White Paper. Optical Installation and Maintenance

Similar documents
Product Introduction. CMA5000a OTDR

CMA5000 OTDR Module Series

Product Brochure MT9090A. Network Master Series. MU909011A Drop Cable Fault Locator Modules 780nm and 1550nm OTDR for Single Mode Fiber

MT9080 Series. ACCESS Master TM. 1.31/1.55/1.65 µm (SM)

A truly revolutionary OTDR

Advanced Test Equipment Rentals ATEC (2832) Product Brochure. CMA5000a. Multi-layer Network Test Platform

MW9070B Optical Time Domain Reflectometer

Advanced Test Equipment Rentals ATEC (2832)

MT9083 Series. MT9083A/B/C ACCESS Master. 850/1300 nm OTDR for Multimode Fiber 780/1310/1383/1490/1550/1625/1650 nm OTDR for Single Mode Fiber

Product Brochure MT9083A. ACCESS Master. 850/1300 nm OTDR for MMF 780/1310/1383/1490/1550/1625/1650 nm OTDR for SMF

Network Master Series

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

Fibre Characterisation and FTTx New challenges

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Yokogawa Meters & Instruments Releases AQ1200E, AQ1205A, AQ1205E, and AQ1205F OTDR Multi Field Testers

Network Master Series

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Network Master Series

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Return loss measurement of fiber optic components

FLX380-30x FlexTester OTDR

Network Master Series

BA4000 Series Curtain Machine

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

M700-Series Multifunction OTDR

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Crushers from Metso Recycling. Metso EtaCrush

MW9060A Optical Time Domain Reflectometer

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

BUILD the clinic you ve always imagined.

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

ACCESS Master MT9085 Series. Product Introduction

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

MTL1000 range of signal conditioners. For reliable, high quality process communications

Benefits of Enhanced Event Analysis in. Mark Miller

Dräger P4000 Pressure and Leak Testing

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

FLX380-30x FlexTester3 OTDR

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Network Master Series

Shredders from Metso. Lindemann Eta Shred

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Network Master Series

Field Test Procedure for Optical Fibre Link Measurements

Acterna MTS 5000 e Series OTDR and Loss Test modules

Correlation-based OTDR for in-service monitoring of 64-split TDM PON

MT9085 Series ACCESS Master

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

FieldLink Cable solutions for Automation & Drives

Hands-On CAT 5/6 & Fiber Optic Installer

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

M700-Series OTDRs. or (800) , (603)

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

SMALL SCALE SOLUTIONS

AX51 with Munters Drive

MTTplus Modular Test Platform

BA2702-P Linear Actuator

OZ Optics Limited. Fiber Optic Attenuators. June 2018

OTP6123 Series. Handheld OTDR Test Set.

Noyes OFL 250B Specs Provided by

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Product Information. Optical fibre water sensor. - Early warning system for ensuring maximum availability of optical transmission routes

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

Information about the product Lexan FR60, FR63, FR65, FR66

AQ7275 OTDR Optical Time Domain Reflectometer

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Securing optical network physical layer with Fiber Monitoring and Management Vratislav Blažek Regional Sales Manager

The Rise of Tier 2 Testing

VePAL FX300 Fiber Expert OTDR

Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

Sterlite Tech Academy Creating Smarter Network Professionals

RC Series Discharge Cones

Datasheet Palm OTDR. Product Summaries

Accuracy counts! Sensors with analog output

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

Computerised Analysis of OFM in Communication Theory

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

Installation Instructions

Fiber Optics for Todays Industry Applications

AQ7275OTDR Optical Time Domain Refl ectometer

NX8663JB-BC. Data Sheet DESCRIPTION FEATURES R08DS0063EJ0100 LASER DIODE. Rev.1.00

AV6416 OTDR. Product Overview: Main Features:

FTS510 Series. Handheld OTDR Test Set.

Basic Professional Fiber Optic Installation

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01

AQ7275 OTDR Optical Time Domain Reflectometer

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Transcription:

Doc 4:Layout 1 04/09/2009 10:06 Page 1 White Paper Optical Installation and Maintenance

Maintenance of Access Network Optical Fibers Troubleshooting PON Drop Cable Faults using Short-Wavelength OTDR Method 1. Introduction The huge growth in the number of subscribers with FTTH installations requires different maintenance methods than used previously. This article explains maintenance of the last one mile and explains some concrete measurement solutions. 2. Current Status of Access Networks Always-on Internet connections coupled with widespread adoption of applications such as IPTV, VoIP, etc., is driving further increases in access network transmission bandwidth with accelerating transition from conventional metallic cable to FTTH. Figure 1 shows the change in broadband access network subscribers in Japan. March 2006 was the turning point when the number of the DSL subscribers started decreasing, while on the other hand, the number of FTTH s is steadily increasing. According to NTT, the conversion of core networks to optical technology is already completed, and optical fiber networks can cover more than 85% of subscribers. Currently, work is progressing nationwide to run optical fiber over the so-called last mile to subscribers households with the aim of reaching 30 million FTTH subscribers by 2010. Figure 1: Trend in Broadband Access Subscribers A Passive Optical Network (PON) system is the most efficient method for providing broadband transmissions over an access network. In this method, an Optical Line Terminal (OLT) in the Central Office (CO) and an Optical Network Unit (ONU) in the subscriber s house provide cost-effective FTTH by allowing use of optical couplers to split 1 fiber into N connections. An example of the system structure is shown in Figure 2. 6 Figure 2: PON System Structure

3. Fiber Construction Targeting Start of FTTH Services Construction of the trunk cable shown in the Figure 2 has been completed to cover 85% of households currently. All that remains to do is to run an optical fiber from the splitter (coupler) in the closure to the subscriber s household when service is requested, creating a direct FTTH connection between the Central Office and the subscriber s household using optical fiber. The optical fiber running between this closure and the subscriber s household is called the drop cable or drop optical fiber and can be up to 1.6 km long. In metropolitan households, the drop cable is often less than 500 m long. Installation of the drop cable first requires confirmation of the optical level at the subscriber s household followed by throughput measurement at the ONU. 4. Various Drop Cable Faults The optical fibers are run from the underground closure up the utility pole, strung from an aerial wire, split by the coupler, and finally terminate in each ONU in the subscribers households. Relatively more faults (fiber breaks and large loss) occur in this section of fiber between the coupler and the ONU than in the trunk fiber. The three main causes of these faults are listed below: (1) Natural disasters - Since the fiber is strung from utility poles, it is subject to repeated stress from typhoons, heavy rain, etc., as well as aging changes, which cause breaks and loss. (2) Animal damage by birds, insects, etc. - Attacks by animals, like squirrels, rats, crows, etc., cause damage and fiber breaks. In west Japan, there have been many reports of damage caused by cicadas laying eggs in cables. Figure 3: issue of maintenance of PON systems in Japan - types of insect damage This data is quoted from Techniques for FTTH Produced by Mr. Koji Arakawa with NTT Advance Technology Ltd. (3) Excessive fiber bending in subscriber household - Sometimes, people rearranging their furniture or moving the ONU can bend the fiber excessively, causing a break or high loss. The most important issue for service engineers is how to quickly and efficiently troubleshoot drop cable faults caused by these types of problems. 5. Drop Cable Maintenance When a fault occurs in a subscriber s FTTH service, if other subscribers sharing the OLT are not experiencing the same fault, the problem is either in the drop cable between the coupler and the ONU, or in the subscriber s home network including the ONU. In most cases of home network faults, the problem is resolved by toggling the ONU, router and terminal power OFF/ON to restart the session. This section explains maintenance of the drop cable from the splitter to the ONU. (1) Locating Fault When the ONU is not receiving an optical signal, the optical signal level is checked with a power meter after disconnecting the optical fiber from the ONU. 7

(Case 1) - When the optical signal level is confirmed to be within specification by the optical power meter, the problem is either in the ONU receiver or at the connection point between the ONU and fiber. The operation is rechecked after cleaning the connector and if this does not solve the problem, the ONU is swapped out and resumption of normal operation checked again. (Case 2) - When the optical signal level is not confirmed as being within specification by the optical power meter or when the optical level is lower than the specification, there is a high chance that there is either a break or damage somewhere in the drop cable. This requires locating the fault point and either repairing it by splicing the fiber or running a new drop cable. (2) Identifying Break in Drop Cable Fiber faults are located using an Optical Time Domain Reflect Meter (OTDR). However, testing using an OTDR requires inputting a strong optical pulse into the fiber under test and measurement requires extreme care so as not to disrupt other in-service signals. Conventionally, when a break occurs in a trunk optical fiber, it is not necessary to consider the impact of the pulse test on the service because the fiber is out of service. However, maintenance of a PON drop cable requires care because the rest of the network other than the faulty drop cable is still in-service. If a test is run in the in-service condition using an OTDR at the subscriber s side using the same procedure as used for trunk lines, the in-service optical signals and the OTDR test optical pulse signals will interfere with each other on the line and services may stop. To prevent this interference, it is necessary to isolate the drop cable under test from the rest of the network so that the test pulses from the OTDR do not have any effect on the OLT or the ONUs of other subscribers. When the drop cable and splitter (coupler) are connected using a connector, they can be disconnected, but this is not easy because the connections are usually high up utility poles and wires. When this connection is made by fiber splice, the disconnection work is even more difficult. There is a technique for isolating the drop cable by bending the fiber but it is not easy and requires a high degree of skill on the part of the service engineer. In addition there is also a serious risk of causing more damage by bending the fiber. The solution to these problems is to use a short-wavelength OTDR with test pulses at a wavelength of 780 nm. PON systems use UP signals with a wavelength of 1310 nm and DOWN signals with wavelengths of 1490 and 1550 nm, and the receivers (O/E converters) in the OLT and ONU naturally use these long wavelengths. Figure 4 shows the wavelength dependence of the photodiode sensitivity (quantum effect) for these long-wavelength-band receivers. Figure 4 the wavelength dependence of the photodiode sensitivity As we can see from this graph, optical receivers using photodiodes with these types of characteristics have absolutely no sensitivity to light at 780 nm. As a result, testing at the subscriber side with an OTDR using optical signals at 780 nm has no effect at all on the in-service conditions and allows the service engineer locate the fault and recover the service quickly and easily. Figure 5 shows a drop cable (2.2 km) measurement example using a 780-nm OTDR. Since the dynamic range at 780 nm is 8 db, the 2.2-km fiber end can be observed with sufficient S/N ratio. With this performance, faults in a 2-km or shorter drop cable can be pinpointed with excellent accuracy. 8

(3) Loss Measurement at Drop Cable Connectors Figure 5. Measurement Example using 780-nm OTDR When there is a problem at the ONU fiber connector, sometimes the optical signal loss becomes very large and service stops. At OTDR testing, when the loss at the connector connected to the OTDR is large, it can be difficult to measure the loss quantitatively. As a result, loss measurement for this connector requires inserting a dummy fiber that is sufficiently longer than the OTDR attenuation dead zone (backscatter dead zone). Since the dead zone characteristics depend on the equipment, it is better if this dummy fiber is built into the measuring instrument. Figure 6 shows an example of connector loss measurement using a 780-nm OTDR with built-in dummy fiber. Figure 6. Example of ONU Connector Loss Measurement The blue part is the trace of the dummy fiber built-into the OTDR; the red part is the trace of the fiber under test. A = 0.0 at the connector indicates that it has no measurable loss. (Note) Attenuation Dead Zone The OTDR receiver can be saturated by large reflection from connection points, such as connectors. The attenuation dead zone is the time from when the receiver recovers from this saturation condition until the fiber loss can be measured with good accuracy converted to distance. It can also be called the backscatter dead zone, meaning the distance until the reflection due to backscattering can be measured. (4) Locating LAN Fault To locate LAN faults caused by excessive bending of the fiber, it is necessary to use an OTDR with an extremely short dead zone. Measuring the loss of the connector at the ONU requires insertion of a dummy fiber as previously described, but since there is always reflection at this location, there is a section of fiber immediately after this connec- 9

tion that cannot be measured. This is known as the OTDR event dead zone and is a basic performance parameter for OTDRs; it is very dependent on the pulse width and receiver performance. Figure 7 shows an example of measurement using a 780-nm OTDR with an event dead doze of less than 1 m. Splice connections immediately after the connector to the ONU can be clearly detected. There is a method of searching for indoor faults by eye using a visible laser light source without using an OTDR. When a visible laser light is input to a drop cable, the fault point where the light is leaking can be seen by eye. Using a flashing red laser light increases the fault visibility further. (5) Locating Macrobending Faults Although the 780-nm OTDR has the advantages of supporting in-service fault location, it has the disadvantage of not being able to easily detect macrobend faults due to the small bending loss. The fiber bending loss depends directly on the wavelength, becoming larger at longer wavelengths. Although a 1310-nm signal can be transmitted without macrobending loss problems, a 1550-nm signal cannot. Detection of macrobending is best performed using an OTDR with a 1650-nm optical signal but as previously described, it is necessary to take precautions against impacting in-service signals. In addition, recently, Figure 7. Example of Measurement using 780-nm OTDR with so-called R15 fiber with strong bending tolerance has Max. Event Dead Zone of 1 m been developed for use as drop cables, reducing the necessity for macrobending detection. The characteristics of this R15 fiber do not change even at a bend radius of 15 mm, supporting lossless fiber installations. Figure 8 shows the loss versus wavelength results for various bend radii. 6. Summary Figure 8. Relationship between Fiber Radius of Curvature and Loss Access network maintenance is becoming increasingly important with the rapid spread of broadband services. For carriers to win in this extremely price competitive market, it is essential for them to cut access network maintenance costs and time. The 780-nm OTDR is the ideal solution for maintaining in-service PON systems because it enables less-experienced service engineers to solve problems easily and quickly and is expected to play an increasingly important role in future markets. 10

Specifications are subject to change without notice. Anritsu Corporation 5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan Phone: +81-46-223-1111 Fax: +81-46-296-1238 U.S.A. Anritsu Company 1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A. Toll Free: 1-800-267-4878 Phone: +1-972-644-1777 Fax: +1-972-671-1877 Canada Anritsu Electronics Ltd. 700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006 Brazil Anritsu Eletrônica Ltda. Praca Amadeu Amaral, 27-1 Andar 01327-010-Paraiso-São Paulo-Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940 Mexico Anritsu Company, S.A. de C.V. Av. Ejército Nacional No. 579 Piso 9, Col. Granada 11520 México, D.F., México Phone: +52-55-1101-2370 Fax: +52-55-5254-3147 U.K. 200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K. Phone: +44-1582-433200 Fax: +44-1582-731303 France Anritsu S.A. 16/18 avenue du Québec-SILIC 720 91961 COURTABOEUF CEDEX, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65 Germany Anritsu GmbH Nemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55 Italy Anritsu S.p.A. Via Elio Vittorini 129, 00144 Roma, Italy Phone: +39-6-509-9711 Fax: +39-6-502-2425 Sweden Anritsu AB Borgafjordsgatan 13, 164 40 KISTA, Sweden Phone: +46-8-534-707-00 Fax: +46-8-534-707-30 Finland Anritsu AB Teknobulevardi 3-5, FI-01530 VANTAA, Finland Phone: +358-20-741-8100 Fax: +358-20-741-8111 Denmark Anritsu A/S Kirkebjerg Allé 90, DK-2605 Brøndby, Denmark Phone: +45-72112200 Fax: +45-72112210 Spain Oficina de Representación en España Edificio Veganova Avda de la Vega, n 1 (edf 8, pl 1, of 8) 28108 ALCOBENDAS - Madrid, Spain Phone: +34-914905761 Fax: +34-914905762 Russia Representation Office in Russia Tverskaya str. 16/2, bld. 1, 7th floor. Russia, 125009, Moscow Phone: +7-495-363-1694 Fax: +7-495-935-8962 United Arab Emirates Dubai Liaison Office P O Box 500413 - Dubai Internet City Al Thuraya Building, Tower 1, Suit 701, 7th Floor Dubai, United Arab Emirates Phone: +971-4-3670352 Fax: +971-4-3688460 Singapore Anritsu Pte. Ltd. 60 Alexandra Terrace, #02-08, The Comtech (Lobby A) Singapore 118502 Phone: +65-6282-2400 Fax: +65-6282-2533 India Anritsu Pte. Ltd. India Branch Office 3rd Floor, Shri Lakshminarayan Niwas, #2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, India Phone: +91-80-4058-1300 Fax: +91-80-4058-1301 P.R. China (Hong Kong) Anritsu Company Ltd. Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong Phone: +852-2301-4980 Fax: +852-2301-3545 P.R. China (Beijing) Anritsu Company Ltd. Beijing Representative Office Room 2008, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 100004, P.R. China Phone: +86-10-6590-9230 Fax: +86-10-6590-9235 Korea Anritsu Corporation, Ltd. 8F Hyunjuk Building, 832-41, Yeoksam Dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553-6603 Fax: +82-2-553-6604 Australia Anritsu Pty. Ltd. Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255 Taiwan Anritsu Company Inc. 7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817 Please Contact: Printed on Recycled Paper 081225 0909