Do you know the three blind spots of traditional aspirating smoke detector system?

Similar documents
Series Internal Detector

Seismic Countermeasures for Environmental Radiation Monitoring System

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Bionics Instrument. Alarm Handling. Gas Alarm Systems

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Class 1 laser beam sensor safe for your eyes

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

Infrared Moisture Determination Balance FD-610. Operating Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

D-TEK -MS Vehicle Loop Detector. Operating Instructions

Danfoss gas detection units

TrueAlarm ES Analog Sensing

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

MR SERIES CARD LOGGERS

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

ENGINEERED PARKING SYSTEMS MODEL 3416D

Power Supply Display Module PSDM. Installation and Operation Manual

LifeAlarm Fire Alarm Controls

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Instruction Manual. Digital Recorder. Model SDR-304. Make sure all the accessories are supplied together. Introduction Connection. Operation.

APPLICATION DATA SHEET

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

QA16 Addressable System

TrueAlarm Analog Sensing

APPLICATION DATA SHEET

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Remote alarm indicator and test combination MK2430

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

LD-5000 REFRIGERANT LEAK DETECTOR

Advanced Ultraviolet Burner Controller

TrueAlarm Analog Sensing

Thermoelectric Bath. Series HEB

ACCURATE ELECTRONICS INC

Danfoss gas detection units

Flexible Air-sampling Smoke Detection

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

FLAME SENSOR FS-2000E

P2267 NETWORK INTERFACE

SMS GSM Alarm Messenger

Pioneer-R16 Gas Monitor Operator s Manual

TrueAlert Addressable Notification

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Thermoelectric Bath. Series HEB

HOST SERVER CRITICAL INFRASTRUCTURE & ENVIRONMENTAL MONITORING SYSTEM DATA CENTER PLANT BASE STATION. Generator Fuel Level. Battery Monitoring

Installation Guide: PowerAire Quad

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

VD 53 - Vacuum drying oven for non-flammable solvents

Specification/ Data Sheet

Buzzer Unit. TAN-5000 Series. Operating Manual

System Accessories, LCD Annunciators

COMMUNICATOR ET08 / ET081

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

INSTRUCTION MANUAL RM AM/FM Digital Alarm Clock Radio

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Part 3 Troubleshooting

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

Metasys Integrator Compu-Aire Application

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Multi-Point Peripherals

LifeAlarm Fire Alarm Control Panels

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

RIELLO 40 GS/M SERIES

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

TrueAlarm Analog Sensing

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Fire Alarm System Accessories

OIL FILM DETECTOR (Long-distance correspondence Version)

M004 combustible gas module

Frequently asked questions: Intelligent Transmitter Series

RACK MONITORING SYSTEM - RAMOS Ultra

MBCE-110/230UV Flame Sensor Module

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Fire Control/Communicator

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

General Specifications

XLH210: controller for gas leak detectors

JK e-solutions ApS FS12. Control and Monitoring system for Fixed Aerosol Fire Extinguishing Systems. Installation and Service Manual R11

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

USER MANUAL FOR OPERATING SYSTEM

Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

OVEN INDUSTRIES, INC.

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Vacuum drying oven for non-flammable solvents

Transcription:

Sensitive smoke detector UL-approved ( File No. S25270 ) Do you know the three blind spots of traditional aspirating smoke detector system? ❶ Smoke area unspecifiable due to collective aspiration from suction pipe. ❷ True detection impossible due to smoke dilution in suction pipe. ❸ Slow detection if suction area and control unit are distant. Aspirating smoke detector Smoke suction pipe Detection Sensor Line of Power & data transmission Air circulation Smoke flow Smoke concentration data transmission We provide you with the best solution.

An ultimate sensitive smoke detector system realized by Fenwal Controls of Japan, Ltd. Suction Alarm System:The smoke area can be specified quickly because of the smoke detector module which has set addresses. Advanced sensitive smoke detector & control unit with built-in suction fan Alarm address display the pre-alarm and alarm is quickly sounded according to the set level. It demonstrates its effect when set it in places where smoke emission may occur such as power supply devices or running gears. Inside server rack Power supply devices in factory Semiconductor test equipment FA production line robot running gear

which has a track record with its disaster prevention system for large facilities and factories in the industrial world. Settings examples The SAS (Suction Alarm System) enables appropriate placement of detector that suit site condition and building structure. Direct method Detection module Abnormalities can be identified with instantaneous detections even in large spaces since each detector aspirates smoke. Semiconductor test equipment FA line Communication equipment room Radio broadcast place Food manufacturing line, etc. Tube method Detection module It is possible to extend a tube from the detector and precisely detect any abnormalities even with closely divided powered equipment in cubicles. Distribution board Server Power supply unit, etc.

By connecting with a computer, the situation can be fully grasped from the monitoring room. 1 Trend graph display features Trend graph which displays time series data of smoke concentration variation, can be displayed about each address. 4 Condition display features Current conditions of each address can be displayed so that a user can check alarm levels and troubles etc. 2 Alarm/pre-alarm setting up function Up to 31 detectors are connectable to a control unit. Each address can be set alarm and prealarm level. 5 Control unit setting up function Upper/lower value of air flow, and number of detectors to connect can be set to a receiver. Further, system reset operation can be made. 3 History reporting features In total 1,023 of history data can be displayed and printed as a list. 6 Alarm signal reception display features (option) Address of detected modules and located places can be displayed on a layout drawing.

Detectors accurately detect the smoke area / condition. Traditional sampling method blind spots (E.g.) In a traditional system with a 0.1%/m sensitive smoke detector with 30 suction sockets Blind spot 1 Detection is impossible even if aspirated smoke has an above threshold concentration due to smoke dilution in suction tube. Even if concentrated smoke is aspirated, it is diluted before detection. Consequently, its concentration does not reach the threshold, and thus not detected. Even if 2%/m of concentrated smoke is aspired from the 30th socket, not only will the emission area not be specified, but, if the smoke flow from other sockets is equivalent to zero, the smoke concentration in the detector part will become 0.07%/m, and thus not be detected. Blind spot 2 Correct detection is impossible due to aspirated smoke being diluted in suction tube. Even if aspired smoke concentrations from a wide area reaches the threshold, the slightest dilution will render it to become undetectable. It will work if the 30 suction sockets aspirate a 0.1%/m concentrated smoke. However, if one of those sockets presents a smoke flow equivalent to zero, the smoke concentration in the detector part will decrease to 0.09%/m, and thus will not be detected. Blind spot 3 Smoke area will be unspecifiable and detection time will vary according to suction point with several suction sockets (our prior products). Even if smoke is detected, the source of emission cannot be specified. Detection time will vary according to suction point. Suction Alarm System g A sensitive smoke detection system that solves prior problems It is not influenced by smoke concentration inside suction sockets Detection module 2 3 1 1 By setting individual addresses for the smoke detector modules, it is possible to specify the smoke area. 2 It is possible to set the sensitivity of each detector module within a range of 0.1%m to 3% of smoke concentration. 3 Cause each module will detect, time difference due to distance will not occur.

Aspirating Smoke Detector : SAS11- QY01-UL Classification Aspirating Smoke Detector Rated voltage DC24V 1.0mA Working voltage range DC24V ± 10% Current consumption 0.9mA or less (When DC24V is applied) Red LED Electrical Specification Monitoring state : Blinks once in 10 seconds Status indicator Alarm state : Blinks once in 2 seconds Trouble state : Lights out Restoration Alarm indication is self-maintaining(reset from Aspirating Control Unit SASC1-Y ) Range of alarm level 0.1%/m to 3%/m ( in 0.05% increments ) Address Address set for each detector (Address settings 01 ~ 63) Operating temperature range 0 to 37.8 Environmental Storage temperature range -20 to 70 Operating humidity range 30 to 85% RH (However, no condensation) Main material ABS(UL 94V-0) Mechanical Weight Approximately 180g Enclosure dimensions Height 100mm Width 102mm Depth 62mm Aspirating Control Unit : SASC1- Y-UL Classification Electrical Specification Environmental Mechanical of the UL certification Standard Category UL File No. Aspirating Control Unit Rated voltage AC100V 50/60Hz 80W Working voltage range AC 90 V to AC 240 V Connectable detector Number Up to 31 External wiring resistance 10 Ω or less (two way between receiving panel and detector) Typical from C Dry contact : Alarm, Pre-alarm, Trouble, Power interruption Contact output Typical from A Dry contact : Alarm Contact capacity:dc24v 1A Alarm Electric buzzer : Continuous ringing with alarm Intermittent ringing during trouble or pre-alarm Operation Transmission stop, sound stop, system reset External I/F RS-232C Port 1 Channel (D-Sub 9pin male) Operating temperature range 0 to37.8 Storage temperature range -20 to 70 Operating humidity range 30 to 85% RH (However, no condensation) Main material SPCC t = 1.2mm Weight Approximately 4.1kg Enclosure dimensions Height 170mm Width 260mm Depth 120mm UL268 Smoke Detector for Special Application (Code: URXG) S25270 Aspirating smoke detector module dimensional diagram Aspirating control unit dimensional diagram 170 (33) Grommet for PC line 39.5 (64) 25A pipe 159 4-M3 Threaded holes for mounting a mute box 70 15 260 120 Construction material Material Size Pipe Recommendation Rigid PVC pipe (VP pipe) 25A Color: White Type: Air conditioner drain pipe Wiring Type Maximum wire length Recommendation * Appearance and specifications are subject to change without any prior notice. Unauthorized duplication of the contents is strictly prohibited. * Catalog content is current as of July 2015. Shielded cable 1P 150m Adapted standard: J CS 5402 Color: White Product: F CPEV-NC cable 0.65mm X 1P made by Nihon Electric Wire & Cable Co., Ltd. http://www. fenwal. co. jp Head Office / Tokyo Business Office : Kyohan Kudan Building, 1-5-10 Iidabashi, Chiyoda Ward, Tokyo JAPAN 102-0072 Phone: +81-3-3237-3565 Fax: +81-3-3237-3569 PE-821A 2015-07-24 OYK