Mustang Vaporizer. Installation, Operation & Maintenance MV

Similar documents
Installation, Operation, & Maintenance Manual. MODEL: MPRVSS (NGL Sr.), MPRVSSJR (NGL Jr.)

WARNING This is a Warning statement that is related to the use of this heater. These statements warn of actions that may result in physical injury.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

Retractable ph/orp Sensor

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Model Q45P/R. ph/orp Monitor...

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Safe Operation Manual. Honeywell IQ Force Gas Detector

INTRODUCTION / TABLE OF CONTENTS

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Sitron s CF Line of Flow Switch Monitors

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

RK / RK Methane Detector Operator s Manual

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Model Q45P/R. ph/orp Monitor...

WATLOW ELECTRIC MANUFACTURING COMPANY Installation & Maintenance Manual for ECO-HEAT Heaters I&M MANUAL No: Page: 1 Date: 3/15/2017 Rev: 4

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

OPTIWAVE X500 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Process Gas Chromatograph

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Genie Heated Regulator Installation & Operation Instructions

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

FLT93 Installation, Operation and Troubleshooting Guide

INSTRUCTION MANUAL (ATEX / IECEx)

RK/ RK Combustible Gas Detector Operator s Manual

BD Viper Lysing Heater Manual (for BD Viper System)

Description. Applications

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

RAEGuard 2 PID. User Guide

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

User s Manual YTA610 and YTA710 NEPSI Certification

Electronic Flow Switches

Certificate of Compliance

Dräger Polytron 8100 EC Detection of toxic gases and vapors

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

WATLOW ELECTRIC MANUFACTURING COMPANY

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Process Gas Chromatograph

PUV, PIR and PFO Series BROCHURE

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Cabinet Cooler Systems

RK-03 Hydrogen Detector Operator s Manual

Rosemount Analytical MODEL 7D THERMAL CONDUCTIVITY ANALYZER EXPLOSION PROOF INSTRUCTION MANUAL J1

Model 144H. Product Data Sheet , Rev DB February Content

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Models: GW/R-T GW/R-2-T GW/R-3-T

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Non-RTD Hot Melt Hose Replacement

Certificate of Compliance

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

SAVE THESE INSTRUCTIONS

RK-05 Carbon Monoxide Detector Operator s Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Restek s Electronic Leak Detector

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

RK-05 Combustible Gas Transmitter Operator s Manual

805QS Pressure Switch-Transmitter

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Circulation Heaters Selection Guidelines

IMPORTANT SAFETY INFORMATION READ ALL...

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

INLINE DI HEATER. Operation / Maintenance Manual

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

VERSAFLOW VORTEX Supplementary instructions

RK / RK CO 2 Detector Operator s Manual

Ar-Mite TM Low Flow Armored Flowmeter

Model No: Little Devil II (inc ss)

INSTALLATION HANDBOOK:

Chapter 8: Troubleshooting. 8: Troubleshooting 8 TROUBLESHOOTING... 3

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

21-light Remote Annunciator. Owner s Manual

Using the Model 1500 Portable Chilled Mirror Hygrometer

Transcription:

Mustang Vaporizer Installation, Operation & Maintenance MV

TABLE OF CONTENTS Safety Warnings 3 Product Features 4 Technical Specifications 5 Product Dimensions & Parts 6 Electrical Wiring Diagrams 8 Installation Instructions 10 Operation Instructions 11 Maintenance Instructions 11 2

SAFETY WARNINGS Failure to abide by any of the safety warnings could result in serious injury or death. Sealing fitting must be installed with access allowing the dams to be made and the sealing compound to be properly poured. Electrical power must be OFF before and during installation and maintenance or personal injury may result. Do not exceed any equipment pressure ratings. Surface temperatures will approach temperature limit specified in technical specifications. Gloves may be required for handling or adjustment. Select a mounting location so that the enclosure will not be subjected to impact by heavy objects. Impacts can damage enclosed devices. The hazardous location information specifying class and group listing on each instrument enclosure is marked on the nameplate of each enclosure. All unused conduit openings must be plugged. Plugs must be a minimum of 1/8 thick and engage a minimum of 5 full threads. 3

PRODUCT DESCRIPTION The Mustang Vaporizer (MV ) flash vaporizes liquid samples for introduction into gas analysis systems. Liquid samples are maintained near line conditions until reaching a flash chamber within the vaporizer, preventing pre-vaporization. The energy for vaporization is provided by an electric cartridge heater with sufficiently large surface area to maintain a stable gas temperature throughout the process. APPLICATION The MV is designed for flash vaporization of liquid samples including LNG, NGL, or other cryogenic liquids in petrochemical, refinery, liquefaction, or natural gas processing plants. FEATURES Thermal cutoff Versatile conduit connections Integral heater and controller Integral flow restrictor on inlet Compatible with Mustang Intelligent Vaporizer Sampling System - Model 1 & 2 for LNG BENEFITS Heater cartridge does not contact sample fluid Provides five times more heat transfer capacity than vaporizing regulators Uniform liquid flash vaporization No premature flashing or partial fractionation 4

TECHNICAL SPECIFICATIONS Maximum Allowable Working Pressure Proportional Temperature Control Range Port Sizes Conduit Connection Internal Volume 3500 psig (241.3 bar) 0 to 500ºF (-17 to 260ºC) 1/4 female NPT 3/4 female NPT 40 cc Thermal Cut-off Normally opens at 284 o F (140 o C) (other ranges available upon request) Wetted Materials Machined parts: 316 stainless steel/nace compliant All other metal parts: stainless steel/nace compliant Electrical Enclosure Classification Class 1, Division 1 & 2, Groups C, D, T3 Controller Watlow Input Supply Voltage 115 VAC, 415 Watts, 50/60 Hz 208/230 VAC, 415 Watts, 50/60 Hz Seal Viton Certification Kalrez other materials available upon request C - cetlus 5

PRODUCT DIMENSIONS & PARTS 1 2 3 4 5 6 Item Number QTY Description 1 1 Flow Adjuster BILL OF MATERIALS 2 2 Inlet Port (Optional Speed Loop) 3 1 Outlet Port 4 1 Flash Vaporization Chamber Contains: Heater; Cartridge, 350W/120V/208V/230V Thermocouple; Type J (2) Cut Off Switch; Thermal, Selco, P/N UP61-110C OR UP61-130C Enclosure; Killark GR0M0D 4GRB CEN OR Equal Wire; High Temp Heat Shrink Boot; Teflon, Small 2 Heat Shrink Boot; Teflon, Large 5 1 Sealing Fitting; Rated Exd IIC by Notified Body Nipple; 3/4, Rigid Conduit, Close Nipple; Threaded, Rigid Conduit, 2 Long 6 1 Temperature Controller Bracket; Controller 6

HOT SURFACE SSS SEE NOTES 2&3 Front View Top View NOTES: 1. ASSEMBLY IS THE SAME FOR ALL VOLTAGES (120/208/230 VAC). 2. TAG HOT SURFACE. SSS 3. TAG IS MARKED ON 304 OR 316 SS BY ETCHING OR OTHER MEANS. 4. HAZARD LOCATION ENCLOSURE SPECIFICATIONS ARE ON DWG #MST-GRB-LABEL. 5. CONDUIT SEAL FITTING TO BE POURED BEFORE PLACING IN A HAZARDOUS AREA SERVICE. TEMPERATURE CONTROLLER ENCLOSURE SPECIFICATION Outlet box for hazardous locations Class 1, Groups B, C, D CE Ex 11 2 g Ex d llc. T6-30 Max, T5-40 Max Gb IP66 CAUTION: TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE EQUIPMENT FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP ASSEMBLY TIGHTLY CLOSED WHEN IN OPERATION. 7

ELECTRICAL & WIRING DIAGRAMS 8

9

INSTALLATION INSTRUCTIONS NOMENCLATURE MAOP Maximum Allowable Operating Pressure LNG Liquid Natural Gas BTU British Thermal Unit TOOLS REQUIRED Standard Hand Tools Battery Powered Impact Wrench INSTALLATION 1. The MV is mounted in a vertical position with the sample flowing down through the unit. 2. Connect the tubing inlet and outlet fittings to the respective ports. Plug any unused ports. 3. Mount the MV assembly in accordance with previous cautions and warnings. 4. Perform the electrical hook up with de-energized conductors. 5. Verify the unit that you are hooking up to matches voltage wise with the power supply that you are connecting. Damage to the unit can occur if the wrong source power is applied. 6. A seal fitting is required for the power input connection to the controller enclosure to maintain its electrical hazard classification rating. 7. For 120 volt single phase input power: connect the hot wire to wiring terminal #1. Connect the Neutral wire to wiring terminal #2. Connect the earthing (ground) wire to the green screw in the bottom of the enclosure. 8. For 208 or 230 volt single phase input power: connect one hot wire to wiring terminal #1. Connect the Neutral to wiring terminal #2. Connect the second hot wire to wiring terminal #2. Connect the earthing (ground) wire to the green screw in the bottom of the enclosure. 9. A seal fitting is required between the controller enclosure and the MV. 10. Externally connect earthing (grounding) conductors from assembly to equipment ground connections. 11. Connections from the controller to the vaporizer are pre-wired from the factory. If replacement or troubleshooting is required, refer to the electrical schematic supplied with the unit. ADJUST THE TEMPERATURE SET POINT The temperature controller comes from the factory set to 250 F (121 C) unless otherwise specified. If a different temperature is required, refer to the Watlow Temperature Controller operation manual for the complete setup and adjustment procedures. START-UP PROCEDURE 1. Close the cover on the controller enclosure. 2. Turn on the electrical supply to the controller. 3. Allow a few minutes for the system temperature to stabilize. 4. Seal the conduit seal fittings if the controller is functioning as desired. 10

OPERATION INSTRUCTIONS 1. Verify that the sample stream supply is shut off. 2. Verify that the power to the controller is off. 3. Install the Watlow supplied software (EZ-ZONE Configurator) on a laptop or other computer. 4. Connect to the Watlow controller using a RS-485 adapter (B&B Electronics Model 485SD9 TB or equal). Plug the adapter into the serial port. Select the serial port on the computer to be used (i.e. COM 1-COM17). The other end connects to the RS-485 terminals. 5. On the computer, start program EZ-ZONE Configurator. 6. Turn power on to the controller. 7. Establish communication with the Watlow controller. 8. Set its address to 1 or user preference. 9. Set the regulator temperature set point to the recommended temperature. 10. Set the vaporizer temperature set point to the recommended temperature. 11. For all other Watlow parameter settings, refer to the EZ-ZONE User s Manual. 12. Slowly turn in the sample fluid low to full open to the regulator. 13. Adjust the regulator adjusting screw to obtain the desired output pressure. 14. Once sample fluid is being regulated, monitor the regulator temperature to verify that the controller is maintaining the set point temperature. 15. Verify the pressure and flow to the remote gas chromatograph or analyzer. 16. Once the flow is correctly established to the analyzer or gas chromatograph, document the flow value. Do not adjust the flow value unless a calibration check is made on the analyzer. 17. Do not leave power on for extended periods of time without flow through the unit. MAINTENANCE INSTRUCTIONS 1. Once system is operational, no routine maintenance is required. 2. Monitoring of flow and temperature values is recommended at least annually. 11

Analytically Accurate TECHNOLOGY About Mustang Sampling Mustang Sampling, LLC is the innovator of Analytically Accurate solutions within sample conditioning systems. We provide custom solutions of products and services globally to the Natural Gas, Natural Gas Liquids (NGL), and Liquefied Natural Gas (LNG) industries. Mustang Sampling continues to pioneer integrated control systems, allowing our customers to maintain phase stability from sample extraction at the source through sample analysis. Our products are continuously improved and subjected to the highest quality standards which provides our customers with the best sample conditioning solutions. Mustang Sampling, LLC 43 Ritmore Glen Ravenswood, WV 26164 P: +1 304 273 5357 F: +1 304 273 2531 info@mustangsampling.com www.mustangsampling.com Copyright 2017 Mustang Sampling. All rights reserved. Mustang Sampling, Mustang, Mustang Intelligent Vaporizer Sampling System and Analytically Accurate are registered trademarks of Mustang Sampling, LLC Kalrez is a registered trademark of DuPont. Viton is a registered trademark of Chemours. Watlow and EZ-ZONE are registered trademarks of Watlow. No part of this publication may be reproduced in any material form without the written permission of Mustang Sampling, LLC. MS-IOMMV.v4-EN-P November 2017 Supersedes: MS-IOMMV.v3-EN-P