Dissolved Oxygen Measurement liquisys M COM 223 / 253

Similar documents
Dissolved Oxygen Measurement liquisys S COM 223 / 253

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

Dissolved Oxygen Analyzers

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

02/11/2015

Process Alarm Module RTA 421

SECTION Fluorescent Dissolved Oxygen Measuring System

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

OOM 223 Transmitter for Dissolved Oxygen

02/11/2015

Inductive Conductivity

I/A Series 716C 1/16 DIN Temperature Controller

Turbimax CUE21 / CUE22

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Temperature Controllers

1 4 DIN Dissolved Oxygen Controller

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

MultiFix Central unit

LC2200 Level Controller Installation and Maintenance Instructions

UDC100 Universal Digital Controller Specifications

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Concise catalogue Water-Industry

Steam and Water Analysers

MEAS CAL ALARM WASH CONF APT4000 TC

Turbimax CUE21 / CUE22

Toroidal Conductivity Transmitters Series APT4000 Specifications

1.7. Insulation fault evaluators EDS460/490 EDS461/491

TEC2100 Series Networked Thermostats

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Ultrasonic Level Measurement nivopuls FDU 10 S

Dräger Polytron 7000 Fixed gas detector

Condumax CLS16 and CLS16D

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Continuous Gas Analyzers, extractive

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Software Version 2.01 LEVEL MONITOR MODEL 220

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

WIO200 Water In Oil measuring instrument

Oxygen (O2) Single-Point Gas Detection System

Safety instrumented systems

Plug-in Base, Long Range Sensor E3B2

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Free Chlorine Measuring System

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

On the job around the clock 24/7: Fire detection systems

1.7. Insulation fault evaluators EDS460/490 EDS461/491

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

PolyGard 2-channel Gas Controller MGC-03

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

PROFIBUS-PA Display RID 261 PROFIBUS-PA

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Dräger Polytron 8000 Stationary gas detector (EC)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

DTA04. Motor thermistor relay. Benefits. Description

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Low Temperature Zirconia Oxygen Analyzer

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

UDC 700 Universal Digital Controllers and Indicator Specifications

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Gas cylinder scale Model GCS-1

FIL-SPL Flow-through heater for central heating USER MANUAL

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Series 5000 Hydrazine Analyzer Model 60002

Model Q45P/R. ph/orp Monitor...

MultiFix Central unit

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Instruction Manual. Aquacon Conductivity Controller / Transmitter

LC1350 Level Controller

SCHMIDT LED Measured Value Display MD Instructions for Use

Stand Alone DYNAGARD SP Operation Manual

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Level gauges Series LS Level indicator, switch and transmitter for liquids

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Model Q45P/R. ph/orp Monitor...

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Series Temperature Controller Instruction Sheet

DTA. Motor thermistor relay. Benefits. Description

/8 DIN Level Indicator

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 3490 Series

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SECTION Free/Available Chlorine Analysis System

SECTION ph/orp Sensors

Transcription:

Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design, the Liquisys S COM 223 / 253 controller can be adapted to a wide range of customer needs. The basic version, which provides simple measuring and alarm signaling functions, can be equipped with additional software and hardware modules to match specific applications. Retrofitting of expansion modules is also possible. Areas of application Waste water treatment plants Effluent treatment Water treatment and water monitoring Drinking water Surface water: rivers, lakes, ocean Fish farming Measuring controller in field or panel-mounted housing Universal application Switchable between oxygen concentration in mg/l and saturation index in % SAT via software switching (mg/l = ppm) Simple handling Logically arranged menu structure with plain text in 6 languages facilitates instrument configuration Large, two-line display indicates measured value and temperature at the same time Simple one-point calibration in air or in the medium Safe Operation Overvoltage (lightning) protection according to EN 61000-4-5 Direct access for manual contact control CSA GP* and CE approved * please consult factory The basic unit can be extended with: 2 or 4 contacts for use as: Limit contacts (also for temperature) PID controller Timer for simple rinse processes Complete cleaning with Chemoclean Plus package: Automatic pressure compensation Any current output configuration via table Automatic initiation of cleaning in case of alarm or limit violation Live check of sensor Process monitoring HART or PROFIBUS PA and DP 2nd current output for temperature

Details Liquisys M COM 223 / 253 provides a solution for all water and waste water treatment applications. The DS version provides additional functions: Features of the basic version (DX): Measurement of oxygen concentration in mg/l or % saturation This is selected via the menu. The temperature is displayed at the same time or, if desired, not shown at all. p The oxygen concentration not only depends on the local altitude, but also on the weather (air pressure). The automatic pressure compensation function takes these fluctuations into account. The COS 41 sensor has no zero current and therefore only requires one-point calibration. This is performed in air (corresponding to 100% saturation) or by reference calibration in the medium. E 017 E 123 - - - - on off on 2.4 / 22 ma off on off Different alarms are required depending on application and operator. Therefore the Liquisys M COM 223 / 253 permits independent configuration of the alarm contact and error current for each individual error. Unnecessary or undesirable alarms can be suppressed in this manner. 20 ma 0 In order to display wide measuring ranges while still achieving a high resolution in specific ranges, the current output can be configured as required via a table. This permits bilinear or quasi-logarithmic curves. 20 ma 0 t The live check issues an alarm when the sensor signal does not change over a defined period of time. This may be caused by blocking, passivation, or separation from the process. on off Timer t on off on off Chemoclean t Up to four contacts can be used as limit contacts (also for temperature), to implement a PID controller or for cleaning functions. The Process Check System is used to monitor adjustable time intervals, e.g. for permanent aeration or permanent absence of aeration. Direct manual operation of the contacts (bypassing the menu) provides quick access to limit, control or cleaning contacts, permitting speedy correction of deviations. Instrument DATA Se r Nr I1 1356348 The serial numbers of the instrument and modules and the order code can be called up on the display. 2

Basic Version and Plus Package Alarm signaling MEASUREMENT CALIBRATION Read instrument DATA Basic Version Alarm signaling With plus package (DS version) Automatic PRESSURE COMPENSATION PROCESS CHECK SYSTEM for monitoring, e.g. of aeration Linear CURRENT OUTPUT CURRENT OUTPUT simulation LIVE CHECK of sensor 1 programmable ALARM CONTACT CURRENT OUTPUT programmable (table) (contact and error current) Additional features Additional features Controlling Controlling 2 CHANGEOVER CONTACTS for - Measuring parameter limit - Temperature limit Automatic cleaning triggered by alarm or limit - PID controller violation - Timer for cleaning Additional features Additional features Cleaning Cleaning 2 more CHANGEOVER CONTACTS (total of 4) for - Measuring parameter limit - Temperature limit Cleaning triggered externally or automatically - PID controller by alarm or limit violation - Chemoclean cleaning (water and cleaning agent) Measuring and Control System Mounting example with Liquisys M COM 223 / 253 A complete measuring system comprises: the oxygen controller Liquisys M COM 223 or COM 253 an oxygen sensor COS 41 with an integrated NTC temperature sensor an immersion, flow or retractable holder Weather protection Options: extension cable (type CMK), and junction box VBM Liquisys M COM 253 ENDRESS+HAUSER LIQUISYS Up to 4 relays Alarm contact CAL E REL ALARM Signal output 1: oxygen Signal output 2: temperature (optional) Aux. 15 V supply voltage 2 digital inputs Immersion holder CYA 611 Power supply Oxygen sensor COS 41 Retractable holder COA 461 Liquisys M COM 223 ENDRESS+HAUSER LIQUISYS CAL E REL ALARM 3

Operation Field for user labeling Key for manual relay switching Liquid crystal display for display of measured values, configuration data and current menu field LED indicator for alarm function User interface: Display and keys 4 main control keys for calibration and instrument configuration Key for switching between automatic and manual relay operation LED indicators for switched limit outputs Everything at a glance The display simultaneously shows the current measured value and the temperature the essential process data. Brief informational texts in the configuration menu provide assistance with parameter configuration. Intelligent and simple All instrument control functions are arranged in a logical menu structure. Following access code entry, the individual parameters can be easily selected and modified as needed. CALIBRATION Calibration in air or in the medium Display MEAS. VALUE TEMPERATURE Current temperature display can be suppressed by pressing the PLUS key Display of active errors (sequence according to priority) SETUP 1 Selection of measurement type and unit, adjustment of measured value filter, altitude adjustment SETUP 2 Temperature measurement, salinity correction CURRENT OUTPUT Adjustment of current output assignment, curve and simulation for verification ALARM User adjustment of errors to switch relay or generate error current (S version: automatic cleaning trigger in the event of an alarm) CHECK Process Check System and live check alarm adjustment Overview of Liquisys M COM 223 / 253 menu. This covers all the options that can be installed (see page 2 Details). RELAYS SERVICE 4 Up to 4 relays may be configured as limit contacts, PID controller, timer or for chemical cleaning (S version: automatic cleaning trigger in case of limit violation) Selection of language version, display of software or hardware serial numbers, entry of access codes

Electrical Connection All connections to the panel-mounted instrument COM 223 are established via the terminal strips on the rear. In the case of the field instrument COM 253, all wires (including the sensor cable) are connected to terminals in a separate wiring compartment. All the wiring can remain in place if the instrument needs repair because all repairs are limited to assembly replacement. Dismantling the instrument and rewiring is not necessary. E Left: Liquisys M COM 223, connections on the rear of the instrument Right: Liquisys M COM 253, rear of instrument with replaceable electronics box (E) Sensor COS 41 S NTC bn rd 11 12 41 42 43 Alarm* K A K gn A 90 91 47 48 49 Relay 1* Signal output 1: oxygen 31 32 ma 57 58 59 Relay 2* Signal output 2: temperature (optional) 33 34 ma 51 52 53 Relay 3* 81 54 Digital input 1 10 to 50 V 82 55 56 Relay 4* Digital input 2 10 to 50 V 93 94 optional *Contact status shown: no current or fault present Aux. voltage output 85 86 15 V = L L+ N L Power supply Electrical connection of Liquisys M COM 223 / 253 5

CAL ENDRESS+HAUSER LIQUISYS REL ALARM Dimensions ENDRESS+HAUSER LIQUISYS 3.78 (96) CAL E REL ALARM 3.54 (90) 0.24 (6) 5.47 (139) Dimensions of Liquisys M COM 223 0.43 (11) E Ø 0.24 (6) 6.18 (157) 2.75 (70) 9.72 (247) 4.53 (115) 2.75 (70) 6.06 (154) 6.69 (170) Dimensions of Liquisys M COM 253 6

Mounting of Liquisys M COM 223 The panel-mounted version is mounted using the supplied tensioning screws. The required overall mounting depth is approximately 6.89 in. (175 mm). Flat gasket (included in delivery) Mounting cutout according to DIN 43700 3.62 +0.02 (92 +0.5 ) 3.54 (90) 2.24 (57) 1.30 (33) 3.78 (96) 3.62 +0.02 (92 +0.5 ) Installation of panelmounted housing approx. 0.98 (25) max. 1.77 (45) 5.47 (139) 0.24 (6) 7

Mounting of Liquisys M COM 253 3.54 (90) 2.76 (70) 1.18 (30) Ø 0.31 (8) 3.54 (90) 2.76 (70) 0.24 (M 6) Ø 0.31 (8) 2.36 (60) Post mounting kit for installation of field housing on cylindrical pipes (horizontal or vertical, max. Ø 2.36 (60 mm); see Accessories) 2.76 (70) 3.54 (90) Ø 0.24 (6) Mounting on cylindrical pipes (shown with weather protection cover installed on right) 6.18 (157) Ø 0.31 (8) Wall mounting Screws: Ø 0.24 (6 mm) Anchors: Ø 0.31 (8 mm) 0.63 (16) 4.53 (115) 8

Technical Data General specifications Manufacturer Endress+Hauser Product designation Liquisys M COM 223 Liquisys M COM 253 Input Measured quantities / temperature measurement with sensor COS 41 Display and measuring range 0 to 20 mg/l or 0 to 200% SAT (1 mg/l = 1 ppm) Temperature compensation range 0 to 122 F (0 to 50 C) Pressure compensation range (optional) 0 to 1200 hpa Altitude adjustment range 0 to 13,300 ft. (0 to 4000 m) Salinity adjustment range 0 to 4% signal input Signal current 0 to 3000 na Slope adaptation 75 to 140% of nominal slope Nominal slope (sensor in air, 20 C, 1013 mbar) 290 na Maximum length of cable to sensor 160 ft. (50 m) Temperature measurement Temperature sensor Measuring range Temperature offset range NTC, 30 kω at 77 F (25 C) 14 to 140 F (- 10 to + 60 C) ± 68 F (± 20 C) Digital inputs 1 and 2 Voltage Current consumption 10 to 50 V max. 10 ma Output signal output Current range 0 / 4 to 20 ma, galvanically separated; error current 2.4 / 22 ma Load max. 500 Ω Output range 2 to 20 mg/l or 20 to 200% SAT Isolation voltage max 350 V rms / 500 V DC Overvoltage (lightning) protection acc. to EN 61000-4-5: 1995 Temperature signal output (optional) Current range 0 / 4 to 20 ma, galvanically separated Load max. 500 Ω Output range adjustable, 10 to 100% of upper range value Isolation voltage max 350 V rms / 500 V DC Overvoltage (lightning) protection acc. to EN 61000-4-5: 1995 Auxiliary voltage output Output voltage Output current 15 V ± 0.6 VDC max. 30 ma Contact outputs (floating changeover contacts) Switching current with ohmic load (cos ϕ = 1) Switching current with inductive load (cos ϕ = 0.4) Switching voltage Switching power with ohmic load (cos ϕ = 1) Switching power with inductive load (cos ϕ = 0.4) max. 2 A max. 2 A max. 250 V AC, 30 V DC max. 1250 VA AC, 150 W DC max. 500 VA AC, 90 W DC Limit contactor Limit adjustment range Pickup / dropout delay 0 to 20 mg/l or 0 to 200% SAT 0 to 7200 seconds 9

Technical Data (continued) Output (continued) Controller Function (adjustable) Pulse length / pulse frequency controller Controller response PID Proportional band Kp: 0.10 to 10.00 Period for pulse length controller 0.5 to 999.9 seconds Frequency for pulse frequency controller 60 to 180 min -1 Alarm Function (switchable) Alarm threshold adjustment range Alarm delay Monitoring time for lower limit violation Monitoring time for upper limit violation steady / fleeting contact; normally closed / open / temperature: complete measuring range 2 to 2000 seconds 0 to 2000 min 0 to 2000 min Accuracy measurement with sensor COS 41 Resolution Deviation of indication 1 Reproducibility Measurement deviation 1, signal output 0.01 mg/l or 0.1% SAT max. 0.5% of measuring range max. 0.2% of measuring range max. 0.75% of measuring range Temperature measurement Resolution 0.2 F or 0.1 C Deviation of indication 1 max. 1.0% of measuring range Measurement deviation 1, temperature signal output max. 1.25% of current output range Ambient conditions Nominal operating temperature 14 to 131 F (-10 to +55 C) Ambient temperature (limit operating conditions) -4 to 140 F (-20 to +60 C) Storage and transport temperature -13 to 149 F (-25 to +65 C) Relative humidity (nominal operating conditions) 10 to 95%, non-condensing Protection class of panel-mounted unit NEMA 3S (IP 54 (front), IP 30 (housing)) Protection class of field housing NEMA 4X (IP 65) Electromagnetic compatibility interference emission acc. to EN 50081-1: 1992 interference immunity acc. to EN 50082-2: 1995 Physical data / design Dimensions of panel-mounted unit (H x W x D) Installation depth Dimensions of field housing (H x W x D) Weight of panel-mounted unit Weight with field housing Display 3.78 x 3.78 x 5.71 in. (96 x 96 x 145 mm) approx. 6.89 in. (175 mm) 9.72 x 6.69 x 4.53 in. (247 x 170 x 115 mm) max. 1.54 lb. (0.7 kg) max 5.07 lb. (2.3 kg) LC display, two lines, five and nine digits, with status indicators Materials Housing of panel-mounted unit Front membrane Field housing polycarbonate polyester, UV-resistant ABS PC Fr Power requirements Supply voltage Power consumption Fuse protection 100 / 115 / 230 V AC +10 / -15%, 48 to 62 Hz 24 V AC/DC +20 / -15% max. 7.5 VA fine-wire fuse, medium time-lag, 250 V / 1 A ¹acc. to IEC 746-1, for nominal operating conditions Subject to modifications. 10

Accessories Mounting accessories Type Features Order number Pendulum For pendulum suspension of assemblies 50080196 frame e.g. CYA 611 Material: 304 SS Post mounting Kit for mounting of field housing on 50086842 kit horizontal or vertical pipes, max. diameter, 2.5 (60 mm) Material: 304 SS Holders Type Features Applications CYA 611 Immersion assembly with G 1, G 3/4 Sewage, water or 3/4 NPT thread COA 250 Flow holder with screwed G 3/4 measuring Installation for flow connection operating, e.g. in waterworks or analytical cabinets Probfit Retractable holder with DN 50 or 2 ANSI Installation for in-line COA 461 flange operation, e.g. in pipelines or on tank walls COA 110-50 Floating immersion holder Waste water, water, in basins with changing levels Oxygen sensor Type Features Applications COS 41 Amperometric two-electrode sensor in Waste water, drinking all plastic housing with permanently water, surface water, attached cable, cable length 22 ft. (7 m) fish farming or 50 ft. (15 m), protection class NEMA 6P (IP 68), with integrated temperature sensor Cables Type Features Order number VBM Junction box for extension of cable 51500177 connection between measuring cable and instrument, protection type NEMA 4X (IP 65) CMK Special measuring cable for extension of 50005374 line between transmitter and junction box VBM 11

Product structure Oxygen transmitter Liquisys M COM 223 / COM 253 COM 233-1 2 3 4 COM 253-1 2 3 4 1 Version DX Oxygen measurement DS Oxygen measurement, automatic pressure compensation, additional functions 2 Power Supply 0 230 VAC 1 115 VAC 2 230 VAC, CSA general purpose 3 115 VAC, CSA general purpose 5 100 VAC 7 24 VAC / VDC, CSA general purpose 8 24 VAC / VDC 3 Measurement output 0 Oxygen 1 Oxygen and temperature 3 Profibus PA 4 Profibus DP 5 Oxygen with HART 6 Oxygen with HART and temperature 4 Contacts 05 No additional contacts 10 2 contacts (limit / PID / timer) 15 4 contacts (limit / PID / Chemoclean) 16 4 contacts (limit / PID / timer) 1 Version DX Oxygen measurement DS Oxygen measurement, automatic pressure compensation, additional functions 2 Power Supply 0 230 VAC 1 115 VAC 2 230 VAC, CSA general purpose 3 115 VAC, CSA general purpose 5 100 VAC 7 24 VAC / VDC, CSA general purpose 8 24 VAC / VDC 3 Measurement output 0 Oxygen 1 Oxygen and temperature 3 Profibus PA 4 Profibus DP 5 Oxygen with HART 6 Oxygen with HART and temperature 4 Contacts 05 No additional contacts 10 2 contacts (limit / PID / timer) 15 4 contacts (limit / PID / Chemoclean) 16 4 contacts (limit / PID / timer) For application and selection assistance, in the U.S. call 888-ENDRESS For total support of your installed base, 24 hours a day, in the U.S. call 800-642-8737 Visit us on our web site, www.us.endress.com United States Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 Phone: (317) 535-7138 888-ENDRESS FAX: (317) 535-8498 Canada Endress+Hauser Canada Ltd. 1440 Graham s Lane Unit 1, Burlington ON, L7S 1W3 Phone: (905) 681-9292 800-668-3199 FAX: (905) 681-9444 Mexico Endress+Hauser Paseo del Pedregal No. 610 Col. Jardines del Pedregal 01900, Mexico D.F. Mexico Phone: (525) 568-2405 FAX: (525) 568-7459 Endress+Hauser The Power of Know How TI 199C/24/ae/05.02 2002 Endress+Hauser, Inc.