High Efficient Heating Solution

Similar documents
HEATING HEA TING

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

NATURAL HEATING MACHINE

and sanitary hot water Catalogue 2009

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Aperçu de la gamme Therma V

Our. What is LG THERMA V? ENERGY EFFICIENT APPLICATION VARIOUS APPLICATION

Do you want a versatile solution

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Samsung Eco Heating System

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

(Non-Inverter & Inverter) R410A

Advance Split

THE HEAT PUMP CHOICE OF PROFESSIONALS

Air to water Heat Pump System

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

EHS. EHS (Mono, LT, 50Hz)

WHY A MHI HEAT PUMP?

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Air to water Heat Pump System

LG Electronics AE Company, Commercial Air Conditioning

EVI Scroll Air To Water Heat Pumps

LG Electronics AE Company, Commercial Air Conditioning

The Future of Central Heating Today. Air source heat pump systems

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Sweden s leading air source heat pump

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

HIWARM COMPACT kw

HT V2 HT Split

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

S-Therm Air to Water Heat Pumps

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

2009 Panasonic Marketing Europe GmbH / All rights reserved

AQUAHEAT ADVANCE SPLIT

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Air Conditioning System

V016-EN-01 AIR TO WATER HEAT PUMPS 2016 HEART OF YOUR HOME

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

DC Inverter Smart VRF Products(R410A)

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Daikin air conditioners for your home

LG Commercial Air Conditioners. Wide Range Free Combination with Various Indoor Types 24/7.0 18/5.3 12/3.5 9/2.6 7/2.1 5/

V017-EN-01 AIR TO WATER HEAT PUMPS HEART OF YOUR HOME

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-02A(5BPU0-01A)

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Starting current with soft starter Fuse protection

High temperature air-to-water heat pumps

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Mitsubishi Electric's

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Daikin Altherma Low Temperature monobloc heat pump

50A KP 70A KP 90A KP 120A KP 150A KP 210A

PRODUCT DATA SHEETS HEAT PUMPS

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Split Type System. Air to Water Heat Pump

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)

Product Line Introduction. Karl Zhang Technical support engineer

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

UK arotherm Schematics and installation guide

V018-EN-02 AIR TO WATER HEAT PUMPS 2019 HEART OF YOUR HOME

LG VRF Systems. Air Conditioning Technologies

Daikin Altherma Low Temperature monobloc heat pump

Heat Pump Water Heater Commercial Leaflet 2012

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LZT High efficiency air to water heat pumps with E.V.I. compressors

Saving energy comes naturally to us.

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

SAVING THE PLANET AND YOUR POCKET

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Water and ground source heat pumps 61WG kw. Heating

PAC BT LOW TEMPERATURE HEAT PUMP

Efficient heating that won t cost the earth

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

PRODUCT RANGE HEAT PUMPS 2012

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

NUOS RANGE HEAT PUMP WATER HEATERS

Transcription:

ir-to-water Heat Pump High Efficient Heating Solution LG Electronics E Company, Commercial ir Conditioning Two IFC, 10 Gukjegeumyung-ro, Yeongdeungpo-gu, Seoul, 150-945, Korea. www.lg.com www.lgeaircon.com Copyright 014 LG Electronics. ll rights reserved. Distributed by

FOCUS ON ENERGY & ENVIRONMENT Focus on Energy & Environment Continuous Challenges The EU has set a target to cut emissions by 40% by 030 with 7% of energy being produced by renewable sources. Plans are in place to move each country to a more energy efficient, low-carbon economy to help meet this target. The UK s example - The UK Green Deal and the CRC Energy Efficiency Scheme to assist investing in low carbon technologies - ll properties (homes, commercial and public buildings) must have an Energy Performance Certificate (EPC) when sold, built or rented. - Larger public buildings over 500m² must display a Display Energy Certificate (DEC). The Renewable Heat Incentive (RHI) The RHI is the UK Government financial incentive scheme to encourage a switch from fossil fuel heating systems to renewable heating systems. Renewable heat is defined as the heat generated minus the electrical input. (If the output is 10 kw, and the input is 3 kw, then the renewable output is 7kW, or 7kWh every hour of operation.) - The domestic RHI for ir to Water Heat Pump (launched 9 pril 014) : RHI pays 7.3p/kWhr to homeonwers, private landlords, social landlords and self-builders. - Non-domestic RHI for ir to Water Heat Pump (launched 8 May 014) : RHI pays.5p/kwhr to industry, businesses and public sector organization. In order to claim for the RHI you will need a Green Deal ssessment and a MCS approved product and an MCS approved installer. Microgeneration Certified Scheme (MCS) European Standards LG THERM V has adopted for the energy certification to correspond with the market demand for the each country. THERM V has been validated for its reliability and efficiency by acquiring these certifications under strict conditions.. Certification benefit - MCS (UK) : RHI (Renewable Heat Incentive) tariff 7.3 Pence / kwh for 7 years MCS - NF PC (France) : promoted in the context of Thermal Regulation RT 01. CERTIFICTE BB 0096 Tax Refund (15%~5% of product cost) MCS (UK) - EUROVENT (EU) : Model registration at the EUROVENT website LG Energy Lab NF PC (France) LG THERM V has passed through the severe testing condition at the Energy Lab which is located in northern France. It can prove LG THERM V is designed to make sure the steady performance and reliability under European winter condition. France Wargnies-Le-Petit Paris test EUROVENT(EU) Korea Before applying - Green Deal ssessment must be carried out. - Install loft or cavity wall insulation if it s recommended in the Green Deal dvice Report. - Get an updated EPC (Energy Performance Certificate) to verify you ve installed the loft or cavity wall insulation. How to apply The end-user must complete an online application form and supply - MCS certificate (or equivalent) number This is at the top of the certificate and looks like : MCS 0134567- - EPC number This is at the top of your certificate and looks like : 1345-5678-901-3456 - Green Deal dvice Report number This is at the top of your report and looks like : 1345-6789-013-4567 Save money and pay-back - Domestic RHI Claimable for 7 years (this can be backdated) Tariff 7.3pkWhr - Non-domestic RHI Claimable for 0 years Tariff.5pkWhr *Further Information https://www.ofgem.gov.uk/environmentalprogrammes/domestic-renewable-heat-incentive https://gdcashback.decc.gov.uk/ https://www.gov.uk/crc-energy-efficiency-schemequalification-and-registration Changwon 3

WHT IS LG THERM V? What is LG THERM V? THERM V is LG s newest ir to Water Heat Pump system, especially designed for new housing and renovation by LG s advanced heating technology with energy saving. THERM V can be used as various heating solution from floor heating to hot water supply with multiple heat sources. Energy Efficient pplication Various pplication THERM V offers the best solution for home heating and hot water supply with LG s inverter technology. It is 4 times more energy efficient than boiler system by absorbing energy from the outdoor environment. Various kinds of application is possible with THERM V units including new house also renovation house. New House IR SOURCE Heating Hot Water Free energy Green energy Easy energy 75% 5% With low temp. monobloc & split model, heating and cooling can be done. Space Heating MONOBLOC Fan Coil Unit Outdoor ir Underfloor Heating Monobloc Domestic Hot Water Space Heating SPLIT Fan Coil Unit Optimal pplication dvanced model selection software enables designers to choose optimal THERM V model based on the location and environmental factors. Indoor Unit Underfloor Heating Model selection screen Monthly energy simulation Heat load & heat pump capacity System comparison chart Split Outdoor Unit Domestic Hot Water Renovation House THERM V can be connected to existing boiler system to optimize energy efficiency and heating capacity for renovation house. lso THERM V High Temperature can replace completely exiting boiler by providing 80 C hot water. MONOBLOC (or SPLIT) Space Heating (Max 57 C) Fan Coil Unit Reliable pplication Operation range for heating Outdoor Temperature ( C) Heating range for outdoor temperature is down to -0 C and leaving water temperature can reach max. 57 degree. Radiator 35 Operative 4 Continuous Operation Monobloc Existing Boiler Domestic Hot Water Space Heating (Max 80 C) SPLIT HIGH TEMP. Fan Coil Unit -15-0 15 0 4 50 57 Leaving Water Temperature ( C) * In case of Monobloc models. Indoor Unit Radiator High-Temp. Outdoor Unit Domestic Hot Water 5

WHY LG THERM V? Why LG THERM V? The LG Therma V is designed to create incomparable customer values like energy saving, comforts, easy controls and services by applying the advanced technologies. The LG inverter technology provides excellent energy efficiency with optimal components such as water pump, heat exchanger and fan motor. Moreover, the pressure control technology provides stable heating capacity at low temperature and reaches target performance without difficulties. dditionally, the differentiated structure like allin-one type, gold-fin and users-oriented functions enhance professionals reputations as well as endusers happiness by experiencing the LG s full line-up from 3kW to 16kW in heating capacity. 1 ENERGY EFFICIENCY CONVENIENCE & COMFORT 3 ESY INSTLLTION & SVC p. 08 - Highly efficient inverter compressor - Savings from energy efficient water pump - Energy efficiency at - C - Optimized components p. 10 p. 1 - Stable heating capacity with refrigerant pressure control - Low operating noise - Convenient control for end-users - Compact size & light weight for easy installation - ll-in-one type for quick and reliable installation - Improved structure for easy service - Emergency operation mode - Service & Warranty support

ENERGY EFFICIENCY 1 Energy Efficiency Powerful BLDC * Compressor *BLDC : Brushless DC Motor THERM V is equipped with a BLDC* compressor that uses a strong neodymium magnet. The compressor has improved efficiency compared to standard C inverter product and it is optimized for seasonal efficiency. COP BLDC Inverter Compressor Energy Efficiency at - C Energy efficiency is higher than others. (Condition : mbient temp. - C / Leaving water temp. 55 C).5.0 1.5..05 1.88 1.96 1.7 Heating COP (- / W55) 1.79 1.99 1.99.0.16.00.16 1.99 1.88 LG Company B Company C Company D Company 1.0 0.5 8% 4% 0.0 1kW 14kW 16kW Standard C Compressor * Peak value / Monobloc models. 40Hz 60Hz 80Hz Frequency (Hz) Minimized oil circulation High efficiency motor Optimized compression Optimized vibration, noise High reliability Conventional Distributed Winding New Concentrated Winding Heat Exchanger Improvement Efficiency and performance are improved by increased heat exchange rate of wide louver fin & new optimal distributor design applied to the heat exchanger. Wide Louver Fin Improved heat exchanger efficiency of up to 8%. Optimized Heat Exchanger Path Improved cycle efficiency up to 5% with equal distribution. Heat Exchange Rate (%) High Efficient Water Pump THERM V is equipped with a high efficiency -Class water pump. The pump pressure is adjustable, to suit design conditions. Power input saving by High efficient -Class water pump Heating 13% Conventional Unequal Distribution New Equal Distribution 3 / 5 / 7 / 9 kw 1 / 14 / 16 kw 34 kwh/year Conventional 65% 153 kwh/year 81 kwh/year -Class * Condition : 1 hours x 30 days x 5 month (estimated value) Inverter BLDC Fan Motor LG BLDC fan motor offers additional energy savings up to 40% at low speed and 0% at high speed compared to an C motor. Efficiency (%) 100 80 60 40 0 40% increase BLDC Motor 0% increase C Motor 0 00 400 600 800 1,000 Motor Speed (RPM) 8 9

Convenience & Comfort Convenience & Comfort Reliability at Low Temperature Pressure control reinforces heating performance by operating in stable condition at low ambient temperature. Pressure Control Temperature Sensor Pressure Sensor This ensures to reach target performance point without failing to keep a reliable operation. Improved Fan for Low Noise The New xial Fan has a narrow hub blade and mogul trailing edge, this provides a high efficiency, low noise as well as improving the air flow rate. Mogul trailing edge Temperature Control Temperature Sensor Only This algorithm is more likely to be affected by temperature change and it takes more time to calculate proper operation range of compressor to target point. 56mm Reverse hub Heating Capacity at Low Temperature High and stable performance at low temperatures. Stable Operation High and stable heating performance at low temperatures. Narrow hub blade Heating Capacity (kw, -15 C, LWT50 C) 9 8 7 6 5 4 0 Conventional New model 5.66.1% 4.41 HM091M 8.5% 5.44 7.6 HM11M 4.% 6.68 8.81 HM141M Conventional Room Temp. ( C) Room Temp. ( C) 3 16 New 3 16 Continuous Operation Time Time Weather Dependent Operation Conventional If users choose this mode, setting temperature will follow outdoor temperature automatically. If outdoor temperature decreases, heating capacity for the house will increase automatically in order to keep comfortable heating performance according to weather. Leaving Water Temp.( C) Max. 57 Min. 15 New Min. -0 Max. 0 Outdoor Temp. ( C) Silent Mode & Scheduler Silent mode operation can reduce the noise level specially during the setting time by remote controller and users can set the weekly on/off schedule also. Heating Capacity Heating Sound Pressure (db) (kw) Normal Silent Mode 3 47 43 5 51 48 7 5 48 9 5 48 1 53 50 14 53 50 16 53 50 Capacity Noise Level Mode Start Down Compressor & Fan Hz Mode End nti-legionella Function By setting nti-legionella operation mode on, THERM V heats the whole water tank automatically once a week until water temperature reach up to 80 C. Target anti-legionella temp. (40~80 C) Mode duration time (5~60 min.) Time 10 11

Easy Installation & SVC 3 Easy Installation & SVC Ez Installation & SVC ll-in-one concept LG will provide fully packaged monobloc with 4 main component. (except 3kW monobloc) basically. No need to work refrigerant piping, easier and quicker installation. Emergency Operation Even in case of sudden product error, THERM V ensures stable heating operation by applying steps of emergency control. Conventional PHE (Plate Heat Exchanger) -Class Water Pump Electric Heater Expansion Tank In case of Minor Error (Mainly caused by sensor) - THERM V = ON, Electric Heater = ON/OFF In case of Major Error (Mainly caused by cycle parts) - THERM V = OFF, Electric Heater = ON LG THERM V Ez SVC 3 pieces of screw Corrosion Resistant Heat Exchanger LG s Outdoor Heat Exchanger is coated with a gold-colored anti-corrosive epoxy treatment on the aluminum coil, to prevent corrosion. This maintains excellent heat transfer properties of the coil for an extended time, whereas non-gold Fin coils progressively lose efficiency due to surface corrosion. Gold Fin fin is perfect for areas with high pollution or locations exposed to saltwater spray from the sea. Compact & Slim Compact design & Ez SVC - Remove 3 pieces of screw for SVC - Front panel removal system 3-Way charging pipe (Split type only) Refrigerating connection is possible in three directions. Therma V is shaped to minimize the size and weight in order to help easy and efficient work condition for installation. Composition of Fin screens luminum Material Corrosion- Resistant Screen Hydrophilic Screen LG Gold Fin Protected luminum Salt Spray Test for 15 Days LG Gold Fin Corrosion Resistance Uncoated luminum Conventional Starting to corrode Gold Fin is long lasting, durable and makes the Outdoor Unit look prestigious. SPLIT TYPE (16kW) 950mm MONOBLOC TYPE (3kW) Service and Warranty LG provide various levels of technical support to cover model selection & quotation, installation, commissioning and spare parts & warranty. 3 Levels of Technical Service 1,380mm 834mm 950mm 1 Level Level 3 Level BEFORE INSTLLTION On-site support Commissioning & warranty validation - Model selection - Energy simulation - Life time cost simulation - Quotation - Engineers visit (on demand) - Consultative support - LG Hot-line support - Installation assistance - Pre commissioning - Commissioning - Post commissioning - Spare parts - Warranty SVC LG Warranty Package (The UK example) Pre-preventive action Post-control action 105kg 61kg - Free technical training - Free WHP health check* - Dedicated spare parts division - TM44 CIBSE Energy inspections - 3 years warranty for all parts and a contribution towards labor. - Optional 5 year warranty on parts with the LG pproved Installer Scheme. - On-site attendance within 48 hours.** - SMS or email fault code diagnostics. * If 3 warranty issues are claimed within the warranty period. ** Mainland UK only; excluding Northern Ireland, Scottish Highlands and Islands, Eire (Monday-Friday). 1 13

Therma V high Temperature Model Therma V high Temperature Low Maximum Current Level LG High Temperature THERM V can be easily installed without any additional electric connection cost. Maximum current of single phase 16kW model 60 50 40 30 0 10 0 50.8 3.8 7 company 39 (77%) 0 19 LG Indoor Unit Outdoor Unit Enhanced Efficiency & Performance THERM V high temp. can produce Max. 80 C hot water with high efficiency (Max. COP 4.06 at 4 C ODT & 40/45 EWT/LWT) through cascade stage compression technology. Leaving water temperature ( C) 90 80 70 60 Oil / Gas Boiler Enhanced Efficiency Enhanced Performance Split HT Model Quick Defrosting Through R134 compressor controlling technology, necessary time for defrost operation has been minimized effectively. (LG Patent) Cold Water Hot Water R134a-Water HEX Hot Gas R410-R134a HEX Defrost end Defrost start Hybrid Defrosting Normal Defrosting 8min. 10min. Time s compared to normal reverse cycle defrost, 5% reduction in defrost time, and 10% increase of integrated heating capacity is achieved using hybrid defrosting. ir-r410 HEX 50 Monobloc & Split LT Model Cascade Stage Compression Technology 0 1.00.00 3.00 4.00 COP *Condition for HT model : Outdoor air temp. 18 C, entering water temp. 70 C *Condition for LT model : Outdoor air temp. 18 C, entering water temp. 50 C Max. 80 C hot water can be generated through Cascade R410 to R134 BLDC compressor technology and applicable for existing old boiler heating system which demands hot water supply. High temperature through Cascade cycle technology Low Noise Level R134a Comp Hydro-Kit (Hot Gas Bypass) Through cutting edge technology for DC inverter compressor, operating noise level of indoor & outdoor unit has been reduced and serves more comfort. Sound Pressure (db) 60 50 40 30 0 10 0 R410 Comp Outdoor Unit (Reverse Cycle) 46 55 company 43 LG Indoor Unit Outdoor Unit 53 Pressure ir R134 R410 Water Enthalpy Second Stage First Stage Higher Energy Efficiency By applying efficient compressor and optimally designed structure, the more energy saving, the lower operating cost make sooner return on initial investment. Heating COP at 7 C ODT Heating COP at -7 C ODT 14 15 COP 3.50 3.00.50.00 1.50 1.00 0.50 0.00 3.3 3.3 3.01 3.06 LG Company.51.61 7/W45 7/W55 7/W65 COP 3.50 3.00.50.00 1.50 1.00 0.50 0.00.5.83.1.5.1 1.91-7/W45-7/W55-7/W65 LG Company

ccessory ccessory ccessories provided by LG ccessory Domestic Hot Water Tank Feature LGRTV00E LGRTV00VE 198 LitERs 198 LitERs LGRTV300E LGRTV300VE 87 LitERs 87 LitERs Optional accessories supplied in the fields No. ccessory Picture Purpose Specification 1 Domestic Hot Water Tank 3-Way-Valve 3 Electrical Tank Heater Store and provide hot water for sanitation Switch between heating and domestic hot water circuit Supports heating of domestic hot water, when heat pump is blocked or capacity is limited Volume : 00-400 l enameld or stainless-steel tank / Insulating foam (e.g. PUR - polyurethane) heat-exchanger surface 3 m² 30V C SPDT (Single Pole Double Throw) / opening time 30-90 sec / final position switch Internal leakage rate < 0,1% -6 kw connector dimension suitable for DHW tank Domestic Hot Water Tank Kit Single Coil PHLT (1Ф, Split) PHLTC (3Ф, Split) PHLTB (Monobloc) Double Coil * The sensor (PHRST0) can be purchased separately in case of using other brand s Domestic tank. 4 Buffer Tank 5 Bypass Valve 6 -Way-Valve Prevents cycling, when water volume is low and/ or heating demand is low; secures enough heat for defrosting cycle Ensures minimum water flow rate, when flow through heating circuits is limited due to closed valves Blocks heating circuits, that are not suitable for cooling during cooling operation Insulating foam (e.g. PUR - polyurethane) Volume : 100-00 l (installation in series with heat pump) 500~1,000 l (installation in parallel with heat pump) dimensioning according manufacturer adjustable opening pressure 30V C NO or NC type final position switch Features PHLT / PHLTC Easy to install the domestic hot water for monobloc. There is a MCCB to protect the product. Dimension(mm) (HxWxD) : 50x170x110 Weight(kg) :.1 To extend THERM V functionality in generating domestic hot water. PHLTB 7 Expansion Vessel 8 Strainer 9 Heating Cable bsorption of pressure differences in the heating circuits due to temperature increase/decrease of the water Protects plate-heat-exchanger from blocking particles Prevents the condensate pan and the drainage pipe from icing dimensioning on-site required 1inch / 5.4mm, Mesh size ~ 1x1mm for HM03M1.U4 only (other models are included) Thermostatic control depending on outdoor temperature Remote Temperature Sensor Solar Thermal Kit Dry Contact PQRST0 Features It can help to detect the exact room temperature. pplied to ceiling cassette, ceiling concealed duct, WHP and Hydro Kit. Parts Included Remote temperature sensor / Extension cable (15m) / Manual PHLL Features To interface solar-thermal system with THERM V and double coil Domestic tank. Installed at the water pipe, between Domestic tank and solar-thermal system. Dimension(mm) (HxWxD) : 110x55x PQDS Features For connection with boiler(bivalent scene) 10 Condensate Pan 11 ntifreeze 1 Noise Damper 13 nti-noise Sockets 14 Thermostat 15 Refrigerant Tubes 16 Water Tubes 17 Bushing Sleeve 18 Insulation Material Collects condensate water (when dropping to the base is not possible) and drains the water to a pipe Prevents the heating water from freezing, when heat pump is out of order Prevents that structure-born noise is transported via the water piping Prevents that structure-born noise is transported to the base or to the brackets When thermostatic room temperature control is preferred by costumer Pre-fabricated double-pipe to connect split indoor and outdoor unit Pre-fabricated double-pipe to connect monobloc outdoor unit with heating system Protecting the building against pressing water coming through the duct of the heating tubes Mandatory when heat pump is used for cooling; prevents condensate water on cold pipes and assemblies diameter of drainage at least 3/4 Minimum dimensions according to chassis sizes (refer to specification) plus 5-10cm in width and length Monoethyleneglycole Concentration according to lowest possible outdoor temperature EPDM; Operating temperature according climate region (at least -10 ~ 90 C) dimensioning on-site required 30V C when heat pumps operates in heating and cooling mode: thermostat with mode selection Diameter: Please refer to Specification when heat pump is used for cooling: diffusion-resistant tubes dimensioning on-site required diffusion-resistant 16 17

Flexible pplications Flexible pplications Table of the Hydraulic pplications This shows some examples of how to integrate the THERM V into the heating system according to each customer needs. Each application is accompanied with the representative connection and installation explanations with symbol icons. Case 1. Split _ for Floor Heating Case Heating DHW Heating & Cooling Bivalent with boiler Double Zone Heating 1 3 4 5 6 * Combinations of these systems might be possible. Please refer to your local LG heating specialist. * High Temperature 80 C '' Used Symbols Case. Monobloc _ for Floor Heating & DHW Fan coil units with condensate drainage Fitting module for heating circuit Fitting module for underfloor heating circuit with mixer Split outdoor unit Monobloc outdoor unit Domestic hot water tank Radiator heating circuit Manifold with differential pressure Differential-pressureless manifold Split indoor unit Boiler Underfloor heating circuit Pressure-relief valve Drainage Ball valve with manual shut-off Cap valve T Buffer tank as hydraulic separator Buffer tank in serial installation High-temperature split indoor unit Controller Electric immersion heater T E Electronic thermostat Room temperature sensor Expansion vessel Circulating pump Immersion temperature sensor Overflow valve 3-way valve / -way valve / mixing valve control valve Non-return flap Strainer Shut-off valve with integrated draining device Thermostatic valve 18 19 ''

Flexible pplications Case 3. Split _ for Floor Heating & DHW & Cooling with Fan coil unit Case 5. Split _ for Floor Heating & Radiator & DHW with Boiler (Bivalent Scene) dditional Controller (not supplied by LG): - Bivalent-alternative operation according outdoor temperature (switching between heat pump and boiler) - Control of Heating circuits (mixer & pumps) Electric wiring (for details refer to wiring diagrams in the manual) 1) Power supply Outdoor unit ) Indoor-Outdoor unit connection 3) Power supply Internal Electric Heater (E/HT) 4) Power supply Electric Tank Heater (B/HT) 5) Power supply boiler 4 Dry contact (PQDS/ PQDSB) Buffer tank in parallel 4 T E * ROOM * THERMO- SENSOR STT [PQRST0] High temp. (Radiators) max. 55 C T E * External Thermostat Low temp. (Underfloor heating) 3 max. 58 C 1 5 Hot Domestic hot water tank Heat pump - Heating (above bivalent temperature) Expansion vessel '' '' Boiler - Heating (below bivalent temperature) - Domestic hot water (all-season) when boiler is blocked for heating, DHW should still be activated! Expansion vessel Cold Case 4. Split _ for Floor Heating & Radiator & DHW ( Zone heating) Case 6. Split (High temp.) _ for Floor Heating & DHW & Fan coil units Electric wiring (for details refer to wiring diagrams in the manual) 1) Power supply Outdoor unit ) Indoor-Outdoor unit connection 3) Power supply Indoor unit 4) Power supply Electric Tank Heater (B/HT) 4 3 CN-REMO Hot E T * ROOM * THERMO- SENSOR STT [PQRST0] Fan coil units 4 E T * External Thermostat (Underfloor) Heating circuits PUMP () Drainage Ø TH6 T 3 3-WY () B B 3 1 *B/ HET 3 -WY () Cold * Buffer tank '' '' Expansion vessel 0 1

Before Sales & fter Sales Service Before Sales & fter Sales Service THERM V Selection Program LTS THERM V simulates quick and easy result of THERM V s economic benefits. By specifying a number of parameters, this program shows annual energy cost compared with conventional heating system and CO annual amount, monthly energy amount and cost, total amount of thermal energy in kwh as the outside temperature. Service and Warranty dedicated Technical Service department and LG s authorized Service Centers provide various levels of technical support to cover model selection & quotation, installation, commissioning and spar parts & warranty. 3 Levels of Technical Service 1 Level Level 3 Level BEFORE INSTLLTION - Model selection - Energy simulation - Life time cost simulation - Quotation On-site support - Engineers visit (on demand) - Consultative support - LG Hot-line support - Installation assistance Commissioning & warranty validation - Pre commissioning - Commissioning - Post commissioning - Spare parts - Warranty SVC LG Warranty Package (The UK Example) Pre-preventive action - Free technical training - Free WHP health check* - Dedicated spare parts division - TM44 CIBSE Energy inspections Post-control action - 3 years warranty for all parts and a contribution towards labor - Optional 5 year warranty on parts with the LG pproved Installer Scheme - On-site attendance within 48 hours** - SMS or email fault code diagnostics * If 3 warranty issues are claimed within the warranty period. ** Mainland UK only; excluding Northern Ireland, Scottish Highlands and Islands, Eire (Monday-Friday). SMS 4/7 Just text the 1, or 3 digital fault code to : 0764 818 794 vailable 4 hours a day, 365 days per year. @ E-mail support Send your question by e-mail to : uk.aircon@lge.com vailable Monday to Friday between 09:00 and 17:00 Telephone Speak to an LG engineer call : 08448 471 40 and select Option 4. vailable Monday to Friday between 09:00 and 17:00 For specific enquiries please email Spare parts : aircon.spares@lge.com Warranty queries : aircon.warranty@lge.com Commissioning : aircon.commissioning@lge.com Training : aircon.training@lge.com LG Training and CPD Seminars (The UK Example) Two Training cademies positioned in the South and North of England Slough and Leeds, both equipped with the latest THERM V, LG ir to Water Heat Pump. Installers can gain hands-on practical experience of the product range as well as theory in the purpose built classroom. Training courses are free of charge. LG also offer CPD accredited seminars, which can be held at your offices or at our own premises. 3

014 Line-up 014 Full Line-up of LG WHP Type Monobloc Type Split Type Capacity Ф Product European Certificate Performance at Low ambient Reliability & Comfort Convenience 7 / W35 - / W55 Heating Operating Range COP Capacity COP Capacity 3kW 1Ф 4.10 3.00 1.94 1.80 5kW 1Ф 4.4 4.99.08 3.01 7kW 1Ф 4.30 7.00.03 4.1 9kW 1Ф 4.09 9.00.04 5.41 1kW 14kW 16kW 3kW* 5kW* 7kW* 9kW* 1kW 14kW 16kW 1Ф 4.49 1.00.05 7.7 3Ф 4.49 1.00.04 7.31 1Ф 4.44 14.00.04 8.4 3Ф 4.44 14.00.03 8.40 Outdoor Temp. 35 C 35 C 35 C 35 C 35 C 35 C 1Ф 4.0 16.00.03 9.56 3Ф 4.0 16.00.0 9.57 35 C 1Ф 1Ф 1Ф 1Ф Work in Progress Work in Progress Work in Progress Work in Progress 4.6 3.00.16.19 4.55 5.00.11 4.11 4.40 7.00.17 5.0 4.3 9.00.00 5.85 1Ф 4.49 1.00.05 7.7 3Ф 4.41 1.00.04 7.31 1Ф 4.44 14.00.04 8.4 3Ф 4.3 14.00.03 8.40 30 C 30 C 30 C 30 C 30 C 30 C 1Ф 4.0 16.00.03 9.56 3Ф 4.0 16.00.0 9.57 30 C Leaving Water Temp. 0 C ~ 57 C 57 C 57 C 57 C 57 C 57 C 57 C 55 C 55 C 55 C 55 C 55 C 55 C 55 C BLDC Inverter Compressor Control Sensor Embedded Component -Class Water Pump -Class Water Pump PHE (Plate Heat Exchanger) Expansion Tank Electric Heater -Class Water Pump PHE (Plate Heat Exchanger) Expansion Tank Electric Heater PHE (Plate Heat Exchanger) Water Pump CLSS CLSS CLSS CLSS CLSS CLSS CLSS CLSS CLSS CLSS CLSS Normal Normal Normal Heat Exchanger Coating Electric Heater Size N/ 4kW 4kW 4kW 6kW 6kW 6kW N/ 4kW 4kW 4kW 6kW 6kW 6kW Capacity Control N/ Timer Emergency Operation Dry Contact Connectability Weather Dependant Operation 1 4H WEEKLY LEVEL N/ 1 4H WEEKLY LEVEL PHEX nti- Freezing Control Split High Temp. Type 16kW 1Ф.61 (7/W65) 16.00.6 16.60-35 C 5 C ~ 80 C N/ * These models will be available in Q1 015 4 * NF-PC / MCS certification is work in progress. Expected release Q 015. * Split 1,14,16kW certified only single phase for MCS certification. 5 PHE (Plate Heat Exchanger) N/ N/ 1 4H WEEKLY LEVEL

Specification Monobloc Type Monobloc (Outdoor Unit) Capacity 3kW 1Ф 5kW 1Ф 7kW 1Ф 9kW 1Ф Reference HM031M.U4 HM051M.U4 HM071M.U4 HM091M.U4 Heating (7/W35) kw 3.00 4.99 7.00 9.00 Heating (/W50) kw.10 3.49 4.89 6.9 Nominal Capacity Heating (-/W50) kw 1.96 3.6 4.57 5.88 Heating (-7/W35) kw.83 4.7 6.61 8.61 Cooling (35/W18) kw - 4.99 7.00 9.00 Heating (7/W35) kw 0.73 1.13 1.63.0 Heating (/W50) kw 0.90 1.40.01.57 Nominal Power Input Heating (-/W50) kw 0.89 1.39 1.98.65 Heating (-7/W35) kw 1.10 1.7.45 3.19 Cooling (35/W18) kw - 1.39.00.65 Heating (7/W35) 4.10 4.4 4.30 4.09 COP Heating (/W50).33.49.43.45 Heating (-/W50).0.35.31. Heating (-7/W35).57.74.70.70 EER Cooling (35/W18) - 3.59 3.50 3.40 Dimension W*H*D mm 950 x 834 x 330 1,39 x 907 x 390 Weight kg 61 99 Sound Pressure Level (Heating) db() 47 51 5 5 Outdoor ir Operation Range Leaving Water Temp. Range Water Pipe Connection Electric Heater Heating CDB -0 ~ 35 Cooling CDB 5 ~ 48 Heating C 0 ~ 57 15 ~ 57 Cooling C - 6 ~ 35 Inlet mm(inch) Female PT 5(1) Outlet mm(inch) Female PT 5(1) Power Supply P/V/Hz - 1 / 0-40 / 50 Capacity kw - 4 Water Flowrate Limit LPM Min. 15 Max. Water Head m 6 7 Power Supply P/V/Hz 1 / 0-40 / 50 Recommended Fuse 0 Monobloc (Outdoor Unit) Capacity 1kW 1Ф 14kW 1Ф 16kW 1Ф 1kW 3Ф 14kW 3Ф 16kW 3Ф Reference HM11M.U3 HM141M.U3 HM161M.U3 HM13M.U3 HM143M.U3 HM163M.U3 Heating (7/W35) kw 1.00 14.00 16.00 1.00 14.00 16.00 Heating (/W50) kw 8.50 9.78 11.03 8.55 9.83 11.9 Nominal Capacity Heating (-/W50) kw 7.94 9.14 10.30 7.99 9.18 10.54 Heating (-7/W35) kw 11.48 13.11 14.80 11.48 13.11 14.9 Cooling (35/W18) kw 14.50 15.50 16.10 14.50 15.50 16.10 Heating (7/W35) kw.67 3.15 3.81.67 3.15 3.81 Heating (/W50) kw 3.41 4.00 4.60 3.49 4.07 4.73 Nominal Power Input Heating (-/W50) kw 3.30 3.95 4.63 3.40 4.00 4.63 Heating (-7/W35) kw 4.16 4.85 5.61 4.16 4.85 5.95 Cooling (35/W18) kw 4.00 4.69 5.07 4.00 4.69 5.07 Heating (7/W35) 4.49 4.44 4.0 4.49 4.44 4.0 Cop Heating (/W50).49.45.40.45.4.39 Heating (-/W50).41.31..35.30.8 Heating (-7/W35).76.70.64.76.70.51 Eer Cooling (35/W18) 3.63 3.30 3.18 3.63 3.30 3.18 Dimension W*H*D mm 1,39 x 1,450 x 390 Weight Kg 141 Sound Pressure Level (Heating) db() 53 Outdoor ir Operation Range Leaving Water Temp. Range Water Pipe Connection Electric Heater Heating CDB -0 ~ 35 Cooling CDB 5 ~ 48 Heating C 15 ~ 57 Cooling C 6 ~ 35 Inlet mm(inch) Female PT 5(1) Outlet mm(inch) Female PT 5(1) Power Supply P/V/Hz 1 / 0-40 / 50 Capacity kw 6 Water Flowrate Limit LPM Min. 15 Max. Water Head m 8 Power Supply P/V/Hz 1 / 0-40 / 50 3 / 380-415 / 50 Recommended Fuse 3 10 6 7

Specification SPlit Type Split (Outdoor Unit) Capacity 3kW 1Ф 5kW 1Ф 7kW 1Ф 9kW 1Ф Reference HU031.UE* HU051.U4* HU071.U4* HU091.U4* Heating (7/W35) kw 3.00 5.00 7.00 9.00 Heating (/W50) kw.5 4.08 5.19 6.04 Nominal Capacity Heating (-/W50) kw.6 4.16 5.5 5.98 Heating (-7/W35) kw.89 4.9 6.70 8.11 Cooling (35/W18) kw 3.00 5.00 7.00 9.00 Heating (7/W35) kw 0.65 1.10 1.59.13 Heating (/W50) kw 0.89 1.59.07.59 Nominal Power Input Heating (-/W50) kw 0.93 1.73.18.64 Heating (-7/W35) kw 1.0 1.69.31 3.03 Cooling (35/W18) kw 0.75 1.35.05.90 Heating (7/W35) 4.6 4.55 4.40 4.3 COP Heating (/W50).53.57.51.33 Heating (-/W50).44.40.41.7 Heating (-7/W35).83.91.90.68 EER Cooling (35/W18) 4.00 3.70 3.41 3.10 Dimension W*H*D mm 870 655 30 950 x 834 x 330 950 x 834 x 330 950 x 834 x 330 Weight kg 46 64 64 64 Sound Pressure Level (Heating) db() 51 54 54 54 Outdoor ir Operation Range Refrigerant (R410a) Ref. Pipe Length Split (Indoor Unit) Capacity 3kW 5,7, 9kW Reference HN0314.NK HN0914.NK Dimension W*H*D mm 490*850*315 490*850*315 490*850*315 490 x 850 x 315 Weight kg 47 48 48 48 Electric Heater Power Supply P/V/Hz 1 / 0-40 / 50 1 / 0-40 / 50 1 / 0-40 / 50 1 / 0-40 / 50 Capacity kw 4 4 4 4 Leaving Water Temp. Range Heating CDB -0 ~ 30-0~30-0~30-0~30 Cooling CDB 5 ~ 48 5~48 5~48 5~48 Pipe Diameter (Liquid) mm(inch) Ф 6.35(1/4) 9.5(3/8) 9.5(3/8) 9.5(3/8) Pipe Diameter (Gas) mm(inch) Ф 1.7(1/) 15.88(5/8) 15.88(5/8) 15.88(5/8) Pre-Charged mount kg 1 1.55 1.55 1.55 Chargeless Pipe Length m 7.5 7.5 7.5 7.5 dditional Charging Volume g/m 0 40 40 40 Minimum m - - - - Standard m 7.5 7.5 7.5 7.5 Maximum m 40 50 50 50 Power Supply P/V/Hz 1/0-40/50 1/0-40/50 1/0-40/50 1 / 0-40 / 50 Recommended Fuse 0 0 0 0 Heating C 15~55 15~55 15~55 15~55 Cooling C 6~30 6~30 6~30 6~30 Water Flowrate Limit LPM Min. 8 Min. 15 Min. 15 Min. 15 Max. Water Head m 6 7 7 6 Water Pipe Connection Inlet mm(inch) Male PT 5(1) Male PT 5(1) Male PT 5(1) Male PT 5(1) Outlet mm(inch) Male PT 5(1) Male PT 5(1) Male PT 5(1) Male PT 5(1) Split (Outdoor Unit) Capacity 1kW 1Ф 14kW 1Ф 16kW 1Ф 1kW 3Ф 14kW 3Ф 16kW 3Ф Reference HU11. U31 HU141. U31 HU161. U31 HU13. U31 HU143. U31 HU163. U31 Heating (7/W35) kw 1.00 14.00 16.00 1.00 14.00 16.00 Heating (/W50) kw 8.50 9.78 11.03 8.55 9.83 11.30 Nominal Capacity Heating (-/W50) kw 7.94 9.14 10.30 7.99 9.18 10.50 Heating (-7/W35) kw 11.48 13.11 14.80 11.66 1.7 14.9 Cooling (35/W18) kw 14.50 15.50 16.10 14.60 15.50 16.80 Heating (7/W35) kw.67 3.15 3.81.7 3.4 3.81 Heating (/W50) kw 3.41 4.00 4.60 3.49 4.07 4.73 Nominal Power Input Heating (-/W50) kw 3.30 3.95 4.63 3.40 4.00 4.63 Heating (-7/W35) kw 4.16 4.85 5.61 4.31 4.98 5.95 Cooling (35/W18) kw 4.00 4.69 5.07 4.0 4.65 5.09 Heating (7/W35) 4.49 4.44 4.0 4.41 4.3 4.0 COP Heating (/W50).49.45.40.45.4.39 Heating (-/W50).41.31..35.30.7 Heating (-7/W35).76.70.64.71.55.51 EER Cooling (35/W18) 3.63 3.30 3.18 3.63 3.33 3.30 Dimension W*H*D mm 950 x 1,380 x 330 Weight kg 105 Sound Pressure Level (Heating) db() 53 Outdoor ir Operation Range Refrigerant (R410a) Ref. Pipe Length Heating CDB -0 ~ 30 Cooling CDB 5 ~ 48 Pipe Diameter (Liquid) mm(inch) 9.5 (3/8) Pipe Diameter (Gas) mm(inch) 15.88 (5/8) Pre-Charged mount Kg.85.85.85.98.98.98 Chargeless Pipe Length m 7.5 7.5 7.5 7.5 7.5 7.5 dditional Charging Volume g/m 60 60 60 60 60 60 Minimum m 3 Standard m 7.5 Maximum m 50 Power Supply P/V/Hz 1 / 0-40 / 50 3 / 380-415 / 50 Recommended Fuse 3 16 Split (Indoor Unit) Capacity 1~16kW Reference HN1616.NK1 HN166.NK1 HN169.NK1 HN1636.NK1 HN1639.NK1 Dimension W*H*D mm 490 x 850 x 315 Weight kg 54.5 Electric Heater Power Supply P/V/Hz 1 / 0-40 / 50 3 / 0 / 50 3 / 380-415 / 50 Capacity kw 6 6 9 6 9 Leaving Water Temp. Range Heating C 15 ~ 55 Cooling C 6 ~ 30 Water Flowrate Limit LPM Min. 15 Max. Water Head m 7 Water Pipe Connection Inlet mm(inch) Male PT 5 (1) Outlet mm(inch) Male PT 5 (1) * Combination Table Outdoor Unit (1Ф) Indoor Unit * These models will be available in Q1 015 3kW 5kW 7kW 9kW HU031.UE HU051.U4 HU071.U4 HU091.U4 HN0314.NK HN0914.NK HN0914.NK HN0914.NK * Combination Table Outdoor Unit (1Ф) HU11.U31 HU141.U31 HU161.U31 Outdoor Unit (3Ф) HU13.U31 HU143.U31 HU163.U31 1kW 14kW 16kW 1kW 14kW 16kW HN1616. NK1 HN1616. NK1 HN1616. NK1 HN1616. NK1 HN1616. NK1 HN1616. NK1 Indoor Unit HN166. NK1 HN166. NK1 HN166. NK1 HN166. NK1 HN166. NK1 HN166. NK1 Indoor Unit HN1636. NK1 HN1636. NK1 HN1636. NK1 HN1636. NK1 HN1636. NK1 HN1636. NK1 HN169. NK1 HN169. NK1 HN169. NK1 HN169. NK1 HN169. NK1 HN169. NK1 HN1639. NK1 HN1639. NK1 HN1639. NK1 HN1639. NK1 HN1639. NK1 HN1639. NK1 8 9

Specification High Temperture Type Domestic Hot Water Tank High Temp. Split (Outdoor Unit) Capacity 16kW 1Ф Reference HU161H.U3 Heating (7/W65) kw 16 Nominal Heating (/W65) kw 14.6 Capacity Heating (-/W65) kw 15.7 Heating (-7/W65) kw 15.1 Nominal Power Input COP Heating (7/W65) kw 6.13 Heating (/W65) kw 6.81 Heating (-/W65) kw 6.96 Heating (-7/W65) kw 7. Heating (7/W65).61 Heating (/W65).14 Heating (-/W65).6 Heating (-7/W65).10 Dimension W*H*D mm 950 x 1,380 x 330 Weight Kg 105 Sound Pressure Level (Heating) db() 53 Outdoor ir Operation Range Heating CDB -15 ~ 35 Pipe Diameter (Liquid) mm(inch) 9.5 (3/8) Pipe Diameter (Gas) mm(inch) 15.88 (5/8) Refrigerant (R410a) Pre-Charged mount Kg 3.5 Chargeless Pipe Length m 10 dditional Charging Volume G/m 60 Minimum m 5 Ref. Pipe Length Standard m 7.5 Maximum m 50 Power Supply P/V/Hz 1 / 0-40 / 50 Recommended Fuse 5 Domestic Hot Water Tank Double Coil Domestic Hot Water Tank LGRTV00VE LGRTV300VE General Characteristics Characteristics of Electrical Back-up Characteristics of Exchanger Hydraulic Connections Heat Pump Hydraulic connections Domestic Hot Water Tank Water Volume L 198 87 Diameter mm 580 580 Height mm 1,30 1,680 Empty Weight kg 50 64 Tank Materials Stainless Steel Stainless Steel Outer Skin Materials Paint Epoxy Paint Epoxy Color White RL White NC White NC dditional Electric Heater kw 3 3 djustable Thermostat C 60 ~ 90 60 ~ 90 Exchanger Type Double Double Material Exchanger LDX 101 Stainless Steel LDX 101 Stainless Steel Maximum Water Temperature C 80 (With an Heat Pump) 80 (With an Heat Pump) Coil Surface mm 0.94 0.94 THERM V Entry mm 5 5 THERM V Exit mm 5 5 City Water Entry mm Hot water Exit mm Electric connection Supply Ф/V/Hz 1Ф / 0-40V 50Hz 1Ф / 0-40V 50Hz MNDTORY OPTIONL CCESSORIES Domestic Hot Water Tank Installation Kit PHLT PHLT High Temp. Split (Indoor Unit) Capacity 16kW 1Ф Reference HN1610H.NK Dimension W*H*D mm 50 x 1,080 x 330 Weight kg 94 Sound Pressure Level (Heating) db() 43 Nominal Power Input Heating kw 6.13 Leaving Water Temp. Range Heating C 5 ~ 80 Water Flowrate Limit LPM Min. 15 Pipe Diameter (Liquid) mm(inch) 9.5 (3/8) Refrigerant (R134a) Pipe Diameter (Gas) mm(inch) 15.88 (5/8) Pre-Charged mount kg.3 Water Pipe Connection Inlet mm(inch) Male PT 5 (1) Outlet mm(inch) Male PT 5 (1) Draining Pipe Connection mm(inch) Male PT 5 (1) Power Supply P/V/Hz 1 / 0-40 / 50 Recommended Fuse 5 30 31