Instrument Air Packages engineered for the desert and high temperature environements

Similar documents
Cooler Range. For use with AESSEAL Seal Support Systems.

DRY BULK HANDLING SYSTEM

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

Nuclear Electric Heating

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

.2 Section Waste Management and Disposal.

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Addressing Challenges in HIPPS Design and Implementation

Scroll Medical Air Compressor with Premium NFPA Control Panel

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Excellent performance with low operating costs, Energy saving and environmentally friendly

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

Cooling, conditioning, purifying. Cooling, conditioning, purifying.

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

TECHNICAL DATA MOBILE WASTE INCINERATOR

Concept WVM Brief description. Efficient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

GENERAL OVERVIEW ELECTRIC HEATERS - EXCHANGERS - PACKAGES ELECTRIC HEATING SOLUTIONS ELECTRIC HEATERS EXCHANGERS PACKAGES

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

Vulcanic. Engineered Projects

Oil & Gas Case History

CORPORATE PROFILE. Contents 1 Introduction 2 Products and Services 3 Contact Us 10

EQUIPMENT Group 6 PACKAGE PRICE 2.350, Compressor KAESER SM bar. 203 Refrigeration dryer KAESER T135. Compressed air tank KAESER 90 l

HAL Hercules Horizontal Pumping System STRONG. VERSATILE. EFFICIENT.

OILFIELD INSTRUMENTATION & CONTROL SYSTEMS. Rig Control Products Ltd

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

Inert Gas Fire Extinguishing System

SRS Engineering offers the TW-Series (tote washer / tank washer) designed to work with metal or plastic totes or tanks with maximum opening of 80".

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

TEMPERATURE CONTROL POWER COMPRESSED AIR EMERGENCY OR PLANNED, SHUT DOWN OR TURN AROUND. 24/7/ / ers-cat.com

A strong group. For your success.

100% Oil-Free - Guaranteed

Emerson Automation Solutions Products & Services

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Heatless Desiccant Compressed Air Dryers

Washing Systems for Pails, Buckets and Jars

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

HIPPS High Integrity Pressure Protection System

Air & Gas Compression Systems

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

CLEAN, DRY COMPRESSED AIR

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Call us today! (800)

Call us today! (800)

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Engineering Guideline. pac- Carriers Type Universal

Oxygen Plant Installation for Paktia Hospital (Gardez City)

TECHNICAL BID EVALUATION SCOPE OF WORK COMPRESSED AIR SYSTEM

Product Data Sheet Adsorption Dryer DPS (A)

IC-45AV Vertical Clean Centrifuge

GENERAL CAPABILITIES

SOCH AUTOMATION AND POWER SOLUTION

SECTION AIR COMPRESSORS AND ACCESSORIES

Rotary screw compressors

Freeze-Drying Solutions

TECHNICAL SERVICES DIVISION

IBC Wash: Critical Cleaning Solution for IBCs, Totes and Tablet Bins.

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Dual Tower Heat Reactivated Desiccant Air Dryer

TYPE APPROVAL CERTIFICATE

Alternative Fuel Fueling Stations

Holds a B. Sc. in Electronics & Communication Engineering and has over 8 years hands-on experience working in I&C field.

Refrigeration Plant Information. We Speak Hockey 365

Rotary screw compressors

EM4 APPLICATIONS EXAMPLES

Industrial Freezers &

Quality Components as a basis for Quality Equipment

SECTION AIR COMPRESSORS AND ACCESSORIES

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

Rosemount 2100 Series

MELAMINE DRYERS PRESENTATION MELAMINE DRYERS

This series is utilized for waste streams which are not prone to hardening in the presence of liquid solvent, and provides ease of residue removal.

rml Retractable CIP Spray Nozzles Manual Manual Installation, Operating and Commissioning ORIGINAL FILE

Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)

BASIL 6700 TUNNEL CAGE WASHER

Call us today! (800)

SCR ROTARY SCREW AIR COMPRESSORS

Lift Station Monitoring & Control The process begins here

CONTROL SYSTEM D ESIGN, E NGINEERING & C ONSTRUCTION.

Design Benefits and Advantages:

Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)

Instrumentation Products and Applications

Explosion Protection Engineering Principles

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

EG Series Screw Air Compressors Life source of industries kw

DESICCANT AIR DRYERS. BD + CD + CD series

General Pricelist December 2009

Oil Free Scroll Compressors

LEWA Plunger pumps. For high hydraulic power.

LMF Rotary Screw Air Compressors kW LX Range

Transcription:

-5 C +55 C Instrument Air Packages engineered for the desert and high temperature environements Oil free and oil injected compressors and heatless dryers

THE DETAILS MAKE THE DIFFERENCE

DESIGNED FOR THE LOCATION COMPRESSOR AND DRYER LAYOUT

The compressor is designed to run continuously despite the location s harsh conditions, the operation of the product and the maintenance requirements Cooling section with chiller Power and Controls Compressor Air Cooler 37-600 kw STANDARD 3-SECTION LAYOUT OF AN OIL-FREE COMPRESSOR WITH MIXED COOLING. ADAPTED TO MEET THE INSTALLATION REQUIREMENTS AND PROJECT SPECIFICATIONS.

The instrument air packages are also engineered on a single skid for ease of installation and control Compressor 1 ON SITE 50 c! Dryer and filters 1/2 Compressor 2 Power and Controls 37-132 kw STANDARD LAYOUT ASSEMBLED ON A SINGLE SKID WITH COMPRESSORS, DRYERS, FILTERS POWER AND CONTROL. ADAPTED TO MEET THE INSTALLATION REQUIREMENTS AND PROJECT SPECIFICATIONS.

Controls Dryer Filter Dryer designed for use with max. water intake and max. input temperature with spare dryer parts fully available 60-8000 Nm3/h STANDARD DRYER LAYOUT WITH 3 SECTIONS.

COMPONENT STANDARDISATION FOR EASE OF MAINTENANCE AND REDUCTION IN THE NUMBER OF EXPENSIVE WAREHOUSE PARTS

Instruments suitable for use in process systems with the same models for both compressor and dryer

Standard PLC components for compressor and dryer Rockwell micro logic 850 and Contol Logix 500o are used on the packages. SIL2, SIL3 certification are available Standard layout of Rockwell Micro Logic 850 PLC with communication port and expansion cards Standard layout of RockwellControl Logix 5000 redundant PLC,SIL2, with communication port and expansion cards

COMPLIANCE WITH INTERNATIONAL RULES SAFETY FIRST

When required, the compressor motor and fancooling motor are certified for ATEX zone 1 and zone 2 or for Class 1 Div.1

When required, the control panel is certified for Atex Zone 1 and Zone 2 or Class 1 Div. 1 using an explosion-proof or pressurized box

Solenoid valve certified for ATEX Zone 1, Zone 2 or Class 1 Div.1

All pressure vessels comply with ASME VIII div. 1 and U stamped, PED97/23 CE, ARH, SELO, DOSH.

Safety valve sized as per API520 and manufactured as per API526

ENGINEERING DETAIL AIR FILTRATION TECHNOLOGY, COOLING SYSTEM MECHANICS AND MATERIALS

A major issue with desert installation, particularly with the oil-injected screw compressor, is the filtration of the air intake. Blutek has developed its own Reverse Pulse Jet intake filter with a sand collection drum to improve efficiency of filtration and the lifespan of the element Intake pipe from filter to compressor Sand trap for cleaning the cooling air Intake with bird screen and water sealer Intake filter Sand collection drum

The second major issue in the desert is the cooling system; with no water available the compressor must be cooled by air. Blutek developed 2 types of cooling systems designed to cover the whole application. Cooling system 1 The cooling system is completely air-cooled with external SS316L coolers with aluminum fin and an extraction fan.this application is covers the range of working pressure up to a max. of 8 barg with ambient temperature of 55 C 55 C 8 barg Intercooler Aftercooler

Standard P&ID for cooling system 1

55 C 10,5 barg Cooling system 2 The system is partially air-cooled with a combination of external SS316L coolers with aluminum fin, aluminum coolers which refine the temperature and water coolers that turn on when the ambient temperature reaches 30 C. The water-cooled coolers are fed by a close-loop circuit with chiller, water pump and water tank.this application covers a range of working pressure up to a max. of 10,5 barg with ambient temperature of 55 C Air cooled section Water cooled section Chiller and water tank

Standard P&ID for Cooling system 2

The standard manufacturer coupling is Wrapflex model or as per API671 with flexible disc and spacer. Falk Wraplflex type API 671 John Crane

Air piping made according to the category chosen by the client, butt welded, with 100% HT as per ASME B31.3

The moisture separator for the first and final stages, designed for use with max. water content, is provided with automatic and manual drainage routed to common drain point

Oil piping, duplex oil filter and fittings made with SS316L

Canopy made with CS, painted with a cycle as selected by client or made with SS316L, unrefined or painted

Instruments, manifolds, fittings and tubing in SS316L

ENGINEERING DETAIL ELECTRICALS

Clean and simple cable layout routed on SS316L or HDG steel cable tray with cover.

Clean internal layout of control box with clearly numbered components and wiring

MHCL or armoured cable connections, fixed to the container with SS316L or brass coated cable glands (either sealed or open) protected by its hood.

Motors available in all voltages and protection as required by the area classification. Motors selected based on the max. ambient temperature, max. shaft power at a lower intake density and PSV setting. Ex_de motor MV tension 3/3,3 or 5,0 or 11,0 kv /50 /60Hz Ex_de motor low tension 3/400V/50/60 Hz

Compressors also achieved with Caterpillar diesel engine for black start conditions. Motors are sized based on the max. ambient temperature, max. shaft power at a lower intake density and PSV setting. Oil-free screw compressor block Diesel engine CAT

ENGINEERING DETAIL CONTROLS AND AUTOMATION

Process type pressure transmitter by Emerson Rosemont in SS316L with isolation and drainage manifolds

Temperature transmitter made by Emerson Rosemount and installed in a thermowell in SS316L

Allen Bradley PLC for control and protection of the compressor and dryer. Various PLC models available in different solutions with spare channel and different communications available

Allen Bradley /Exxor graphical HMI. For Zone 2 application, the HMI is specially rated for direct installation and external accessibility 12 HMI touch screen with protection 4 HMI touch screen with protection

Dedicated control software for the protection of the package with specific pages for alarms, faults and trend records.

Complete set of approved documentation is supplied during the detailed engineering and at the end of the project

ENGINEERING DETAIL Tests after manufacturing

All packages are finally tested with a dedicated procedure as agreed with the client. Flow, power consumption, vibration and noise are typical tests performed on Blutek assembly plants. Compressor Bearing vibration inspection Compressor performance test Flow measurement Power measurement

Blutek s.r.l. Via Sforzatica,31 24040 Lallio Italy www.blutek.eu THE ONLY SUPPLIER OF INSTRUMENT AIR AND NITROGEN GENERATION PACKAGES FOR HARSH ENVIRONEMENTS ONSHORE OFFSHORE MOBILE SOLUTIONS