Biobot Hand dryer. Automatic. High Speed

Similar documents
Eco. Hand dryer. Automatic. High Speed

Business² Hand dryer

Business Hand dryer High Speed

Business². Hand dryer. High Speed

Executive. Hand dryer. High Speed

The Complete Range of Hand Dryers

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

HAND DRYERS

TSL hand dryer. installation + maintenance

Hot Air Hand Dryer Range

BARDON ROUGHING-IN. A. Specifications A T01-D TOUCHLESS HAND DRYER INSTALLATION INSTRUCTIONS K-5486T

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

18 INCH HIGH VELOCITY FLOOR FAN

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT INSTRUCTIONS READ & SAVE

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

INSTALLATION INSTRUCTIONS

24 & 30 INCH DRUM FANS

150MM ELECTRIC EARTH BORER

IMPORTANT INSTRUCTIONS READ & SAVE

OPERATION AND INSTALLATION

WAILEA OWNER S MANUAL

INSTALLATION INSTRUCTION for ceiling fan

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Hand Dryers Air Curtains Soap & Paper Dispensers Foam Dispenser Sanitizer Dispenser Body & Hair Dryers Shoe Shining Machines Sensor Taps & Urinal

IMPORTANT INSTRUCTIONS READ & SAVE

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

Condensing Units CUS 15-60

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

ASHDOWN STOVE SUITE

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4

CEILING FAN OWNER'S MANUAL

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

NON-SUBMERSIBLE WATER PUMP

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

OPERATING INSTRUCTIONS

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Comfort. Description. Applications

Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

Chest Freezer Instruction manual

RESIN FREESTANDING TUB

Viking Installation Guide

GCW SERIES Gas Cylinder Warmers

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

AM 213 Installation Introduction

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL (ATEX / IECEx)

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

IMPORTANT INSTRUCTIONS READ & SAVE

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

CEILING FAN OWNER'S MANUAL

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Insta-Therm Series Service, Installation and Operation Manual

e Bath Fan with Light User s Guide

Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

IMPORTANT INSTRUCTIONS READ & SAVE

15-Year Limited Warranty

Model: AC-108. Instruction Manual

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

TABLE OF CONTENTS FOR YOUR SAFETY

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

The Arden Oscillating Floor Fan

Cabinet Refrigerators/Freezers Instruction manual

THE VELOCITY PATTERN

T1 SCRUBBER DRYER OPERATOR MANUAL

CEILING FAN OWNER'S MANUAL

The Finest Hand And Hair Dryers Available

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

B SERIES ELECTRIC FURNACE

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

Installation. 3 Series Built-In Electric Cooktop RVEC330 / CRVEC330 RVEC336 / CRVEC336 RVEC345 / CRVEC345

SECTION ELECTRIC HAND DRYERS. ** NOTE TO SPECIFIER ** Excel Dryer, Inc.; Electric Hand Dryers.

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Spiral Dough Mixer. Instruction manual. Model: CP821

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

Installation and Instruction Manual

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

ECOLEC PANEL HEATERS GENERAL NOTES.

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

Transcription:

Hand dryer Automatic High Speed

Surface Mounted High Speed Hand Dryer 300mm 175mm 280mm Item Category Operating Voltage Warm Air Speed Output Air Output Temperature Motor Type Motor Thermal Protection Heater Element Heater Thermal Protection Drying Time Decibel Rating Circuit Operation Sensor Range Timing Protection Drip Proof Technical Specifications Performance Data 220-240Vac, 50Hz, 900 WATTS 64 m/s, 140m³/h 77 F (25 C) - Ambient Temperature 68 F (20 C) 23,000 rpm, 650W, Brush Type, Dual Ball Bearings Auto Resetting Thermostat turns unit off, 240V at 221 F (105 C) - EURO Spec 250W Auto Resetting Thermostat turns unit off at, 149 F (65 C) Under 10 seconds 76 dba @ 1mtr Infared Automatic, self adjusting 100 mm 60 seconds auto shut off IP22 Isolation CLASS 1 Net Weight 4.5 kg Shipping Weight 5 kg Unit Size 280mm W x 300mm H x 175mm D Approvals CE, WEEE, Greenspec Item Code Cover Type/Finish BB08 Die Cast Aluminium; Epoxy Polyester Powder Coating (Blue) 1

Surface Mounted High Speed Hand Dryer General Safety Information WARNING Failure to properly ground unit could result in electrical shock and/or death. This product is intended for installation by a qualified service person. Use AWAG No.16 solid conductor for wiring. Disconnect power at the service breaker before installing or servicing. NOT FOR HOUSEHOLD USE - MAY CAUSE BURNS IMPROPRE A L USAGE DOMESTIQUE - PUET OCCASIONNER. NOTE: Do not install dryer over wash basin. Type Y attachment If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. All units must be supplied with a 3-wire service. The ground wire must be connected with the dryers back plate. Installation Installation must be carried out only by a qualified electrician 1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electrician. 2. Place template against wall at desired height (see mounting height recommendations) and mark locations of 4 mounting holes and wire service entry at knockout (KO) location. NOTE: For two or more dryers, dryers should be no closer than 24 inches (610 mm) on centre. Connections: a. Connect the live wire (coloured red or brown) to the terminal block marked L. b. Connect the neutral wire (coloured black or blue) to the terminal block marked N. c. Connect the ground wire (coloured green or green and yellow) to the green screw marked. Note that the colour of live and neutral wires depends on voltage of supply service. 5. Replace cover. Do not over-tighten screws. 3. Remove and retain 2 cover screws and cover. 4. Connect supply wires to terminal block where indicated and connect ground wire to baseplate with ground screw. 2

Surface Mounted High Speed Hand Dryer Recommended Mounting Heights From floor to bottom of dryer unit. Children, ages 3-9 Children, ages 10+ 33 39 84cm 99 cm 560mm 530mm 410mm 3-9 years: 840mm 10+ years: 990mm 1010mm 710mm 3-9 years: 840mm 10+ years: 990mm 840mm FLOOR LEVEL 3

Surface Mounted High Speed Hand Dryer Operation No touch operation. Shake excess water from hands. Place hands under the outlet to start operation. Rub hands lightly and rapidly. Stops automatically after hands are removed. Cleaning and Maintenance All surfaces of the unit should be cleaned daily with a soft cloth dampened with warm, soapy water. Polish with a soft dry cloth. DO NOT use caustic solutions or abrasive cleaning materials on the drier. Resources For more information including preformance data, the blog and Make Your Own worksheets visit: www.biodrier.com 4

Eco Surface Mounted High Speed Hand Dryer Diagram and Parts List Key Description 1 Die Cast Cover 2 Motor Housing 3 Rubber Washer 4 Shock Absorber 5 Motor Rubber 6 Rubber 7 Blower Housing 8 Blower Mounting Plate 9 Mounting Plate Screws 10 Electrical Terminal Block 11 Cable Clamp Key Description 12 Cover Screws 13 Nylon Bushes 14 Base Plate 15 Circuit Board Module 16 Circuit Board Cover 17 Heater Element 18 Baffle Plate 19 Air Outlet /baffle 20 Senor Bracket 21 Sensor Module 22 Sensor Screen 5

Eco Surface Mounted High Speed Hand Dryer Installation Template 6

FW3 LTD, Biodrier Unit 3, Woodlands Business Park, Burlescombe, Devon, EX16 7LL tel: +44(0)1823 672 970 email: sales@biodrier.com