ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Similar documents
ZXSe Range Data Sheet

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The EN54 Part 2 & 4 Fire System

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Components Brochure DX CONNEXION

The EN54 Part 2, 4 and 13 Fire System

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

ID2000. intelligent fire alarm panel

ID50series. intelligent fire alarm panels

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING...

Advanced FireAlarm Panel 1-4Loop

ID3000 intelligent. fire alarm panel

Reliably Advanced Extinguishing Control

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

intelligent fire alarm ID60series panels

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING...

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Product Data Sheet. Remote Terminals. Features:

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

ID3000 intelligent. fire alarm panel

Intelligent Security & Fire Ltd

Saxon Range 1-8 Zone Convertional Control Panels

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Document No Issue 4 user manual

INTELLIGENT FIRE ALARM CONTROL PANEL

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Fire control panels FC360

Intelligent Security & Fire Ltd

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Installation, Operating and Maintenance Manual

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire control panels FC726 FC726-XA

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Reliably Advanced Extinguishing Control

Intelligent Single Loop Fire Alarm Control Panel

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

The Leading Multiprotocol Intelligent Fire Panel

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Intelligent addressable fire alarm control panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Touch Screen 1 loop Addressable Fire Alarm Panel

FC700A Fire detection control unit

Vigilant MX4428 Fire Alarm System

Document No Issue 4 product manual

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Solution F2. Fire Alarm Control Panels one step ahead.

ZSC100 Gas Detection and Alarm System Controller

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

user manual Document No , Revision 03 November 2015

Addressable Fire Alarm Control Panel

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

TrueAlarm Fire Alarm Controls

SOLO Single Loop Addressable Fire Control Panel

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Wireless Fire & Security Solutions. Fire Product Showcase

NETWORK FIRE ALARM CONTROL PANEL. Features

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Excel-EN Conventional Fire Control Panel

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Security Alarm Systems

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

The supplier and installer of the system should be approved by the local civil defence authority.

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Welcome to Morley IAS Fire Systems

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

FIRElux Emergency Lighting

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ACP10 & ACP50 Security Systems

MINERVA MX. 800 Series Ancillary Equipment

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

DS7400Xi Addressable Control/ Communicator

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

System 800 Addressable Fire Detection & Alarm System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

IGD.CO.UK


Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Application Guide 001

QA16 Addressable System

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Analogue Addressable Fire Panel Range

FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators reference guide

Transcription:

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options Fully On-Site Programmable, "Auto Learn" Facility Off-Line Configuration Facility Automatic Test Mode Integral Or External Serial Printer Option Multiple Language Support Support For Morley-IAS, System Sensor, Apollo (Series 90, XP95 And Discovery), Hochiki And Nittan Protocols GENERAL The ZXe intelligent multi protocol fire alarm control panel provides a cost-effective platform for a fire alarm system that is both flexible and expandable. The ZXe offers system designers and end users a technically sophisticated range of facilities and functions whilst maintaining ease of programming, installation, and operation. The ZXe control panel can support Morley-IAS, System Sensor, Apollo (Series 90, XP95 and Discovery), Hochiki and Nittan protocols. This makes the ZXe the perfect solution for retrofit jobs as well as new projects. 710-001 ZXE intelligent multi protocol fire alarm control panel Morley-IAS's own graphical display program 795-043-485. Each panel supervises its own detection system and is designed to function independently of all others in the network in case of a communication failure. A full range of passive and active repeater panels and serial peripheral devices, complements the ZXe. A mixture of 31 RS485 serial peripheral bus devices, can be connected to one ZXe panel. Each ZXe control panel can support up to five analogue addressable loops. Each loop can support up to 99 analogue sensors and 99 modules with Morley-IAS and System Sensor protocols, giving the ZXe a maximum capacity of 990 addresses. With all other protocols, each loop supports up to 126 addresses thus giving a maximum ZXe capacity of 630 addresses. The ZXe can be networked with other ZXe and ZXa intelligent multi protocol fire alarm control panels using Master-Slave architecture. Furthermore, if a graphic based PC front end is required, the panels can be connected to 709-101 PASSIVE REPEATER 709-001 ACTIVE REPEATER 1 Lit. No: 990-019-100 REV.1 02-00

System The ZXe will control a combination of up to 99 heat, smoke or multi-criteria sensors on each loop and a combination of 99 call points, monitor, control, conventional zone interface modules and addressable sounders using Morley-IAS or System Sensor loop. When used with Apollo, Hochiki and Nittan loop controllers each loop supports up to 126 devices (detectors and modules). Depending on the arrangement of user specified zones, isolation modules may also be added to the system although they are not required at loop ends. The same protocol must be used in a ZXe panel. Different protocols cannot be used in the same panel. In multi-loop systems, the loops are scanned simultaneously. System Configuration The ZXe can be fully programmed on-site using the multifunction alphanumeric keypad and the three programming keys (YES, NO, ENTER). The AUTO LEARN facility saves considerable time and effort when installing a system, or when changing sensor configuration. It allows the system to learn for itself what devices have been installed on a particular loop. Alternatively the ZXe can also be programmed using PCLINK; the PC based Upload/Download software. This option allows for the engineer to connect a laptop PC to the control panel through a dedicated serial port (Port A) and upload panel configuration, make alterations in the installation information, and finally download the new configuration into the panel. This is particularly convenient for panels or systems when significant amounts of location text, or complex cause and effect patterns are required. Communication The ZXe control panel can support up to three optional serial communication ports. These are identified as Port B, Port C and Port D. Port B and Port C can be installed as RS485 or RS232 links and support PC front-end and panel network connections. Port D is used for peripheral devices only and must be an RS485 link. A fourth serial port, Port A, is reserved for PC (for programming) or local printer connection. Serial Peripheral Devices A full range of repeater panels and serial peripheral devices complements the ZXe. These devices are connected to the panel through optional serial RS485 port, Port D. Up to thirty one peripheral loop devices can be connected to one ZXe. The ZXR5 Active Repeater is a compact repeater unit, which mimics all the main indications and controls on the ZXe. It has an LCD, 6 general status LEDs and four control switches for Accept/Mute, Silence/Resound, Sound Alarms and System Reset. The ZXR4 Passive Repeater is a compact repeater unit, which mimics all the main indications on the ZXe. It has an LCD display and 6 general status LEDs. An internal printer may be connected to the ZXe alternatively a remote printer can be connected on the RS485 peripheral bus. Typical System Configuration For custom mimic panels, a programmable 40-way LED driver board is also available. Any other third party devices and systems can be easily connected to ZXe using the 8-way input and 4-way output cards. 2

Displays and Printer The ZXe has 14 general panel status information warning LEDs and an alphanumeric liquid crystal display with 2 lines by 40 characters. The display is illuminated to assist viewing under dim ambient light conditions. In addition to the general status LEDs and the LCD display, the ZXe comes with 20 pairs of zone status indicators as standard ("FIRE" and "FAULT/TEST/DISABLED" indications). 20 and 60 zone extender boards give the ZXe a zone indication capacity of 40 zones or 80. User definable text messages can be read directly from the LCD to give details of fire and fault event locations. Optional panel functions and more detail about events and devices can be accessed using the numeric keypad and following the menu driven user level options on the LCD. Additionally, when the optional printer is used, this information can be printed to provide a hard copy. Networking The ZXe can be networked with other ZXe and ZXa panels using Master/Slave architecture. Up to 13 panels can be inter-connected. The networks can be configured in two basic ways: a. Shared Zone Network: The panels act as one large system sharing zones and functions. For single site/building applications. b. Report and Control Network: The panels work individually or as sub-systems networked for reporting and control purposes only. For multiple site/building applications. Several sub-networks can be inter-connected using dedicated Superior Master and Sub-Master panels (ZXe only). When using this configuration up to 99 panels can be inter-connected. The LCD serves as the primary user interface when using the manual programming option. When the numeric keypad is not in use, the display reverts to automatically scrolling through any fire alarm or fault conditions present on the panel. Protection User controls on the front panel are password protected. Pressing any key on the panel will prompt for the appropriate level password to be entered. Authorised access to higher level functions including device isolation and configuration data entry is available through the panel keyboard and is again password protected. All configuration data and event logging is retained by nonvolatile memory and is, therefore, protected against corruption or complete failure of all external power supplies. System reliability is optimised by running a fault diagnosis program, which identifies problems, which may not be found during normal system testing. 3

SPECIFICATIONS Operating Voltage: 110V 60Hz AC or 230V 50Hz AC (+10%, -15% voltage tolerance) Max. PSU Rating: 3.25 Amps total, comprising: Battery Charger: Internal & External Loads: Standby Batteries: 24V sealed lead acid batteries 1.0 Amps 2.25 Amps External Outputs: Sounder Outputs: 4 programmable outputs. Open and short circuit monitoring. 1A maximum per output. Auxiliary Relays: EN54 format at 1 fault relay and 1 programmable relay voltage free, changeover outputs Contacts rated at 24V AC/DC, 1A, 0.6 pf maximum User Controls: MUTE/ACCEPT SILENCE/RESOUND SOUND ALARMS SYSTEM RESET All controls are protected by password control. Minimum Capacity: 2x 12V 12Ah Maximum Capacity: 2x 12V 25Ah Power Supply: Input(s): 24V and 7V AC (from integral mains transformer) (internally fitted) (internally fitted) Programming Controls: Alphanumeric multi-level keypad with 15 keys and three control keys: YES, NO (CANCEL/ESC), and ENTER Indicators: LED type general panel status indicators: Output(s): 24V, +1.5V, and -1.5V DC Dimensions: 500mm (19.7 ) W x 500mm (19.7 ) H x 180mm (7.1 ) D Weight: 17.0 kg (37 lbs) without batteries 34.5 kg (76 lbs) with 2x 25Ah batteries Environmental Operating Limits: Temperature: 0 C to +49 C (37 F to 120 F) Humidity: 10% to 93% non-condensing Construction: Sheet steel painted, sealed to IP41 Front panel: flush PVC fascia Recess mount bezel available. Cable Entry: 24x 20mm (0.8 ) knock-outs in top of cabinet 24x 20mm (0.8 ) knock-outs in bottom of cabinet Loop Capacity: 1 to 5 loops expandable Morley-IAS and System Sensor Protocols: Max. 99 sensor and 99 module addresses per loop Apollo, Nittan and Hochiki Protocols: IMPORTANT NOTE! Multiple sensor protocols cannot be used in the same panel simultaneously. Max. 126 devices (detectors and modules) per loop Zones: Up to 20 zones fitted with individual LED indicators Expandable to 40 and 80 Zones with optional LED indicator boards A maximum 120 zones can be programmed with up to 40 software zones with no LED indication Internal Sounder: Intermittent buzzer indicates a fault condition High-pitched continuous buzzer indicates a fire condition FIRE (Twin LEDs) FAULT ACCEPTED DISABLEMENT TEST SOUNDER FAULT DELAYED MODE RELAYS DISABLED EARTH FAULT SYSTEM/CPU FAULT SOUNDERS DISABLED ALARMS SILENCED SUPPLY FAULT POWER LED type zone Indicators (for 20 zones): FIRE FAULT/TEST/DISABLED Display: 2x40-character LCD alphanumeric display with back-light Serial Interface: 3 serial ports with connections for optional RS485 or RS232 plug-in communication modules. Port B and C: used for central front-end and network communication. RS485 or RS232. Port D: used for communication with peripheral devices. RS485 only. Port A: Dedicated serial port for software Upload/ Download or printer connection. Networking: Maximum of 13 panels can be networked using one Master (ZXe only) and 12 Slave (ZXa or ZXe) panels Maximum 99 panels can be networked using a Master Network and connected Sub-Networks. Approvals: CE UL (please order UL Listed versions) 4

Ordering Details: Module Type 1 to 5 Loop Addressable Panel, 20 zone LEDs, 230VAC, English 1 to 5 Loop Addressable Panel, 20 zone LEDs, 110VAC, English Europe (EN54) UL Listed 710-001 710-301 NS 710-201 Accessories: Module Type Europe (EN54) UL Listed Plug-In Loop Driver Modules (supports one loop): Morley-IAS Loop Card TBA TBA System Sensor Loop Card 795-068 794-068 Apollo Loop Card (Series 90) 795-048 NS Apollo Loop Card (XP95 and Discovery) 795-066 794-066 Hochiki Loop Card 794-058-003 794-058 Nittan Loop Card 795-044 NS Plug-In Serial Communication Modules: RS-232 Communication Module 795-005 794-005 RS-485 Communication Module 795-004 794-004 Hi-485 High Integrity RS485 Loop Module 795-038-001 794-038 P Peripheral Devices: ZXR5B Active Repeater 709-001 709-201 ZXR4B Passive Repeater 709-101 709-301 4-way relay module 795-014 NS 4-way sounder module 795-015 794-015 8-way input module 795-029 NS Modbus Interface (boxed) 795-057 NS Self-contained external printer, 110VAC NS 794-060-001 P Self-contained external printer, 230VAC 795-060-002 794-060-002 P 40-way mimic (LED) driver 795-065 794-065 P Pager interface module 795-067-001 NS Power Supply Units: 3A, 24Vdc PSU with charger and sounder 795-016 794-071 P booster, boxed, 230VAC 8 Amp boxed PSU, 230VAC 795-063 NS 8 Amp Chassis mounted PSU, 230VAC 795-064 NS Software: PC-LINK Programming Tool c/w Cable Adaptor 795-023 Windows graphical front end software c/w dongle 795-043-485 NS and RS485 converter Panel Accessories: Zone LED Expansion Board (20 LEDs) 795-069-020 794-071 P Zone LED Expansion Board (60 LEDs) 795-069-060 794-069-060 ZXe Flush Mounting Bezel 797-016-001 Battery Box (500mmx185mm) 797-025-001 795-060-002 External Printer 795-065 40-way remote mimic (LED) driver 795-029 8-way input module 795-015 4-way sounder module NOTES: NS = Not supported P = Pending TBA = To be announced 795-014 4-way relay module 5

ZX Network Typical Configuration: Morley-IAS Fire Systems (UK) Morley-IAS International YOUR LOCAL DISTRIBUTOR: Suite 2, Cheviot House Charles Avenue Beaminster Way East, Kingston Park Burgess Hill Newcastle Upon Tyne NE3 2ER West Sussex RH15 9UF United Kingdom United Kingdom Tel: 0191 2146444 Fax: 0191 2146333 Tel: 01444 235556 Fax: 01444 254410 Lit. No: 990-019-100 REV.1 02-00