SmartAlarm Annunciator

Similar documents
Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

725B Configuration Software Manual

DRAFT 20 October 2014

APPLICATION DATA SHEET

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Frequently asked questions: Intelligent Transmitter Series

ZXSe Range Data Sheet

SIL725 Safety Annunciator

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

System 9000TS Sequence of Events Recorder

Panel Mounted Fault Annunciator Series

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

System 9000TS Event Recorder

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Panel Mounted Fault Annunciator Series

AIS750 Series Alarm Annunciator

APPLICATION DATA SHEET

Passive infrared ceiling sensor

FAAST. Fire Alarm Aspirating Sensing Technology

Monitoring Solutions

Gas Controller Module GC-06

Di-440 The Modular Analyser

Advanced FireAlarm Panel 1-4Loop

Window facia fault annunciators

Universal fault annunciator for panel mounting

Series 725 Programmable Alarm Annunciator

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Controllers, Indicators & Set Point Programmers

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Reliably Advanced Extinguishing Control

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

MICROPOINT to MICROPOINT II UPGRADE

WG Buried Cable Perimeter Detection System

C-Bus Four Channel General Input Unit Installation Instructions

Reliably Advanced Extinguishing Control

FAAST. Fire Alarm Aspirating Sensing Technology

Arc Fault Protection System D1000

D1000 Arc-fault Protection System

SUPREMATouch. Modular Fire & Gas Detection System

TER Active Room Temperature Sensor (Controller),

FDA241, FDA221 Siemens ASD

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

SUPREMATouch. Modular Fire & Gas Detection System

Touch Screen 1 loop Addressable Fire Alarm Panel

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Vocia VACIE. Reference Guide

FDA241, FDA221 Siemens ASD

Altanium Temperature Controllers

Safety control unit 471 M41 H31. for 4 to 32 sensors, with safety and control outputs. Use. Models. + PLe according to EN ISO

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Industrial Grade Gas Detection Detecting The Difference

VACIE REFERENCE GUIDE REVISION 1.2.6

Parameterisable compact fault annunciator with permanent display

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

VERSO Air Handling Units

SC-F3G User Manual 1.0

HART XL High Sensitivity Smoke Detection

Control and Annunciator Panels. Compact systems of signalling and control

HART XL High Sensitivity Smoke Detection

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

Complete packages with Software and Controller

Ronan Model X96S Series Density System

Model A1600 Series Annunciator

FG Wilson Control Systems

Panel Mounted Fault Annunciator Series

Engineering Guideline. pac- Carriers Type Universal

21-light Remote Annunciator. Owner s Manual

ESP TECHNOLOGIES LIMITED

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Flopurge TS. Operation Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Complex alarming made simple

M210 Multifunction Micro OTDR

T5000 LCD Digital Fan Coil Thermostat

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Model A1700 Series Annunciator

SECTION LOW VOLTAGE LIGHTING CONTROLS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

/8 DIN Level Indicator

VERSO Air Handling Units

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

VIBstudio is an intelligent platform for online condition monitoring, failure protection and vibration-based diagnostics of machinery.

Clino Guard. Safety without Compromise

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

NU2 Smart Power Supply (SPS) Manual

EL-OEM-3 OEM Packaged Voltage Data Logger

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

EasyAlarm ELEVATOR LEITRONIC AG

Transcription:

Annunciator Specification/Features

The Annunciator offers a modern compact DIN package that includes state of the art critical alarm capture in an industry standard footprint

1. High Intensity LED s 2. Legend windows customer accessible 3. Front Panel USB access 4. IP rated pushbuttons 5. PSU and watchdog diagnostic LED s 6. GUI diagnostics 7. Two part Lockable connectors 8. Integral repeat relays 9. Integral power supplies 10. Secure panel fixing 5 6 7 1 2 3 10 4 9 8 Flexible Options in a fully Certified CULUS package 3

1 High Intensity LED s Aesthetically designed front panel with easy accessible LED s Alarm priorities through LED colour Front accessible pluggable LED s Wide viewing angle Provides instant discrimination on critical alarms Allows easy change out of colour priority and maintenance Ensures alarms are viewable from any point in the CCR Instant visualisation for critical alarm identification 4

2 Customer accessible legend pocket One method, many languages Custom printing of alarm legends Easily fitted legend label Printable on readily available standard acetate Ensures accurate data for local languages reducing translation issues Eight alarm legends can be changed in one quick process no tools required Standard acetate printing stock is used to ensure world-wide availability Built in flexibility for displaying alarm legends 5

3 Front accessible USB Port Quick connectivity to access parameter configuration IP54 rated USB plug Standard USB Mini type B connection Instant parameter change feedback via free configuration tool Ensures front panel IP rating is maintained in harsh environments No special tools or connectors are required so standard USB cables can be used All changes to parameters can be viewed via the Configuration tool GUI interface. Front accessible USB Socket for easy commissioning 6

4 IP54 Rated Pushbuttons Integrity protection to IP54 IP54 rated tactile feedback pushbuttons Pushbutton enable/disable via software configuration Pushbutton calibration mode No additional protection required when using the IP54 kit Pushbuttons can be disabled to ensure invalid controls are not activated Basic parameters can be changed without the need to connect a PC including comms testing Soft addressable pushbuttons as standard 7

5 PSU and Watchdog Diagnostic LED s Visual indication of system status Two high profile LEDs for power monitoring Watchdog indication Watchdog function can be mapped to common relay Quick indication of power supply status Provides indication of supply failure or communications and status Allows remote monitoring via third party device Ensures minimum downtime for critical alarms 8

6 GUI Diagnostics Provides dynamic status Free GUI Software Intuitive software Dynamic monitoring No need to purchase expensive tools No need of expert knowledge to commission Real time indication of equipment status Powerful diagnostic in an affordable package 9

7 Two part lockable connectors Provide secure connectivity Two part connector Includes lockable screw fastening Accepts 2.5m 2 cable in a rising clamp Allows easy connection to the customer panel Secures the connector halves to ensure vibration cannot disconnect a channel 2.5m2 aperture accepts tri-rated cables Designed to ease installation in modern control rooms 10

8 Integral repeat relays Retransmission of alarm condition and common reporting Configurable NO/NC contacts Very low power consumption Flexible relay logic Contact state configurable through GUI Software No coil hold on current provides higher availability Relay can slave the input, logic or display through GUI selection Re-transmission of critical alarms in one package 11

9 Integral power supplies Power source flexibility AC/DC & DC/DC Very wide DC input 18-58Vdc Internal/External field wetting voltage Very low operating current Can be accommodated on both 24V and 48V nom systems Internal/external FCV allows customer flexibility in wetting voltages Increased availability when on station batteries External FCV allows customer to use preferred wetting voltage 12

10 Secure panel fixing Easy to fit panel clamps Removable side clamp Long screw length Tapered screw point Clamp removal allows easy insertion in to panel cut-out Wide panel thickness accommodated Ensures good fixing to any type of panel Providing ease of fixing to simplify use 13

Summary Slide Specification Text F No. Feature Specification Text 1 High intensity LED s Customer replaceable High intensity LED s six colours and wide viewing angle 2 Legend windows customer accessible Customer printable acetate legends 3 Front panel USB access 4 Systems pushbuttons IP rated 5 PSU and watchdog LED s 6 GUI diagnostics Parameter changes and diagnostic via front panel IP Rated UBS Mini connector. Software configurable IP rated pushbutton, each configurable to various internal functions Two front of panel LED watchdogs to monitor PSU and communications status. Sophisticated diagnostics through a free GUI including communications and card status 7 Two part lockable connector Two part lockable screw connector with 2.5mm 2 rising clamp 8 Integral repeat relays Low power, internal latching repeat relays 9 Integral PSU AC/DC & DC/DC Wide input DC/DC 18-58Vdc or 85-265Vac PSU including power monitoring 10 Secure Panel Fixing Removable panel clamp provide fixing to 10mm thick panels 14

Alarm Solutions to the Worldwide Process and Power Industries

16