Linea 1.5. Linear Direct/Indirect LED

Similar documents
Linea 2.5. Linear Direct/Indirect LED

Linea 2.5. Linear Indirect LED

Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot. Standard Patterns " "

Linea 3.5. Linear Direct/Indirect LED

Grüv Flare Regressed. Recessed Linear LED

Linea 1.5. Linear Direct Wall Wash LED

Grüv Flare Regressed. Recessed Linear LED

Fino. Asymmetric Wall Mount Indirect LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Classix 6" 6" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Classix 6" 6" Round Lens Wall Wash

Performance Chart Electrical Data

Evoke 2.9" HP. 2.9" Square Downlight

Classix 6" 6" Round Lens Wall Wash

Performance Chart Electrical Data

Etch 2' x 2' Recessed LED

Evoke 2.9" HP. 2.9" Square Downlight

Performance Chart Electrical Data

Classix 6" 6" Round Adjustable C3

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke Square Downlight

Classix 6" 6" Round Adjustable C3M

Evoke Square Downlight

Hornet HP. Round Glass Downlight

Evoke Square Adjustable C3M

Hornet HP. Square Glass Downlight

Classix 6" 6" Round Lens Downlight

Evoke Square Adjustable HP

Velato. Recessed Slot Adjustable Multiples

Evoke Square Downlight

Murro HP. 3.5" Round Surface Canopy Wall Wash

Hornet HP. Recessed 4-Light Square Multiple

Evoke Round Adjustable C3

Evoke Square Adjustable HP

Hornet HP. Semi-Recessed 4-Light Square Multiple

Performance Chart Electrical Data

Performance Chart Electrical Data

Evoke Round Downlight

Essenza. Square Downlights

Essenza. Round Downlights

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Downlight

Performance Chart Electrical Data

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Cylindrix III Mini. 3.5" Round Surface Canopy

HORNET-HP-R- A14-3 3LT LED

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

LUX PENDANT DIRECT/INDIRECT

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

VESICA LINEAR SUSPENDED VES L

RECESSED Spec Guide. up to 111 lm/w performance

FULL BLEED APPLICATION SHOT RENDERING

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

RECESSED T-Bar & Drywall

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

SURFACE Spec Guide. up to 105 lm/w performance

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

M100 LED Direct/Indirect

LIGHT CHANNEL 45 COMPLETE FIXTURE

RECESSED - WITH StepLens OPTION

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

Recessed LED Wall/Slot SAE 202

LIGHT CHANNEL TRIM 1.6

M60 LED Recessed Wet Location

OLS-DI-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL SUSPENDED LINEAR DIRECT/INDIRECT SYSTEM

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

NOVA CEILING WALL GRAZER WITH REMOTE POWER

Claude Indirect Wall WALL

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

Ordering Information: 4-ASI5-LED-WDM-35K-18K-4000L-MVOLT ASI5-LED

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

DHL-LP-LED Low Profile LED Linear High/Low Bay

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

12 inches to 120 inches

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

OLS-R-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL RECESSED LINEAR DIRECT SYSTEM 2" 4"

Catalog Number. Notes

Truss Surface SURFACE

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Max 4 Flush Lens RECESSED

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

M100 My White LED Direct Tunable White

Ivalo Lumaris LED Linear Lighting

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

PURSUIT. New image to come. LiNEAR Without LIMiTation PURSUITTM

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

WARRANTY LED ECO PANEL.

M36 My White LED Direct

Transcription:

a 1.5 Features a drives your design scenario, seamlessly. Streamlined and flexible, these architectural LED pendants provide the freedom to create truly dynamic spaces. synthesis of aesthetics, performance and energy efficiency, the a family delivers on its promises. Our tiny new a 1.5'' pendant proves when it comes to lighting, less really is more. a. The power of disciplined design. Product Overview Type: Direct/Indirect Lens, Louver Down/atwing, Clear lens up Wattage: 5W/ft, 10W/ft (other wattages available see p2) Lumen Output: 3,991 max; 95.0 Lm/W (5W/5W, 4ft fixture) Color Temp: 2700K, 3000K, 3500K, 4000K CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) Dimming: 0-10V, 1% dimming (standard) Lutron Hi-lume 3 wire, 1% dim Lutron Hi-lume EcoSystem, 1% dim Lutron Hi-lume 2 wire (120V only) Lutron Hi-lume EcoSystem, 1% dim, fade to off Lutron Hi-lume 5 Series DLI dimming, 0.1% dim *International version available, see website for spec sheet. 5 Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot Delivered Lumens LPW Color Temp 10 3991 95 3500K-83 20 6984 87.3 3500K-83 Data is based on 3500K-83 IES files available on website Data is based on 4' fixture with Performance Lens direct & atwing Lens indirect Runs Individual Runs: 2' - 8' (whole foot standard) Continuous Runs: vailable (whole foot standard) Custom: Made to measure available (nearest 1/8" of field dimensions). Requires approval drawings. dded cost & lead time. Electrical Data Wattage Per Foot 10 System Watts 4' 8' mps System Watts mps 120V 38 0.32 74 0.62 277V 42.6 0.16 76 0.28 120V 80 0.66 160 1.32 20 277V 80 0.30 160 0.60 Electronic multi-volt (120V-277V), constant current LED driver Standard Patterns Wall to Ceiling Custom* Yes Yes Yes Yes Yes No Yes * Submit drawing, consult factory LIT-2047 09/14/18 Page 1 of 9

Ordering Information LIN1.5DI-16 120/277 8 9 1 2 3 4 5 6 7 10 11 12 1 2 3 4 Model LIN1.5DI-16 Optics (select 1 from each list) Direct: PL - performance lens (standard) SLDW - straight blade louver (wh) solid blades w/overlay SLD - straight blade louver (blk) solid blades w/overlay SLDS - straight blade louver (slv) solid blades w/overlay SLDPW - straight blade louver (wh) perf blades w/overlay SLDP - straight blade louver (blk) perf blades w/overlay SLDPS - straight blade louver (slv) perf blades w/overlay SY - asymmetric lens Indirect: T - batwing uplight (standard) UC - upper clear lens cover Mounting SW10 - through ceiling tile or gyp board, white, 10' SW20 - through ceiling tile or gyp board, white, 20' S10 - through ceiling tile or gyp board, black, 10' S20 - through ceiling tile or gyp board, black, 20' SW10T - over ceiling tee, white, 10' SW20T - over ceiling tee, white, 20' S10T - over ceiling tee, black, 10' S20T - over ceiling tee, black, 20' WM - wall mount Circuiting 1 - single circuit 2 - up/down switch separately 7 8 9 10 Finish HW - high reflectance matte white T - black texture ST - silver texture For other RL color, consult factory Voltage 120/277 Length x x (Length ) (Length ) (Length C) Length (used for) Length (used for) Length C (used for) - all patterns - all patterns - PU - IND - PR - 2 lengths - PZ - CON of 2 - CUS Configuration IND 1 - individual fixture, 2' to 8' in 1' increments CON - continuous run > than 8', specify to nearest foot CUS - custom made to measure, +/- 1/8" of customer supplied field dimensions Standard Patterns (see page 6 for details): PLL - L left, (2) straights + (1) 90 corner, leg right PLR - L right, (2) straights + (1) 90 corner, leg left PU - U shape, (3) straight lengths + (2) 90 corners PR - Rectangle, (4) straight lengths + (4) 90 corners PZ - Z shape, (3) straight lengths + (2) 90 corners Custom Patterns: PC - please provide drawings and consult factory 5 6 Wattage (per foot, down/up) 5/5 10/10 5/10 10/5 Consult factory for other wattage options Note: 3' units must use same wattage for D/I components Color Temp 83 CRI: 27-2700K-83 30-3000K-83 35-3500K-83 40-4000K-83 92 CRI optional, consult factory 11 12 Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim Options/ccessories ENLS - Enlighted Sensor (0-10V driver only and not available on 2' & 3' lengths, can only be used on one circuit) EMC-PF 2 - emergency circuit requires power feed located in last fixture section (for other locations consult factory) PF 2 - Extra power feed for additional circuiting 1 - Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. 2 - Not available with IND (individual) configuration. The "" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your merlux representative for explanations of changes. LIT-2047 09/14/18 Page 2 of 9

Specifications pplication Open office plan, conference rooms, corridors or any indoor retail space where an exciting combination of direct and indirect ambient lighting is desired. Construction One piece extruded aluminum housing. Die-cast End Plates match fixture body finish. Die-formed, cold-rolled steel internal components are protected against rust and corrosion. Optical Direct: ll lenses are snap-in, extruded acrylic, with a maximum length of 8. Fixtures shipped with lenses installed. merlux's proprietary acrylic lens provides excellent transmission while effectively concealing source image. ll louvers are retained with spring clips attached to louver side rails, for good fit and retention. PL - Performance Lens provides high efficiency with greater lens surface brightness. SLD or SLDP - Straight blade Louver Direct has ½" high blades ½" on center with overlay. Solid (SLD) or optional Perforated (SLDP) blades. SY - symmetric 20º throw lens is backed high diffusion film that eliminates striations. Indirect: Extruded acylic lens with a maximum length of 8'. T - atwing uplight lens spreads light directly above fixture. 18" minimum distance between ceiling plane and top of fixture suggested. UC - Upper Clear lens cover. LED merlux's boards and patented connector design with brand name LEDs enables merlux fixtures to have excellent thermal management and offer a 5 year warranty. Our LED binning is within 3 Macdam ellipse. oards are configured for maximum flexibility resulting in even illumination no matter the fixture layout. LED boards are easily replaced in the field with just a Phillips screw driver. Color Temperature Options: 2700K, 3000K, 3500K, 4000K CRI: 83 typical, 92 optional - consult factory R9: 16 @ CRI 83 R9: >50 @ CRI 92 Life: 50,000+ hr., > 70% of initial lumens (L70) Electrical Wiring: Individual and "eginning of Run" (OR) fixtures are prewired with power cord. ll configurations have quick connect power harnesses for row connections. 1-1 Circuit, direct & indirect same circuit 2-2 Circuits, direct & indirect switch separately (power feed at both ends). Standard Wattage: 5W/ft, 10W/ft. Optional Wattages: 3W/ft, 4W/ft, 6W/ft, 7W/ft, 8W/ft, 9W/ft. (3W & 4W have a minium length of 4'). For other wattages consult factory Emergency circuit via remote inverter or auxiliary emergency power supply (by others). This product complies with IEEE C62.41 for surge endurance up to 2.5KV. merlux recommends using additional surge protection with this unit (supplied by others), surge damage is not covered under warranty. ENLS - Enlighted Sensor (0-10V driver only, not available in 2' & 3' lengths, and can only be used on one circuit) EMC-PF - Emergency circuit requires power feed to be located in last fixture section for continuous runs. For other locations consult factory. Not available for individual (IND) configuration. PF - Extra power feed for additional circuiting. Not available for individual (IND) configuration. Drivers 0-10V - 1% electronic dimming, multi-volt (120V-277V) constant current driver (standard). Cap leads for non-dim applications. Optional Drivers: HILUME--DH - Lutron "" Series, 1% dim, 3-wire (Dim Hot) HILUME--ECO - Lutron "" Series, 1% dim, EcoSystem HILUME--LTE - Lutron "" Series, 1% dim, 2-wire, 120V only HILUME-H-ECO - Lutron "H" Series, 1% dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DLI - DLI Dimming 120V-277V, 0.1% dim Finish ll painted surfaces are premium powder coated baked on for maximum durability and color stability. HW - High reflective matte T - Texture ST - Silver Texture For special paint colors supply RL and/or actual paint chip for factory consultation. Configurations/Lengths IND - Individuals are stand alone fixtures made of single lengths of 2' to 8' (in 1' increments). They are supplied with matching painted End Caps and the required mounting hardware. Lengths less than 4' may have restrictions based upon wattage, lengths, drivers or other options. CON - Continuous runs are longer than 8', specified to the nearest whole foot. Continuous runs less than 16' are made of 2 lengths. Continuous runs longer than 16' start with a 8' eginning of Row (or) wired with a power feed and fitted with an End Cap. The majority of the runs are made up of 8' Middle of Run (MoR) lengths. End of Run (EoR) units are made up of 2' to 8' units to the nearest whole foot or a combination of a last 4' MoR and a 5', 6' or 7' EoR. Runs longer than 60' may require a second power feed. Factory installed pins and splines simplify fixture alignment. Lengths are quickly joined with "catch and latch" mechanisms or screws and sturdy brackets. Quick connectors simplify field wiring. CUS - Custom made to measure runs are made to nearest 1/8" of customer supplied field measurements. They can be a single custom length or runs configured as described above only EoR's are 2' to 8' cut to the nearest 1/8" exact length or a combination of a last 4' MoR with an EoR cut to exact length to the nearest 1/8". PXX - Standard patterns consist of 90º corners with standard lengths (3' to 8' in 1' increments) or custom lengths. Depending upon complexity of the pattern, drawings may be required. When ordering please give overall lengths. See page 6 for layouts. PC - Custom patterns use standard or custom lengths, 90º or other corner angles with some limitations. Please provide drawings and consult factory. Mounting The a 1.5 Direct/Indirect is intended to be pendant or wall mounted in continuous rows. For indirect lighting merlux suggests 18" min from top of fixture to ceiling. Standard or custom patterns available. LIN1.5DI-16...SW10 - Direct/Indirect installed in center of ceiling tile or gypsum board ceiling, (standard) i.e. SW10. Or if canopy is installed on a grid Tee runner add, T i.e. SW10T. Cable Suspension: Cable is stranded stainless steel wire supplied with cable gripper and 5"x.250" steel die formed canopy. ll components are protected against rust and corrosion. Power feeds are 16 gauge 3 or 5 conductor SJT cord supplies in same color as canopy. merlux supplies the required feed and non-feed suspension kits based upon length, electrical options and customer requirements. Suspension kit options include: color, length and mounting condition. Please note: 1 Circuit is standard, the direct & indirect are on the same circuit. 2 Circuits, direct & indirect switched separately with power feeds at both ends. LIN1.5DI-16... WM - Wall Mounted using steel cleat bracket attached to fixture housing and wall bracket with set screws. Two bracket assemblies are used for each length under 8'. third center bracket may be recommended. J box required at feed locations. Certifications pproved to UL standards for damp locations as tested by CS Intended for indoor use only Warranty merlux's 5 year limited warranty. Please consult merlux website for details. LIT-2047 09/14/18 Page 3 of 9

LINE 1.5" DIRECT/INDIRECT 7/8" 1 5 /8" Power Suspension Kit location 3 1 /4" 1 1 /2" 3/32" Overall length of run LINE 1.5" DIRECT/INDIRECT WLL MOUNT 6" Mounting O. C. location 1/2" 3 1 /4" 1/2" 2" 1 1 /2" 3/32" Overall length of run OPTIONL LENS/LOUVER For symmetric distribution this should be opposite the wall Optional symmetric Lens TOOLLESS JOINING up the two housings by using the alignment pins & splines. Secure them together by using the Catch & Latch System on the top on the extrusion. Connect Power Connect power to previous tray via power supply harness. Power Supply Harnesses Secure Fixtures/Joint OR lignment Pins & Splines MOR/EOR lign pins & press fit fixtures together Catch & Latch Optional Louver LIT-2047 09/14/18 Page 4 of 9

CLE KIT SUSPENSION OPTIONS: CEILING OR GYPSUM ORD (SW10, SW20, S10, S20) 1/4"-20 x 3/4" L Philips Flat Head Screw FEED J-ox secured to structure above by others Countersunk 1/4"-20 Gem ar Strain Relief ushing N0N-FEED 1/4"-20 rod or wire secured to structure above (by others) Cat# Length Cord/Canopy pplication SW10 10' white/white ceiling tile/gypsum SW20 20' white/white ceiling tile/gypsum S10 10' black/black ceiling tile/gypsum S20 20' black/black ceiling tile/gypsum SW10T 10' white/white ceiling tee SW20T 20' white/white ceiling tee S10T 10' black/black ceiling tee S20T 20' black/black ceiling tee 5" Canopy Power Cord 5" Canopy Two piece Cable Coupler Cable Tie (1 per foot) 1/16" Cable Gripper/Locknut (size will vary) TEE GRID OR SCREW SLOT (SW10T, SW20T, S10T, S20T) FEED Drop Ceiling J-ox (supplied) Drop Ceiling T-ar by others (for Drop Ceiling application) NON-FEED Drop Ceiling T-ar by others IDS Clip with 1/4"-20 Stud by others 5" Canopy LIT-2047 09/14/18 Page 5 of 9

OPTIONL ENLIGHTED SENSOR: merlux and Enlighted have partnered to create building environments that are safer, and smarter, than ever before. t the heart of our partnership is Enlighted's Smart Sensor, the most advanced digital sensor available today. Integrated into merlux products, the sensor seamlessly collects and communicates dense data on building security, occupancy, performance, environmental conditions, ambient light levels, temperature, and energy consumption. This intelligence provides building managers with unprecedented guidance on cost savings and site-planning efficiencies. Enlighted Sensor (ENLS) is available with 0-10V driver only. Minimum run length is 4'. Enlighted power pack is provided with ENLS option. 4 FT OR 8 FT RUNS Optional Enlighted Sensor 8 8 LINE 1.5" PTTERNS: Standard Patterns ll corners are standard 90, standard length legs. Use standard lengths: 4' min to 8' in 1 foot increments. Continuous runs must be the same length in pairs for closed configuration. Custom Patterns Please provide drawings of your configuration. Made to Measure: +/- 1/8", consult factory. PC - custom pattern, please provide drawings and consult factory 6" 90 6" a 1.5 Lens Mitered Lens PLL PLR PLL - L Left, (2) straights + (1) 90 corner, leg right PLR - L Right, (2) straights + (1) 90 corner, leg left Provide overall lengths: ' & ' Nomenclature: --PLL --PLR PR - Closed Rectangle, (4) straight lengths + (4) 90 corners Provide overall lengths: ' & ' Nomenclature: --PR C C PU - Open U, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PU PZ - Open Z, (3) straight lengths + (2) 90 corners Provide overall lengths: ', ' & C' Nomenclature: --C-PZ LIT-2047 09/14/18 Page 6 of 9

FIXTURE DT: (Complete photometric data (.ies format) available upon request) MULTIPLYING FCTORS: (Multiplying Factor is based on 3500K-83 120V IES file on website) Wattage: 3W 4W 5W 6W 7W 8W 9W 10W CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.63 0.82 1.0 1.17 1.34 1.50 1.64 1.75 Factor: 0.87 0.93 1.0 1.08 LINE 1.5 DI PERFORMNCE LENS DIRECT/TWING LENS INDIRECT 5W UP/5W DWN 3500K 4FT Total Watts: 42 Total Lumens: 3,991 Source: 184 LED's 180 LTL# 695283 LTL# 695284 150 CROSS 45 LONG LINE 1.5 DI STRIGHT LDE LOUVER DIRECT/TWING LENS INDIRECT 5W UP/5W DWN 3500K 4FT Total Watts: 42 Total Lumens: 3,060 Source: 184 LED's 180 150 120 120 90 90 350 300 60 60 700 600 CROSS 45 LONG 0 30 0 30 ZONL LUMEN SUMMRY Zone Lumens %Fixt 0-30 620 15.53 0-40 966 24.21 0-60 1546 38.72 0-90 1857 46.54 40-90 891 22.31 60-90 312 7.82 90-180 2134 53.46 0-180 3991 100.00 Efficacy = 95.0 Lumens /Watt COEFFICIENTS OF UTILIZTION Effective Floor Cavity Reflectance 20% RC 80 RW 70 50 30 10 RCR 0 1.06 1.06 1.06 1.06 1 0.98 0.94 0.90 0.87 2 0.89 0.83 0.77 0.72 3 0.82 0.73 0.67 0.61 4 0.76 0.66 0.58 0.53 5 0.70 0.58 0.51 0.45 6 0.64 0.53 0.45 0.40 7 0.59 0.47 0.40 0.35 8 0.55 0.43 0.36 0.30 9 0.51 0.39 0.32 0.27 10 0.47 0.36 0.29 0.24 ZONL LUMEN SUMMRY Zone Lumens %Fixt 0-30 448 14.64 0-40 639 20.90 0-60 853 27.88 0-90 930 30.40 40-90 291 9.50 60-90 77 2.51 90-180 2130 69.60 0-180 3060 100.00 Efficacy = 72.8 Lumens /Watt COEFFICIENTS OF UTILIZTION Effective Floor Cavity Reflectance 20% RC 80 RW 70 50 30 10 RCR 0 1.02 1.02 1.02 1.02 1 0.94 0.91 0.87 0.84 2 0.87 0.80 0.75 0.70 3 0.80 0.72 0.66 0.60 4 0.74 0.65 0.58 0.52 5 0.68 0.57 0.51 0.46 6 0.63 0.53 0.45 0.40 7 0.59 0.48 0.40 0.36 8 0.55 0.43 0.36 0.32 9 0.51 0.40 0.33 0.28 10 0.47 0.36 0.30 0.25 LIT-2047 09/14/18 Page 7 of 9

DIMMING COMPTIILITY: merlux a fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY --- 0-10V - DIMMING (Standard) Integrates into a variety of building management and daylighting controls 0-10V Wiring Diagram 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox Lutron: Wattstopper: Leviton: Diva - DVSTV DF-120277 Renoir II Maestro - MS-Z101 Nova-T - NTSTV-DV Center System Lutron Grafixk Eye with GRX-TV1 Interface 0-10V Dimming Gray Purple Driver 0-10V (-) 0-10V (+) Switched Hot V+ V- Red LUTRON HI-LUME DIMMING Integrates into Lutron EcoSystem building management 120V or 277V* Dims down to less than 5% light output May use 3-Wire or EcoSystem Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Compatible Dimmers : Wall ox (3-Wire Dimming) Lutron: Diva Maestro Nova-T Vareo Center System Lutron EcoSystem compatible controls HILUME--DH 3-Wire Wiring Diagram Cap unused ECOSYS wires 3-Wire Phase Dimming Purple Stripe Purple Orange E1 E2 Driver Dimmed Hot Switched Hot HILUME--ECO, HILUME-H-ECO, HILUME-5-ECO EcoSystem Digital Wiring Diagram E2 E1 ECOSYS us EcoSystem Dimming Purple Stripe E1 Driver Purple E2 (Cap off Orange wire) Orange Dimmed Hot Switched Hot V+ Red V- V+ V- Red * Driver is 277V dimmable with appropriate dimmer (by others). ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT-2047 09/14/18 Page 8 of 9

DIMMING COMPTIILITY: merlux a fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. merlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMTION ELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FCTORY --- LUTRON HILUME--LTE DIMMING Utilizes Standard incandescent dimmers that are in wide use in installations across the US. est for retrofit applications where TRIC dimmers are installed. 120V only Dims down to less than 1% light output (most cases) Consult Dimming manufacturer for installation instructions - DO NOT SHRE NEUTRLS! Must meet dimmer Minimum Load Requirements per dimming manufacturer Compatible Dimmers : Wall ox (Incandescent Style, Wattage as required) Lutron: Diva Maestro Nova-T Vareo Skylark Center System Lutron "GP" Panel Lutron Grafik Eye QS Lutron HILUME--LTE Wiring Diagram TRIC Dimming Driver V+ V- Red DLI - DLI DIMMING 120V-277V Digital control protocol allows individual fixture control DLI Wiring Diagram 120V - 277V* Dims down to 0.1% light output in most cases DLI Dimming Purple Purple/WT DLI us Driver V+ Red Compatible Dimmers : Wall ox Leviton CD250 ler V- Center System Dynalite Fifth Light * Driver is 277V dimmable with appropriate dimmer (by others). ll provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. The absence of a dimmer from the lists above does not imply incompatibility. Please consult factory for compatibility inquiries. LIT-2047 09/14/18 Page 9 of 9