Business Hand dryer High Speed

Similar documents
Business². Hand dryer. High Speed

Business² Hand dryer

Executive. Hand dryer. High Speed

Eco. Hand dryer. Automatic. High Speed

Biobot Hand dryer. Automatic. High Speed

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

The Complete Range of Hand Dryers

HAND DRYERS

Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

Hand Dryer Installation & User Manual

OC Series - Automatic coffee machines. OLC1 Lucia High performance liquid coffee dispenser. Users Handbook - 1 -

^ Blade Hand Dryer Model: GS-2006H SLV

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

TSL hand dryer. installation + maintenance

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

INSTRUCTION MANUAL Model: SU3022

IMPORTANT SAFETY INSTRUCTIONS:

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

Electric Hand dryer. Installation and operating manual

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Dehumidifier. Instruction Manual. Model DH-320/A

I N S T R U C T I O N S

WASHROOM. Solutions Super fast, super efficient... UK market leaders in washroom solutions for over 45 years.

Hand Dryers Air Curtains Soap & Paper Dispensers Foam Dispenser Sanitizer Dispenser Body & Hair Dryers Shoe Shining Machines Sensor Taps & Urinal

Steam Mop with Foldable Handle 1500W

INSTALLATION INSTRUCTION for ceiling fan

T1 SCRUBBER DRYER OPERATOR MANUAL

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

IMPORTANT INSTRUCTIONS READ & SAVE

BARDON ROUGHING-IN. A. Specifications A T01-D TOUCHLESS HAND DRYER INSTALLATION INSTRUCTIONS K-5486T

IMPORTANT INSTRUCTIONS READ & SAVE

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDELINES

ConserveWell DROP-IN UNIT

INSTANT HOT WATER DISPENSER

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

You could never call a hand dryer beautiful, but we have made every effort to build something pleasing on the eye that works on all levels

PRE INSTALLATION PROCEDURES

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

HS&S Alert No: 103 Date: 9 March 2017

IMPORTANT INSTRUCTIONS READ & SAVE

1600 Watt Professional

Hot Chocolate Dispenser

Installation & Operating Instructions

PROZONE INSTALLATION AND OPERATING INSTRUCTIONS FOR UK-PR ISS-B

TOEPIA LX ARMREST ASSEMBLY INSTRUCTION

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

IMPORTANT SAFETY INSTRUCTIONS

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

A few simple steps to ensure perfect water, every time.

IMPORTANT SAFETY INSTRUCTIONS:

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

IMPORTANT INSTRUCTIONS READ & SAVE

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

OPERATION AND INSTALLATION

A few simple steps to ensure perfect water, every time.

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

MODEL 7000 SUCTION UNIT

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

Arctic EVAPORATIVE COOLER USER MANUAL

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

Electric Digital Kettle

Slimline, Energy Saving & Smart. It's the game changer!

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

5) Do not start or stop the unit by inserting or pulling out the power plug.

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

CI/SfB (57.7) 1st Edition. Vent-Axia Hygiene Range

Syrup Server. Thank You MODEL: SY MODEL: SY for purchasing this Syrup Server to heat and neatly dispense sticky syrups and sauces.

User, Installation and Servicing Instructions. Panther Static Hot Cupboards G1, G2 and G3 IS86 ECN1881

TECHNICAL, ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

11. Please follow cleaning instructions carefully so as to avoid injury or damage. 12. Should the Fan or protection fuse fail to work properly, turn

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

ULTRASONIC HUMIDIFIER

A few simple steps to ensure perfect water, every time.

5KEK1222A W A_v05.indd 1 7/10/15 1:20 PM

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

Meaco 20L medium home dehumidifier Instruction Manual. nergybulbs.co.uk. Meaco 20L Medium Home Dehumidifier

4L Instant Water Boiler Instructions for Use

Water Distillation System Instruction Manual Nutriteam TC-501

Installation & Operating Guide

B.I.C.A Built-In Coffee Appliance

SHOWER COLUMN WITH RAIN HEAD

INSTRUCTIONS AND WARRANTY

PANTHER. Condensate removal pump Installation and operating guide

Owner s Manual. Operating Instructions The Controls on Your Dehumidifier Care of Product

Installation & Operating Guide

Transcription:

Business Hand dryer High Speed 1

292mm 650mm 250mm Item Category Operating Voltage Warm Air Speed Output Display Motor Type Motor Thermal Protection Heater Element Heater Thermal Protection Drying Time Circuit Operation Timing Protection Drip Proof Isolation Decebel Rating Net Weight Shipping Weight Unit Size Item Code BB70W BB70S Technical Specifications Performance Data 220-240Vac, 50 Hz, 850 WATTS 95 m/s (220m³/h) LCD instructions and countdown 18,000 rpm, ICP Brushless DC Auto Resetting Thermostat turns unit off, 240V at 221 F (105 C) - EURO Spec Not Applicable Not Applicable Under 10 seconds Infared Automatic, self adjusting 30 seconds auto shut off IP22 CLASS I 78 dba@ 1 mtr 11 kg 13 kg 292mm W x 650mm H x 250mm D Cover Type/Finish ABS White ABS Metallic silver 2 Business

General Safety Information WARNING This product is intended for installation by a qualified service person. Use AWAG No.16 solid conductor for wiring. Failure to properly ground unit could result in electrical shock and/or death. Disconnect power at the service breaker before installing or servicing. NOT FOR HOUSEHOLD USE - MAY CAUSE BURNS IMPROPRE A L USAGE DOMESTIQUE - PUET OCCASIONNER. NOTE: Do not install dryer over wash basin. Type Y attachment If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. All units must be supplied with a 2-wire service. The ground wire must be connected with the dryers back plate. Installation Installation must be carried out only by a qualified electrician 1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electrician. 2. Place template against wall at desired height (see mounting height recommendations) and mark locations of 4 mounting holes and wire service entry at knockout (KO) location. Connections: a. Connect the live wire (coloured red or brown) to the terminal block marked L. b. Connect the neutral wire (coloured black or blue) to the terminal block marked N. Note that the colour of live and neutral wires depends on voltage of supply service. 5. Replace cover screens. Do not over-tighten. NOTE: For two or more dryers, dryers should be no closer than 24 inches (610 mm) on centre. 3. Remove and retain 2 cover screws. 4. Connect supply wires to terminal block where indicated and connect ground wire to baseplate with ground screw. Business 3

Recommended Mounting Heights From floor to bottom of dryer. Men s Ladies Children, ages 11-17 Children, ages 3-10 Disabled 13 11 10 6 4 350 mm 300 mm 250 mm 150 mm 100 mm Consumables Biodrier Anti Bacterial Filter The Anti Bacterial Filter is fitted to ensure dust and airborne bacterias are restricted from entering the internal components and airflow of the dryer. The filter should be replaced every 3-6 months, depending on usage. Product Order Code Antibacterial filter HDS-BB70 Moisturising Gel HDC-BIO GELS TUB 24 Biodrier Gels Biodrier Gels are manufactured exclusively for Biodrier and preforms 3 jobs in one: 1. Moisturise the hands. 2. Sanitise the product internally, and the users hands. 3. Fragrances the surrounding washroom area whilst in use. The Gels are manufactured from natural sources and are chemical free. Operation No touch operation. Shake excess water from hands. Place hands onto the aperture. Move hands up and down (as per CPU instruction). Stops automatically after hands are removed. 4 Business

Cleaning and Maintenance Instructions Periodic cleaning of the unit is recommended to ensure optimum performance. Switch to service mode located on the top right side of the dryer. Wipe the cover with a soft cloth and a mild cleaning solution. Do not Soak. Never use abrasives to clean the cover. WARNING Never spray water directly onto hand dryer Never use any abrasives or harsh chemicals Turn off electricity prior to cleaning the hand dryer 5. Disassemble drain tank and rinse clean using a disinfectant, then replace. e. 6. Wipe down the external surfaces of the Biodrier Business hand dryer with a soft cloth. Switch power back on and test operation. 1. Pour a cup of water down drain hole. Use cleaning brush supplied to clean drain hole. 4. Clean filter casing by wiping with soft damp cloth. Replace the antibacterial filter every 3 months. Moisturising gels should be replaced every month. Slide filter back into place. 2. Remove drain tank and empty. 3. Remove filter. Business 5

Diagram 6 Business

Parts List Key Description 1 Water tank 2 Cover 3 Filter 4 Air inlet 5 Motor cover 6 Front cover 7 motor and air home 8 Sound insulation cover 9 Fixer 10 Circuitry A 11 Connection converter 12 motor cover 13 Front air out cover 14 Circuitry C 15 Bracket 16 Connector 17 Front air shell 18 Front airproof 19 Circuitry D 20 Plus screw 21 Back screen 22 Bracket 23 Circuitry E 24 Circuitry F 25 LCD dashboard 26 Bracket 27 Bis pothook 28 Back board 29 Back air cover 30 Circuitry G 31 Light box 32 Circuitry H 33 Back airproof 34 Connected board B 35 Fixing board 36 Small pothook 37 Plus screw 38 Spring 39 Spring fixed cover 40 Main body 41 Mica board 42 Hose 43 Outlet rubber 44 Celotex A 45 Block Spring 46 Sideboard 47 Circuitry box 48 Circuitry B 49 Fix loop 50 Air connector 51 Nut 52 Switch 53 Switch button Business 7

FW3 LTD, Biodrier West Hill, Exeter, EX11 1LQ tel: +44(0)1404 814292 email: sales@biodrier.com