Serie V.I.P. Congelatori -86 C F

Similar documents
V.I.P. Series -86 C Ultra Temperature Freezers. The Ideal 86 C, Preservation Environment in Capacities from 12 cu.ft. to 26 cu.ft.

V.I.P. Series -86 C Ultra Low Freezers

-86 C Ultra-Low Freezers

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

-86 C Ultra-Low Freezers

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

Ultra-Low and Cryogenic Solution

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Ultra-Low and Cryogenic Solutions

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

TwinGuard ULTRA LOW TEMPERATURE FREEZERS

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

-86 C Ultra-Low Freezers. How It s Made. Matters

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra-Low Temperature Chest Freezers

Refrigerated Incubators / Environmental Testing Chambers

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

Heated and Refrigerated Incubators

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Freezers. Laboratory & Plasma. i.series Horizon Series

Ultra low temperature freezers. -40 C and -86 C. Green Line

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

ULTRA.GUARD ultra low temperature freezer

Cardinal Health Ultra-Low Freezers. Protecting your samples requiring ultra-low storage

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

Refrigerators. Upright Blood Bank. i.series Horizon Series

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

REVCO MECHANICAL CRYOGENIC FREEZER

Thermo Scientific HERAfreeze Freezers Solutions for safe sample storage

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Thermo Scientific Harris Freezers. > Total sample protection, complete peace of mind

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

ULTRA LOW TEMPERATURE FREEZER. User Manual

Undercounter Refrigerators and Freezers. Laboratory/Pharmacy Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Scientific Series

Laboratory & Pharmacy Refrigerators

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Thermo Scientific Revco Laboratory Refrigerators and Freezers

Ultra-Low Freezer Operation Manual

-86ºC-Freezers. Ultra-low temperature upright freezer -86ºC MDF-U5086W MDF-U6086S MDF-U5186S MDF-U4086S MDF-U3086S MDF-U2086S MDF-U5086W

Controlled Environment Equipment Solutions for the Lab

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Setting the Benchmark

ULTRA LOW TEMPERATURE FREEZERS

Undercounter Refrigerator Operation Manual i.series and Horizon Series

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Biomedical Freezer 37 38

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

MDF-U7586SC MDF-U5586SC. Operating Instructions. Ultra-Low Temperature Freezer MDF-U7586SC

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

DOUBLE DOOR FREEZER.

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Protection, safety, reliability. And more.

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories

Protect your research

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

Undercounter Refrigerator Operation Manual

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

REFRIGERATOR M E D I C A L.

NEW! Thermo Scientific Forma Ultra-Low Temperature Freezers. Ultimate protection Optimum capacity Energy savings. your samples.

Laboratory refrigerators and freezers

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

Upright Chromatography Refrigerators

Ultra Efficient, Earth Friendly, Merchandising Solutions

A look into our complete product collection.

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

Installation and Operation Manual. Thermo Scientific Revco Chest and Upright Ultra-Low Temperature Freezers

A look into our complete product collection.

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

Advance Blood Storage system from Meditech

ULT Freezer Model 5700 Series Chest Freezer Manual Number Rev. 15

TSX Series High-Performance Refrigerators and Freezers

REFRIGERATORS AND FREEZERS. laboratory chromatography ultra low temp pharmacy vaccine hazardous flammable undercounter performance qualified

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

MDF-U333 MDF-U537 MDF-U537D

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

Freeze Dry Systems and Accessories

Digital incubating/ refrigerating benchtop shakers

Ultra-low Temperature Freezer ULT Vault for Your Samples

FreeZone 2.5 Liter Benchtop Freeze Dryers

Ultra-low Temperature Freezer ULT Vault for Your Samples

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

TEMPERATURE FREEZERS -90

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Transcription:

SANYO patented V.I.P. Vacuum Insulation Panel for high density storage Serie V.I.P. Congelatori -86 C F Integrated Ultra-Low Storage Solutions For Biosafety, Security and Performance Tre livelli di sicurezza contro manipolazioni High performance, quiet-running SANYO refrigeration compressors Model MDF-U72VC shown with optional keyless entry system and digital temperature recorder.

The Integrated Solution To Ultra-Low Temperature Storage V.I.P. Upright Freezer Selection MDF-U32V MDF-U52VC MDF-U72VC Temperature Range -50 C to -86 C -50 C to -86 C -50 C to -86 C Interior Volume 12 cu.ft./334 liters 18 cu.ft./518 liters 26 cu.ft./727 liters Area Footprint, Nominal 6.25 sq.ft./0.58m 2 7.24 sq.ft./0.68m 2 9.51 sq.ft./0.88m 2 Electrical, 60Hz 115V, AC 15 amp 208-230V, AC 15 amp 208-230V, AC 15 amp SANYO V.I.P. Keyless Entry System optional optional optional Enhanced Performance And Reliability SANYO V.I.P. Series upright freezers represent the industry's most creative combination of cabinet design, electronics, refrigeration and critical components for enhanced security, better performance, product safety and cost effective operation at -86 C. Stronger Security With Three Levels Of Access Restriction As government and institutional safety guidelines become more aggressive in the wake of global terrorism threats, SANYO products help laboratory managers and clinical investigators comply with emerging rules for access and accountability of stored products. SANYO offers many security features, both standard and optional, to meet a range of inventory access restrictions. The optional keyless entry system includes a tamper-resistant lock activated by a PIN number or key. The smooth operating, Easy-In / Easy-Out outer door latch is designed to be secured with a conventional padlock. A universal keyed door lock prevents the outer door from opening. The SANYO advanced Keyless Entry System enhances the security of stored products by restricting freezer access to authorized personnel only. Entry requires a personal identification number (PIN) or master override key. Factory installed; specify when ordering. The SANYO ergonomic design features Easy-In / Easy-Out door latches that close securely with less power. New SANYO Eagle inner door latches provide single-hand access. The outer door latch closes smoothly with a single-hand action over a cam action bearing. The door can be secured with an independent padlock provided by customer. Inner Doors Improve Uniformity The center shelf forms the base of a convenient and flexible inventory system using conventional racks with boxes, microplates or other storage protocols. Stainless steel shelf and insulated inner-door combinations create choices of interior compartments that can be arranged for long-term, low access biologicals or short-term, frequently accessed material. Easy-In / Easy-Out SANYO Eagle inner door latches feature ergonomic design to seal firmly against the cabinet with one hand. High strength, insulated inner doors help minimize change in interior temperatures during routine door openings. Two inner doors are standard, creating two compartments that can be sub-divided with interior shelves. Multiple inner door configurations available on MDF-U72VC models permit creation of additional compartments. Patented V.I.P. Insulation Increases Interior Volume By As Much As 30% SANYO patented V.I.P. Vacuum Insulation Panel technology and high-tech, thin profile cabinet walls increase interior volume by as much as 30% for high density storage in a minimal cabinet footprint. Cellular wall construction combines vacuum insulation with polyurethane foam for structural stability and highest insulation values while reducing wall thickness by as much as 50% over conventional methods. Outer Cabinet Wall Open Cell Substrate Under Vacuum U.S. Patent No. 6,260,377 Outer Barrier Film Inner Cabinet Wall Closed Cell Foam SANYO patented V.I.P. vacuum panels are formed individually into a unitized composite of panel sections, sealed with reflective barrier film, arranged within the steel inner and outer walls, then pressure laminated with high-density, closed-cell injected foam to form the high technology freezer wall. 2

Microprocessor Controls Compressor start-up delay sequence delays re-start after building power failure; allows facility power to reach equilibrium to permit smooth compressor start-up. Digital display defaults to actual chamber temperature. Display mode changes when setpoint, alarm parameters, programming and diagnostic functions are performed. Status alert function uses predictive intelligence to determine if freezer is operating within specifications under existing environmental conditions. SANYO exclusive Ni-Cad battery powers control memory and alarm functions during power failure. Alarm indicator lamp glows when freezer is in alarm condition; alarm ringback is factory set for 30 minutes, adjustable in 10 minute increments from 10 to 60 minutes. Filter indicator lamp glows when electrostatic filter requires removal for cleaning. Audible alarm. Buzzer silence temporarily mutes audible alarm. Alarm test verifies readiness of alarm function and Ni-Cad battery charge. Setpoint entry advances digital display to next position. Door alarm indicator has 2 minute delay until audible alarm activates; delay time is adjustable. Press to set temperature; set button is also used for other diagnostic functions. Alarm setpoints are factory set 10 o C above and below setpoint. Alarm parameters are adjustable by pressing up or down arrow keys and following the prompt. Setpoint entry advances digital to next value from 0 to 9. The SANYO microprocessor control system is secure, easy to use and comprehensive. Setpoint, alarm parameters and self-diagnostic functions are accessed through a tamper-resistant keypad protocol. Control inputs are managed with convenient push-pad buttons on a unitized, sealed control overlay. The panel is door-mounted and angled for easy access. Alarm And Safety Function Event Visual Audible Signal To Alarm Contact Abnormal ambient (too high or Status Alert too low), or abnormal freezer loading (too much warm product STATUS lamp flashes None None at once) High Temperature Low Temperature Interior chamber warms beyond high temp setpoint Interior chamber cools beyond low temp setpoint ALARM lamp flashes; digital display flashes actual chamber temperature Intermittent tone; time delay of 15 minutes after reaching alarm setpoint avoids false alarms Yes Power Failure Loss of power Intermittent tone Control Temperature Sensor Failure Filter Sensor Failure Sensor probe disconnect, short-circuit or failure ALARM lamp flashes Solid tone No Interstage Refrigeration Sensor Failure Filter Check AutoReturn Clogged or dusty condenser filter Touchpad key is not pressed for 90 seconds FILTER lamp flashes Reverts to chamber temperature display None No Door Alarm Door Open OPEN lamp on Solid tone sounds after 2 minutes (adjustable) Yes 3

Maximum Sample Storage Capacity MDF-U32V MDF-U52VC MDF-U72VC Rack Positions, Standard Configuration 3 columns 4 columns 6 columns 4 rows 4 rows 4 rows Fiberboard Boxes, 2" high (2ml) in SANYO racks 216 352 576 Sample Vials, 2ml (2" box), 100-Cell Dividers 21,600 35,200 57,600 Fiberboard Boxes, 3" high (4ml) in SANYO Racks 144 224 384 Sample Vials, 4ml (3" box), 100-Cell Dividers 14,400 22,400 38,400 Standard Microplate with Foil Tape, in Racks 1296 2112 3456 Standard Microplate with Cover Lid, in Racks 1008 1632 2596 Note: Maximum storage volume varies according to storage vessel, vial configuration, preservation protocol, laboratory technique and user preference. Contact SANYO for detailed information on inventory racks, boxes and storage options. Fully Loaded Inventory Systems Catalog No Catalog No Catalog No Maximum Vial Capacity Includes full quantity of storage racks, boxes and dividers Sliding Drawer Inventory Racks, 2" high boxes (2ml sample) 100-Cell Divider FLI-32-SDR-2S100 FLI-52-SDR-2S100 FLI-72-SDR-2S100 Sliding Drawer Inventory Racks, 3" high boxes (4ml sample) 100-Cell Divider FLI-32-SDR-3S100 FLI-52-SDR-3S100 FLI-72-SDR-3S100 Standard Cellular Inventory Racks, 2" high boxes (2ml sample) 100-Cell Divider FLI-32-SUR-2S100 FLI-52-SUR-2S100 FLI-72-SUR-2S100 Standard Cellular Inventory Racks, 3" high boxes (4ml sample) 100-Cell Divider FLI-32-SUR-3S100 FLI-52-SUR-3S100 FLI-72-SUR-3S100 Individual Storage Rack Systems Catalog No Catalog No Catalog No Sliding Drawer Sample Racks For Fiberboard Storage Boxes (Boxes Not Included) Sliding Drawer Rack, for 2" high (2ml sample) SDR-624-N SDR-624-N boxes; holds 6 boxes high x 4 boxes deep Capacity 8 Capacity 24 Sliding Drawer Rack, for 2" high (2ml sample) SDR-524-N SDR-524-N boxes; holds 5 boxes high x 4 boxes deep Capacity 6 Capacity 8 Sliding Drawer Rack, for 2" high (2ml sample) SDR-424-N boxes; holds 4 boxes high x 4 boxes deep Capacity 6 Sliding Drawer Rack, for 3" high (4ml sample) SDR-434-N SDR-434-N boxes; holds 4 boxes high x 4 boxes deep Capacity 8 Capacity 24 Sliding Drawer Rack, for 3" high (4ml sample) SDR-334-N SDR-334-N boxes; holds 3 boxes high x 4 boxes deep Capacity 12 Capacity 8 Standard Cellular Inventory Racks for Fiberboard Storage Boxes (Boxes Not Included) Inventory Rack for 2" (2ml sample) boxes; SUR-624-N SUR-624-N 6 boxes high x 4 boxes deep Capacity 8 Capacity 24 Inventory Rack for 2" (2ml sample) boxes; SUR-524-N SUR-524-N 5 boxes high x 4 boxes deep Capacity 6 Capacity 8 Inventory Rack for 2" (2ml sample) boxes; SUR-424-N 4 boxes high x 4 boxes deep Capacity 6 Inventory Rack for 3" (4ml sample) boxes; SUR-434-N SUR-434-N 4 boxes high x 4 boxes deep Capacity 8 Capacity 24 Inventory Rack for 3" (4ml sample) boxes; SUR-334-N SUR-334-N 3 boxes high x 4 boxes deep Capacity 12 Capacity 8 Microplate Storage Racks (Plates Not Included) Inventory Rack for microplates, with locking rod; SUMPR-612-LR SUMPR-612-LR SUMPR-612-LR 108 standard plates with cover lid per rack Capacity 6 Capacity 8 Capacity 24 Inventory Rack for microplates, with locking rod; SUMPR-611-LR 96 standard plates with cover lid per rack Capacity 8 Inventory Rack for microplates, with locking rod; SUMPR-616-LR 60 standard plates with cover lid per rack Capacity 6 Fiberboard Storage Boxes and Dividers Catalog No Catalog No Catalog No Inventory Box, 2" high (2ml sample) with 100-Cell Divider B2C-S100 B2C-S100 B2C-S100 Inventory Box, 3" high (4ml sample) with 100-Cell Divider B3C-S100 B3C-S100 B3C-S100 Inventory Box, 2" high (2ml sample) Without Divider B2C B2C B2C Inventory Box, 3" high (4ml sample) Without Divider B3C B3C B3C Box Divider, 81-Cell D81 D81 D81 Box Divider, 64-Cell D64 D64 D64 Sliding Drawer Rack, Catalog No. SDR-624-2S100 shown with 2" (2ml) boxes. SANYO Refrigeration Delivers Uniform Temperature The SANYO cascade refrigeration system uses SANYO-built compressors designed for high-performance, reliability and peace of mind. Refrigeration components are carefully selected and matched for optimum operation under demanding laboratory environments. Interior design with insulated inner doors maintains maximum top-tobottom temperature uniformity at all shelf levels. Increased cooling capacity improves temperature recovery after door openings. Quieter operation is achieved through condenser fan blade design, noise abatement insulation and anti-vibration mounts. Voltage boost and surge protection devices permit dependable operation over wider power ranges and environmental conditions. SANYO is a pioneer in development of consumer products worldwide. As a result, SANYO Electric Biomedical products include many innovative features such as patented vacuum insulation panels, keyless entry systems, quiet-running refrigeration compressors and intuitive microprocessor electronics available through our exclusive Vertical Component Integration program. This powerful corporate technology transfer capability, plus modern robotic manufacturing and quality assurance processes, guarantees that only the very best components are used in each SANYO product. Patented SANYO refrigerants are non-ozone depleting, non-flammable and environmentally safe in compliance with the Montreal Protocol. 4

Integrated Solutions to Ultra-Low Temperature Freezers 1. SANYO patented V.I.P. Vacuum Insulation Panel cabinet construction offers superior insulation with maximum use of interior space. 2. Optional keyless entry system (not shown) enhances security of stored product by restricting access to authorized users only. 3. Easy-In / Easy-Out outer door latch closes smoothly with a single-hand action over a cam action bearing; door can be secured with independent padlock provided by customer. 4. Universal keyed door lock provides additional level of security. 1 5. Microprocessor-based controller includes comprehensive setpoint, alarm, monitoring and diagnostic functions. 6. Remote alarm contacts can be connected to independent monitoring system. 7. Circular chart temperature recorder (optional) installs easily in pre-engineered mounting space. 8. Insulated inner doors help maintain interior temperature during routine openings. Two inner doors, shown, are standard. Multiple inner door configurations for flexible storage options are available; see Accessories. 5 9. Easy-In / Easy-Out SANYO Eagle inner door latches feature ergonomic design to close firmly with one hand. 10. Front access to washable, electrostatic condenser filter for routine condenser air filter cleaning. 11. High impact recessed casters simplify installation. 12. Seismic restraints secure cabinet to building superstructure to meet local codes. 13. SANYO-built compressors specifically designed for low temperature use offer maximum reliability. 14. Multiple access ports permit independent probes, instrumentation or liquid CO2 back-up system inject tubes. 15. Environmentally safe CFC/HCFC-free refrigerants. 16. Internal voltage and power management systems assure component protection and best operation efficiencies. 3 6 12 14 8 9 4 7 13 15 16 10 11 Model MDF-U72VC offers large volume storage, multiple security systems, high performance refrigeration and microprocessor-based controller for comprehensive storage solutions in research, pharmaceutical, clinical and industrial applications. The optional Digital Temperature Recorder* mounts on the cabinet door. The recorder is programmable to capture and store non-corruptible data points for downloading to an independent data management system to meet criteria outline in U.S. FDA 21 CFR Part 11 directives. An independent probe is placed in the chamber interior. Digital Recorder meets US FDA 21CFR Part II Criteria For Electronic Records * Manufactured by Elpro, Switzerland

Model And Specification Patented V.I.P. Cabinet Construction Insulated Inner Door Inner Door Configuration, Standard Door Gaskets Condenser Filter, Easy Cleaning Rounded Interior Corners Shelf Brackets Casters Seismic Restraints Access Ports steel-framed, high impact plastic with foamed-in-place insulation two multi-point compression gaskets electrostatic filter standard, front accessile for easy access, no tools required simplify cleaning incrementally adjustable high-impact multi-wheel standard; hard connection to facility wall multiple ports allow use of injection tubes, probes, leads, instrumentation The MDF-U72VC includes two inner doors, standard. Easy-In / Easy-Out inner doors are available in half sets of two, permitting partitioning of interior. Two smaller doors per set. For four-door configuration order two sets. Catalog No. MDF-72ID Quantity Required: 1 1 2 General Specification MDF-U32V MDF-U52VC MDF-U72VC Temperature Range (Ambient 30 C) -50 C to -86 C -50 C to -86 C -50 C to -86 C Interior Volume 12 cu.ft./334 liters 18 cu.ft./518 liters 26 cu.ft./727 liters Area Footprint, Nominal 6.25 sq.ft./0.58m2 7.24 sq.ft./0.68m2 9.51 sq.ft./0.88m2 Dimensions and Weights Interior 19.3"W x 23.6"D x 44.9"H 24.8"W x 23.6"D x 54.3"H 34.25"W x 23.6"D x 55.1"H 490mm x 599mm x 1140mm 629mm x 599mm x 1379mm 869mm x 599mm x 1399mm Exterior 26.4"W x 34.1"D x 73.2"H 30.3"W x 34.4"D x 78.3"H 39.8"W x 34.4"D x 79.1"H 670mm x 866mm x 1859mm 769mm x 873mm x 1988mm 1010mm x 873mm x 2009mm Net Weight, Empty 569 lbs/258kg 660 lbs/299kg 750 lbs/340kg Refrigeration System, CFC/HCFC-Free Refrigerants High Stage Compressor 1/2 HP 1 HP 1 1/2 HP Low Stage Compressor 3/4 HP 1 1/2 HP 1 1/2 HP Built-In Voltage Booster N/A standard standard Sound Abatement standard standard standard Electrical Single Phase AC Power 115V, 60Hz 208-230V, 60Hz 208-230V, 60Hz Recommended Breaker 15 amp 15 amp 15 amp NEMA Plug Reference 5-15P 6-15P 6-15P NEMA Receptacle Required 5-15R 6-15R 6-15R Cabinet Accessories Keyless Entry System Digital Temperature Recorder Liquid CO2 Back-Up System Liquid Nitrogen Back-Up System Chart Recorder Chart Paper Replacement Pen Interlocking system with numeric pad, locking mechanism, hardware and override key. Factory installed; specify when ordering. Catalog No. MDF-7DL Hamster digital temperature recorder. Fully programmable. Includes software. Catalog No. Hamster ET2 Factory installed; specify when ordering. Catalog No. CVK-UB2(I) Factory Installed; specify when ordering. Catalog No. CVK-UBN2 Factory installed; specify when ordering. Circular chart. For Model MDF-U32V, Catalog No. MTR-G85A. For Models MDF-U52VC, MDF-U72VC, Catalog No. MTR-G85C Package of 50 charts. Catalog No. RP-G85 Catalog No. PG-R SANYO V.I.P. Series freezers offer high-density storage that effectively reduces the volumetric unit costs of lowtemperature freezers. SANYO Electric Biomedical Co., Ltd., as a member of SANYO Electric Group, has received ISO9001 and ISO14001 Certification for its environmental management system. SANYO products are built to meet Entela criteria for product safety and performance. SANYO Sales and Supply Company 1062 Thorndale Avenue Bensenville, IL 60106 USA Toll-Free USA 800-858-8442 Fax 630-238-0074 www.sanyobiomedical.com SANYO Canada, Ltd. 300 Applewood Crescent Concord, Ontario L4K 5C7 416-889-3107 Fax 416-889-3117 CO2 And Multi-Gas Incubators Cryogenic and Ultra-Low Temperature Freezers Lab Freezers and Refrigerators Autoclaves SANYO 2004 Specifications subject to change without notice. V.I.P. is a registered trademark of SANYO. OW6971 V.I.P.32/52/72 USA 4/04