ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

Similar documents
Astro Express 2 - Hot Water Delivery System

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

instant hot water no waiting & no waste benefits Hot water recirculation solutions Astro hwr

Astro 2 circulator models. Installation and operating instructions

E.2 series high efficiency circulator. Installation and operating instructions

Installation and operating instructions. E.2 Series high efficiency circulator

569, 570, 571, 572 Series

569, 570, 571, 572 Series

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

SCHWAN INSTALLATION GUIDE

INSTANT HOT WATER RECIRCULATING SYSTEM

INSTRUCTION MANUAL A REVISION A. Series e 3-4/e 3-6 Instant Hot Water Recirculating Systems

Installation and Operating Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Autocirc Instant Hot Water Pump Model: ACT E10 INSTRUCTION MANUAL REVISION A

Installation & Operating Guide

INSTANT HOT WATER DISPENSER

SCHWAN INSTALLATION GUIDE

568X, 587X, 588X Series

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Installation Instructions

Seal-less Centrifugal Canned Motor Pumps For Instant Hot Water Recirculating Systems

! WARNING. Before using product, read and understand instructions.

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

! WARNING. Before using product, read and understand instructions.

Refrigerator. Installation Guide. Free Standing Appliance

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

FSW300 Series Flow Switch

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SuperKlean Washdown Products

Floating Pond Pump System 1/2, 3/4 & 1 HP 230V Models FPS05021, FPS07021, FPS10021

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

T874 Multistage Thermostat and Q674 Subbase

LC Series - Light Commercial Pump Station Installation and Operation Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Instruction Manual. Bell & Gossett ecocirc wireless Potable Hot Water Recirculation Kit

Comfort Series Instant Hot Water System

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

15R HARDWARE INSTALLATION GUIDE

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

OWNERS GUIDE TO INSTALLATION AND OPERATION

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions

Installation Instructions

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Installation & Operation

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

Installation & Operating Guide

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS. Super Pump Series

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Autotrol Performa FA Valve

WH-TD20B3E5 WH-TD30B3E5

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

MIX Boiler & Font Range Service Manual

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Hydraulic Crimping Head, PN

Mix Boiler & Font Range ( #, #, #, , )

! WARNING. Before using product, read and understand instructions.

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

INSTANT-FLOW C-MICRO WATER HEATER

INFRARED ZONE HEATING SYSTEM

Multi-Function Cooktop

FIREPLACE INSTALLATION

INTELLIGENT, HEALTHFUL LIVING

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

Dual Column Dehydrating Breather Manual

Installation and Operating Instructions

MODELS: TJ45 TJ90 Operator s Manual

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Transcription:

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.817 Date: july 23, 2015 Supersedes: 10.817 Date: june 3, 2015 1.0 Typical installations 1 2.0 How it works 1 3.0 Installation 1 4.0 Procedures 1 5.0 Rotating the circulator casing 3 6.0 Operation 3 7.0 Setting the clock/timer 4 8.0 Replacement parts 4 9.0 Technical data 5 10.0 Replacement parts 6 1.0 typical applications The Armstrong Astro Express 2 hot water delivery system ensures that users have hot water at the tap when you need it, while helping to conserve water. It is easy to install, and does not require special return piping to the water heater. Equipped with a high performance circulator and adjustable flowrate injection valve, the Astro Express 2 system is a onesize-fits-all solution for virtually any residential installation. The Astro Express 2 is the ideal solution for existing home retrofit where recirculation system return line installation is impractical, or new home construction where dedicated hot water return line installation is cost prohibitive. caution Ensure the hot and cold water supply is turned off before installation, to avoid personal injury or damage to property. Read and understand these instructions thoroughly before beginning installation. Prior to installation flush all piping of any foreign material to prevent pump blockage and prevent damage. 2.0 how it works Armstrong Astro Express 2 hot water delivery systems consist of a circulator for water heater mounting, and a valve for under-sink mounting. In operation, the timer activated circulator creates differential pressure across the Astro Express lf valve. When the water at the hot water faucet cools below the Astro Express lf valve's low temperature setpoint, the valve opens, allowing the cooled water to be injected into the cold water line. When the water reaches the valve high temperature setpoint, the valve closes. The valve is equipped with a pressure independent flowrate adjustment to maintain the desired temperature balance. Additionally, the valve is equipped with a check valve to prevent cold water backflow when the hot water faucet is opened. 3.0 installation warning Installation should only be completed by qualified personnel, in accordance with all applicable codes, and following generally accepted installation practices.

installation & Astro Express 2 2 4.0 procedures timer 1 Timer installation and wiring warning Electrical shock hazard - Verify that the electrical rating of the device matches the values shown on the nameplate of the circulator. All electrical work should be performed by a qualified electrician in accordance with the latest edition of the National Electric Code, local codes and regulations. Failure to follow these instructions could result in serious injury, death and/or property damage. Note: Numerical component designations included in Steps 1 through 8 refer to circulator and timer components shown in fig. 1. Steps 1 & 3 apply to retrofit installations. 1 Disconnect the electrical supply to the circulator Note: Numerical component designations included in Steps 2 through 8 refer to circulator and timer components shown in fig. 1. 2 Unfasten the mounting 2 screws (4) and remove the terminal box cover (3). 3 Disconnect wire leads from the power supply. 4 Connect power supply wires (black, white and green) to the timer unit and to the circulator terminals (as shown in fig.2). Note: Lead Wiring Specification - Minimum, 6" (152 mm) long, 14 awg, rated minimum 140 f (60 c). Provided with r/c crimp connectors for attachment to the ground. 5 Place the timer box cover (5) using the 2 mounting screws (4). Insure that all lead wires are inside the timer assembly. 6 Program the timer according to instructions provided on page 6. 7 Connect the unit to electrical supply. 8 Start the circulator. 1. Pump 2. Terminal Box Base 3. Terminal Box Cover 4. Mounting Screw 5. Timer Box Cover 6. Timer Module Cover 6 fig. 1 - Astro 2 series circulator and 24-hour timer assembly drawing 5 Assembly - Exploded Layout 4 3 1 4 2 black white green black black black white green white black fig. 2 - Astro 2 series circulator and 24-hour timer wiring diagram 2 To mount the Astro Express 2 circulator: a Turn off water supply. If necessary, drain the hot water distribution pipes and partially empty the water heater. b Disconnect the hot water distribution pipe from the water heater outlet. c Connect the Astro Express 2 circulator inlet to the water heater outlet nipple. d Connect the distribution pipe to the circulator outlet. 3 To mount the Astro Express 2 circulator: a The circulator shaft is horizontal. b The clock/timer face is accessible for viewing and adjustment. c The direction of water flow matches the arrow on the circulator casing. d The piping is sufficiently rigid to support the system in operation. e Neither the clock/timer nor black terminal box is under the circulator. 4 If the arrow on the circulator casing is not pointing away from the hot water heater, see Rotating the circulator casing. 5 To mount the Astro Express lf valve: a Select the faucet to be controlled, typically the furthest faucet from the hot water heater. For multi-branch hot water piping runs, a valve may be required at the end of each branch for maximum effectiveness. b Disconnect the hot and cold supply pipes from the faucet. c Connect the hot and cold water supply to the Astro Express lf valve ½" threaded inlets (stainless steel flex hose recommended).

Astro Express 2 installation & 3 d Connect the hot and cold Astro Express lf valve W" threaded outlets to the faucet (stainless steel flex hose recommended). e Secure the valve to the wall under the sink, using the plastic wall anchor and screw. 6 Check the installation for leaks: a Ensure the faucet is closed. b Turn on the water supply. c Open the hot and cold water supply valves. d Open the faucet hot and cold taps to purge all air from the system. Close the faucet. e Inspect the circulator and valve connections for leakage. If a leak exists, close hot and cold supply valves until leaks are corrected. 7 To connect power to the circulator: a Verify that the timer s manual override switch is in the off position. b Plug the power cord into a standard 115 Vac household electrical receptacle. c To perform initial system test, see operation. 5.0 rotating the circulator casing Prior to connecting the system to the hot water piping, if alternate orientation of either the circulator discharge or clock timer is required, proceed as follows: 5 To verify the circulator shaft still spins freely: a Remove the plug from the end of circulator with a slotted screwdriver. b Insert the screwdriver in the slot in the end of the shaft. c Ensure the shaft turns freely and smoothly in both directions. d Replace the plug and gently tighten. 6.0 operation caution Never operate the system dry or permanent damage may occur to the circulator. Never shut off the water supply or restrict flow in any way while the circulator is operating. 1 Verify water is present at the circulator. 2 Verify the power cord is plugged into an appropriate household electrical outlet. 3 To continuously run the circulator or test for initial operation, set the manual override switch to the on position and verify the circulator operates smoothly and quietly. 4 For normal automatic operation, set the clock/timer as required and move the manual override switch to the auto position. 5 To prevent circulator operation (for example, when the occupants will be away from the residence for an extended period of time) set the manual override switch to the off position. f l o w flow 1 Remove the four hex socket head screws that hold the casing to the circulator. 2 Gently pull the casing from the circulator body, taking care not to damage the gasket or impeller. 3 Rotate the casing as required to meet circulator discharge and clock timer orientation requirements. 4 Tighten the four hex socket head screws evenly; ensuring the gasket seals the mating surfaces. 1 Rotate the dial in a clockwise direction until both the time shown, and the appropriate am or pm indicator, correspond to the current time of day. This adjustment is required for initial operation, following a power interruption, to adjust for daylight savings time, or for periodic time correction. 2 Remove the clear plastic cover from the dial. 3 The outer ring of the dial has an adjustable tab for each 15 minute time interval of a 24 hour day. To enable circulator operation for a specific time interval, slide the corresponding interval tab to the outer position. All tabs positioned toward the center of the dial disable circulator operation for those time intervals. 4 Verify the manual override switch is in the auto position. 5 Replace the clear plastic cover on the dial. 7.0 setting the clock/timer

installation & Astro Express 2 4 For maximum energy savings, set the timer to: 1 Activate the circulator at least ½ hour before initial hot water demand for the day is anticipated. 2 Deactivate the circulator when the anticipated hot water demand for the day ends. manual override switch positions on auto off current time interval tabs (15 minutes each) manual override 8.0 setting the valve The Astro Express lf valve is factory set to suit most applications. The valve may be easily adjusted to suit application conditions and personal preferences. 1 To increase the water temperature at the hot-water tap, turn the flowrate adjustment counter clock-wise one or two increments. 2 To decrease the water temperature at the cold-water tap, turn the flowrate adjustment clock-wise one or two increments. 3 To completely stop flow through the valve, turn the valve completely closed by turning the flowrate adjustment fully clockwise. If necessary to achieve the desired water temperature control, set the circulator timer to cycle the circulator on/off during the anticipated hot water demand period, in combination with valve adjustment. Allow ample time (at least several hours) after valve or timer adjustment, for the system temperature to stabilize, prior to evaluating the result of the adjustment. flowrate adjustment screw dial am/pm indicators supply hot faucet hot faucet cold supply cold

Astro Express 2 installation & 5 9.0 technical data astro express 2 circulator astro 220ssu Max. power consumption 33w, 0.29a Max. head 5.5 ft (1.7 m) Max. flow 10 gpm (0.63 L/s) Default operating speed Speed 3 Power requirements 115 Vac, 60 Hz Power connection 6.0 ft (1.8 m) power cord, molded duplex plug with ground Environment Indoor use only Max. working pressure 100 psi (689 kpa) Ambient temperature 39 f (4 c) to 104 f (40 ) Max. water temperature 140 f (60 c) Clock timer 12-hour analog clock with am/pm indication Timer settings Individual toggles for each 15 minute interval over 24 hours Manual override 3 position slide switch, on/off/auto Pump casing Stainless steel with 1¼" npsm union threads Impeller pa66 Shaft Ceramic Bearings Ceramic Union tailpieces Brass, O" fpt (two) and O" mpt (one) Union gaskets epdm (two) Approvals listed certified astro express lf valve Housing Internal components Connections Environment Flowrate adjustment Max. working pressure Max. water temperature Mounting Approvals Forged Eco brass* with noryl cap Stainless steel and plastic with epdm O-rings Threaded, ½" hot and cold inlets, W" hot and cold outlets Indoor use only 0 100%, multi-turn slotted screw 100 psi (689 kpa) 140 f (60 c) Plastic wall anchor with screw certified * Complies with section 116875 at the California Health and Safety Code and vermont Act 193 (lead content of wetted surface is 0.25% or less).

installation & Astro Express 2 6 10.0 replacement parts part description item number Astro 220ssu-t 110223B-244 O" fpt union lead free* hardware kit 810120-324 O" mpt Union lead free* tailpiece 810120-346 24-hour timer 810223B-130 Timer cover 110123-031 Astro express lf valve 561100LF-001 toronto +1 416 755 2291 buffalo +1 716 693 8813 birmingham +44 (0) 8444 145 145 manchester +44 (0) 8444 145 145 bangalore +91 (0) 80 4906 3555 shanghai +86 21 3756 6696 armstrong fluid technology established 1934 armstrongfluidtechnology.com