Confirmation of Product Type Approval

Similar documents
TYPE APPROVAL CERTIFICATE

HYUNDAI HEAVY INDUSTRIES CO., LTD.

Fire Protection & Jacket Repair Of Electrical Cables

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

TYPE APPROVAL CERTIFICATE

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

TYPE APPROVAL CERTIFICATE

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

TYPE APPROVAL CERTIFICATE

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

SOUND RECEPTION SYSTEM

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Koja Oy. manufactures ventilation units Fair 80 ec

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

AS/NZS TR IEC :2012

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

INTERNATIONAL STANDARD

Shipboard incinerators with capacities up to 4000 kw


SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

DNVGL-CP-0398 Edition December 2015

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

Annunciator unit. Application

LED Linear Design Highlights

EC TYPE EXAMINATION (MODULE B) CERTIFICATE (EC-US MRA)

TPF Series Ozone Generators

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Lloyd s Register Type Approval System Test Specification Number 3

Gas cylinder scale Model GCS-1

REA 105 Arc Protection Module. Operator s Manual

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

Operating Guide Safe Torque Off

INTERNATIONAL STANDARD

Rules for Classification and Construction Additional Rules and Guidelines

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

Notified Body No.: 0575

Annunciator Unit SACO 16 D1. Product Guide

TYPE APPROVAL CERTIFICATE

62 MAX/62 MAX + Infrared Thermometer

INTERNATIONAL STANDARD

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

INTERNATIONAL STANDARD

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

Guideline No.: S-02(201510) S-02 Navigation Light and Signal Light Controllers. Issued date: October 20,2015. China Classification Society

MT4 MAX/MT4 MAX + Infrared Thermometer

Hazardous Area Zirconia Oxygen Systems

INTERNATIONAL STANDARD

TYPE APPROVAL CERTIFICATE

ACMA mandated EMC standards

Original instructions Sense7-series Non-contact coded safety switch

Type TEC, Transformer Electronic Control System

AO Annunciator Module

INTERNATIONAL STANDARD

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Fan Heaters Type VLEx

Test Report. Appliance EMF Testing

KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

GLEB Kitchen exhaust fan

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

G & M Power Plant Ltd CORPORATE OVERVIEW. MARINE & INDUSTRIAL DIESEL GENERATORS 10 TO 2000kw. 27/07/2010 G&M Power Ltd

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

INTERNATIONAL STANDARD

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

62 MAX/62 MAX + Infrared Thermometer

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Audible warning devices for external alarm

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

APS-Series 1500VDC OUTDOOR SOLAR INVERTER

Type Approval Certificate

Notified Body No.: 0575

INTERNATIONAL STANDARD

PowerWave 2 Busway System

GROUNDING AVOIDANCE SYSTEM (GAS)

AS/NZS IEC :2015

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

IACS RESOLUTION CHANGES (GMO ) BEKİR SITKI TÜRKMEN

ABB drives. Technical guide No. 2 EU Council Directives and adjustable speed electrical power drive systems

TYPE APPROVAL CERTIFICATE

INTERNATIONAL STANDARD

Operating Manual MS220KA and MSR220KA

62 MAX/62 MAX + Infrared Thermometer. Users Manual

APS-Series 1000VDC OUTDOOR SOLAR INVERTER

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Transcription:

16/FEB/2017 Confirmation of Product Type Approval Please refer to the "Service Restrictions" shown below to determine if Unit Certification is required for this product. This certificate reflects the information on the product in the ABS Records as of the date and time the certificate is printed. Pursuant to the Rules of the American Bureau of Shipping (ABS), the manufacturer of the below listed product held a valid Manufacturing Assessment (MA) with expiration date of 04-JAN-2022. The continued validity of the Manufacturing Assessment is dependent on completion of satisfactory audits as required by the ABS Rules. And; a Product Design Assessment (PDA) valid until subject to continued compliance with the Rules or standards used in the evaluation of the product. The above entitle the product to be called Product Type Approved. The Product Design Assessment is valid for products intended for use on ABS classed vessels, MODUs or facilities which are in existence or under contract for construction on the date of the ABS Rules used to evaluate the Product. ABS makes no representations regarding Type Approval of the Product for use on vessels, MODUs or facilities built after the date of the ABS Rules used for this evaluation. Due to wide variety of specifications used in the products ABS has evaluated for Type Approval, it is part of our contract that; whether the standard is an ABS Rule or a non-abs Rule, the Client has full responsibility for continued compliance with the standard. Product Name: Frequency Converter Model Name(s): ACS880-x04/1604-yyyyA-3/5/7+zzzz (Category 1.a), ACS880-x4/04XT-yyyyA-3/5/7+zzzz (Category 1.b) Presented to: ABB OY DRIVES HIOMOTIE 13 PO BOX 184 FIN-00380 Finland Intended Service: Description: For use on ABS Classed Vessels and Offshore Facilities in accordance with the listed ABS Rules and International Standards. Electrical drives for ships and offshore units. Air-cooled ACS880 Drive modules (Category 1.a: ACS880-x04/1604-yyyyA-3/5/7+zzzz) and ACS880 High power single drive module packages (Category 1.b: ACS880-x4/04XT-yyyyA-3/5/7+zzzz) with built in PLC capability are suitable for controlling the speed and torque of various type of motors such as induction motors, permanent magnet motors, servo motors and ABB synchronous reluctance motors (SynRM motors). The drive can be configured in multidrive or single drive modes. The power range is from 5.2 to 5320 kw and the voltage range is from 380 to 690 V. The enclosure class of the modules is IP00 as standard (cabinets are not included in Cat. 1). ACS880 multidrive modules and module packages are designed to be built into ABB Common Cabinet or by machine builders and system integrators into customers own cabinets. Multidrive modules are used for building multidrive configurations and for building high power single drives. All supply units offer supply voltages from 380 to 690 V. Category 1.a (Drive modules): Inverter Modules: ACS880-104-0140A 5130A-3, ACS880-104-0110A 4610A-5, ACS880-104-007A3 5700A-7. Output power: 5-5320 kw, Frames: R5i...10xR8i IGBT Supply Units: ACS880-204-0210A 4620A-3, 02/16/2017 2:26:47 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 1 of 5

Tier: 5 Ratings: Service Restrictions: Comments: Notes / Documentation: ACS880-204-0210A 4150A-5, ACS880-204-0310A 5130A-7. Output power: 138-5819 kva, Frame: R6i+ALCL-05-5... 10xR8i+5xBLCL-25-7 Diode Supply Units: ACS880-304-0650A 5470A-3, ACS880-304-0650A 5470A-5, ACS880-304-0570A 4560A-7: Output power: 430-5174 kva, Frame: 2xD7T, D8T... 6xD8T Brake Modules: ACS880-604-0210 3770-3, ACS880-604-0260 4710-5, ACS880-604-0400 6500-7. Output power: 67-6180 kw, Frame: NBRA-658 6xNBRA-669, R8i 5xR8i DC/DC Converter Modules: ACS880-1604-0600A 4500A-3, ACS880-1604-0600A 4500A-5, ACS880-1604-0400A 3000A-7. Output power: 290-2721 kw, Frame: R8i 5xR8i Category 1.b (High power single drive module packages): ACS880-04XT-1190A 1610A-3, ACS880-04XT-1160A 1610A-5, ACS880-04XT-0810A 1320A-7. Output power: 599-1140 kw, Frame: 2xR10 2xR11 ACS880-04-0990A 2610A-3, ACS880-04-0990A 1980A-5, ACS880-04-0800A 2300A-7. Output power: 532-2090 kw, Frame: 2xD7T, D8T 4xD8T + 2xR8i... 4xR8i ACS880-14/34-0450A 2530A-3, ACS880-14-0420A 2270A-5, ACS880-14-0320A 2230A-7. Output power: 238-2090 kw, Frame: R8i 4xR8i + BLCL-XX-X + R8i 4xR8i Category 1.b consist of ACS880-04, ACS880-04XT and ACS880-14/34, where the same supply and inverter modules and optional brake and DC/DC converter modules are used as in the category 1.a. Category 1.a (Drive modules): Nominal Voltage: 380-690V Supply Frequency: 50/60Hz (+/-5%) IP rating: IP00 as standard Ambient Temperature: +45 55 C (Derated by 1% for every added 1 C) Output Power: Supply modules (ISU): 138-5819 kva, Frame: R6i+ALCL-05-5... 10xR8i+5xBLCL-25-7, (DSU): 430-5174 kva, Frame: 2xD7T, D8T... 6xD8T Inverter Modules (INU) : 5-5320 kw, Frame: R5i...10xR8i Brake Modules: 67-6180 kw, Frame: NBRA-658 6xNBRA-669, R8i 5xR8i DC/DC converter Modules: 290-2721 kw, Frame: R8i 5xR8i Category 1.b (High power single drive module packages): Nominal Voltage: 380-690V Supply Frequency: 50/60Hz (+/-5%) IP rating: IP00, IP20 as an option of ACS880-04XT Ambient Temperature: +45 55 C (Derated by 1% for every added 1 C) Output Power: ACS880-04 : 532-2090 kw, Frame: 2xD7T, D8T 4xD8T + 2xR8i... 4xR8i ACS880-04XT: 599-1140 kw, Frame: 2xR10 2xR11 ACS880-14/34: 238-2090 kw, Frame: R8i 4xR8i + BLCL-XX-X + R8i 4xR8i Input current and output current ratings are as per Technical Data of Product types, Category 1: 3AXD10000497338_1.B.pdf, 3AXD10000497338_2.B.pdf, 3AXD10000497338_3.B.pdf. Unit Certification is required for semiconductor converters used to control motor drives having a rated power of 100 kw(135 hp) and over intended for essential services as ABS Rules for Building and Classing Steel Vessels 2016 4-8-3/1.5, 4-8-3/5.11 and 4-8-3/8. Inspection and testing of equipment should comply with ABS Steel Vessels Rules (2016) 4-8-3/8.7. The Manufacturer has provided a declaration about the control of, or the lack of Asbestos in this product. The Frequency Drives are not intended for installation in hazardous areas. Drawing No. 3AXD10000497338_1, Revision: B List of the Air-cooled ACS880 drive modules and high power single drive module packages, Date: 09.09.2016, Pages: 1 Drawing No. 3AXD10000497338_2, Revision: B, Category 1.a: Modules, Date: 09.09.2016, Pages: 1 Drawing No. 3AXD10000497338_3, Revision: B, Category 1.b: High power single drive module, Date: 09.09.2016, Pages: 1 Drawing No. 3AXD50000010104, Revision: C, Hardware manual: ACS880-304, Date: 03.12.2015, Pages: 280 Drawing No. 3AXD50000023642, Revision: A, Hardware manual: ACS880-1604, Date: 30.06.2015, Pages: 196 Drawing No. 206452, Revision: A, Emission and immunity type test report: Date: 18.04.2012, Pages: 19 Drawing No. 217226, Revision: A, Emission and immunity type test report : Date: 13.08.2012, Pages: 16 Drawing No. 233032, Revision: A, Emission and immunity type test report : Date: 04.03.2013, Pages: 22 Drawing No. 234675-1, Revision: A, Emission type test report : Date: 28.03.2013, Pages: 12 Drawing No. 234675-2, Revision: A, Radiated emission type test report: Date: 28.03.2013, Pages: 11 Drawing No. 238152-1, Revision: A, Emission and immunity type test report: Date: 04.03.2013, Pages: 23 Drawing No. 238152-2, Revision: A, Radiated emission type test report: Date: 13.05.2013, Pages: 11 Drawing No. 267928-1, Revision: A, EMC type Test report: Date: 03.05.2012, Pages: 17 02/16/2017 2:26:47 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 2 of 5

Drawing No. 267928-2, Revision: A, EMC type Test report: Date: 03.05.2012, Pages: 15 Drawing No. 269768-1, Revision: A, Safety requirement Test report: Date: 17.12.2012, Pages: 39 Drawing No. 269768-1, Att.1, Revision: A, Safety requirement Test report attachment: Date: 17.12.2012, Pages: 7 Drawing No. 269768-1, Att.2, Revision: A, Safety requirement Test report attachment: Date: 17.12.2012, Pages: 15 Drawing No. 270905-1a, Revision: A, Safety requirement Test report: Date: 04.12.2013, Pages: 15 Drawing No. 270905-1a A1, Revision: A, Safety requirement Test report amendment: Date: 04.12.2013, Pages: 15 Drawing No. 270905-1a, Att.1, Revision: A, Safety requirement Test report attachment: Date: 17.12.2013, Pages: 4 Drawing No. 270905-1a, Att.2, Revision: A, Safety requirement Test report attachment: Date: 17.12.2013, Pages: 6 Drawing No. 270905-1b, Revision: A, Safety requirement Test report: Date: 19.12.2013, Pages: 42 Drawing No. 270905-1b, Att.1, Revision: A, Safety requirement Test report attachment: Date: 19.12.2013, Pages: 9 Drawing No. 270905-1b, Att.2, Revision: A, Safety requirement Test report attachment: Date: 19.12.2013, Pages: 18 Drawing No. 273826, Revision: A, Vibration type Test report: Date: 27.09.2013, Pages: 15 Drawing No. 273886D, Revision: A, Vibration type Test report: Date: 13.12.2013, Pages: 11 Drawing No. 278187-2, Revision: A, Safety requirement Test report: Date: 09.10.2015, Pages: 47 Drawing No. 3AUA0000085967, Revision: P, Firmware manual: ACS880, Date: 27.06.2016, Pages: 570 Drawing No. 3AUA0000104271, Revision: E, Hardware manual: ACS880-104, Date: 14.07.2014, Pages: 364 Drawing No. 3AUA0000106244, Revision: B, Hardware manual: ACS880-604, 1-phase, Date: 05.12.2013, Pages: 76 Drawing No. 3AUA0000131525, Revision: D, Hardware manual: ACS880-204, Date: 19.05.2015, Pages: 370 Drawing No. 3AUA0000131562, Revision: D, Firmware manual: ACS880 IGBT supply, Date: 01.09.2015, Pages: 224 Drawing No. 3AXD10000081363, Revision: A, Electrical safety type test report, Date: 08.06.2012, Pages: 8 Drawing No. 3AXD10000081404, Revision: A, Electrical safety type test report, Date: 08.06.2012, Pages: 8 Drawing No. 3AXD10000081409, Revision: B, Temperature rise test report, Date: 13.08.2012, Pages: 39 Drawing No. 3AXD10000088539, Revision: D, Temperature rise and abnormal operation type test report, Date: 15.12.2012, Pages: 47 Drawing No. 3AXD10000088704, Revision: A, Capacitor discharge type test report, Date: 11.10.2012, Pages: 9 Drawing No. 3AXD10000089018, Revision: C, EMC type test report, Date: 19.09.2012, Pages: 11 Drawing No. 3AXD10000091636, Revision: B, Electrical safety type test report, Date: 18.10.2012, Pages: 11 Drawing No. 3AXD10000124037, Revision: A, Temperature rise type test report, Date: 15.01.2013, Pages: 26 Drawing No. 3AXD10000240310, Revision: B, Electrical safety type test report, Date: 14.05.2013, Pages: 10 Drawing No. 3AXD10000240312, Revision: B, Temperature rise and abnormal operation type test report, Date: 28.04.2013, Pages: 25 Drawing No. 3AXD10000241184, Revision: A, Abnormal operation and protections type test report, Date: 28.04.2013, Pages: 17 Drawing No. 3AXD10000241633, Revision: C, Temperature rise and abnormal operation type test report, Date: 18.09.2013, Pages: 27 Drawing No. 3AXD10000241634, Revision: A, Electrical safety type test report, Date: 02.05.2013, Pages: 10 Drawing No. 3AXD10000241635, Revision: B, Temperature rise and abnormal operation type test report, Date: 16.04.2013, Pages: 30 Drawing No. 3AXD10000242637, Revision: C, Temperature rise and abnormal operation type test report, Date: 26.03.2015, Pages: 46 Drawing No. 3AXD10000244213, 10.06.2013, Pages: 33 Drawing No. 3AXD10000246796, Revision: A, Efficiency and harmonic distortion type test report, Date: 17.06.2013, Pages: 11 Drawing No. 3AXD10000251640, Revision: A, Temperature rise and abnormal operation type test report, Date: 10.07.2013, Pages: 31 Drawing No. 3AXD10000251641, 01.07.2013, Pages: 25 Drawing No. 3AXD10000252249, Revision: B, Temperature rise and abnormal operation type test report, Date: 10.07.2013, Pages: 17 Drawing No. 3AXD10000290757, Revision: B, Temperature rise and abnormal operation type test report, Date: 14.11.2013, Pages: 23 Drawing No. 3AXD10000290758, Revision: B, Temperature rise and abnormal operation type test report, Date: 01.10.2013, Pages: 24 Drawing No. 3AXD10000290762, Revision: A, Electrical safety type test report, Date: 07.11.2013, Pages: 8 Drawing No. 3AXD10000311720, Revision: B, Environmental type test report, Date: 10.10.2013, Pages: 8 Drawing No. 3AXD10000320896, Revision: B, Temperature rise and abnormal operation type test report, Date: 26.03.2014, Pages: 32 Drawing No. 02/16/2017 2:26:47 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 3 of 5

Term of Validity: 3AXD10000320897, Revision: A, Electrical safety type test report, Date: 17.04.2014, Pages: 8 Drawing No. 3AXD10000320898, Revision: A, Electrical safety type test report, Date: 17.04.2014, Pages: 8 Drawing No. 3AXD10000333046, Revision: A, Temperature rise and abnormal operation type test report, Date: 22.05.2014, Pages: 36 Drawing No. 3AXD10000333047, 03.06.2014, Pages: 33 Drawing No. 3AXD10000353319, Revision: B, Environmental type test report, Date: 10.01.2014, Pages: 8 Drawing No. 3AXD10000371670, Revision: A, Environmental type test report, Date: 07.12.2014, Pages: 10 Drawing No. 3AXD10000509983, Revision: A, Marine Type test requirements, Date: 02.06.2016, Pages: 15 Drawing No. 3AXD50000022033, Revision: B, Hardware manual: ACS880-604, 3-phase, Date: 08.12.2015, Pages: 128 Drawing No. 3AXD50000025169, Revision: C, Hardware manual: ACS880-04XT, Date: 13.05.2016, Pages: 244 Drawing No. 3AXD50000037752, Revision: B,ACS880 Marine Supplement (Cat. 1), Date: 09.09.2016, Pages: 50 Drawing No. ISO9001 certificate, Estonia by DNV, Date: 15.12.2015, Pages: 3 Drawing No. 3AUA0000115038, ACS880, Revision: H, ACS880_drive_modules_cataloge, Date: 10.12.2015, Pages: 60 Drawing No. Abb-9_14_20140307095153. ISO9001 certificate, Helsinki by BV, Date: 06.03.2014, Pages: 3, Drawing No. General information, Revision: A, Date: 03.06.2016, Pages: 2 Drawing No. List of documentation_abs.pdf, Revision: A, Date: 21.07.2016, Pages: 1 Drawing No. 3AXD10000569615, Revision: A, List of type tests reports, Date: 21.07.2016, Pages: 3 Drawing No. VTT-S-08265-12, Revision: A, Vibration type test report, Date: 26.09.2012, Pages: 15 Drawing No. VTT-S-08388-12, Revision: A, Damp heat type test report, Date: 04.12.2012, Pages: 4 Drawing No. 3AXD10000415632, Revision: A, Date: 26.03.2015, Pages: 12 Drawing No. 252375. Revision: A, Date: 20.01.2014, Pages: 8 Drawing No. 3AUA0000102324, Revision: A, Electrical planning instructions, Date: 23.04.2012, Pages: 38 Drawing No. VTT-S 01320-13, Revision: A, Environmental type test report, Date: 15.02.2013, Pages: 6 Drawing No. 3AXD10000367645, Revision: A, Low temperature test, Date: 16.09.2014, Pages: 8 Drawing No. 3AXD10000321226, Revision: A, Efficiency and harmonic distortions test report, Date: 15.04.2014, Pages: 12 Drawing No. 3AXD10000335564., Revision: B, Efficiency and harmonic distortions test report, Date: 28.04.2014, Pages: 10 Drawing No. 239999-2, Revision: A, Emission tests report, Date: 30.06.2013, Pages: 11 Drawing No. 238150-2, Revision: A, Emission and immunity test report,, Date: 16.06.2013, Pages: 15 Drawing No. 276203-2, Revision: A, Emission and immunity test report, Date: 02.04.2013, Pages: 15 This Product Design Assessment (PDA) Certificate 16-LD1545916-1-PDA, dated 05/Jan/2017 remains valid until 04/Jan/2022 or until the Rules or specifications used in the assessment are revised (whichever occurs first). This PDA is intended for a product to be installed on an ABS classed vessel, MODU or facility which is in existence or under contract for construction on the date of the ABS Rules or specifications used to evaluate the Product. Use of the Product on an ABS classed vessel, MODU or facility which is contracted after the validity date of the ABS Rules and specifications used to evaluate the Product, will require re-evaluation of the PDA. Use of the Product for non ABS classed vessels, MODUs or facilities is to be to an agreement between the manufacturer and intended client. ABS Rules: - Steel Vessel Rules (2016): 1-1-4/7.7, 1-1-A3&A4; 4-1-1/7.15, 4-8-3/5.11, 4-8-3/8, 4-9-8/3, 4-9-8/7, 4-9-8/13, 4-9-8 Table 1 and Table 2 - Steel Vessels Under 90 Meters (295 Feet) in Length (2016): 1-1-4/7.7, 1-1-A3&A4; 4-1-1/37, 4-6-4/10, 4-7-2 Table 1; - Facilities on Offshore Installations (2016): 1-1-4/9.7, 1-1-A2&A3; - Offshore Support Vessels (2016): 1-1-4/7.7, 1-1-A3&A4; 4-1-1/7.15, 4-8-3/5.11, 4-8-3/8, 4-9-8/3, 4-9-8/7, 4-9-8/13, 4-9-8 Table 1 and Table 2 - Mobile Offshore Drilling Units (2016): 1-1-4/9.7, 1-1-A2&A3, 6-1-1/9, 6-1-1/13; 4.3.1/11, 4.3.1/15, 6-1-7/12, 6-1-7/13.5 - Steel Vessels for Service on Rivers and Intracoastal Waterways (2016): 1-1-4/7.7, 1-1-A3&A4; 4-1-1/21, 4-5-4/10 - High Speed Crafts (2016): 1-1-4/11.9, 1-1-A2&A3; 4-1-1/37, 4-6-4/10, 4-7-9/3, 4-7-9/7, 4-7-9/15, 4-7-9 Table 9 and Table 10 - Steel Barge Rules (2016): 1-1-4/7.9, 1-1-A3&A4; 4-1-3/5 National Standards: International Standards: IEC 61800-5-1 Ed2.0:2007, IEC 60533 Ed. 3.0:2015, IEC 61800-3 Ed.2.0: 2004 + A1 (2011), IEC 60068-2-6 Ed.7.0:2007,EN 61800-3: (2004) + A1 (2011), EN60068-30:2005, ISO 9001:2008, ISO14001:2004 02/16/2017 2:26:47 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 4 of 5

Government Authority: EUMED: Others: Model Certificate Model Certificate No Issue Date Expiry Date PDA 16-LD1545916-1-PDA 11-JAN-2017 04-JAN-2022 ABS Programs ABS has used due diligence in the preparation of this certificate and it represents the information on the product in the ABS Records as of the date and time the certificate was printed. Type Approval requires Drawing Assessment, Prototype Testing and assessment of the manufacturer's quality assurance and quality control arrangements. Limited circumstances may allow only Prototype Testing to satisfy Type Approval. The approvals of Drawings and Products remain valid as long as the ABS Rule, to which they were assessed, remains valid. ABS cautions manufacturers to review and maintain compliance with all other specifications to which the product may have been assessed. Further, unless it is specifically indicated in the description of the product; Type Approval does not necessarily waive witnessed inspection or survey procedures (where otherwise required) for products to be used in a vessel, MODU or facility intended to be ABS classed or that is presently in class with ABS. Questions regarding the validity of ABS Rules or the need for supplemental testing or inspection of such products should, in all cases, be addressed to ABS. 02/16/2017 2:26:47 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 5 of 5