Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Similar documents
Identify the following features and specifications for the ESP1

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Nuclear Associates

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Portable Survey Instruments NISP-RP-01

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

ß-Aerosolmonitor FHT 59 C

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

LAUNDRY MONITORING SYSTEM Model # LIM-64S

Radiation Monitoring System RMS

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Radioactive Contamination Monitor

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

WM 00 Conference, February 27 March 2, 2000, Tucson, AZ RELEASE SURVEYING OF SCRAP METALS WITH THE IONSENS CONVEYOR A CASE STUDY

HEALTH AND SAFETY MANUAL

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Microcontroller based design for Tele-sensing and extinguishing fire

Contamination Meter Users Manual

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

Advanced Radiation Measurement Solutions

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

RAM GENE / RAM GENE-1

Understanding total measurement uncertainty in power meters and detectors

Consultation Draft. Issue 2. Good Practice Guide No. 29. The Examination, Testing and Calibration of Installed Radiation Protection Instruments

Measurement Devices. Topic 5 - Audio 56

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

Application Note. Application Note for BAYEX

Research Article Development and Comparison of Fiber-Optic Beta Radiation Sensors with Different Diameters of Their Sensing Probes

AERIAL RADIATION DETECTORS

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

Environmental radioactivity surveillance system of ANPA

CCD and CID solid-state detectors

A comparison of emerging gamma detector technologies for airborne. radiation monitoring

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems

Battery-operated, hand-held alarm and measuring instruments for radiation protection

300/400 UNITS - MODULAR CONFIGURATION

HEALTH AND SAFETY PROGRAM 406 IONIZING/NONIONIZING RADIATION PROTECTION

Radon and Thoron Measurements at Special Underground Circumstances

North American Technical Services

Radiation Monitoring Equipment

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

(12) United States Patent (10) Patent No.: US 7,190,120 B1

UVC Detection as a Potential for Alpha Particle Induced Air Fluorescence Localisation

Remote Gamma Imaging of High Dose Environments

Radiation Control and Monitoring System on the HTTR

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

Saintech Ion Beam Systems - Ion Current Monitor

Technical Manual Ionisation Chamber MUSIC80

Environmental Radiation Monitoring System

Radiation Training for Ancillary Personnel. Introduction

MINI-RADIAC INTRODUCTION

Radiation Alert Frisker INTERNATIONAL

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Surface Contamination Monitor. Operation Manual

Smart Gas Booking and LPG Leakage Detection System

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

MDS. Multi-Detector a/b Counting System. Key Features

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Y. ORMIERES. Fire risk analysis method for nuclear installations

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

Ramon 2.2 Radon-Monitor

High Performance Diesel Fueled Cabin Heater. Abstract

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

ALPHA Radiation Safety Manual

Detector Configurations for the MAJORANA Demonstrator

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Temperature Data Logging

Relevant Radon properties

Provläsningsexemplar / Preview TECHNICAL REPORT. Nuclear medicine instrumentation Routine tests

Lata Mishra Bhabha Atomic Research Centre, INDIA

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

Transcription:

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance D.A.R.Babu, Anand Raman, Ashokkumar P and D.N.Sharma Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai 400085 ABSTRACT. Gas Flow Proportional Counters (GFPC) have been developed indigenously for various radiation protection applications. These detectors can be fabricated for 2 diameter filter paper sample counting applications to large area (~1500 cm 2 ) detectors for surface contamination applications. Thin entrance windows allow nonpenetrating type of radiations like alpha and low energy beta particles. Efficiencies (for alpha and beta radiations) are comparable to conventional detectors used to measure these radiations. Poor gamma efficiency (<1%) compared to ~30% beta efficiency provides a large ß 2 /γ ratio, a high figure of merit and enables efficient gamma background rejection. These detectors are quite suitable for Indian environmental conditions. Three systems have been developed and successfully incorporated in to the radiation surveillance program at various nuclear facilities. The systems based on GFPC detectors include (a) Multiple sample gross alpha counting system, (b) Laundry monitoring system and (c) Alpha hand contamination monitoring system. The first of these enables simultaneous gross alpha counting of five air activity filter paper samples. The area of the detector surface is optimized to cover the 2 sized filter paper samples routinely used for the purpose. Five numbers of GFPC s are arranged sequentially coupled to five individual amplifiers - microcontroller modules to process the signal from the five counters. The laundry monitor which is microcontroller based system consists of four large area multiwire GFPC detectors (700 cm 2 sensitive area) used to monitor alpha contamination of decontaminated laundry. Each detector uses a charge sensitive preamplifier coupled to I 2 C counter. The alpha hand monitoring system consists of four large area multiwire gas flow proportional detectors (330 cm 2 sensitive area each). A microcontroller-based module is employed to initiate the counting process automatically when the hands are inserted in to the suitably designed window slots and provides audio and visual alarm. KEYWORDS: Gas Flow Proportional counter, Contamination monitors, microcontrollers 1. Introduction Monitoring for alpha contamination is an essential component of radiation surveillance program in most nuclear facilities. Alpha contamination monitoring is a difficult and time-consuming process. The entry routes of alpha activity into the human body are inhalation and ingestion. Thus it is very essential to monitor the airborne alpha activity in locations, where significant quantities of alpha activity is being handled. The methodology normally employed to monitor the air activity is through air sampling followed by subsequent counting with an appropriate detector system designed for the purpose. The indigenously designed GFPC (Gas Flow Proportional Counters) are perfectly suitable for use in these types of applications. Personal protective wears (like boiler suits, hand gloves etc) are used extensively by personnel working with radioactive substances. Contamination of these protective wear is unavoidable. Therefore these protective wear has to be checked for presence of radioactivity over its surfaces after decontamination process so that they can be reused later. Laundry monitors based on GFPC have been found to be best suited for this purpose. Also contamination monitoring of hands of plant/radiological laboratory personnel is very important as this could result in internal dose through radionuclide ingestion during food intake. Screening of the hands of the workers for alpha contamination at exit points can help in reducing these internal doses. The hand monitors being developed by the Division are specifically meant to serve this purpose. These three systems mentioned above have been developed and successfully incorporated in to the radiation surveillance program at various nuclear facilities. Email: rajubabu@barc.gov.in 1

2. Design aspects of the GFPC GFPCs of different sizes (2 diameter filter paper sample counting applications to large area ~1500 cm 2 ) are designed for various contamination monitoring applications. The systems developed and described here are for alpha activity measurement purpose and hence the detector entrance window should be as thin as possible. The detector window selected for these applications ~ 0.5-1 mg/cm 2. The multi anode counter is designed using 50-micron diameter anode tungsten wire arranged in parallel with 10 mm spacing between two anodes[1-3]. Since these gas flow type systems are to be operated continuously, selection of gas is very important. Avalanche multiplication occurs at low electric fields in high Z noble gases, hence they are better choice but for economic reasons Argon gas is preferable as primary counting gas. Argon gas is characterized by its non-volatility, chemical inertness and easy availability. A continuous flow of the filled gas is preferred to the sealed gas configuration so as to avoid the problems concerning microscopic leaks. Another important advantage with the flow type proportional counter is the allowance of a reduced window thickness permitting lower energy alpha particles to be counted [4,5]. A comparative study of the ZnS(Ag) based detector system and the GFPC based system for alpha detection is given in Table.1. Table. 1: Comparison of ZnS(Ag) and GFPC based detector Systems Parameter ZnS(Ag) + PMT based system Large area multiwire gas flow counter system Detector sensitive ~ 100 ~ 20-1500 area (cm 2 ) Efficiency (%) ~ 25 at geometrical center ~ 24 (over the entire sensitive area) Efficiency variation over the entire detector sensitive area Less by 60 % at the edges compared to geometrical center of the probe < ±10 % entire sensitive area compared to geometrical centre of the detector Operating voltage (volts) ~ 800 ~ 1300 Plateau No Plateau ~150 v Window thickness ~ 1 mg cm 2 ~1 mg/ cm 2 Since light leakage not a problem here window thickness of 0.5 mg/ cm 2 can be fixed which will further increase the efficiency further. Cost PMT and ZnS(Ag) paper has to Tungsten wire has to be General be imported. Damaged PMT cannot be repaired. Decontamination of detector imported. Any part of the detector can be repaired in-house. 2

Figure-1 gives a general block diagram of the GFPC detector based counting system designed for use in all the monitoring application mentioned above. The two main blocks of the system are: G F P C D e t e c t o r Charge sensitive Pre Amp. High voltage Micro controller based processing module Display/ alarm etc. Analog system: It comprises of a charge sensitive preamplifier, followed by a discriminator and a mono stable multivibrator. The anode signal from each counter is fed to individual preamplifier-discriminator blocks, where they are first amplified and then converted in to TTL pulses. These pulses from individual counters are processed digitally in the microcontroller module. Microcontroller based control system: The microcontroller module carries the required processing depending on the type of application and provides necessary output to the display and audiovisual alarm system. 3. Applications of the GFPC detector 3.1 Gross Alpha Counting System A perspex material based multi-wire gas flow proportional counter design has been implemented for simultaneous gross alpha counting of five air activity filter paper samples. [6] The perspex medium scores over metal, as the contribution to the background from this medium is negligible in comparison to others. The sensitive area of the detector is designed to cover the 2 diameter sized filter paper samples routinely used for the purpose. The detector has a thin entrance window of the order of ~0.5 mg/cm 2 (sealed ~2 dia pancake type GM detectors with entrance window thickness ~2-3 mg/cm 2 are commercially available for alpha detection but their background count rates are higher and are not recommended for this type of applications). Each counter is designed using six anode tungsten wires of 50-micron diameter arranged in parallel with a spacing of 10 mm. This system incorporates a continuous flow (~20cc/mt) of argon gas through five numbers of gas proportional counters arranged sequentially. The system has been designed as a once through type where the fill gas is vented to the atmosphere. The bias required for the total system is obtained from a commercially available, locally manufactured high voltage unit. The bias voltage (~1300 V) is applied commonly to the anode wires of all the counters. Five individual amplifier coupled microcontroller modules process the signal from the five counters. The timing aspect for the system is commonly arranged for all the five counters and is user selectable from a rotary switch provided on the front panel. The samples to be counted are placed on five independent sample drawer type assemblies. Care is taken to maintain minimum distance (~ 4 mm) between samples to detector window. The drawer assembly has 3

two positions i.e. when drawer is pushed in, the sample will be counted and when pushed out, the detector will see small standard alpha source. This provision will be useful to check the efficiency of the detector when required. The pre amplifier pulses are processed and converted in to TTL pulse for further analysis by microcontroller. The microcontroller module comprises of five identically programmed Atmel make 89C2051 microcontroller chip. Three timing modes are available to the user for setting the counting time for the counters, which are 60secs, 1800secs and manual. The counts from each of the counter are displayed on a 6 digit seven segment LED display. The elapsed time during the counting process is also displayed on a 6-digit seven-segment display in terms of seconds. The operating voltage of the detector can be viewed by pressing the EHT display button. 3.2 Laundry Monitor One of the protective measures at all nuclear facilities for minimizing radioactive contamination is to wear personal protective wears (like boiler suits, frog suits, plastic suits, hand gloves, cotton overshoes etc). Laundry from various facilities is sent to Decontamination Centre (DC). These are to be checked for presence of radioactivity over its surfaces after decontamination process. After checking surfaces contamination, these protective wear (free from contamination) can be reused. Large quantities of these protective wears are being handled at DC. Considerable amount of man-hours are spent to monitor all these wears. In addition alpha contamination limits are almost one tenth of beta/gamma contamination limits which makes the monitoring much more stringent. This requirement can be fulfilled only by detectors, which have large area, good efficiency and are rugged. Since GFPC detectors can fulfill all these basic requirements, large area multi-wire gas flow detectors were used in development of this system. Four large area multiwire gas flow proportional detectors (~ 700 cm 2 sensitive area each) developed in RSSD are used to monitor alpha contamination of decontaminated laundry. Each detector is coupled to charge sensitive preamplifier. Each preamplifier also contains I 2 C counter. Processor based counter timer circuit reads the counts accumulated in these counters. This block is also used to set the counting time and alarm levels. With present system, time required for monitoring the laundry has considerably reduced. Since the entire system is indigenously designed, maintenance of the system is easy. Gas based system has uniform response over the entire sensitive area. Since the system requires commercial grade argon, which is readily available, replacement of cylinder is once in three months may not be a problem looking into its other advantages. 3.3 Alpha Hand contamination monitor Another important radiation surveillance requirement in many nuclear facilities is the monitoring of hands and feet of working personnel at the plant before they leave the workplace. This includes radiation monitoring for alpha and beta/gamma contamination. At the waste management facility of BARC, the need for a hand contamination monitor was responded to with a GFPC based alpha hand contamination monitor. Four multiwire gas flow proportional counters were employed where two each were used to monitor two sides of one hand. 4

The detectors designed for the application have an area of 330 cm 2 and efficiency of ~ 24 % for alpha particle detection. The operating voltage for the systems is set at ~ 1300 V and the plateau length is observed to be ~ 150 V. Since large area, the window thickness for the detectors is kept at ~ 1 mg/ cm 2 so as to facilitate transmission of alpha particles and at the same time gives better protection compared to 0.5 mg/cm 2. The detectors have been coupled to charge sensitive preamplifiers, the output of which get converted to TTL pulses. These pulses are fed as input to an Atmel make 89c2051 microcontroller module, and counted for predetermined time interval. An optimum counting time of 10 seconds has been fixed. The module has provision for displaying counts on each hand on two individual LCD display units. The system also has audiovisual alarms, which are set on whenever the contamination levels cross the preset limits. The counting process is initiated whenever any individual inserts his hands in to the slots meant for the purpose and any abnormal interruption during the counting process is also indicated through suitable audiovisual indications. 4. Conclusions Gas detectors have been developed indigenously for various radiation protection applications. Thin entrance windows to allow non-penetrating type of radiations like alpha and low energy beta particles can be provided for GFPC detectors. The minimum detectable limit values have been computed for the three systems and are shown in Table 2. Table-2: Minimum Detectable Activities System Background (Counting time Minimum Detectable Activity normalized to 600 seconds) ( for counting time:600secs) Gross alpha counting system 2 counts 25 mbq Laundry monitor 40 counts 0.12 Bq Hand monitor 25 counts 0.14 Bq Damage (this is quite frequent in plant operations) to these windows is easily repairable. Efficiencies (for alpha and beta radiations) are comparable to conventional detectors used to measure these radiations. The operating voltage for alpha detection is very much less than that for beta/gamma and hence the background counts will be low. These detectors are quite suitable for Indian environmental conditions. Gas handling in flow type of detectors is not a hindrance when compared to other advantages of these detectors. Acknowledgements We gratefully thank the support and encouragement provided by Shri.H.S.Khushawaha, Director, Health, Safety and Environment Group. We also acknowledge the cooperation and support extended by all our colleagues at RSSD in carrying out the development of this Division. References [1] Knoll, G.F., Radiation Detection and Measurement, Wiley Publication, New York(1989). [2] Leo, W.R., Techniques for Nuclear and Particle Physics Experiments, Narosa Publications. [3] Price, W.J., Nuclear Radiation Detection, McGraw-Hill Publication, New York(1964). [4] D.A.R.Babu et.al., Development and application of gas flow proportional counter for contamination monitoring (Proc. 27 th IARP Conf, Mumbai,2005) 447-448 5

[5] Samant., R.K. et al., HP 2000Portal monitor and other allied instrumentation based around indigenously developed large area, multiwire proportional counters, SAINR-93, (Proc. Symp, Mumbai 1993). [6] D.A.R.Babu et.al., Gross alpha counting system based on an innovative gas flow proportional counter, (Proc. of NUCAR,Amritsar,2005)679-684 6