Dräger Catalytic Ex-Sensors DrägerSensors

Similar documents
Dräger Catalytic Ex-Sensors DrägerSensors

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Bump Test Station Calibration and Bump Testing

Dräger X-am 2500 Multi-Gas Detector

Dräger X-am 2500 Multi-Gas Detection

Dräger Configuration and Evaluation Software

Dräger Pac 5500 Single-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detector

Dräger X-am 5000 Multi-Gas Detection

Dräger Pac 6000 Single-Gas Detection Device

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Pac 8500 Single-Gas Detection Device

Dräger X-am 7000 Multi-Gas Detection

Dräger Pac 8000 Single-Gas Detection Device

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Pac 3500 Single-Gas Detection Device

Training Authorised Gas Tester Level 1. Basic Information

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

On-site & Shutdown Safety Service CSE Monitoring

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Pac 7000 Single-Gas Detection Device

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

Training Gas Detection Level 3 Maintenance and Repair

Foam Extinguisher AB - composite Portable foam extinguishers

Powder Extinguisher ABC - composite Portable powder extinguishers

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger GS01 (wireless) Detection of flammable gases and vapours

GS01 (wireless) Detection of flammable gases and vapours

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Dräger QuadGard Control System

Dräger REGARD -1 Control System

Dräger REGARD 3900 Series Control System

Portable wet chemical extinguishers

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Bodyguard 1000 Warning Device

Dräger PEX 3000 Flammable Gas Detection

Dräger OR Lights Simply good light

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Flame 5000 Flame Detection

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger Polytron 8200 Stationary gas detector (CatEx)

The SharpEye 40/40I (IR3) Flame Detection

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger VVP 1000 System Components

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger Flame 2100 (UV) Flame Detection

Dräger X-zone 5500 Multi-Gas Detection Device

D D D Dräger Gas Detection ST Dräger: Technology for Life

Oxylog VE300 Emergency & Transport Ventilation

Dräger Polytron 7000 Detection of toxic gases and oxygen

Oxylog VE300 Emergency & Transport Ventilation

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Dräger X-am 7000 Multi-Gas Detection

Dräger Flame 5000 Flame Detection

Tropic 2.0 ultrasonic nebuliser

Dräger PIR 7000 Flammable Gas Detection

Dräger Pac 3500 Single-Gas Detection Device

The SharpEye 40/40M (Multi IR) Flame Detection

VarioVac vacuum regulators Consumables and Accessories

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger Pac 8500 Single-Gas Detector

Dräger Pac 6000 Single-Gas Detector

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Flame 2500 (IR3) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Polytron 8000 Stationary gas detector (EC)

D Moving beyond telemetry INFINITY M300

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

Oxylog VE300 Emergency & Transport Ventilation

The SharpEye 40/40R (IR) Flame Detection

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger X-zone 5500 Area Monitoring

Dräger Flame 2100 Flame Detection

Dräger REGARD -1 Control System

ST Safety to go. DRÄGER PORTABLE GAS DETECTION INSTRUMENTS

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8310 Stationary gas detector (DSIR)

Infinity M300+ Telemetry

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Properly calibrating catalytic bead sensors: A practical guide

Dräger Flame 2500 Flame Detection

Transcription:

Dräger Catalytic Ex-Sensors DrägerSensors High product quality, low operational costs: Thanks to DrägerSensor CatEx PR technology, our sensors are resistant to poisoning and particularly stable over the long-term. They also deliver fast response times for rapid warnings of gas hazards. D-27736-2017

02 Dräger Catalytic Ex-Sensors Benefits Our own design We develop the sensors with our own engineering knowledge. In this way, we can assure their quality and we know the measurements are accurate. This allows them to be fully utilised in combination with our full line of inhouse developed Dräger gas detectors. Durable and resistant against sensor poisons Hydrogen sulphide and silicone are known catalytic poisons that may be present in environments where explosive gases can develop. Thanks to a new pellistor composition, the sensors are highly resistant to poisoning from these substances. The sensors are also lead-free and thereby adhere to Directive 2002/95/EG (Restriction of Hazardous Substances). The high resistance to poisoning leads to extraordinarily stability over the long-term and that ensures low operational costs. Vapour sensitivity Unknown gas hazards and higher hydrocarbons pose a particular challenge to the display sensitivity of catalytic sensors. The new CatEx PR sensors distinguish themselves through their sensitivity. The detection of all hydrocarbons (from methane to nonane) has been certified in a measurement performance certificate for the device series X-am 1/2/5000, X-am 7000 and X-am 8000. Rapid response times A rapid warning for explosive gases and vapours is vital. The CatEx PR sensors' fast response times minimise the timespan between danger and warning. From the LEL to 100 vol. % Our catalytic sensors are suitable for measurements from the lower explosion limit to 100 vol. %. The X-am 8000 features the option to automatically switch testing ranges, making it easier to read off results when monitoring for high methane concentrations: if the sensor measures values above 100% LEL, the display switches to the range of 0 to 100 vol. %.

Dräger Catalytic Ex-Sensors 03 System Components Dräger X-am 2500 The Dräger X-am 2500 was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O 2, CO, H 2 S, NO 2 and SO 2. Reliable and fully mature measuring technology, durable sensors and easy handling ensure a high degree of safety with extremely low operating costs. D-14325-2017 D-59024-2012 Dräger X-am 5000 The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of toxic gases, organic vapors, Odorant and Amine. Dräger X-am 7000 Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the reliable detection of oxygen, toxic and combustible gases and vapors are necessary. D-6491-2017 ST-67-2006 Dräger X-am 8000 Clearance measurement was never this easy and convenient: The 1 to 7 gas detector detects toxic and flammable gases as well as vapours and oxygen all at once either in pump or diffusion mode. Innovative signalling design and handy assistant functions ensure complete safety throughout the process.

04 Dräger Catalytic Ex-Sensors Related Products Dräger Infrared Sensors Dräger infrared sensors deliver the best-possible measurement results and are unaffected by sensor poisons. The long service life of these sensors results in hardly any follow-up costs. You can also use Dräger infrared sensors to take Ex and CO 2 measurements simultaneously. D-13891-2017 D-2105-2011 PID sensors PID sensors are the ideal choice for detecting low concentrations of volatile organic compounds. A PID (photoionization detector) is used to measure hazardous substance groups or can even be adjusted to measure individual substances. DrägerSensor XS DrägerSensors can be used for detecting many different gases and vapours. We develop and produce the DrägerSensors ourselves. Additionally, you benefit from the sensors' long service life and low operating costs. D-12191-2010 ST-299-2001 DrägerSensor XXS Dräger has developed miniature electrochemical sensors specially for the Dräger Pac, X-am 1/2/5 and X-am 8000 generation. The sensors detect many different gases and vapours. They are also very reliable and stable over the long-term, thereby reducing your operating costs.

Dräger Catalytic Ex-Sensors 05 Ordering Information Description DrägerSensor CatEx 125 PR DrägerSensor CatEx 125 PR-Gas DrägerSensor Smart CatEx PR DrägerSensor Smart CatEx PR FR DrägerSensor Smart CatEx PR HC Measuring range Detection of Device Order no. 0 100 % LEL or Gases and vapours Dräger X-am 2500, 0 100 Vol.-% CH 4 Dräger X-am 5000, Dräger X-am 8000 0 100 % LEL or Gases Dräger X-am 2500, 0 100 Vol.-% CH 4 Dräger X-am 5000, Dräger X-am 8000 68 12 950 68 13 080 0 100 % LEL Gases and vapours Dräger X-am 7000 68 12 980 0 100 % LEL or only Methane Dräger X-am 7000 68 12 975 0 100 Vol.-% CH 4 0 100 % LEL or Gases and vapours Dräger X-am 7000 68 12 970 0 100 Vol.-% CH 4

06 Dräger Catalytic Ex-Sensors Notes Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. 90 45 546 17.11-4 HQ PP Subject to modifications 2017 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com REGION DACH Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION EUROPE Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co. KGaA Branch Office P.O. Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draeger.com REGION ASIA PACIFIC Draeger Singapore Pte. Ltd. 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asia.pacific@draeger.com REGION CENTRAL AND SOUTH AMERICA Dräger Panama S. de R.L. 59 East Street, Nuevo Paitilla House 30, San Francisco Town Panama City, Panama Tel +507 377 9100 Fax +507 377 9130 servicioalcliente@draeger.com Locate your Regional Sales Representative at: www.draeger.com/contact