First Alert 2C Installer Notes M. Leuck. Programming can done by standard keypads 2. Enter programming with Installer Code + 8 + + 3. Another method of entering programming: Power system down, then back up and within 3 seconds press * and # at the same time. 4. If system is armed when first powering up, power system back down, hold * and # while powering up system (not afterwards) to enter programming 5. To program a location press * then location. To view what is in Location press # then Location, keypad will read off what is currently programmed 6. To erase a location (Example: Phone Number) press * then Location then * again. Duress/Hostage Code is digit above any User Code Downloading Information It is IMPORTANT to enable downloading when first entering programming. Press * 44 and enter 5 2. Press * 36 and enter 5 5 5 5 5 5 5 5
* INSTALLER CODE 4 4 Enter 4 digits, -9 [44] * MASTER SECURITY CODE 2 3 4 Enter 4 digits, -9 [234] See *54 for 6 digit enable ASSIGN RESPONSE TYPE FOR ZONES -27 & PANICS Enter -; see Response types table below) Hard-wire zones = -9; Polling Loop zones = -64 plus RF Receiver zones 88-9 *2 *3 *4 *5 9 3 7 25 8 26 9 27 2 2 3 2 4 22 5 23 6 24 9 2 3 3 4 3 5 3 6 3 7 3 8 3 FA2C PROGRAMMING FORM Standard default (*97) values are shown in brackets [ ], otherwise default =. Not Used 97 5 Polling Loop Short 95 9 (+*/A) 96 8 (3+#/C) 99 7 (*+#/B) RESPONSE TYPES: = Disabled zone = ENTRY/EXIT # 2 = ENTRY/EXIT #2 3 = PERIMETER 4 = INTERIOR, FOLLOWER 5 = DAY/NIGHT 6 = 24-HOUR SILENT 7 = 24-HOUR AUDIBLE ALARM 8 = 24-HOUR AUXILIARY 9 = FIRE = INTERIOR, DELAY DESIGNATE RIGHT LOOP Zones -32: Enter [ = no]; = yes *6 ZONES: 2 3 4 5 6 *7 ZONES:7 8 9 2 2 22 23 24 *8 ZONES:25 26 27 28 29 3 3 32 *9 ENTRY DELAY # [2] (-5 times 5 seconds) 2 * EXIT DELAY # [3] (-5 times 5 seconds) 3 * ENTRY DELAY #2 [6] (-5 times 5 seconds) 6 *2 EXIT DELAY #2 [8] (-5 times 5 seconds) 8 *3 ALARM SOUNDER DURATION -5 times 2 minutes [4]. Minimum 4 minutes for UL. 3 *4 ZONE 9 FAST/SLOW RESP. [=Slow]; =Fast "" for UL. *5 KEYSWITCH ENABLE [ = Disable]; = Enable *6 CONFIRMATION OF ARMING DING =enable; [=disable] *7 AC POWER LOSS SOUNDING = yes; [=no] *8 AC POWER LOSS ALARM =Yes;[=No] *9 AC RANDOMIZE =Randomize -4 min.;[=no] *2 DISABLE FIRE TIME-OUT =No timeout [=Fire time-out] *23 MULTIPLE ALARMS [=Yes]; =No *24 49WH TAMPER DISABLE =Disable; [=Enable] *25 BURGLARY TRIGGER FOR ZONE RESPONSE TYPE 8 [=No]; =Yes *26 INTELLIGENT TEST REPORTING Set "" for UL =Yes, (No report sent if any other report was recently sent); [=No] *27 TEST REPORT INTERVAL 2 4 Enter interval in hours, -99; =No report [24]; Max. 24 for UL. *28 POWER UP IN PREVIOUS STATE [=Yes]; =No; "" for UL *29 QUICK ARM [=Yes]; =No *3 TOUCH TONE OR ROTARY DIAL =Touchtone; [=Rotary]; See field *33 for Touch-tone w/rotary backup *3 PABX ACCESS CODE -9; * = 4; # = 5 *32 PRIM. SBSCRBR ACCT# 2 3 4 Enter -9; B-F (-5) [5 5 5 5] *33 PRIMARY PHONE NUMBER Enter -9 for each digit *34 SECONDARY PHONE NUMBER Enter -9 for each digit *35 DOWNLOAD PHONE No. 8 6 8 2 6 9 Enter -9 for each digit *36 DOWNLOAD ID No. 5 5 5 5 5 5 5 5 Enter -9; A-F (-5) [5 5 5 5 5 5 5 5] *37 DOWNLOAD COMMAND ENABLES Dialer System Not Remote Remote Remote Upload Download Shutdown Shutdown Used Bypass Disarm Arm Program Program See *53 for Callback disable option. [=Enable]; =Disable For UL installations, All options must be disabled. *38 INHIBIT BYPASS OF A ZONE -3; [ if all zones (except Fire Zones) can be bypassed] *39 OPEN/CLOSE REPORTS FOR USERS -8 =Yes; =No 2 3 4 5 6 7 8 *4 OPEN/CLOSE REPORTS FOR USERS 9-6: =Yes; =No 9 2 3 4 5 6 *4 EOLR DISABLE (Zone 2-8) [=N.C. Loops]; =EOLR supervision; Must be "" for UL. Note: If keyswitch is enabled in field *5, you must enter "" here. *42 DIAL TONE PAUSE [=5 scs]; = scs; 2=3 scs; * for UL *43 DIAL TONE DETECT [=wait for dial tone]; =pause then dial *44 RING DETECTION COUNT -4; 5=answering machine; [=no detection] 5 *45 PRIMARY FORMAT [= Low Speed]; =Contact ID; 2=ADEMCO High Speed; 3=ADEMCO Express *46 LOW SPEED FORMAT (PRIMARY) [=ADEMCO Low Speed]; =Sescoa/Radionics *47 SECONDARY FORMAT [=Low Speed]; =Contact ID; 2=ADEMCO High Speed; 3=ADEMCO Express *48 LOW SPEED FORMAT(Secondary.) [=Ademco Low Speed]; =Sescoa/Radionics *49 CHECKSUM VERIFICATION =Yes; [=No] Primary Scndry *5 SESCOA/RADIONICS =Sescoa; [=Radionics] -A- FA2C-5+
*5 DUAL REPORTING =Yes; [=No] If used with Split Reporting "" option(*34), alarms go to both primary and secondary numbers, while all other reports go to secondary only. if used with Split Reporting "2" option, open/close and test messages go to both lines, while all other reports go to primary. *52 STANDARD/EXPANDED REPORT FOR PRIMARY Alarm Rstr Bypass Trbl Opn/Cls Low Bat [=Standard]; =expanded; Note: Expanded overrides 4+2 format. *53 STANDARD/EXPANDED REPORT FOR SECONDARY Alarm Rstr Bypass Trbl Opn/Cls Low Bat [=Standard]; =expanded; Note: Expanded overrides 4+2 format. ALARM REPORT CODE & ID DIGITS FOR ZONES -32 & SUPERVISORY & RESTORE CODES [All codes default to ] *54 Code *55 ID *56 Code *57 ID *58 *59 Code *6 ID *6 Code *62 ID 9 9 Alarm Rst. 7 25 2 2 Trouble 8 26 3 3 Trouble Rst. 9 27 4 4 2 Bypass 2 28 5 5 3 Bypass Rst. 2 29 6 6 4 22 3 7 7 5 23 3 8 8 6 24 32 *63 Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. ALARM REPORT CODE & ID DIGITS FOR ZONES 33-64 & SUPERVISORY & RESTORE CODES [All codes default to ] *64 Code *65 ID *66 Code *67 ID *68 *69 Code *7 ID *7 Code *72 ID *73 33 4 Alarm Rst. 49 57 34 42 Trouble 5 58 35 43 Trouble Rst. 5 59 36 44 Bypass 52 6 37 45 Bypass Rst. 53 6 38 46 54 62 39 47 55 63 4 48 56 64 Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. ALARM REPORT CODE & ID DIGITS FOR RF RCVRs & PANICS, & THEIR SUPV. & RESTORE CODES [All codes default to ] *74 Code *75 ID 8 82 83 84 85 86 87 88 *76 Code *77 ID 89 9 9 Duress 97 95 96 99 *78 ( + */A) (3 + #/C) (* + #/B) Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. NOTES: 97 = Poll Loop Short; 88 & 9= RCVR not receiving transmitter signals. 89 & 9= RCVR not responding, bad conn. to panel. *79 ZONE TYPE RESTORE for TYPES -8 =Enable; [=Disable] 2 3 4 5 6 7 8 *8 ZONE TYPE RESTORE for TYPES 9 & =Enable; [=Disable] 9 SYSTEM NON-ALARM CODES *8 *82 Close Open Low Battery Low Bat Res. AC Loss AC Restore Test Power Cancel Prog. tamper First Digit Second Digit Second digit of each applies only to 4+2 or expanded (fields *52 & *53) formats -B- FA2C-5+
*83 FIRST TEST REPORT TIME 2 [Day; hour 2; min ] Days -7 Hours -23 Min -59; in all boxes = instant (Day = Monday) *84 SWINGER SUPPRESSION 5-5 alarms [5]; Must be "" (disabled) for UL. *86 ZONE EXPANDER DEVICE = only one 428 installed for zones -7; [ = more than one 428 or other devices] *87 ENTRY WARNING [=Continuous]; =3 Beeps *88 BURG. ALARM COMM. DELAY =6 seconds; [=no delay *89 RESTORE REPORT TIMING [= instant, as zone restores]; =after bell timeout if zone restored; 2=when system is subsequently disarmed *9 SECONDARY SUBSCRIBER ACCOUNT # Enter -9; B-F(-5) [5 5 5 5] 5 5 5 SECOND PAGE FIELDS (*94) *OPEN/CLOSE REPORT ENABLE =Yes, [=No] USER 7 8 9 2 2 22 23-7 ASSIGN RESPONSE TYPES FOR ZONES 28-64 * *2 *3 *4 *5 28 29 3 3 32 33 34 35 36 37 38 39 4 *6 *7 *8 *9 65 73 66 74 67 75 68 76 69 77 7 78 7 79 72 8 4 42 43 44 45 46 47 48 49 5 5 52 53 54 55 56 8 82 83 84 85 86 87 88 2nd RCVR 88 & 9 = RCVR not receiving transmitter signals. 89 & 9 = RCVR not responding, bad conn. to panel. 57 58 59 6 6 62 63 64 89 2nd RCVR 9 st RCVR 9 st RCVR NOTES: Use of or 2 RF RCVRs requires enabling their respective faults (88-9) as troubles (type 5). Enter if no annunciation is desired. RESPONSE TYPES: = Disabled zone = ENTRY/EXIT # 2 = ENTRY/EXIT #2 3 = PERIMETER 4 = INTERIOR, FOLLOWER 5 = DAY/NIGHT 6 = 24-HOUR SILENT 7 = 24-HOUR AUDIBLE ALARM 8 = 24-HOUR AUXILIARY 9 = FIRE = INTERIOR, DELAY Zones 65-89: *4 ZONES:65 66 67 68 69 7 7 72 *5 ZONES:73 74 75 76 77 78 79 8 *6 ZONES:8 82 83 84 85 86 87 88 *7 ZONE: 89 SELECTION OF WIRELESS FOR ZONES -63 Enter "" to enable a zone as wireless; =non-wireless *8 ZONES: 2 3 4 5 6 7 8 *9 ZONES: 9 2 3 4 5 6 *2 ZONES:7 8 9 2 2 22 23 24 *2 ZONES:25 26 27 28 29 3 3 32 *22 ZONES:33 34 35 36 37 38 39 4 *23 ZONES:4 42 43 44 45 46 47 48 *24 ZONES:49 5 5 52 53 54 55 56 *25 ZONES:57 58 59 6 6 62 63 *26 FIRST RF RECEIVER SELECT =Yes; [=No] *27 SECOND RF RECEIVER SELECT =Yes; [=No] *28 RF TRANSMITTER LOW BATTERY ANNUN. =Immediate; [=when disarmed]; Must be "" for UL. *29 RF TRANSMITTER LOW BAT REPORT ENABLE =Enable; [=Disable] Must be "" for UL. *3 RF RECEIVER SUPERVISION CHECK-IN INTERVAL 2-5 times 2 Hours; disables supervision [6] Max. "6" (2 hr) for UL. 6 =Immediate;[=when disarmed]; Must be "" for UL. *3 RF TRANSMITTER CHECK-IN INTERVAL 2-5 times 2 Hours; 2 disables supervision [2] Max. "6" (2 hr) for UL. *32 RF RECEIVER TYPE None *33 TOUCH-TONE W/ROTARY BACKUP ENABLE =Enable; [=Disable] *34 COMM. SPLIT REPORT SELECTION [=No]; =Alarms primary, others secondary; 2=Open/close, test secondary, others primary; See *5 for comments CURRENT LCD DISPLAY FOR THIS SYSTEM ****Disarmed**** READY TO ARM DESIGNATE RIGHT LOOP Zones 33-64: Enter [ = no]; = yes * ZONES:33 34 35 36 37 38 39 4 * ZONES:4 42 43 44 45 46 47 48 *2 ZONES:49 5 5 52 53 54 55 56 *3 ZONES:57 58 59 6 6 62 63 64 -C- FA2C-5+
ALARM REPORT CODE & ID DIGITS FOR RF RCVRs & PANICS, & THEIR SUPV. & RESTORE CODES *35Code 65 66 67 68 69 7 7 72 *36 ID *37Code 73 74 75 76 77 78 79 8 *38 ID *39 Alarm Rst. Trouble Trouble Rst. Bypass Bypass Rst. ARMED STAY DIALER REPORT *4 *4 First Digit Second digit Armed Stay This report will be sent for any low speed format. If ADEMCO high speed is used, a normal closing report will be sent. If Contact ID is used, a new code, R44, will be sent. 685 Receivers that do not have revision 4.5 or higher will print an error message in place of the english text. *44 RF KEYPAD TAMPER DETECT =Yes; [=No] *45 ENABLE CONSOLE ANNUNCIATION. DURING EXIT DELAY =Enable; [=Disable] *46 AUXILIARY OUTPUT ENABLE =Ground start; =Open/close trigger; 2=Console Sounding; *47 ENABLE CHIME ANNUNCIATION ON EXTERNAL ALARM SOUNDER =Enable; [=Disable] *48 WIRELESS KEYPAD DISABLE =Disable; [=Enable] *49 SUPRESS TROUBLE SOUNDER FOR RF SUPERVISION [=Disable]; =Enable. Must be "" for UL. *5 BABYSITTER CODE =Enable; [=Disable]; (User 22) *5 428 HOUSE ID Enter -3 *52 CANCEL REPORT RESTRICTION =No restriction; [=Within Bell Timeout period only] *53 DOWNLOAD CALLBACK =callback not required; [=callback required]; Must be "" for UL. *54 HIGH SECURITY MODE =6 digit high security; [=4 digit normal] *6 USER 5 LIMITED USE -5 uses, then will automatically delete user 5 code; = disable this feature *6 SILENT BURGLARY ALARM =silent alarm; =external sounding *62 SILENT BURG. AUDIBLE UPON: =after alarm sounder timeout; = upon communication failure *63 USER 5 BYPASS ONLY = can only bypass zone types 2-4; = can do normal system functions *64 DELAYED EXTERNAL SOUNDER = 6 seconds; = instant sounding *65 ZONE TYPE RESTORE REPORT ENABLE TYPES -4 [=enable]; = disable 2 3 4 SUMMARY OF PROGRAMMING COMMANDS To enter program mode, enter installer code + [8] + [] + []. Enter first field address to begin programming. To set standard defaults, press *97 To set communications defaults, press *94 + one of the following: *8=low speed; *8=Ademco Express; *82=Ademco High Speed; *83=Ademco's Contact ID To change to second page of program fields, press *94 To return to st page of fields press *99 To erase account & phone number field entries, press [*] + field number + [*] To assign zone descriptors, press *93 + zone number To add custom words, press *93 + + word number (-2) To enter Installer's Message, press *93 + + To exit program mode, press *99 OR *98: *99 allows re-access to programming mode by installer code. *98 prevents re-access to programming mode by installer code. Default values are shown in brackets [ ]; otherwise default = HEXADECIMAL TO NUMERIC ENTRY CONVERSION = (REPORT CODES) = (SUBS ID, PABX OR DOWNLOAD ID) =, 2=2, 3=3, 4=4, 5=5, 6=6, 7=7, 8=8, 9=9, B=, C=2, D=3, E=4, F=5, A= (DOWNLOAD ID ONLY) -D- FA2C-5+
Monitronics Monitoring and Service: -8-447-9239 Ademco 44XMP Quick Reference Guide (M. Leuck) Arming (Away) Enter 4-digit User Code + AWAY (2), ARM light will turn on and the display will show AWAY Note: If system shows NOT READY press to view open zones Disarming and Silencing Alarms Enter 4 digit code + OFF key () If turning off an alarm enter 4 digit code + OFF key () again to clear alarm display Arming (Stay) Enter 4 digit code + STAY key (3), the ARM light will turn on and the display will show STAY PROPERTY OF MONITRONICS INC. Zone Bypassing Additional Codes Enter your code + BYPASS key (6) + zone (, 2, 5 etc). The display will show BYPASS and the zone bypassed Note: Fire/Smoke Detector Zones cannot be bypassed Enter MASTER CODE + CODE key (8) + User (3 to 69) + New User Code, system will beep when completed To delete a code Enter MASTER CODE + CODE key (8) + User (3 to 69) + Master Code again Note: The Master Code can only be changed by a Service Technician or by Downloading Door Chimes To turn chimes ON or OFF enter Master Code + CHIME key (9), if activated the display will show CHIME Instant Doors Enter 4-digit Code + INSTANT key (7) to arm, all Entry/Exit doors will arm with no entry delay and all motion will be bypassed. Display will show both STAY and INSTANT (Instant zones will return to normal when disarmed) (The Exit Delay is still active with this command) Trouble Display NO AC = Loss of AC power to the system LOW BAT = Main panel has a low battery, if LOW BAT appears with a zone number that zone has low battery CHECK = There is a problem with a zone (system will show zone number on display) ALARM = An alarm has occurred, enter 4-digit User Code + OFF () to remove Panic Buttons By holding down a combination of numbers will activate the Police, Fire and Medical Panics Press and # at same time for Police Panic Press and at the same time for Fire Panic Press 3 and # at the same time for Medical Panic Note: The Fire and Medical Panics may be reversed or disabled on some systems Do not pause more than 2 seconds between each keypress or system will ignore above commands (Irving) 2