE COMPONENTS VALVES

Pressure switch KPU. Data sheet

Retrofit and High Glide Refrigerants

The natural solution for domestic refrigeration

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

General information on refrigerant controllers

2-STAGE SEMI-HERMETIC

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Refrigerants and lubricants

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

Bert A. McJimsey, Ph.D. Research Engineer The Trane Company Tyler, Texas. Dick Cawley, P.E. UPG Technology Team Leader The Trane Company Tyler, Texas

F Series - Refrigeration dryers

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.

Compressors, Chillers & Condensers

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

Hybrid tandem VSH with SH - R410A

CONDOR-H (horizontal) / CONDOR-V (vertical)

Reduce everything but reliability

10/4/2013. The Changing State of Refrigerants

Bulletin , March Electric Hot Gas Bypass Valves

Kirby Commander Condensing Unit

PULSE WIDTH MODULATING VALVES

Danfoss Scroll for Refrigeration MLM / MLZ

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Sensor unit MC2 with analog output for Freon gases and refrigerants

Refrigeration Supplies

Accumulators - Suction Line

HVACR Refrigeration

Danfoss scroll compressors SH- In parallel installation

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

New Panasonic Aquarea DHW. Domestic Hot Water Tanks

Product Catalog VALVES

ThermoStar Refrigeration Air Dryers

Brazed heat exchangers

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Kirby Drop-In Packaged Refrigeration Units

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

One. Save time and money Streamline your heat pump business! makes a difference.

STARBOX - CONDENSER UNITS

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

DANFOSS OPTYMA PLUS INVERTER UNITS

Maneurop reciprocating compressors

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications

Reducing Refrigerant Leakage

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

Maneurop reciprocating compressors. MT/MTZ Hz - R22 - R407C - R134a - R404A / R507A MAKING MODERN LIVING POSSIBLE

DAIKIN's Experience in the production with R32

SUSTAINABILITY WITH HIGH DANISH QUALITY

LEADERS IN LIQUID SCIENCE.

Semi-hermetic GEA Bock Compressors. Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world

Measurement Solutions for Refrigeration Technology.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Ammonia. Background on ammonia as a refrigerant

INSTRUCTIONS P01-A Danfoss Commercial Compressors March 2006

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

Brazed Plate Heat Exchanger for CO Applications

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Maneurop reciprocating compressors MT / MTZ

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Hi-Pres Cooling Products Catalogue. Product Catalogue

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Chapter 2. Alternatives to HCFCs and their Characteristics

Optimization of Cooling Systems

Transcription:

MAKING MODERN LIVING POSSIBLE Technical brochure Low Pressure Sight Glass Up to 35 bar MWP Type SG www.danfoss.com

Introduction Sight glasses are used to indicate:. The condition of the refrigerant in the liquid line of the plant. 2. The flow in the oil return line from the oil separator. 3. The moisture content in the refrigerant. The SG and SGR are mainly used to indicate the condition of the refrigerant as well as the liquid level in the receiver or the oil level in the compressor. The SGI/N and SGRI/N are equipped with sensitive indicators that reflects a colour, depending on the moisture content in the refrigerant. Available types Solder version SG: Without moisture indicator Socket SGR: Socket type without moisture indicator Flare verison Solder version Flare verison SGI: For mineral oil e.g. CFC and HCFC SGN: With HFC moisture indicator Socket Saddle SGRI: Saddle sight glass for mineral oil e.g. CFC and HCFC SGRN: Saddle sight glass with HFC moisture indicator Features Type SG / SGR Indicates lack of subcooling Indicates refrigerant deficiency Indicates liquid level in receiver Indicates oil level in compressor Flare-/solder connection or socket type Type SGI / SGRI For mineral oil e.g. CFC and HCFC Indicates too high water content in the refrigeration system Indicates lack of subcooling Indicates refrigerant deficiency Flare-/solder connection or socket type Type SGN / SGRN For HFC refrigerants Indicates too high water content in the refrigeration system Indicates lack of subcooling Indicates refrigerant deficiency Flare-/solder connection or socket type 2 DKRCC.PD.EK0.A5.02 / 520H5267 Danfoss A/S (AC-SMC / bpv), 03-20

Choice of sight glass Before choosing a sight glass with moisture indicator, the following should be considered: type of refrigerant water solubility of refrigerant the level on which a danger signal is required. Be aware that polyester oil for HFC refrigerants, e.g. R34a, R404A, R407C react with water in a hydrolysis generating acid and alcohol. The recoended levels of moisture content are usually between and 75 ppm, where hermetic compressors only tolerate very low moisture content, while semi-hermetic and other compressors normally tolerate higher moisture contents in the refrigerant. The on the sight glass indicator depends on the moisture content of the refrigerant. The values under green/ are to be considered as perfect condition meaning full protection against harmful effects from moisture. In other words, the filter drier is working perfectly. If the green starts to fade, the change has begun and the indicator should therefore be watched more carefully. If the changes to yellow it is a clear signal, that the capacity of the filter drier is exceeded and should be replaced as soon as possible. Technical data Ambient temperature 50 C +80 C Max. working pressure PS/MWP = 35 bar SGI / SGRI for mineral oil e.g. CFC and HCFC refrigerants Moisture content ppm = parts per million SGI/SGRI 25 C 43 C Mineral oil e.g. R < 50 50-0 >0 < 250 250-500 > 500 SGN / SGRN for HFC and HCFC refrigerants Moisture content ppm = parts per million SGN / SGRN 25 C 43 C R < - 20 >20 < 50 50-200 > 200 R34a < - 00 >00 < 45 45-70 >70 R404A < 20 20-70 > 70 < 25 25-00 >00 R407C < - 0 >0 < 60 60-5 >5 R507 < 5 5-60 > 60 < - 0 >0 Note: For moisture values of other refrigerants, please contact Danfoss. Danfoss A/S (AC-SMC / bpv), 03-20 DKRCC.PD.EK0.A5.02 / 520H5267 3

Ordering Monitor Type Version Connection in. Connection Code no. SG 0 Flare ext. ext. 0 0 0-0080 SG 2 SG 6 SGI 6 SGI 0 SGI 2 SGI 6 SGI 9 SGI 6 SGI 0 SGI 2 SGI 6 SGI 9 SGI 6s SGI 0s SGI 2s SGI 6s SGI 9s SGI s SGI 6s SGI 0s SGI 2s SGI 8s SGI 6s SGI 0s SGI 2s SGI 6s SGI s SGN 6 SGN 0 SGN 2 SGN 6 SGN 9 SGN 6 SGN 0 SGN 2 SGN 6 SGN 9 SGN 6s SGN 0s SGN 2s SGN 6s SGN 9s SGN s SGN s SGN 6s SGN 0s SGN 2s SGN 8s SGN 6s SGN 0s SGN 2s SGN 6s SGN s ) Can be screwed directly into the filter drier. Flare ext. ext. Flare int. ext. ) ODF ODM solder Flare ext. ext. Flare int. ext. ) ODF ODM solder 0-0086 0-0087 Mineral oil e.g. CFC and HCFC 0 0 9 9 0 0 9 9 9 9 7 / 8 7 / 8 0 0 8 8 7 / 8 7 / 8 7 / 8 7 / 8 / 8 / 8 0 0 9 9 0 0 9 9 9 9 0 0 8 8 7 / 8 7 / 8 0-0007 0-0008 0-0009 0-00 0-0028 0-002 0-00 0-0025 0-0026 0-0043 0-0034 0-0035 0-0036 0-0044 0-0047 0-0039 0-0040 0-004 0-0042 0-0045 0-025 0-026 0-0 0-028 0-0 HFC 0-06 0-062 0-063 0-065 0-066 0-07 0-072 0-073 0-074 0-075 0-08 0-082 0-083 0-084 0-085 0-086 0-087 0-09 0-092 0-093 0-095 0-020 0-0202 0-0203 0-0204 0-0206 4 DKRCC.PD.EK0.A5.02 / 520H5267 Danfoss A/S (AC-SMC / bpv), 03-20

Ordering (cont.) Type SGR ¾ SGR ¾ SGR ½ Version Pipe thread NPT NPT Connection 2 G¾ A ) ¾ NPT ½ NPT Socket type Code no. 0-0004 0-0005 0-0002 SGRI SGRI SGRI SGRI for saddle ½ - NPT 0-03 0-54 2 SGRN SGRN Sight glaas saddle Sight glaas saddle Sight glaas saddle SGRN SGRN for saddle ½ NPT 7 / 8 / 8 3 / 8 5 / 8 2 / 8 3 / 8 4 / 8 0-0006 0-55 0-059 0-056 0-057 0-058 0-067 0-068 0-069 2 SGRN SGRN for saddle M20.5 0-603 M20.5 3 / 8 0-072 ) ISO 8/ Danfoss A/S (AC-SMC / bpv), 03-20 DKRCC.PD.EK0.A5.02 / 520H5267 5

Dimensions and weights SGI / SGN flare, int. ext. SGI / SGN solder ODF ODF SGR SGI / SGN flare, ext. ext. SGI / SGN solder ODF ODM SGRI / N Type SGI/SGN 6 SGI/SGN 0 SGI/SGN 2 SGI/SGN 6 SGI/SGN 9 SGI/SGN 6 SGI/SGN 0 SGI/SGN 2 SGI/SGN 6 SGI/SGN 9 SGI/SGN 6s SGI/SGN 0s SGI/SGN 2s SGI/SGN 6s SGI/SGN 8s SGI/SGN s SGI/SGN s over size SGI/SGN 6s SGI/SGN 0s SGI/SGN 2s SGI/SGN 6s Version Flare ext. ext. Flare int. ext. ODF ODF solder ODF ODM solder L 67 82 88 04 0 46 57 59 7 75 0 9 6 6 73 73 73 0 9 6 6 L 7 9 0 2 7 7 9 0 2 SGR / 2 NPT 8 0. SGR 3 / 4 Pipe thread 23 0 0. SGR 3 / 4 NPT 3 8 0. SGRN / 2 NPT 8 0. H 28 4 4 28 28 H 6 8 2 8 8 2 6 8 2 2 2 6 8 B 9 6 9 9 Ø D Weight kg 0. 0.3 0.4 0.4 0. 0.3 0.4 0.6 0. 0. 0. 0. Danfoss A/S (AC-SMC / bpv), 03-20 DKRCC.PD.EK0.A5.02 / 520H5267 6