Boiler Technical Specifications (2013)

Similar documents
Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic

Heating with wood chips

english GUNTAMATIC BIoMAss BoIler HeATING range

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Easyfire Standalone biomass pellet boiler

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Combined boiler. for solid fuel and pellets

Forward-looking and energy effi cient Biomass heating

2x58 MW Coal Fired Power Plant at Mauritius

PUSHING THE LIMITS OF WHAT IS POSSIBLE

Technical Data Manual. Vitoflex 300-RF Wood-fired Boiler Vitoflex 300-RF 150, 220, 300, 400 and 540. for use by engineers and heating contractors

Multi-Heat. Multi-Heat Datasheet Version Tarm Biomass 4 Britton Lane Lyme, NH 03768

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA

Solid biofuel solutions

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Computer Controller. The Bio-Burner has user regulated settings as well as built-in safety features to protect you and your burner.

Rozp.UE2015/ kw kw

PELLET BURNER PV 350

Efficient CHP-plant 150 kw

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60, 80/100. Benefits at a Glance:

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

User friendly, compact, economical and safe

Heating with wood chips & pellets

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

Williams & Davis Boilers

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Wood Chip and Pellet Boilers. Turbomat TM 500.

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance:

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Eco Angus Wood Pellet Boilers

Importance of a Draught Regulator

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Heating with log wood

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

HERZ ECO-Line Heating with logs or wood pellets

A totally renewable heat source

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Williams & Davis Boilers

Biomass. Biomass solid fuel boiler range

modern heating devices

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

OPERATING INSTRUCTIONS with safety features

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

Concrete Applications

FLUIDIZED BED BOILERS

A totally renewable heat source

Biomass Energy Systems

DRUM DRYERS FOR THE WOOD PELLET INDUSTRY

PVE SERIES POWER VENTER SYSTEM MANUAL

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

Boiler. Fire tube Boiler:

Log fired heating system

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

ARITERM OY. Arimatic 500. User manual

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

MANUAL. Page 1/44

Wood logs boiler with a gasication eect IGNIS KW. INSTRUCTIONS MANUAL for usage and maintenance

English. Heating with logs & wood pellets 20-40

Biomass Pellet Boilers

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

Heating with pellets kw

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

State of the Art. Exceptional Reliability

KWB CLASSICFIRE Log-wood and pellet heating system 18/28 kw

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating

EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems

Instruction manual for installation, operation and maintenance of automatic pellet burner of series GP on solid fuel hot water boiler VIADRUS U26

Owner s Manual for. PennStoker

ISO 9001 TUV CERT CE

TASKS REGARDING COMBUSTION AIR

ETA HACK VR kw The all-rounder for businesses, industry and communities

BIOMASS COMBUSTION BOILERS

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

Operating Instructions

Dear Customer, We at Northwest Mfg., Inc. would like to thank you for purchasing the

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

Revitalize Building Mechanical Systems (4619)

Pioneers of heating with biomasses

Electronic Pellet Burner Controller NPBC-V3M

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Biomass heating: a guide to small log and wood pellet systems

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Heating with wood pellets kw

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

Single stage operation oil burner

Fire Chief Wood/Coal Burning Furnaces

Transcription:

ACT Bioenergy Boiler Dimensions 0.5-0.85 Million Btu/h (150-250kW) Model CP500 CP600 CP750 CP850 Heat Output in MBtu/h (kw) 510 (150) 610 (180) 750 (220) 850 (250) Height ft (mm) 6 1 (1855) 6 1 (1855) 6 1 (1855) 6 1 (1855) Length (X) ft (mm) 5 7 (1700) 5 11 (1800) 6 4 (1930) 6 9 (2060) Width ft (mm) 8 11 (2720) 8 11 (2720) 8 11 (2720) 8 11 (2720) Toll Free: 1-877-228-2465 Page 1 of 7

ACT Bioenergy Boiler Dimensions 1.0-1.7 Million Btu/h (300-500kW) Model CP1000 CP1200 CP1350 CP1500 CP1700 Heat Output in MBtu/h (kw) 1000 (300) 1200 (350) 1360 (400) 1500 (450) 1700 (500) Height ft (mm) 6 8 (2030) 6 8 (2030) 6 8 (2030) 6 8 (2030) 6 8 (2030) Length (X) ft (mm) 6 9 (2060) 7 1 (2160) 7 6 (2285) 7 11 (2410) 8 3 (2515) Width ft (mm) 9 4 (2845) 9 4 (2845) 9 4 (2845) 9 4 (2845) 9 4 (2845) Toll Free: 1-877-228-2465 Page 2 of 7

BOILER TECHNICAL DATA Boiler Model CP500 CP600 CP750 CP850 Full load output Btu 510,000 610,000 750,000 850,000 Partial load output Btu 137,000 154,000 188,000 222,000 Combustion efficiency at full load % 80-85 80-85 80-85 80-85 Boiler class (ASME) IV IV IV IV Water Water volume gal 100 110 122 132 Diameter of the water connection in 3 3 3 3 Hydraulic-pressure drop of the boiler at the temperature fall 35 F mbar 65 73 80 87 Boiler operating temperature F 145-220 145-220 145-220 145-220 Minimum return water temperature F 140 140 140 140 Maximum operational pressure psi 30 30 30 30 Test pressure psi 60 60 60 60 Temperature of furnace F 1650 2000 Pressure of furnace in (H 2 O) - 0.12-0.12-0.12-0.12 Required pressure in the chimney in (H 2 O) - 0.08-0.08-0.08-0.08 Requirement for the forced draught Yes Yes Yes Yes High stack temperature alarm F 446 446 446 446 Exhaust temperature at full load F 280-300 280-300 280-300 280-300 Flue gas output at full load lbs/h 760 860 960 1040 Flue gas output at partial load lbs/h 200 230 260 280 Flue diameter in 9 9 9 9 Chimney diameter in 10 10 10 10 Type of chimney Fuel Moisture-resistant Maximum size in 1.25 1.25 1.25 1.25 Maximum moisture content % 30 30 30 30 Electrical installation Connection 208-230V, 60 Hz, 3-phase, Wye connection Toll Free: 1-877-228-2465 Page 3 of 7

BOILER TECHNICAL DATA Boiler Model CP1000 CP1200 CP1350 CP1500 CP1700 Full load output Btu 1,000,000 1,200,000 1,360,000 1,500,000 1,700,000 Partial load output Btu 256,000 310,000 340,000 400,000 480,000 Combustion efficiency at full load % 80-85 80-85 80-85 80-85 80-85 Boiler class (ASME) % IV IV IV IV IV Water Water volume gal 182 195 210 225 240 Diameter of the water connection 4 4 4 4 4 Hydraulic-pressure drop of the boiler at the temperature fall 35 F mbar 95 102 110 122 130 Boiler operating temperature F 145-220 145-220 145-220 145-220 145-220 Minimum return water temperature F 140 140 140 140 140 Maximum operational pressure psi 30 30 30 30 30 Test pressure psi 60 60 60 60 60 Temperature of furnace F 1650 2000 Pressure of furnace in (H 2 O) - 0.12-0.12-0.12-0.12-0.12 Required pressure in the chimney in (H 2 O) - 0.08-0.08-0.08-0.08-0.08 Requirement for the forced draught Yes Yes Yes Yes Yes High stack temperature alarm F 446 446 446 446 446 Exhaust temperature at full load F 280-300 280-300 280-300 280-300 280-300 Flue gas output at full load lbs/h 1150 1260 1370 1480 1590 Flue gas output at partial load lbs/h 310 330 360 400 420 Flue diameter in 12 12 12 12 12 Chimney diameter in 14 14 14 14 14 Type of chimney Fuel Moisture-resistant Maximum size in 1.25 1.25 1.25 1.25 1.25 Maximum moisture content % 30 30 30 30 30 Electrical installation Power connection 208-230V, 60 Hz, 3-phase, Wye connection Specifications are subject to change without notice. Toll Free: 1-877-228-2465 Page 4 of 7

ACT Bioenergy Boiler with fuel auger 1. Rotating arm to feed fuel to auger 2. Auger drive shaft 3. Main fuel bin auger 4. Main fuel bin auger channel 5. Auger drive motor 6. Flap valve to prevent burn-back 7. Ultrasonic probe to measure fuel in intermediate fuel bin 8. Intermediate fuel storage bin 9. Agitator to prevent fuel bridging 10. Burner fuel feeding auger 11. Emergency extinguishing system 12. Hot air ignition blower 13. Primary, secondary and tertiary blower motors with VFDs 14. Control panel box 15. Control panel display 16. Burner ring (primary gasification zone) 17. Rotating ash grate 18. Secondary and tertiary air introduction rings 19. Ash collection bin 20. Flap valve actuator to bypass boiler tubes during start-up 21. Double insulated heat exchanger 22. Rotating turbulators to clean boiler tubes 23. Turbulator drive motor 24. Exhaust fan with VFD Toll Free: 1-877-228-2465 Page 5 of 7

ACT Bioenergy Boiler with fuel auger 25. Grate cleaning drive arm 26. Ash removal auger 27. Primary air channel 28. Heat exchanger bypass valve 29. Turbulators 30. Cover for heat exchanger cleaning 31. Flue gas duct to cyclone 32. Combustion chamber service door 33. Combustion chamber inspection door 34. Boiler jacket/cover Toll Free: 1-877-228-2465 Page 6 of 7

Boiler Function CLEAN HEATING SOLUTIONS The boiler consists of the following key components: Toll Free: 1-877-228-2465 Page 7 of 7 Fuel Storage and Delivery System The fuel storage and delivery system conveys the fuel from the main fuel storage bin to the boiler. The ACT storage bin auger/stirrer system consists of the rotating arm (1) with the conveying auger (3) inside the auger channel (4) and the auger motor (5). A burn-back prevention flap valve controlled (6) by an actuator provides an airtight seal between the main fuel storage and the boiler system. This flap valve is only opened when fuel is feeding to the intermediate fuel storage bin. The rotating stirrer has leaf spring arms with the spindle covered by a turntable. The fuel auger delivers fuel to the intermediate storage bin (8). An ultrasonic probe (7) mounted on top of the intermediate storage bins measures the depth of fuel in the bin. When the level of fuel in the intermediate bin drops below a preset level, the flap valve (6) is opened and the auger refills the intermediate fuel bin (8). Once the intermediate bin is filled, the auger stops and the flap valve shuts. The fuel is delivered from the intermediate bin by the burner auger (10) to the burner ring (16). The sealed flap valve of burn-back protection (6) is automatically shut in the event of power failure. Below the intermediate fuel bin is the main drive motor, the motor for ash removal and the gear-drive for agitator to prevent bridging in the intermediate fuel bin (9). (Note: It is also possible to use other fuel delivery systems - such as a flex auger or pneumatic conveyor to supply fuel to the boiler to the boiler; but the compatibility of these systems must first be determined through consultation with ACT technical staff.) Combustion Chamber The combustion chamber is located at the front of the boiler. It consists of the round burner ring (16), rotating ash grate (17) and two-part collar for secondary and tertiary air (18). Due to high temperatures in the combustion chamber, all the parts are made of stainless steel. The fuel is fed from beneath and up through the center of the burner ring. The fuel is gasified at the burner ring where the primary air is supplied. The secondary and tertiary burner rings supply additional air to complete the combustion of the fuel. Next, the hot gases leave the combustion chamber through the heat exchanger bypass valve (28) which is at the top rear of the combustion chamber. The bypass valve is controlled by an actuator (20). On starting the boiler, the valve is open and the flue gases are sent directly to the stack. The bypass valve is closed once the flue gases are hot enough so that moisture in the flue gases won t condense within the heat exchanger portion of the boiler and cause corrosion. The ash from the combusted fuel falls from the edge of the rotating ash grate on two ash removal augers (26), which convey the ash into the ash collection bin (19). The combustion chamber service door (32) allow easy access to the combustion chamber if required for servicing. Heat Exchanger The rear heat exchanger portion of the boiler (21) is comprised of rows of vertical heat exchanger tubes. In the tubes there are turbulators (22, 29), which enhance heat transfer by creating turbulent air flows in the tubes. The turbulators are connected by a chain and motor drive (23). The turbulators rotate to scrape ash deposits from the inside of the heat exchanger tubes. Heat losses from the boiler are minimized by two layers of insulation covered by the steel boiler jacket (34). Hot gases exit the heat exchanger through the flue transition duct (31). The exhaust fan (24) is typically mounted on the top of a dust collection cyclone (not shown). There is a door (30) on either side of the heat exchanger for removal of ash from underneath the turbulators and access door(s) to remove ash from the flue. Control Panel The control panel modulates the primary, secondary and tertiary combustion air fans (13), and the combustion chamber pressure sensor, which senses the negative pressure in the combustion chamber. A consistent negative pressure is achieved by the variable frequency drive that adjusts the exhaust fan speed to maintain negative 30 Pascals to control draft and prevents fugitive exhaust emissions from the boiler. The hot-air ignition blower (12) enables automatic fuel ignition. The emergency fire extinguisher (11) measures the temperature for the fuel feeding auger channel and releases water into the auger channel if the temperature exceeds 200ºF (90ºC). The boiler control panel and control panel display (14, 15) manage the boiler operations and fuel feed rates and allow the operator to adjust boiler control parameters. The control system constantly monitors the temperature and oxygen levels of the exhaust gases and adjusts speed of the three fans to achieve optimal combustion.