LC1350 Level Controller

Similar documents
BC3250. Blowdown Controller

LC2200 Level Controller Installation and Maintenance Instructions

LC3000 Level Controller Installation and Maintenance Instructions

- to scroll through the menus. - to increase digits when in a menu.

LC2610 Level Controller Installation and Maintenance Instructions

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

LC2650 Level controller

Process Alarm Module RTA 421

Electronic steam boiler controls

Commissioning password. This page MUST be removed after commissioning and kept in a safe, access controlled location.

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

PA ma Loop Powered Level Preamplifier

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Nov 08 PRODUCT SPECIFICATION SHEET

E340 BOILER CONTROL INSTALLATION MANUAL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

More Precision. indusensor // Linear inductive displacement sensors

UDC 700 Universal Digital Controllers and Indicator Specifications

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Software Version 2.01 LEVEL MONITOR MODEL 220

CMT MANUAL 6. NMC SENSORS

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

02/11/2015

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

More Precision. indusensor Linear inductive displacement sensors

RE-PR3-E-27 3-Phase Panel Mount 27kW

Series Temperature Controller Instruction Sheet

More Precision. indusensor // Linear inductive displacement sensors

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Turbimax CUE21 / CUE22

02/11/2015

More Precision. indusensor // Linear inductive displacement sensors

Pump-Up Controller MODEL 4062

Two-Channel Gas Controller

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

Pump-Down Controller MODEL 4052

Temperature Controllers

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

RS485 MODBUS Module 8AI

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

/8 DIN Level Indicator

UDC100 Universal Digital Controller Specifications

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Low Temperature Zirconia Oxygen Analyzer

DMFPM-2R MULTIFUNCTIONAL

C-Bus Four Channel General Input Unit Installation Instructions

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Carbon Monoxide Transmitter

Networkable Fan Coil Controller Specification and Installation Instructions

System 57. An advanced World of intelligent gas detection system management

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

VA301C CONTROLLER WITH BACnet OPTION

Process & TeMPerATUre UniversAl input DigiTAl MeTers

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

System 57. An advanced world of intelligent gas detection system management

General Specifications

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

P R O D U C T D ATA S H E E T

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Mobrey MCU900 Series Universal Control Unit

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

LORAIN CIP 4890/48120 DC Power System

Centro-Matic Automated Lubrication Systems System Controls

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Figure 1 DirectLine DL423 Sensor. Description, continued

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

High Pressure Conductivity Monitor

Rosemount 3490 Series

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

SET-2000 Hi Level/Oil

On the job around the clock 24/7: Fire detection systems

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

IGD.CO.UK

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

APPLICATION DATA SHEET

ACCS-30. Multipoint commercial heat-tracing control system

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

910 Series Single-point heat-tracing control system

Duct Air Quality Sensors

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Instruction Manual August sitrans CU 02

QPM21 Series Duct CO 2 and Air Quality Sensors

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Transcription:

LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump, valve or solenoid. It has been designed as an on/off level controller for use with the LP10-4 four-tip conductivity probe operating on supply voltages from 99 to 264 Vac. The controller is suitable for use with virtually all qualities of conductive liquids from salt solutions or boiler water to condensate having an electrical conductivity as low as 1 μs /cm at 25 C. (0.64ppm @ 77 F) The LC1350 gives accurate and reliable control under the very different conditions found in vessels, tanks or high output boilers operating up to 32 bar @ 239 C. (464psig @ 462 F) The front panel has a 3-digit LCD screen and moving segments that the liquid level rising or falling along with a five-button keypad. The unit can be panel, DIN rail or chassis mounted. Principal features: - controller with two configurable alarms. - Universal power supply 99 Vac to 264 Vac. - UL and TÜV approved. - LCD shows level change direction. - Interactive safety feature. - Infrared comms. Approvals This product complies with the Electromagnetic Compatibility Directive 2004 / 108 / EC and all its requirements. The LC1350 is suitable for Class A Environments (e.g. industrial). A fully detailed EMC assessment has been made and has the reference number UK Supply BH LC1350 2008. The LC1350 complies with the Low Voltage Directive by meeting the standards of: - EN 61010-1:2001 safety requirements for electrical equipment for measurement, control, and laboratory use. The LC1350 has been type-tested as a level control by meeting the standard: - Vd TÜV requirements for water level control and limiting devices, Water 100 (07.2006). Clamping screw LC1350 LCD Application Pump on Pump off High alarm - Low alarm Typical application example on/off control of a feedtank: Note: probes can be mounted in external chambers if boiler mounting is not possible. Function Inputs The LC1350 input options are: - High alarm or low alarm from a conductivity probe. - Pump on/off control from two conductivity probes. Function / outputs The controller reacts to a change in probe conductivity (open /closed circuit) and energises / de-energises a relay. This action switches a pump or sounds an alarm. Other features: - Additional filters can be selected to increase the damping effect for turbulent conditions. - To prevent unwanted or inadvertent changes being made, all commissioning parameters are protected with a fixed pass code. - The product can communicate via an infrared link between adjacent boiler house controllers. It is designated as a slave unit. - A panel mounted external test switch may be fitted if required. Clamping screw AL 5 button Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. TI-P402-132-US 07.10 15

LC1350 Controller Technical data LC1350 Power supply (104 F) Mains voltage range Power consumption General Maximum altitude Ambient temperature limits 99 Vac to 264 Vac at 50/60 Hz 7.5 W (maximum) Indoor use only 2 000 m (6 562 ft) above sea level 0-55 C (32-131 F) Maximum relative humidity 80% up to 31 C (88 F) decreasing linearly to 50% at 40 C Overvoltage category Pollution degree III 2 (as supplied) 3 (when installed in an enclosure) - Minimum of IP54 or UL50 / NEMA 3, 3S, 4, 4X, 6, 6P or 13. Enclosure rating NEMA type 4 hose down only (UL approval) and Environmental (front panel only) IP65 (verified by TRAC Global) LVD (safety) Electrical safety EN 61010-1 UL61010-1 CAN / CSA C22.2 No. 61010-1 EMC Immunity/Emissions Suitable for heavy industrial locations Enclosure Material Polycarbonate Front panel Material Silicone rubber, 60 shore. Solder Tin / lead (60 / 40%) Rising clamp plug-in terminal blocks with screw connectors. Termination Caution: Use only the connectors supplied by Spirax Sarco Ltd. Mains and Safety and Approvals may be compromised otherwise. signal connector Cable size 0.2 mm² (24 AWG) to 2.5 mm² (12 AWG). Stripping length 5-6 mm (0.2") Shield type probe cable / wire Number of cores 5 Input - probe (conductivity) Output relays Gauge Maximum length Switching conductivity Drive Contacts Voltage ratings (maximum) Resistive load Inductive load ac motor load High temperature Screened 1 1.5 mm² (18-16 AWG) 100 m (328 ft) Minimum conductivity 1 µs / cm @ 25 C (K = 0.22 (220 KΩ) ) when used with a Spirax Sarco LP10-4 probe. ac pulsed 2 x single pole changeover relays (SPCO) 250 Vac 3 amp @ 250 Vac 1 amp @ 250 Vac ¼ HP (2.9 amp) @ 250 Vac 1 / 10 HP (3 amp) @ 120 Vac Pilot duty load Electrical life (operations) Mechanical life (operations) 30 x 10 6 Physical layer C300 (2.5 amp) - control circuit / coils 3 x 10 5 or greater depending on load IrDA Baud 38 400 Output infrared Range 10 cm (4") Working angle 15 Eye safety information Exempt from EN 60825-12: 2007 Safety of laser products - does not exceed the accessible emission limits (AEL) of Class 1 Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 TI-P402-132-US 07.10 16

LC1350 Controller Safety information, installation and maintenance Warning: This document does not contain sufficient information to install the unit safely. The unit operates at a potentially fatal mains voltage. Before attempting to install the unit read the Installation and Maintenance Instructions supplied with it. In most countries, steam boilers operating with limited supervision require two self-monitoring level probes and controllers to provide two independent low level alarms. A high level alarm is also advised, and is compulsory in some countries. The LC1350 is not selfmonitoring. Do not install the product outdoors without additional weather protection. Do not attempt to open the product - it is sealed and has no replaceable parts or internal switches. Do not cover or obstruct the infrared beam between products. No special servicing, preventative maintenance or inspection of the product is required. water level controls and level alarms do, however, require testing and inspection. Dimensions / weight (approximate) in mm and g. Weight 430 g. (0.95 lb) 52 mm (2.05") 120 mm (4.72") LC1350 140 mm (5.51") 120 mm (4.72") AL How to specify Conductivity level controller to provide on/off control of a pump plus two configurable alarms, and to have infrared communications. How to order Example: 1 off Spirax Sarco LC1350 level controller. Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 TI-P402-132-US 07.10 17

Controller 18 Description The Spirax Sarco is a level controller for on/off or modulating control of conductive liquid levels. The has one alarm output that can be configured high or low. The controller is suitable for use with liquids having an electrical conductivity of 5 µs/cm or 5 ppm. The may be used on boilers, tanks, or vessels operating at up to 32 bar g at 239 C (464 psig@462 F). The front panel has a 3 digit LCD and a five-button keypad. The unit can be be panel, DIN rail, or chassis mounted. Principal features: - controller for modulating or on/off control of boilers. - Universal power supply 99 Vac to 264 Vac. - UL and TÜV approvals. - Alarm high or low. - Input filter for turbulent conditions. - 0/4-20 ma retransmit. - Infrared communications. Approvals This product complies with the Electromagnetic Compatibility Directive 2004 / 108 / EC and all its requirements. The is suitable for Class A Environments (e.g. industrial). A fully detailed EMC assessment has been made and has the reference number UK Supply BH 2008. The complies with the Low Voltage Directive by meeting the standards of: - EN 61010-1:2001 safety requirements for electrical equipment for measurement, control, and laboratory use. The has been type-tested as a level control by meeting the standard: - Vd TÜV requirements for water level control and limiting devices, Water 100 (07.2006). - UL Listed - open. Typical applications On/off control: - Pump control. - One alarm output. - 4-20 ma level output. Note: A solenoid valve may be used instead of a pump. Modulating control: Modulating valve control using valve motor drive or 4-20 ma control signals. - One alarm output. - 4-20 ma level output. Note: The 4-20 ma level output is only available when the product is configured for valve motor drive systems. Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. Graphic 5 button Function The product compares the input signals with the Set Point selected by the user. It then changes its output signal to control the water level in the boiler or tank. Inputs The product has two inputs to accept the following signals: - probe or transmitter 1-6 V or 4-20 ma. - A 1 K potentiometer input ~ for Valve Motor Drive (VMD). Outputs The output control signal can be configured / wired to work with a pump or a modulating control valve. It also provides a relay output for high or low level alarms and can provide an isolated 4-20 ma retransmission output. Other features: - An additional filter can be selected to increase the damping effect for turbulent conditions. - Commissioning parameters are protected with a pass code. - The can communicate via an infrared link between adjacent controllers. It enables the parameters to be passed to a product fitted with RS485 (User). The is designated as a slave unit no set-up or adjustment is needed. Important: Do not cover or obstruct the infrared beam between products. AL % Clamping screw Clamping screw TI-P402-133-US 07.10

Power supply (104 F) Mains voltage range Power consumption General Maximum altitude Controller Technical data Ambient temperature limits 99 Vac to 264 Vac at 50/60 Hz 7.5 W (maximum) Indoor use only 2 000 m (6 562 ft) above sea level 0-55 C (32-131 F) Maximum relative humidity 80% up to 31 C (88 F) decreasing linearly to 50% at 40 C Overvoltage category Pollution degree III 2 (as supplied) 3 (when installed in an enclosure) - Minimum of IP54 or UL50 / NEMA 3, 3S, 4, 4X, 6, 6P or 13. Enclosure rating NEMA type 4 hose down only (UL approval) and Environmental (front panel only) IP65 (verified by TRAC Global) Mains and signal connector LVD (safety) Electrical safety EN 61010-1 UL61010-1 CAN / CSA C22.2 No. 61010-1 EMC Immunity/Emissions Suitable for heavy industrial locations Enclosure Material Polycarbonate Front panel Material Silicone rubber, 60 shore. Solder Tin / lead (60 / 40%) Termination Cable size Stripping length 5-6 mm (0.2") Rising clamp plug-in terminal blocks with screw connectors. Caution: Use only the connectors supplied by Spirax Sarco Ltd. Safety and Approvals may be compromised otherwise. 0.2 mm² (24 AWG) to 2.5 mm² (12 AWG). High temperature Cable / wire Shield type Screened and probe Number of cores 3 connector cable / wire Gauge 1 1.5 mm² (18-16 AWG) data Maximum length 100 m (328 ft) Input technical data Twisted pair 4-20 ma Shield type Screened output Number of pairs 1 cable / wires Gauge 0.23-1 mm² (24-18 AWG) Maximum length Minimum voltage Maximum voltage Input impedance 100 m (328 ft) 0 Vdc or 1 V (with OUTRANGE function selected) 6 Vdc (absolute maximum = 7 Vdc) 28 KΩ Accuracy 5% FSD over operating range voltage Repeatability 2.5% FSD over operating range Resolution Sample time Minimum current Input impedance 14 bit (0.15 mv approximately) 260 Hz 0 ma 22 ma 11 KΩ 4-20 ma Accuracy 5% FSD over operating range Repeatability Resolution Sample time 2.5% FSD over operating range 14 bit (1 µa - approximately) 260 Hz Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 Spirax Sarco, Inc. 1997 TI-P402-133-US 07.10 19

24 Vdc supply Maximum voltage Ripple voltage Minimum current Controller 32 Vdc (no load, open circuit) 25 ma 10 mv @ 264 V, full load 0 ma 20 ma Open circuit voltage (maximum) 19 Vdc 4-20 ma Resolution 0.1% FSD Maximum output load Isolation Output rate 500 ohm 100 V 10 / second Contacts 2 x single pole changeover relays (SPCO) Output Voltage ratings (maximum) 250 Vac technical Resistive load 3 amp @ 250 Vac data Inductive load 1 amp @ 250 Vac Relays ¼ HP (2.9 amp) @ 250 Vac ac motor load 1 / 10 HP (3 amp) @ 120 Vac Pilot duty load Electrical life (operations) Mechanical life (operations) 30 x 10 6 Physical layer C300 (2.5 amp) - control circuit / coils 3 x 10 5 or greater depending on load IrDA Baud 38 400 Infrared Range 10 cm (4") Safety 1 information, installation Working angle 15 Eye safety information and maintenance This document does not contain sufficient information to install the unit safely. The unit operates at a potentially fatal mains voltage. Before attempting to install the unit read the Installation and Maintenance Instructions supplied with it. Technical data (continued) Exempt from EN 60825-12: 2007 Safety of laser products - does not exceed the accessible emission limits (AEL) of Class Dimensions / weight (approximate) in mm and g. Weight 430 g. (0.95lb) 52 mm (2.05") 120 mm (4.72") The product must be installed in a suitable industrial control panel or fireproof enclosure to provide impact and environmental protection. A minimum of IP54 (EN 60529) or 3, 3S, 4, 4X, 6, 6P and 13 (UL50/NEMA 250) is required. The product may be installed on a DIN rail, a chassis plate, or in a panel cut-out. A bezel is supplied. % 140 mm (5.51") 120 mm (4.72") Install the product in an environment that minimises the effects of heat, vibration, shock and electrical interference. Do not install the product outdoors without additional weather protection. Do not attempt to open the product - it is sealed and has no replaceable parts or internal switches. AL Do not cover or obstruct the infrared beam between products. No special servicing, preventative maintenance or inspection of the product is required. water level controls and level alarms do, however, require testing and inspection. How to specify controller with auto voltage sensing, alarm that can be configured high or low, and infrared communications. How to order Example: 1 off Spirax Sarco level controller. 20 Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 TI-P402-133-US 07.10

LC2650 Controller Description The Spirax Sarco LC2650 is a level controller for conductive liquids. It provides on/off or modulating control of liquid levels in boilers, tanks, and vessels operating up to 32 bar at 239ºC (464 psi@462ºf). It has two alarm channels that can be independently configured either high or low. The controller is suitable for use with liquids having an electrical conductivity as low as 5 μs/cm or 5 ppm (when used with an LP20 or PA20 capacitance probe). The front panel has an LCD screen and a five-button keypad. The LCD screen can show either operating information (in run mode), or a trend graph that s a record of the variation in level over a set time. In run mode the general data is shown on several consecutive screen s. A test function provides the operator with a diagnostic feature. Inputs can be measured and outputs can be set from the front panel. To prevent unwanted or inadvertent changes being made, all commissioning parameters are protected with a pass code. The LC2650 can communicate via an infrared link between adjacent controllers. LC2650 SP PV AL 100 50 0 % Clamping screw Graphic 5 button Clamping screw It can be designated as either a master unit or a slave unit. The LC2650 can be panel, DIN rail or chassis mounted. Principal features: - Modulating or on/off control of boiler water level using a capacitance probe. - Switchable integral action. - Single, two or three-element control. - LCD graphics and five-button keypad. - Graphic of status, PV percentage, and alarm, plus a trend graph. - Infrared communication. - EIA 485/Modbus communications. Approvals This product complies with the Electro magnetic Compatibility Directive 2004 / 108 / EC and all its requirements. The LC2650 is suitable for Heavy Industrial environments. A fully detailed EMC assessment has been made and has the reference number UK Supply BH LC2650 2008. The LC2650 complies with the Low Voltage Directive by meeting the standards of: - EN 61010-1:2001 safety requirements for electrical equipment for measurement, control, and laboratory use. The LC2650 has been type-tested as a level control by meeting the standard: - Vd TÜV requirements for water level control and limiting devices, Water 100 (07.2006). - UL listed (open). Applications The product can be configured to control the level of a boiler, tank or vessel, by operating a pump, valve or solenoid. Typical applications: On/off control: - Pump control. - Two alarm outputs. - 4-20 ma level output (isolated). Note: A solenoid valve may be used instead of a pump. Modulating control: Modulating valve control using valve motor drive or 4-20 ma control signals. - Two alarm outputs. - 4-20 ma level output (isolated). Two or three element modulating control: Modulating valve control using a valve motor drive or 4-20 ma control signal. - Two alarm outputs. - 4-20 ma level output (isolated). - Feedback from steam flowmeter. - Feed forward from water flowmeter. Inputs / Function The product compares the input signals with the set point selected by the user. It then changes its output signal to control the water level in the boiler or tank. Outputs The product control signal can be configured / wired to work with a pump or a modulating control valve. It also provides relay outputs for high and low level alarms and can provide an isolated 0-20 ma or 4-20 ma retransmission output. Parameters can be remotely accessed via the RS485 / MODBUS communications. Other features An additional filter can be selected to increase the damping effect for turbulent conditions. 22 Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. TI-P402-134-US 07.10

Power supply Mains voltage range Power consumption General Maximum altitude LC2650 Controller Technical data LC2650 Ambient temperature limits Maximum relative humidity Overvoltage category Pollution degree 99 Vac to 264 Vac at 50 / 60 Hz 7.5 W (maximum) Indoor use only 2 000 m (6 562 ft) above sea level 0-55 C (32-131 F) 80% up to 31 C (88 F) decreasing linearly to 50% at 40 C(104 F) III 2 (as supplied) 3 (when installed in an enclosure) - Minimum of IP54 or UL50 / NEMA 3, 3S, 4, 4X, 6, 6P or 13. Enclosure rating NEMA type 4 hose down only (UL approval) and Environmental (front panel only) IP65 (verified by TRAC Global) Mains and signal connector Electrical safety EN 61010-1 LVD (safety) UL61010-1, UL 508, Clause 23.2. CAN / CSA C22.2 No. 61010-1 EMC Immunity / Emissions Suitable for heavy industrial locations Enclosure Material Polycarbonate Front panel Colour Material Solder Tin / lead (60 / 40%) Termination Cable size Stripping length 5-6 mm (0.2") Pantone 294 (blue) Silicone rubber, 60 shore. Rising clamp plug-in terminal blocks with screw connectors. Caution: Use only the connectors supplied by Spirax Sarco Ltd. Safety and Approvals may be compromised otherwise. 0.2 mm² (24 AWG) to 2.5 mm² (12 AWG). High temperature probe, Shield type Screened feedback, Number of cores 3 (LP20/PA20), 2 or 3 (4-20 ma Transducer) steam meter and water Gauge 1 1.5 mm² (18-16 AWG) cable / wire Maximum length 100 m (328 ft) Recommended type Shield type Prysmian (Pirelli) FP200, Delta Crompton Firetuf OHLS Twisted pair Screened 0/4-20 ma output(s) Number of pairs 1 cable/wire Gauge 0.23-1 mm² (24-18 AWG) Maximum length Shield type 100 m (328 ft) EIA RS485 twisted pair Screened RS485 communication Number of pairs 2 or 3 cable / wire Gauge 0.23 mm² (24 AWG) Maximum length 1200 m (4000 ft) Recommended type Alpha Wire 6413 or 6414 LAN Cat 5 or Cat 5E ScTP (screened), FTP (foil) or STP (shielded) cable can be used, but limited to 600 m. Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 TI-P402-134-US 07.10 23

LC2650 Controller Minimum voltage Maximum voltage Input impedance Accuracy voltage Repeatability Resolution Sample time Minimum current Input Input impedance 110 Ω technical 4-20 ma Accuracy 5% FSD over operating range 0 Vdc or 1 V (with OUTRANGE function selected) 6 Vdc (absolute maximum = 7 Vdc) 28 kω 5% FSD over operating range 2.5% FSD over operating range 14 bit (0.15 mv approx) 260 Hz 0 ma 20 ma data Repeatability 2.5% FSD over operating range Resolution 14 bit (1 µa approximately) Sample time 260 Hz Minimum alarm level Minimum recovery level 'out of range' Maximum alarm level alarm-voltage Maximum recovery level Minimum alarm level Minimum recovery level 'out of range' Maximum alarm level alarm-current Maximum recovery level Technical data LC2650 (continued) < 0.2 Vdc > 1 Vdc > 6.5 Vdc < 6 Vdc < 2.5 ma > 4 ma > 21 ma < 20 ma 32 Vdc (no load, open circuit) 25 ma 10 mv, full load 0 ma 22 ma Maximum voltage 24 Vdc supply Ripple voltage Minimum current Open circuit voltage (maximum) 19 Vdc 4-20 ma Resolution 1% FSD Maximum output load 500 ohm Isolation 100 V Output rate 10 / second Contacts 2 x single pole changeover relays (SPCO) Voltage ratings (maximum) 250 Vac Resistive load 3 amp @ 250 Vac Output Inductive load 1 amp @ 250 Vac technical Relays ¼ HP (2.9 amp) @ 250 Vac ac motor load data 1 / 10 HP (3 amp) @ 120 Vac Pilot duty load C300 (2.5 amp) - control circuit / coils Electrical life (operations) 3 x 10 5 or greater depending on load Mechanical life (operations) 30 x 10 6 Physical layer RS485 4-wire full or 2-wire half duplex Protocol Modbus RTU format RS485 Isolation 60 Vac/dc Receiver unit load (256 devices - maximum) Output rate Up to 10 frames / second Physical layer IrDA Baud 38 400 Infrared Range 10 cm (4") Working angle 15 Eye safety information Exempt from EN 60825-12: 2007 Safety of laser products - does not exceed the accessible emission limits (AEL) of Class 1 Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Phone: (803) 714-2000 Fax: (803) 714-2222 TI-P402-134-US 07.10 24