FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Similar documents
SERVOMEX PRODUCT GUIDE

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

SERVOMEX PRODUCT GUIDE OUR INDUSTRY-LEADING GAS ANALYZER RANGE AND SYSTEMS, MATCHED TO YOUR INDUSTRY REQUIREMENTS

Dew-Point Transmitters and Instruments

PUV, PIR and PFO Series BROCHURE

Touchpoint Pro Flexible Gas Control System

Sieger Apex. Flexibility that meets your requirements

Enraf Servo Gauge 854 XTG

OMA-300 Process Analyzer

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Electronic Pressure Digest. Pressure and Temperature Transmitters

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Moisture and Hydrocarbon Dew-Point Measurement

SEC Signature Process Gas Analyzer

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Moisture and Hydrocarbon Dew Point Measurement

Searchpoint Optima Plus

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Model Q45P/R. ph/orp Monitor...

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Model 144H. Product Data Sheet , Rev DB February Content

APPLICATION DATA SHEET

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Enraf Servo Gauge 854 ATG

Condumax II Hydrocarbon Dew-Point Analyzer

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Zareba System Overview

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

APPLICATION DATA SHEET

Dependable Solutions for Gas Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger PIR 3000 Detection of flammable gases and vapours

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Dräger Polytron 8100 EC Detection of toxic gases and vapors

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Inductive Conductivity

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Dräger Polytron 8720 IR Detection of carbon dioxide

The Platinum Bullet - ORP. 546 In-Line Submersible. 547 Ball Valve Insertion Assembly. The Pressure Monster. Electrode & Tip Protection Options

Recalibrate the way you look at gas detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

APPLIED. OMA-406R Rackmount Process Analyzer

Zareba Sensepoint Pro

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Zircomat Oxygen Analyzers

Dräger Polytron 5720 IR Detection of carbon dioxide

Series 9000 Total Hydrocarbon Analyzer

Model Q45P/R. ph/orp Monitor...

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

HFID Heated Total Hydrocarbon Analyzer Module

Standard SPECIFICATIONS FEATURES APPLICATIONS

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

A New Standard of Excellence

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Model gffoz Process Ozone Sensor (In-Line)

Ronan Model X96S Series Weighing System

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Safe Operation Manual. Honeywell IQ Force Gas Detector

Danfoss gas detection unit Type GD Heavy Duty

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Dust Alert 75. *shown with optional external keypad and display

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Dräger Polytron 5700 IR Detection of flammable gases and vapours

MagMaster MFE flowmeters feature an innovative multifrequency

Operating Instructions and Maintenance Manual

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

Dräger Polytron 5720 IR Toxic Gas Detection

910 Series Single-point heat-tracing control system

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Dräger PIR 7200 Toxic Gas Detection Transmitter

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger X-am 7000 Multi-Gas Detection

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Gas Detection. Touchpoint Plus. A whole new control experience

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Transcription:

SERVOTOUGH FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS Flexible Can be used in hazard rated locations including Zone 1 and Division 1 Samples any flammable gas up to 100% O 2 with a pressure of up to 40psi High temperature variant allows the handling of high dew point samples Digital communication options: Ethernet and RS485 Modbus SERVOTOUGH The OxyExact safe area oxygen analyzer combines high precision Paramagnetic O 2 sensing technology into a flexible and robust safety-enhanced design, optimized to meet the needs of demanding process monitoring applications like feedstock purity testing and clean up, hydrogen and chlorine production, solvent recovery and sewage and sludge driers. Using an intelligent three enclosure system that facilitates simplified and versatile sampling of any flammable gas up to 100% O 2 (oxygen enriched) - with no need for pre-sample drying - the OxyExact dramatically reduces ongoing costs. Up to six analyzers can be linked to a single control unit (hazardous area or safe area model variants), ensuring that the OxyExact delivers the leading edge performance and adaptability required by the most dangerous process control environments. EASY TO USE Six transmitters can be linked to a single control unit, allowing easy device interaction and set-up Control unit enclosure allows integration of multiple option cards (4 configurable) Low cost of ownership No need for reference/purge gases during measurement in flammable samples Simplified transmitter interaction via intuitive control unit (hazardous area or safe area model variants) Unrivalled performance Uses industry-leading patented Paramagnetic technology for high performance and accuracy Benchmark compliance Internal pressure compensation option to monitor vent pressure variations coupled with high sample pressure option for flare stack applications Internal flow alarm option Rugged, resilient design helps ensure long operational life in harsh conditions Auto-validation and calibration Intelligent enclosure design for exceptional sampling capability ATEX, IECEx, CSA and FM for Zone 1 and Division 1 monitoring Learn more about the SERVOTOUGH VISIT SERVOMEX.COM

PRODUCT OVERVIEW: Unrivalled performance for the most demanding O 2 process monitoring When you work in hazardous area process monitoring applications, a highly accurate, safe O 2 analytical solution that samples any flammable gas mixture up to 100% O 2 is crucial. No matter what your monitoring requirement, you need an analytical solution that offers operational flexibility, exceptional safety and the opportunity to reduce costs. We don t believe you should have to compromise. ALTERNATIVE PRODUCTS The SERVOTOUGH and DF range offer alternative options for oxygen analysis, including: Oxy 1900 A no compromise solution The OxyExact s sophisticated, flexible design ethos ensures it can be precisely configured to a wide range of application environments. A single intuitive use controller can be situated in either a safe area or hazardous area, linking to up to six transmitters, permitting simplified set-up and ongoing maintenance through auto-validation and calibration procedures (direct interaction can be faciliated by optional software). The OxyExact also features an intelligent three enclosure system that allows the flexibility to measure any flammable gas for 0-100% O 2, helping to reduce costs by removing the need for purge gases. When you need high performance O 2 monitoring of flammable gases for applications like blanket inerting and flare stack analysis, choose the award winning Oxy; now augmented by innovative options including Flowcube flow measurement technology. DF-300 Flexible performance you can depend on The OxyExact uses patented Paramagnetic sensing technologies to deliver highly stable and accurate O 2 measurements. Safety-enhanced design and optional flow alarm and pressure compensation ensures sampling versatility - including flare stack applications - that is demanded by your application needs. In addition, Ethernet or RS485 Modbus protocols deliver enhanced communications capabilities. All these aspects combine to make the OxyExact an industry leading solution for O 2 analysis. When trace and ultra-trace O 2 analysis is needed, the DF-300 series provides a feature-rich solution in an intelligent digital format. This device s coulometric E-sensor provides no drift or false low readings, helping to extend calibration periods. KEY APPLICATIONS Oxidation control reactions EO, PTA and EDC Catalyst regeneration Solvent recovery Sewage and sludge driers Claus and related processes Hydrogen and chlorine production TECHNOLOGIES

PRODUCT DATA: OPTIONS DESCRIPTION SPECIFICATION Analog output 1 x standard in transmitter Multiple optional in control unit (2 x per option card) 1 x intrinsically safe 0/4-20mA output per transmitter (standard) 2 x isolated 0/4-20mA outputs per control unit (optional) Output range Analog output parameters User selectable over the measurement range (min. range 0-1% O 2 ) Alarms 3 x standard transmitter status alarms (volt free single pole contacts) 2 x standard control unit status alarms (volt free single pole contacts) 3 x intrinsically safe per transmitter (standard) 2 x 30V ac/dc, 1A per control unit (standard) Flow alarm Added sampling performance (transmitter only) Thick film technology flow sensor Sample compartments 2 x transmitter variants Allows the sampling of any flammable gas up to 100% O 2 High temperature sampling Reduces your sampling costs by removing the need to condense a hot sample prior to analysis 60 o C (2223 transmitter) and 110 o C (2222 transmitter) operation Digital communications Remote monitoring capabilities Modbus Ethernet or RS485 Control unit Up to six transmitters can be linked to a single control unit Safe area/zone 2 or Zone 1 hazardous area variants Power supply Options for use 100-120 or 220-240V ac, 50/60Hz, 50VA Transmitter software Direct interrogation (removing need for controller interaction) Permits direct device configuration from a HMI or PC ACCESSORIES ACCESSORIES AVAILABLE FOR SPECIFIC APPLICATIONS CONTACT YOUR LOCAL SERVOMEX BUSINESS CENTER MEASUREMENT PERFORMANCE Transmitter variant 2222 transmitter (110 o C) 2223 transmitter (60 o C) Gas O 2 O 2 Technology Paramagnetic Paramagnetic Range 0-100% 0-100% Accuracy (intrinsic error) <±0.02% O 2 <±0.02% O 2 Repeatability 0.02% 0.02% Zero drift/week <0.08% <0.02% T 90 response time <4s <4s Operating Temp. 110 C/230 F 60 C/140 F

PRODUCT DATA: SAMPLE FOR MEASUREMENTS Sample gas Flow Control Sample inlet connection Sample wetted material Inlet pressure Sample pressure The sample gas must be clean, non-corrosive and free from oil and condensates Standard: 50 250ml/min (200ml/min recommended) Optional high flow internal bypass: 50-70l/h (60l/h recommended) ¼ NPT female, 6mm tube or ¼ tube Standard: 316SS, borosilicate glass, hastelloy, platinum, platinum/iridium alloy, electroless nickel, Viton Solvent resistant: 316SS, borosilicate glass, hastelloy, platinum, platinum/iridium alloy, electroless nickel, Chemraz 555, PTFE 0.3kPag (0.04psig) relative to sample vent pressure (all variants) Standard: 28kPag (4psig) max. High Pressure (< 21% O 2 ): 205kPag (30psig) max DEVICE SPECIFICATION DEVICE SCHEMATIC Size: 2210 control unit: 280 (W) x 290 (H) x 236mm (D) 2213 control unit: 490 (W) x 315 (H) x 236mm (D) 2222/2223 transmitter: 432 (W) x 303 (H) x 210mm (D) Weight: 2210 control unit: 10kg (22lbs) 2213 control unit: 25kg (55.1lbs) 2222/2223 transmitter: 16kg (35.3lbs) Sample Pressure: Standard: 28kPag (4psig) max High Pressure (<21% O 2 ): 205kPag (30psig) max 490 Ø290 250 236.12 222.12 Certifications: 2210 control unit: ATEX Cat. 3 IECEx Zone 2 FM/CSA Class 1 Div. 2 230 275 315 PBOxyExact Rev.0 Date: 08/14 2213 control unit: ATEX Cat. 2 IECEx Zone 1 FM/CSA Class 1 Div. 1 2222/2223 transmitter: ATEX Cat. 2 IECEx Zone 1 FM/CSA Class 1 Div. 1 All variants comply with BS EN 61010 These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices Directive 93/42EEC. Please note: This document was updated in August 2014. While every effort has been made to ensure accuracy, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. AMERICAS BUSINESS CENTER Tel: +1 281 295 5800 Email: americas_sales@servomex.com ASIA PACIFIC BUSINESS CENTRE Tel: +86 (0)21 6489 7570 Email: asia_sales@servomex.com EUROPEAN BUSINESS CENTRE Tel: +31 (0) 79 330 1580 Email: europe_sales@servomex.com LATIN AMERICA BUSINESS CENTER Tel: +55 11 5188 8166 Email: brazil_sales@servomex.com INDIA BUSINESS CENTRE Tel: +91 22 3934 2700 Email: MEI_sales@servomex.com MIDDLE EAST BUSINESS CENTRE Tel: +971 6552 8073 Email: MEI_sales@servomex.com Servomex has a policy of constant product improvement and reserves the right to change specifications without notice. Servomex Group Limited. 2014. A Spectris company. All rights reserved.