Model Number Structure

Similar documents
Model Number Structure. Floatless Level Switch (Basic Type)

Model Number Structure

Scale 0: 10 k Scale 50: 10 k (see note 2)

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Ultrasonic Reflective Sensor

onlinecomponents.com

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Ultrasonic Proximity Sensor

Ultrasonic Reflective Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Original instructions JSNY7 Magnetic switch

Original instructions Sense7-series Non-contact coded safety switch

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Digital Temperature Controller

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2

Annuciator Logic Controllers

AUR300C. Advanced Ultraviolet Burner Controller

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

R1000 / R1040 / R1080

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Booster Power Supply Manual

SAVE THESE INSTRUCTIONS

WATLOW IND. Thermostat Control Installation & Maintenance Manual I&M NUMBER

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

MR3CCUHV Temperature/Defrost Control

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

SAFETY INFORMATION AND WARNINGS

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

XT Series Thermostats

ISIS SAFETY SYSTEM Installation guide

EUROBOX SERIES TYPES CM...N SM...N MM...N

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

430128A. B-Series Flow Meter SIL Safety Manual

Liquid Level Controller

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

E PIR Motion Detector. Features. General Description. Applications. Single Sensor Application Circuit

03.03.mmm REV.2 09/01

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

SCHMIDT LED Measured Value Display MD Instructions for Use

ARGO ZONE VALVE CONTROLS AZ-4CP / AZ-6CP

Electric Duct Heaters

DSD-080 SEISMIC SECURITY PANEL DESCRIPTION FEATURES. DSD-080 User Manual

E5CN E5CN-U E5AN E5EN

CII FCAC-150 Series Relay

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Micropower Omnipolar Digital Hall-Effect Sensor ICs

Installation & Operation Manual

INSTALLATION INSTRUCTIONS

Conductive Leakage detectors of the Leckstar range

ELECTRONIC HUMIDISTAT: H270

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

PANTHER. Condensate removal pump Installation and operating guide

EC3-X33 Stand-alone Superheat Controller Technical Data

STATUS ALARM HISTORY ALARM RESET

E3M-V. Mark Sensor. Applications

DTA04. Motor thermistor relay. Benefits. Description

TEMPERATURE CONTROLLER

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

1.7. Insulation fault evaluators EDS460/490 EDS461/491

02/11/2015

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

SKORPION Process Air Heater

Temperature Controllers

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Model 5190-E Temperature/Humidity Probe

District Heating Controller

Model 5190-F Temperature/Humidity Probe

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

M3050 Detector Operator s Manual

INSTRUCTION MANUAL P Heating and 1 Cooling

PM100 Room pressure monitor

SEC 2000 Millenium Infrared Gas Detector

RE-PR3-E-27 3-Phase Panel Mount 27kW

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Transcription:

Floatless Level Switch (asic Type) 61F-G@ CS_61F-G DS_E_4_1 asic uilding-block Controllers That ount Directly to anels for Easier aintenance Easy maintenance with building-block Relay nits. Easy identification of operating status with LED operation indicator. Lineup includes models for tropical regions and for high temperatures. Achieve stable detection even in hightemperature environments. Refer to Safety recautions for Floatless Level Controllers. odel Number Structure 61F-@@ 1 2 1. Control Application G: Automatic water and drainage G1: Automatic water with idling prevention or water shortage alarm G2: Automatic water and drainage with abnormal water increase alarm G3: Automatic water and drainage with full and water shortage alarm G4: Automatic water with water level indicator for water and water receiving and prevention of idling due to water shortage I: Liquid level indication and alarm (no two-wire models) 2. Type lank: General-purpose L 2K: Long-distance (for 2 km) L 4K: Long-distance (for 4 km) H: High-sensitivity D: Low-sensitivity R: Two-wire T: High-temperature osition of LED indicator Ordering Information Type General-purpose Long-distance, 2 km Long-distance, 4 km High-sensitivity odel odel odel odel Application G 61F-G 61F-GL 2K 61F-GL 4K 61F-GH Application G1 61F-G1 61F-G1L 2K 61F-G1L 4K 61F-G1H Application G2 61F-G2 61F-G2L 2K 61F-G2L 4K 61F-G2H Application G3 61F-G3 61F-G3L 2K 61F-G3L 4K 61F-G3H Application G4 61F-G4 61F-G4L 2K 61F-G4L 4K 61F-G4H Application I 61F-I 61F-IL 2K 61F-IL 4K 61F-IH Relay nit L 2K L 4K H Type Low-sensitivity 2-wire Tropical environments High-temperature odel odel odel odel Application G 61F-GD 61F-GR 61F-G-TDL 61F-GT Application G1 61F-G1D 61F-G1R 61F-G1-TDL 61F-G1T Application G2 61F-G2D 61F-G2R 61F-G2-TDL 61F-G2T Application G3 61F-G3D 61F-G3R 61F-G3-TDL 61F-G3T Application G4 61F-G4D 61F-G4R 61F-G4-TDL 61F-G4T Application I 61F-ID --- 61F-I-TDL 61F-IT Relay nit D R --- T Note: When ordering, specify the desired operating voltage at the end of the model number. Eample: 61F-G [110/22AC] Desired voltage 1

Specifications 61F-G@ Standard odels Specifications Items Controlling materials and operating conditions General-purpose Controller 61F-@ (TDL) (see note 1 and 2) For control of ordinary purified water or sewage water Hightemperature Controller 61F-@T (see note 1) For control of ordinary purified water or sewage water in cases where the ambient temperature is high. Long-distance Controllers 61F-@L 2K (for 2 km) 61F-@L 4K (for 4 km) (see note 1) For control of ordinary purified water in cases where the distance between sewage pumps and water s or between receiver s and s is long or where remote control is required. High-sensitivity Controllers 61F-@H (see note 1) For control of liquids with high specific resistance such as distilled water Low-sensitivity Controller 61F-@D (see note 1) For control of liquids with low specific resistance such as salt water, sewage water, acid chemicals, alkali chemicals Two-wire Controller 61F-@R (see note 1) For control of ordinary purified water or sewage water used in combination with Two-wire Electrode Holder (incorporating a resistor of 6.8 kω) It is possible to wire with less than one wiring against general 61F s wiring. Supply voltage 100, 110, 120, 200, 220 or 24AC; 50/60 Hz Operating voltage range 85% to 110% of rated voltage InterElectrode voltage AC AC AC InterElectrode current Appro. 1 ma AC ma. ower consumption 61F-G@: 3.5 VA ma.; G1F-G1@, G1F-G2@, or G1F-I@: 5.5 VA ma.; G1F-G3@: 7.5 VA ma.; G1F-G4@: 14.5 VA ma. InterElectrode operate resistance 0 to appro. 1.8 kω 0 to appro. 1.1 kω InterElectrode release resistance Cable length (see note 3) 0 to appro. 4 kω 0 to appro. 5 kω 0 to appro. 1.8 kω (for 2 km) 0 to appro. 0.7 kω (for 4 km) Appro. 15 k to Ω Appro. 15 k to Ω 4 k to Ω (for 2km) 2.5 k to Ω (for 4km) 1 km ma. 600 m ma. 2 km ma. 4 km ma. Appro. 15 kω to 70 kω (see note 5) Appro. 300 k to Ω Appro. 5 k to Ω Appro. 15 k to Ω 50 m ma. 1 km ma. 800 m ma. Control output 2 A, 22AC (Inductive load: cosφ = 0.4) 5 A, 22AC (Resistive load) Ambient temperature Operating: 10 to 55 C ( 10 to 70 C for 61F-@T) Ambient humidity Operating: 45% to 85% RH Insulation resistance 100 Ω min. (at 50DC) (see note 4) Dielectric strength 200AC, 50/60 Hz for 1 min. (see note 4) Life epectancy Electrical: 500,000 operations min. echanical: 5,000,000 operations min. Weight 61F-G@: Appro. 380 g, G1F-G1@, G1F-G2@, or G1F-I@: Appro. 750 g; G1F-G3@: Appro. 930 g; G1F-G4@: Appro. 1,710 g Note: 1. The @ in the model name represents G, G1, G2, G3, G4, and I. 2. The suffi TDL attached to the model name represents models designed for tropical regions (storage humidity of 45% to 90%). For details, refer to Safety recautions for Floatless Level Controllers. 3. The length when using completely-insulated, 600-V, 3-conductor (0.75 mm 2 ) cabtire cables. sable cable lengths will become shorter as the cable diameter or number of conductors becomes larger. For details, refer to Safety recautions for Floatless Level Controllers. 4. The insulation resistance and dielectric strength indicate values between power terminals and Electrode terminals, between power terminals and contact terminals, and between Electrode terminals and contact terminals. 5. ossible to use with 15 kω or less, however, this may cause reset failure. 6. High-sensitivity Controllers use advanced operation. When the power voltage is applied, if there are some liquids between the electrodes (ground and operation electrodes), the internal will not operate. When the power voltage is applied, if there are no liquids between the electrodes (ground and operation electrodes), the internal will operate. Advanced Operation With advanced operation, the internal operates as soon as control power is supplied to the G1F and is reset when current flows between the poles. Wiring is the same as for models with sequential operation. 2

Internal Circuit Diagrams 61F-G@ The schematic diagrams shown below typify the internal connections of the various 61F models. The designations Ta, Tb, and Tc (sometimes referred to collectively as ) may occur more than once in a product, however, the a terminal is always an NO contact, a b terminal is an NC contact, and the c terminal is the common terminal. 61F-G 61F-GT 61F-GL 100, 110 or 12 200, 220 or 24 Relay nit 100, 110 or 12 200, 220 or 24 T Relay nit 100, 110 or 12 200, 220 or 24 L Relay nit Ta Tc Tb Ta Tc Tb Ta Tc Tb S0 S1 S2 S0 S1 S2 S0 S1 S2 61F-GH (See note.) 100, 110 or 12 200, 220 or 24 H Relay nit 61F-GD 100, 110 or 12 200, 220 or 24 D Relay nit 61F-GR 100, 110 or 12 200, 220 or 24 R Relay nit Ta Tc Tb Ta Tc Tb Ta Tc Tb S0 S1 S2 S0 S1 S2 S0 S1 S2 3

61F-G@ Note: The 61F11H deenergizes when there is water present across the Electrodes, whereas the 61F energizes when there is water present across the Electrodes. Also, the terminal connections of those Controllers provided with LED indicators differ from those which have no indicators. Relay nits Item T L H D R Interchangeable with general-purpose model () --- rovided rovided Not provided rovided Not provided Color of band on name plate --- Red Yellow lue lack Green T L E S S S E S S S 8 7 6 5 4 8 7 6 5 4 E S S S 8 7 6 5 4 Tr1 Tr2 Tr1 Tr2 Tr1 Tr2 9 10 11 1 2 3 9 10 11 1 2 3 9 10 11 1 2 3 Tb2 Ta2 Tc2 Tc1 Ta1 Tb1 Tb2 Ta 2 Tc2 Tc1 Ta 1 Tb1 Tb2 Ta2 Tc2 Tc1 Ta 1 Tb1 H (see note) E S S S 8 7 6 5 4 Tr 2 D E S S S 8 7 6 5 4 R E S S S 8 7 6 5 4 Tr1 Tr2 Tr1 Tr2 Tr1 Tr2 9 10 11 1 2 3 9 10 11 1 2 3 9 10 11 1 2 3 Ta 2 Tb2 Tc2 Tc1 Tb1 Ta1 Tb2 Ta 2 Tc2 Tc1 Ta 1 Tb1 Tb2 Ta2 Tc2 Tc1 Ta 1 Tb1 4

Automatic Supply and Drainage Control asic Type 61F-G 61F-G@ Dimensions: page 13 Automatic Supply Control Automatic Drainage Control 220-VAC power CC 61F-G 0V 11 22 Relay nit 220-VAC ower CC 61F-G 11 22 Relay nit Ta Tc Tb S0 S1 S2 Ta Tc Tb S0 S1 S2 (See note.) otor S-3S otor (See note.) S-3S Waste water Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb to the contactor s coil terminal. ower Supply (for models with 110/220-V power) 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Connect Ta to the contactor s coil terminal. (Do not connect Tb.) ower Supply (for models with 110/220-V power) 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. rinciples of Operation Relay nit Location rinciples of Operation Relay nit Location ower 1 ower 1 ump OFF ( indicator ON) ump ON ( indicator ON) ump ON ( indicator OFF) ump OFF ( indicator OFF) drainage The pump stops (indicator ON) when the water level reaches and starts (indicator OFF) when the water level drops below. The pump starts (indicator ON) when the water level reaches and stops (indicator OFF) when the water level drops below. 5

61F-G@ Automatic Supply Control with ump Idling revention and Automatic Supply Control with Abnormal Shortage Alarm asic Type 61F-G1 Dimensions: page 13 Automatic Supply Control with ump Idling revention 22AC power 61F-G1 CC 11 22 2 Relay nit Relay nit 2 1 2 1 1 Automatic Supply Control with Abnormal Shortage Alarm 22AC power 61F-G1 CC 11 22 2 Relay nit Relay nit 2 1 2 1 1 otor So Tb1 Ta1 Tc2 Tb2 S1 S2 ' ' (See note.) S-3S ' ' ' S-3S Alarm () ush button switch otor So Tb1 Ta1 Tc2 Tb2 S1 S2 ' ' (See note.) S-4S Alarm () ush button switch shortage Note: e sure to ground the common Electrode (the longest Electrode). ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Insert a pushbutton switch (NO) between ' and, as shown by the dotted lines above. Do not press the pushbutton if the low-water alarm sounds and the pump stops during normal operation (1 indicator ON, water below '). Test Operation/Recovering from ower Interruptions If the water level is below ' when starting operation or when recovering from a power interruption, press the pushbutton to momentarily close the circuit (1 indicator turns ON) to start the pump. Note: e sure to ground the common Electrode (the longest Electrode). ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Insert a pushbutton switch (NO) between and. If the pump stops when the pushbutton switch is released, press it again. Test Operation/Recovering from ower Interruptions If the water level is below when starting operation or when recovering from a power interruption, press the pushbutton to momentarily close the circuit (1 indicator turns ON) to start the pump. rinciples of Operation Relay nit Location ower 1 2 rinciples of Operation Relay nit Location ower 1 2 ump OFF shortage ' ' L (1 indicator ON) (1 indicator OFF) (2 indicator ON) ump OFF ump ON L shortage (2 indicator ON) (2 indicator OFF) (1 indicator OFF) ump ON (2 indicator OFF) The pump starts (2 indicator OFF) when the water level drops below and stops (2 indicator ON) when the water level reaches. When the level of the water drops below ', the pump stops (1 indicator OFF). ump idling is prevented and the alarm sounds. The pump stops (2 indicator ON) when the water level reaches and starts (2 indicator OFF) when the water level drops below. If the water level drops below for any reason, the pump stops (1 indicator OFF) and the alarm sounds. 6

61F-G@ Automatic Drainage Control and Supply with Abnormal Increase Alarm asic Type 61F-G2 Dimensions: page 13 Automatic Supply with Overfull Tank Alarm Automatic Drainage Control with Overfull Tank Alarm 22AC power 61F-G2 Relay nit 1 22AC power 61F-G2 Relay nit 1 CC 11 Relay nit 2 CC 11 Relay nit 2 22 22 2 2 2 1 2 1 So Ta1 Tc1 Tb1 Ta2 Tc2 So Ta1 Tc1 Tb1 Ta2 Tc2 S1 S2 S1 S2 (See note.) Alarm S-4S (See note.) Alarm otor Full otor Waste water S-4S Full Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb1 to the power. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Connect Ta1 to the power. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. rinciples of Operation ump OFF pper L (1 indicator ON) (2 indicator ON) Relay nit Location ower 1 2 rinciples of Operation L ump ON pper (1 indicator ON) (2 indicator ON) Relay nit Location ower 1 2 ump ON (2 indicator OFF) ump OFF (2 indicator OFF) drainage The pump starts (2 indicator OFF) when the water level drops below and starts (2 indicator ON) when the water level reaches. If the water level reaches for any reason, the alarm sounds (1 indicator ON). The pump starts (2 indicator OFF) when the water level reaches and stops (2 indicator ON) when the water level drops below. If the water level reaches for any reason, the alarm sounds (1 indicator ON). 7

61F-G@ Automatic Supply and Drainage Control with Abnormal Increase and Shortage Alarms asic Type 61F-G3 Dimensions: page 13 Automatic Supply with Abnormal Increase and Shortage Alarms 22AC power 61F-G3 CC 11 22 Relay nit Relay nit Relay nit 1 2 3 Automatic Drainage Control with Abnormal Increase and Shortage Alarms 22AC power 61F-G3 CC 11 22 Relay nit Relay nit Relay nit 1 2 3 1 3 1 3 2 1 3 1 3 2 2 2 Ta Tc Tb 1 2 Lc E5 S0 S1 S2 LH LL Ta Tc Tb 1 2 Lc E5 S0 S1 S2 LH LL Alarm pper L Lower L (See note.) Alarm pper L Lower L (See note.) otor S-5S E5 Full shortage otor Waste water E5 S-5S Full shortage Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb to the contactor s coil terminal. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Connect Ta to the contactor s coil terminal. (Do not connect Tb.) ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. rinciples of Operation ump OFF ump ON E5 pper LH (1 indicator ON) (2 indicator ON) Lower (2 indicator OFF) (3 indicator OFF) LL Relay nit Locations ower 1 2 3 rinciples of Operation ump ON ump OFF E5 LH pper (1 indicator ON) (2 indicator ON) Lower (2 indicator OFF) (3 indicator OFF) LL Relay nit Locations ower 1 2 3 The pump stops (2 indicator ON) when the water level reaches and starts (2 indicator OFF) when the water level drops below. If the water level rises to for any reason, the upper- indicator turns ON and the alarm sounds (1 indicator ON). If the water level drops below for any reason, the lower- indicator turns ON and the alarm sounds (3 indicator OFF). The pump starts (2 indicator ON) when the water level reaches and stops (2 indicator OFF) when the water level drops below. If the water level rises to for any reason, the upper- indicator turns ON and the alarm sounds (1 indicator ON). If the water level drops below for any reason, the lower- indicator turns ON and the alarm sounds (3 indicator OFF). 8

61F-G@ Automatic Supply Control with Source Level Indication, revention of ump Idling Due to Shortage, and Indication of Level in Tank asic Type 61F-G4 Dimensions: page 13 Automatic Supply Control with Source Level Indication, revention of ump Idling Due to Shortage, and Indication of Level in Tank ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. Insert a pushbutton switch (NO) between and E8, as shown by the dotted lines above. Do not press the pushbutton if the low-water alarm sounds and the pump stops during normal operation (water below ). Test Operation/Recovering from ower Interruptions CC 22 power 61F-G4 1 K3 Relay (See note 2.) 4 2 11 22 11 22 8V 3 1 5 Relay nit Relay nit Relay nit Relay nit Relay nit 4 5 1 2 3 4 3 2 5 If the water level is below when starting operation or when recovering from a power interruption (2 indicator OFF), press the pushbutton to momentarily close the circuit to start the pump. LL1 LL2 LH1 LH2 L1 L2 H1 H2 S0 S1 S2 TC TC2 TA E8 E7 E6 E5 Elevated water shortage lower Elevated repletion upper Elevated water shortage lower Elevated repletion LL1 LL2 LH1 LH2 L1 L2 H1 H2 upper ushbutton switch (See note 1.) S-5S otor E8 S-4S pper Lower E7 E8 E6 E5 Full shortage Note: e sure to ground the common Electrode (the longest Electrode). rinciples of Operation Insert four Electrodes in the water and five Electrodes in the elevated water. The lower- indicator for the water remains ON while the water level is below (2 indicator OFF). When the water level rises to, the lower- indicator turns OFF (2 indicator ON) and the pump is ready for operation. The upper- indicator in the water lights when the water level reaches (3 indicator ON). The water-shortage indicator for the elevated remains ON while the water level in the elevated is below E7. The indicator turns OFF (1 indicator ON) when the water level rises to E7. The pump stops (5 indicator ON) when the water level reaches E5 and starts (5 indicator OFF) when the water level drops below E6. If the water level reaches for any reason, the abnormal water increase indicator for the elevated turns ON (4 indicator ON). Relay nit Location 1 2 3 4 5 ower 9

Connection with Three-phase Four-line Circuit When ing power from N-phase to the Controller in three-phase four-line circuit, refer to the following diagrams. Line voltage (R-S, S-T, or R-T): 380 or 415 VAC hase voltage (N-R, N-S, or N-T): 220 or 24AC 61F-G@, 220 or 24AC 61F-G@ Supply ower 380 or 415 VAC N * Transformer Relay nit Ta Tc Tb S0 S1 S2 S3 A Rated voltage: S0-S2: 220 or 24AC * Electromagnetic switch Note: e sure to ground terminal. 10

61F-G@ Liquid Level Indication and Alarm asic Type 61F-I Dimensions: page 13 Liquid Level Indication and Alarm ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. 220-VAC power 61F-I Relay nit 1 CC 11 Relay nit 2 22 2 1 1 2 TC L3 L2 L1 S0 S1 S2 Alarm Intermediate pper Lower L L L (See note.) S-3S pper alarm Intermediate Lower alarm Note: e sure to ground the common Electrode (the longest Electrode). rinciples of Operation When the water level drops below, the lower- indicator turns ON and the alarm sounds (2 indicator OFF). When the water level reaches, the alarm turns OFF and the intermediate indicator turns ON (2 indicator ON). When the water level rises to, the upper- indicator turns ON and the alarm sounds (1 indicator ON). LH L LL pper iddle Lower (1 indicator ON) (1 indicator OFF) (2 indicator ON) (2 indicator OFF) Relay nit Location ower 1 2 11

Two-Wire Automatic Supply and Drainage Control asic Type 61F-GR 61F-G@ Automatic Supply Control Automatic Drainage Control 220-VAC power CC 61F-GR 11 R Relay nit 220-VAC power CC 61F-GR 11 R Relay nit 22 22 Ta Tc Tb Ta Tc Tb S0 S1 S2 S0 S1 S2 otor protective S-3SR R (See note.) otor protective (See note.) Waste water R S-3SR Reservoir Note: e sure to ground the common Electrode (the longest Electrode). Note: e sure to ground the common Electrode (the longest Electrode). Connect Tb to the contactor s coil terminal. ower Supply 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. With 2-wire connections, only two wires are required between the 61F-GR and Electrode Holder, but three wires are required for the Electrodes. The Electrode Holder must be specified for 2-wire connections. (Resistance R is built into Electrode Holders for 2-Wire.) The Relay nit must also be specified for 2-wire connections. Connect Ta to the contactor s coil terminal. (Do not connect Tb.) ower Supply (for models with 110/220-V power) 11AC: Connect S0 and S1. 22AC: Connect S0 and S2. With 2-wire connections, only two wires are required between the 61F-GR and Electrode Holder, but three wires are required for the Electrodes. The Electrode Holder must be specified for 2-wire connections. (Resistance R is built into Electrode Holders for 2-Wire.) The Relay nit must also be specified for 2-wire connections. rinciples of Operation rinciples of Operation ump OFF ( indicator ON) ump ON ( indicator ON) ump ON ( indicator OFF) ump OFF ( indicator OFF) drainage The pump stops ( indicator ON) when the water level reaches and starts ( indicator OFF) when the water level drops below. The pump starts ( indicator ON) when the water level reaches and stops ( indicator OFF) when the water level drops below. 12

Dimensions 61F-G@ Note: All units are in millimeters unless otherwise indicated. Standard odels 61F-G 3 screw ounting Holes Four, 6-dia mounting holes 61F-G1 61F-G2 61F-I Four, 6-dia holes 3 screw ounting Holes Four, 6-dia mounting holes 61F-G3 Four, 6-dia holes 3 screw ounting Holes Four, 6-dia mounting holes Four, 6-dia holes 61F-G4 3 screw ounting Holes Four, 6-dia mounting holes Four, 6-dia holes ALL DIENSIONS SHOWN ARE IN ILLIETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 13

Read and nderstand This Catalog lease read and understand this catalog before purchasing the products. lease consult your ORON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY ORON's eclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by ORON. ORON AKES NO WARRANTY OR RERESENTATION, ERESS OR ILIED, REGARDING NON-INFRINGEENT, ERCHANTAILITY, OR FITNESS FOR ARTICLAR ROSE OF THE RODCTS. ANY YER OR SER ACKNOWLEDGES THAT THE YER OR SER ALONE HAS DETERINED THAT THE RODCTS WILL SITALY EET THE REQIREENTS OF THEIR INTENDED SE. ORON DISCLAIS ALL OTHER WARRANTIES, ERESS OR ILIED. LIITATIONS OF LIAILITY ORON SHALL NOT E RESONSILE FOR SECIAL, INDIRECT, OR CONSEQENTIAL DAAGES, LOSS OF ROFITS OR COERCIAL LOSS IN ANY WAY CONNECTED WITH THE RODCTS, WHETHER SCH CLAI IS ASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIAILITY. In no event shall the responsibility of ORON for any act eceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL ORON E RESONSILE FOR WARRANTY, REAIR, OR OTHER CLAIS REGARDING THE RODCTS NLESS ORON'S ANALYSIS CONFIRS THAT THE RODCTS WERE ROERLY HANDLED, STORED, INSTALLED, AND AINTAINED AND NOT SJECT TO CONTAINATION, ASE, ISSE, OR INARORIATE ODIFICATION OR REAIR. Application Considerations SITAILITY FOR SE ORON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, ORON will provide applicable third party certification documents identifying ratings and ations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some eamples of applications for which particular attention must be given. This is not intended to be an ehaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. lease know and observe all prohibitions of use applicable to the products. NEVER SE THE RODCTS FOR AN ALICATION INVOLVING SERIOS RISK TO LIFE OR ROERTY WITHOT ENSRING THAT THE SYSTE AS A WHOLE HAS EEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE ORON RODCTS ARE ROERLY RATED AND INSTALLED FOR THE INTENDED SE WITHIN THE OVERALL EQIENT OR SYSTE. ROGRAALE RODCTS ORON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SECIFICATIONS roduct specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fi or establish key specifications for your application on your request. lease consult with your ORON representative at any time to confirm actual specifications of purchased products. DIENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERFORANCE DATA erformance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of ORON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the ORON Warranty and Limitations of Liability. ERRORS AND OISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. ORON Corporation Industrial Automation Company http://www.ia.omron.com/ 2010.4 In the interest of product improvement, specifications are subject to change without notice. (c)copyright ORON Corporation 2010 All Right Reserved.