CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

Similar documents
CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

High Temperature InfraRed Thermometer with Laser Pointer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

IRT2 Dual Laser IR Thermometer - User Guide

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

DIGITAL / ANALOG MEGOHMMETERS 1030

Manual PCE-889 pyrometer

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

64 Max IR Thermometer

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Precision Infrared Thermometer. Users Manual

R2310. Infrared Thermometer. Instruction Manual

Visit us at testo 835 Infrared and contact thermometer

I/R Thermometer Gun 12:1

64 Max IR Thermometer

Users Manual. Visit us at

10A Micro-Ohmmeter Model 6250

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

10A Micro-Ohmmeter Model 6250

MT4 MAX/MT4 MAX + Infrared Thermometer

OMEGA. OS643E-LS/OS643E Infrared Thermometer With Laser Sighting

Infrared Thermometer

Infrared Thermometer. Getting Started

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Pocket Moisture Meter Instruction Manual

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

OMEGA (MODEL:610LF) OS642F-LS Infrared Thermometer With Laser Marker

62 MAX/62 MAX + Infrared Thermometer. Users Manual

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

562/563. Infrared Thermometers

IR D USB INFRA RED THERMOMETER

Microprocessor Digital Thermometer

62 MAX/62 MAX + Infrared Thermometer

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

62 MAX/62 MAX + Infrared Thermometer

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Users Manual. Infrared Thermometer

100 Ft. LASER DISTANCE METER

Precision Infrared Thermometer. Users Manual

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Class 1 laser beam sensor safe for your eyes

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

HIn3550 Magnetic Field Monitor User's Manual

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

Class 1 laser beam sensor safe for your eyes

Design Manual Installation Operation Maintenance

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

4-IN-1 PIN/PAD RH MOISTURE METER

RS Pro Infrared Temperature Sensor

Innovative Technology for Traditional and Challenging Applications

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Class 1 laser beam sensor safe for your eyes

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

Instruction Manual. Self-Leveling Laser Level Model No

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

62 MAX/62 MAX + Infrared Thermometer

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

optris TM Temperature Monitor for Infrared Sensors Operators manual

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Model OEM-2 INSTRUCTIONS FOR USE

3R, 3G 5R, 5G Point Laser Levels

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Warranty Registration

Operator's Manual. LIGHTNING 2 Laser Detector

Buzzer Unit. TAN-5000 Series. Operating Manual

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

HI COD REACTOR and Test Tube Heater 2008 Series

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Thermohygrometer with Single Type K Input and Superheat Function

Black Body Calibration Source User Manual

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

User Manual. Non-contact Infrared Thermometer.

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

RK-05 Carbon Monoxide Detector Operator s Manual

Customers must fill in and mail the warranty card in order to activate the warranty.

User's Guide. Pinless Moisture Meter. Model MO257

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Instruction Manual Item No.: V~, 60Hz

EVac II Programmable Digital Vacuum Gauge

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Transcription:

Auto OFF INFRARED K-THERMOMETER WITH LASER CA876 ENGLISH User Manual

Owner s Record The serial number for the Model CA876 is located inside the battery compartment of the instrument. Please record this number and purchase date for your records. INFRARED K-THERMOMETER MODEL CA876 CATALOG #: 2121.34 SERIAL #: PURCHASE DATE: DISTRIBUTOR:

Table of Contents 1. INTRODUCTION... 2 1.1 International Electrical Symbols...3 1.2 Receiving Your Shipment...3 1.3 Ordering Information...3 2. PRODUCT FEATURES... 4 2.1 Description...4 2.2 Button Functions...5 2.2.1 Center (Yellow) Button - MEAS...5 2.2.2 Mode Button...5 2.2.3 Back-light and Button...6 2.2.4 Laser and Button...6 3. SPECIFICATIONS... 7 3.1 Environmental Specifications...7 3.1.1 Infrared...7 3.1.2 K-Type...8 3.2 General Specifications...9 3.3 Safety Specifications...9 4. OPERATION... 10 4.1 Infrared Measurement Considerations...10 4.2 Recommendations before Operating... 11 4.3 Infrared Operation...12 4.4 K-Thermocouple Operation...12 4.5 Setting the Temperature Scale: C or F...13 4.6 Continuous Measurement...13 5. MAINTENANCE... 14 5.1 Replacing the Battery...14 5.2 Cleaning...14 Repair and Calibration...15 Technical and Sales Assistance...15 Limited Warranty...16 Warranty Repairs...16

CHAPTER 1 INTRODUCTION Warning Thermometers are not designed to touch live electrical samples. Do not use this instrument with Thermocouple K when voltages at the sample point exceed 24VDC or 24Vrms. Do not make temperature measurement in microwave ovens. Leaking microwaves may result in burns and serious injuries. To prevent sensor damage, do not point the sensor lens directly at the sun or any other source of strong infrared light. Do not look directly into the laser beam, and do not aim the laser beam into eyes. Do not place the infrared thermometer directly on or close to objects at temperatures exceeding 158 F (70 C). To prevent measurement errors, do not expose the thermometer to strong electrical or electromagnetic fields. To prevent sensor damage and erroneous readings, do not put the sensor lens into contact with any body or foreign/loose material when measuring. Keep the sensor perfectly clean. Do not touch the sensor when taking measurements as it may affect the readings. When the meter is exposed to sudden temperature changes (hot or cold), allow 20 minutes of stabilization before taking a reading. Be certain there is no condensation on the lens prior to taking measurements. Allow 10 minutes for condensation to dissipate as needed. The Model CA876 is not waterproof or dust-proof. Take necessary precautions to protect it in wet or dusty environments. Repeated sharp flexing can cause the thermocouple leads to break. To prolong sensor life, avoid sharp bends in the thermo- Quality AEMC Products couple, Online especially at: near the connector. 2 Infrared K-Thermometer Model CA876

1.1 International Electrical Symbols This symbol on an instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In a manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installation/sample and product damage may result. Laser Radiation - DO NOT look into the laser beam. Laser Output < 0.5mW, 670nm wavelength. 1.2 Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. 1.3 Ordering Information Infrared Thermometer Model CA876...Cat. #2121.34 Includes K-thermocouple, 9V Alkaline battery, rugged, shockproof, protective safety holster and user manual. Infrared K-Thermometer Model CA876 3

CHAPTER 2 PRODUCT FEATURES 2.1 Description The AEMC Model CA876 is a portable, easy-to-use, compact-sized digital infrared and K-thermocouple input thermometer, designed for simple one-hand operation. It uses an infrared sensor with a user adjustable emmisivity setting. The thermometer is simply aimed at the target to be measured without any physical contact when in the IR mode (non-contact temperature measurement). An aiming laser enables the user to pinpoint the target. The K-type thermocouple input may also be used. The thermometer includes a programmable Alarm, which triggers on Hi or Lo, and a MIN or MAX Hold function. The thermometer is supplied with a protective holster, built-in sensor, and a K-type bead thermocouple. It also features a back-light LCD display, an automatic data HOLD function, and Auto-OFF. 1 2 3 Auto OFF 4 5 1. 3½ digit display 2. Mode selector 3. Back-light/ Increase button 4. Laser/ Decrease button 5. Power/ Measure button 4 Infrared K-Thermometer Model CA876

2.2 Button Functions 2.2.1 Center (Yellow) Button - MEAS Press this button to turn the thermometer ON and perform a measurement. When the button is released, the meter will automatically HOLD (freeze) the last reading on the display for approximately 15 to 20 seconds before automatically shuting OFF. 2.2.2 Mode Button Pressing this button makes the thermometer enter and advance though several functions including some programmable functions. The MODE button is used to select a specific function (e.g. MIN, MAX) or to adjust an Alarm or the emissivity. To enter the mode program, press MODE once. SET is displayed in lower right hand corner. When pressed consecutively, it will scroll through the following settings: ε ε (Set) ALM Hi (Set) ALM Lo (Set) MAX MIN K ε SET is displayed in the lower right hand corner of the display when a selected function is programmable (ε, ALM Hi, ALM Lo). ε: Emissivity may be adjusted with the and buttons to match a particular target. We recommend leaving it at 0.95 for general use. ALM Hi: The Hi alarm set point is adjusted using the and buttons. When this set point is reached the beeper will sound and ALM HI will be displayed. ALM Lo: The Lo alarm set point is adjusted using the and buttons. When this set point is reached the beeper will sound and ALM Lo will be displayed. MAX: The Max value measured will be displayed during measurement. While in the MAX mode and when measuring, the MODE button will toggle the measurement between MAX MIN Present reading MAX. MIN: The Min value measured will be displayed during measurement. While in the MIN mode and when measuring, the MODE button will toggle the measurement between MIN Present reading MAX MIN. K: The lower display will indicate the reading from the K-type thermocouple. NOTE: If the thermometer is OFF, pressing the MEAS button for more than 4 seconds will set the thermometer in the MIN/MAX record mode when powered up. Infrared K-Thermometer Model CA876 5

2.2.3 Back-light and Button Press the button to turn the Back-light ON. Press again to turn OFF. In the settings ε, ALM Hi and ALM Lo, the button increases the numerical value displayed in the lower smaller display area. If held down, the value change will increase in speed. 2.2.4 Laser and Button Pressing the button turns the laser ON or OFF. The symbol is displayed in the upper left hand corner when the laser is ON. Remove the laser cover before use. The laser is activated when the MEAS button is pressed during a measurement. In the settings ε, ALM Hi and ALM Lo, the button decreases the numerical value displayed in the lower smaller display area. If held down, the value change will decrease in speed. NOTE: There is no ON/OFF button. The meter turns ON when the center MEAS button is pressed, and will automatically shut OFF after approximately 15 to 20 seconds. 6 Infrared K-Thermometer Model CA876

CHAPTER 3 SPECIFICATIONS 3.1 Environmental Specifications 3.1.1 INFRARED Temperature Scale: Celsius ( C) or Fahrenheit ( F) user-selectable Temperature Range: -4 F to 1022 F (-20 C to 550 C) Display Resolution: 1 F / 1 C Accuracy: < 212 F (100 C) ± 10 F (5 C) > 212 F (100 C) ± 2% of Reading or ± 6 F (3 C), whichever is greater @ 64.4 to 82.4 F (18 to 28 C) ambient operating temperature. Temperature Coefficient: Changes in accuracy operating temperature above 82.4 F/28 C or below 64.4 F/18 C: ±0.2% of Reading or ± 0.36 F/0.2 C, whichever is greater. Response Time: 1 second Laser: Red, <0.5mW (670nm) Class II, 2-50 ft range Spectral Response: 6 to 14μm nominal Emissivity: Pre-set @ 0.95, user-selectable from 0.10 to 1.00 Detection Element: Thermopile Quality AEMC Optical Products Lens: Online Fresnel at: Lens Infrared K-Thermometer Model CA876 7

Field of View (FOV) ratio: 10:1 (Distance : Diameter) Distance to object 1" Ø (25mm) 2" Ø (50mm) 3" Ø (75mm) 4" Ø (100mm) 10" (250mm) 0.63" (16mm) 20" (500mm) 30" (750mm) 40" (1000mm) The FOV is the ratio of the distance to the target to the target diameter. When the target diameter is small, it is important to bring the thermometer closer to the target to ensure that only the target is measured, excluding the surroundings. Remember that the measurement size is one-tenth the distance to the target. For example, if the thermometer is at 10", then the size measured is 1". 3.1.2 K TYPE Temperature Scale: Celsius ( C) or Fahrenheit ( F) - User-selectable Measurement Range: -40 to 2000 F or -40 to 1350 C Resolution: 0.1 F/ C or 1 F/ C Accuracy: -328 F to 1999 F: ± 0.1% of Reading ± 2 F plus T.C. -199 C to 1370 C: ± 0.1% of Reading ± 1 C plus T.C. (Accuracy is specified for operating temperatures over the range of 64 to 82 F (18 to 28 C), for 1 year, excluding the sensor) Temperature Coefficient: 0.1 times the applicable accuracy specification per C from 0 to 18 C and 28 to 50 C Input Protection: 24VDC or 24Vrms maximum input voltage on any combination of inputs Sample Rate: 2.5 times per second Input Connector: Standard miniature thermocouple connectors (flat blades spaced 7.9mm, center-to-center) Temperature Response: Temperature indication follows Reference Temperature/Voltage Tables N.I.S.T. Monograph 175 Revised to ITS-90 for K-type thermocouples 8 Infrared K-Thermometer Model CA876

3.2 General Specifications Display: 2000-count, 3½ digit liquid crystal display (LCD) with maximum reading of 1999 Low Battery Indication: below required level Sample Rate: 2.5 times per second, nominal is displayed when battery voltage drops Operating Temperature: 32 to 122 F (0 to 50 C) at < 80% RH Storage Temperature: -4 to 140 F (-20 to 60 C), 0 to 80% RH with battery removed Auto Power Off: 15 seconds approx Altitude: 2000m max Input Protection: 24VDC or 24rms maximum input voltage on any combination of inputs Battery: Standard 9V battery (NEDA 1604, 6LR61 or equivalent) Battery Life: 100 hours (continuity) typical with carbon zinc battery (backlight not illuminated) Dimensions: 6.81 x 2.38 x 1.5" (173 x 60.5 x 38mm) Weight: Approx 9 oz (255g) including battery 3.3 Safety Specifications EN 61010-1 (1995-A2), Protection Class III Overvoltage Category (CAT III, 24V), Pollution Degree 2 Indoor Use *All specifications are subject to change without notice Infrared K-Thermometer Model CA876 9

CHAPTER 4 OPERATION 4.1 Infrared Measurement Considerations MEASUREMENT THEORY Every object emits infrared (IR) energy proportional to its temperature. By measuring the amount of this radiant energy, it is possible to determine the temperature of the emitting object. Infrared radiation is invisible light (electromagnetic radiation), which easily travels through air and is easily absorbed by solid matter. An IR thermometer, which operates by detecting infrared radiation, can accurately measure an object surface temperature without touching it and independently of the air temperature or the measurement distance. Infrared radiation, which is emitted from the object, is focused into an infrared radiation sensor through an optical system. This system includes an optical lens, which is transparent to infrared radiation, and a 5.3μm cut off filter. The output signal from the infrared radiation sensor is input to an electronic circuit, along with the output signal from a standard temperature sensor, to calculate the temperature and display it on the meter display. EMISSIVITY All objects emit invisible infrared energy. The amount of IR energy emitted is proportional to the object s temperature and its natural ability to emit IR energy. This ability, called emissivity, is based upon the object material type and its surface finish. Emissivity values range from 0.10 for a very reflective object to 1.00 for a black body. Factory set emissivity value of 0.95 will cover 90-95% of typical applications. If frost or other material/substance covers the measured surface, clean it to expose the surface. If the surface to be measured is highly reflective, apply dull masking tape or matte black paint over the surface. If the thermometer seems to be giving incorrect readings, check the front sensor. There may be condensation or debris obstructing the sensor. Only clean per instructions. 10 Infrared K-Thermometer Model CA876

Material Emmisivity Material Emmissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Lather (Soap) 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matte) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium oxide 0.81 Plaster 0.80 to 0.90 Copper oxide 0.78 Mortar 0.89 to 0.91 Iron oxide 0.78 to 0.82 Brick (red) 0.93 to 0.96 Textiles 0.90 4.2 Recommendations before Operating If the measured surface target diameter is less than 2"/50mm Ø, then place the sensor as close as possible to the target surface (<20"/50cm away). See Field of View (FOV) information under Specifications. If the target surface is covered with frost or any matter, clean it before taking a measurement. If the target surface is highly reflective put some matte tape, or matte paint, over it before measuring. If the thermometer is erratic, or seems not to be measuring properly, make sure that the sensor is clean and not covered by condensation. Infrared K-Thermometer Model CA876 11

4.3 Infrared Operation 1. Press and hold the yellow measurement button - MEAS. The thermometer will display SET briefly on the main display while it auto-checks. 2. Aim the Thermometer towards the target. 3. If using the aiming laser, remove the laser cover, and press the Button to turn the laser ON and OFF. The laser is activated when MEAS is pressed. 4. Infrared thermometer sensors need a certain time to stabilize to ambient temperature. Remember to let the IR meter reach ambient if brought in from different temperature environment. 5. Press the button to turn ON the back-light. 6. If the measured temperature is outside the measurement range, will be displayed. 7. The thermometer will continue measuring as long as the MEAS button is pressed. When the button is released the measurement will be held in the display for 15-20 seconds. HOLD is displayed in the lower lefthand corner of the display. 8. The IR thermometer will shut OFF automatically after 15-20 seconds. 4.4 K-Thermocouple Operation 1. Connect the K-thermocouple to the instrument input. 2. Press MEAS to turn the thermometer ON. 3. Press the MODE button (six times) to enter the thermocouple mode. K will be displayed in lower right hand corner of the display. 4. Put the thermocouple near or on the sample tested. 5. Press MEAS button to measure. Thermocouples need a certain time to respond. Take the reading when the measurement has stabilized. The reading is displayed in the smaller lower display in front of the K symbol. The main larger display is the IR temperature reading. 6. The thermometer will continue measuring as long as the MEAS button is pressed. When the button is released, the measurement will be held Quality AEMC Products in the display Online at: for 15-20 seconds. 12 Infrared K-Thermometer Model CA876

7. When finished, remove the thermocouple from the sample, and unplug the thermocouple from the meter. The thermometer will shut OFF automatically after 15-20 seconds. Note: IR measurements are active at the same time as the K t/c measurements. 4.5 Setting the Temperature Scale: C or F The temperature scale is displayed on the upper part of the display. To select the temperature scale: C: When the thermometer is OFF, hold down the button, then press the MEAS button. C will be displayed. F: When the thermometer is OFF, hold down the button, then press the MEAS button. F will be displayed. The selected temperature scale will remain until changed by the user. 4.6 Continuous Measurement The user may want to leave the thermometer ON to measure over an extended time period without having to keep pressing the MEAS button. To enter the continuous mode: Turn the thermometer OFF. Hold down the MODE button, then press the MEAS button. This will set the thermometer in the continuous mode. HOLD will not be displayed in the continuous mode and the laser sighting will not run. When finished, press MEAS once. HOLD will be displayed and the thermometer will shut down in 15-20 seconds. Alternatively, press MEAS again to re-enter the continuous mode. Infrared K-Thermometer Model CA876 13

CHAPTER 5 MAINTENANCE Use only factory specified replacement parts. AEMC will not be held responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. 5.1 Replacing the Battery The symbol appears on the LCD display when replacement is needed. Replace with a standard 9-volt alkaline battery (NEDA 1604, 6LR61). To replace the battery: Turn the meter OFF. Remove the rubber holster. Remove the screw from the back of the meter and lift off the battery cover. Replace the battery, then put the rear cover and holster back on. 5.2 Cleaning Use a soft cloth lightly dampened with soapy water. Rinse with a damp cloth and then dry with a dry cloth. Do not use any abrasives or solvents. Do not let any liquid enter the case or sensor area. 14 Infrared K-Thermometer Model CA876

Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be scheduled back to our factory Service Center at one-year intervals for recalibration, or as required by other standards or internal procedures. For instrument repair and calibration: You must contact our Service Center for a Customer Service Authorization Number (CSA#). This will ensure that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA# on the outside of the shipping container. If the instrument is returned for calibration, we need to know if you want a standard calibration, or a calibration traceable to N.I.S.T. (Includes calibration certificate plus recorded calibration data). Ship To: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com (Or contact your authorized distributor) Costs for repair, standard calibration, and calibration traceable to N.I.S.T. are available. NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 E-mail: techsupport@aemc.com www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. Infrared K-Thermometer Model CA876 15

Limited Warranty The Model 876 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC Instruments. For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the Warranty Coverage Information with your records. What AEMC Instruments will do: If a malfunction occurs within the one-year period, you may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC Instruments will, at its option, repair or replace the faulty material. REGISTER ONLINE AT: www.aemc.com Warranty Repairs What you must do to return an Instrument for Warranty Repair: First, request a Customer Service Authorization Number (CSA#) by phone or by fax from our Service Department (see address below), then return the instrument along with the signed CSA Form. Please write the CSA# on the outside of the shipping container. Return the instrument, postage or shipment pre-paid to: Ship To: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument. 16 Infrared K-Thermometer Model CA876

Notes:

03/12 99-MAN 100246 v5 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments Quality AEMC 15 Faraday Products Drive Online Dover, at: NH 03820 USA Phone: (603) 749-6434 Fax: (603) 742-2346 www.aemc.com