SUBITTAL DATA: SEZ-KD9A & SUZ-KA9A............... 9, BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: SEZ-KD9A Outdoor Unit: SUZ-KA9A OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-1) Bottom Return Plate (BRP-1) Outdoor Unit Drain Socket (AC-86DS) Drain Pan Heater (AC-6BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A; req.par-fa32a-e) Wireless Signal Receiver odule PAR-FA32A (for PAR-FL32A-E) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling* Rated Capacity....8,1 Btu/h Capacity Range...3,8-1,9 Btu/h SEER... 15. Total Input....6 W Heating at 4 F* Rated Capacity....1,9 Btu/h Capacity Range...4,8-14,1 Btu/h HSPF... 1. Total Input....1, W Heating at 1 F* Rated Capacity....6, Btu/h Rated Total Input...81 W aximum Capacity....6, Btu/h aximum Total Input...1, W *Rating Conditions (Cooling)-Indoor: 8ºF(2ºC)DB, 6ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 5ºF(24ºC)WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size.... 15 A OPERATIG CODITIOS Indoor Intake Temp. Outdoor Intake Temp. aximum 9 F (32 C) DB, 3 F (23 C) WB 115 F (46 C) DB Cooling inimum 6 F (19 C) DB, 5 F (14 C) WB 14 F (-1 C) DB aximum 8 F (2 C) DB, 6 F (19 C) WB 5 F (24 C) DB, 65 F (18 C) WB Heating inimum F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3...DC 12-24V Indoor Unit CA...1 A Fan Type x Quantity...Sirocco Fan x 2 Fan otor Type... Direct-driven DC Brushless otor Fan otor Output...96 W Fan otor...51 F.L.A. flow (Lo - ed - Hi).... 194-24 - 31 Dry CF 14-222 - 285 Wet CF Filter...Polypropylene Honeycomb External Static Pressure....2 -.6 -.14 -."WG Sound Pressure Level (Lo - ed - Hi)...23-26 - db(a) DIESIOS UIT ICHES / W 31-1/8 / 9 D 2-9/16 / H -/8 / Weight....42 lbs. / 19 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven CA...12 A OCP....15 A Fan otor...5 F.L.A. Sound Pressure Level Cooling...46 db(a) Heating...5 db(a) DIESIOS ICHES / W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...66 lbs. / kg External Finish... unsell o. 3Y.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...3/8" / 9.52 mm Liquid Side....1/4" / 6.35 mm ax. Refrigerant Pipe Length.... 65' / 19 m ax. Refrigerant Pipe Height Difference... ' / 12 m Connection ethod...flared
SEZ-KD9A IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS IDOOR FA PERFORACE AD CORRECTED AIR FLOW SEZ-KD9A (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] SEZ-KD9A (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.8] 1 [.4] [.16] [.8] 1 [.4] 4 5 6 8 9 1 [141] [16] [212] [24] [282] [318] [353] 4 5 6 8 9 1 [141] [16] [212] [24] [282] [318] [353] SEZ-KD9A (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 4 5 6 8 9 1 [141] [16] [212] [24] [282] [318] [353] SEZ-KD9A (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 4 5 6 8 9 1 [141] [16] [212] [24] [282] [318] [353] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
DIESIOS: SEZ-KD9A 345(13-19/32) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 5(2-1/4) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) 2 Refrigerant piping flare connection (liquid) (2-9/16) 6(26-21/32) Control box 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) ore than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A 52 98 66 (2-9/16) (29-5/8) (31-/16) (26) 9 952 998 86 (35-/16) (3-1/2) (39-5/16) (33-/8) F G 6 8 (23-5/8) (31-1/2) H 66 (26) 8 1 86 (31-1/2) (39-3/8) (33-/8) 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J 5 K 5 (19-11/16) (2-9/16) 9 (35-/16) L 16 24 839 (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
DIESIOS: SUZ-KA9A FOR# SEZ-KD9A & SUZ-KA9A - 118 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: 68-36-29 Fax: 8-889-994 Toll Free: 8-433-4822 (#3) www.mehvac.com Specifications are subject to change without notice.
SUBITTAL DATA: & SUZ-KA12A.............. 12, BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: Outdoor Unit: SUZ-KA12A OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-2) Bottom Return Plate (BRP-2) Outdoor Unit Drain Socket (AC-86DS) Drain Pan Heater (AC-6BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A;req.PAR-FA32A-E) Wireless Signal Receiver odule PAR-FA32A (for PAR-FL32A) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling* Rated Capacity....11,5 Btu/h Capacity Range...3,8-13, Btu/h SEER... 16. Total Input....9 W Heating at 4 F* Rated Capacity....13,6 Btu/h Capacity Range...4,8-16, Btu/h HSPF... 1. Total Input....1,1 W Heating at 1 F* Rated Capacity....9, Btu/h Rated Total Input...9 W aximum Capacity....9, Btu/h aximum Total Input...1,18 W *Rating Conditions (Cooling)-Indoor: 8ºF(2ºC)DB, 6ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 5ºF(24ºC)WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size.... 15 A OPERATIG CODITIOS Indoor Intake Temp. Outdoor Intake Temp. aximum 9 F (32 C) DB, 3 F (23 C) WB 115 F (46 C) DB Cooling inimum 6 F (19 C) DB, 5 F (14 C) WB 14 F (-1 C) DB aximum 8 F (2 C) DB, 6 F (19 C) WB 5 F (24 C) DB, 65 F (18 C) WB Heating inimum F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3... DC 12-24V Indoor Unit CA...1 A Fan Type x Quantity...Sirocco Fan x 2 Fan otor Type... Direct-driven DC Brushless otor Fan otor Output...96 W Fan otor...5 F.L.A. flow (Lo - ed - Hi).... 24-31 - 388 Dry CF 222-285 - 349 Wet CF Filter...Polypropylene Honeycomb External Static Pressure....2 -.6 -.14 -."WG Sound Pressure Level (Lo - ed - Hi)...23-28 - 33 db(a) DIESIOS UIT ICHES / W 39 / 99 D 2-9/16 / H -/8 / Weight....5 lbs. / 22 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven CA...12 A OCP....15 A Fan otor...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIESIOS ICHES / W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight... lbs. / 35 kg External Finish... unsell o. 3Y.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...3/8" / 9.52 mm Liquid Side....1/4" / 6.35 mm ax. Refrigerant Pipe Length.... 65' / 19 m ax. Refrigerant Pipe Height Difference... ' / 12 m Connection ethod...flared
IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.8] 1 [.4] [.16] [.8] 1 [.4] 6 8 9 1 11 12 [212] [24] [282] [318] [353] [388] [424] 6 8 9 1 11 12 [212] [24] [282] [318] [353] [388] [424] (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 6 8 9 1 11 12 [212] [24] [282] [318] [353] [388] [424] (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 6 8 9 1 11 12 [212] [24] [282] [318] [353] [388] [424] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
DIESIOS: 345(13-19/32) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 5(2-1/4) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) 2 Refrigerant piping flare connection (liquid) (2-9/16) 6(26-21/32) Control box 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) ore than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A 52 98 66 (2-9/16) (29-5/8) (31-/16) (26) 9 952 998 86 (35-/16) (3-1/2) (39-5/16) (33-/8) F G 6 8 (23-5/8) (31-1/2) H 66 (26) 8 1 86 (31-1/2) (39-3/8) (33-/8) 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J 5 K 5 (19-11/16) (2-9/16) 9 (35-/16) L 16 24 839 (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
DIESIOS: SUZ-KA12A FOR# & SUZ-KA12A - 118 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: 68-36-29 Fax: 8-889-994 Toll Free: 8-433-4822 (#3) www.mehvac.com Specifications are subject to change without notice.
SUBITTAL DATA: & SUZ-KA15A.............. 15, BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: Outdoor Unit: SUZ-KA15A OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-2) Bottom Return Plate (BRP-2) Outdoor Unit Drain Socket (AC-86DS) Drain Pan Heater (AC-6BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A;req.PAR-F 32A-E) Wireless Signal Receiver PAR-FA32A (for PAR-FL32A-E) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling* Rated Capacity....14,1 Btu/h Capacity Range...3,8-1, Btu/h SEER... 15.5 Total Input....1,1 W Heating at 4 F* Rated Capacity....18, Btu/h Capacity Range...4,8-21,1 Btu/h HSPF... 1. Total Input....1,5 W Heating at 1 F* Rated Capacity....11,9 Btu/h Rated Total Input...1, W aximum Capacity....11,9 Btu/h aximum Total Input...1,65 W *Rating Conditions (Cooling)-Indoor: 8ºF(2ºC)DB, 6ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 5ºF(24ºC)WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size.... 15 A OPERATIG CODITIOS Indoor Intake Temp. Outdoor Intake Temp. aximum 9 F (32 C) DB, 3 F (23 C) WB 115 F (46 C) DB Cooling inimum 6 F (19 C) DB, 5 F (14 C) WB 14 F (-1 C) DB aximum 8 F (2 C) DB, 6 F (19 C) WB 5 F (24 C) DB, 65 F (18 C) WB Heating inimum F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3... DC 12-24V Indoor Unit CA...1 A Fan Type x Quantity...Sirocco Fan x 3 Fan otor Type... Direct-driven DC Brushless otor Fan otor Output...96 W Fan otor...4 F.L.A. flow (Lo - ed - Hi).... 353-441 - 529 Dry CF 31-396 - 46 Wet CF Filter...Polypropylene Honeycomb External Static Pressure....2 -.6 -.14 -."WG Sound Pressure Level (Lo - ed - Hi)... - 34-3 db(a) DIESIOS UIT ICHES / W 39 / 99 D 2-9/16 / H -/8 / Weight....54 lbs. / 24 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven Twin Rotary CA...12 A OCP....15 A Fan otor...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIESIOS ICHES / W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...8 lbs. / 36 kg External Finish... unsell o. 3Y.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12. mm Liquid Side....1/4" / 6.35 mm ax. Refrigerant Pipe Length.... 65' / 19 m ax. Refrigerant Pipe Height Difference... ' / 12 m Connection ethod...flared 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.8] 1 [.4] [.16] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
DIESIOS: 345(13-19/32) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 5(2-1/4) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) 2 Refrigerant piping flare connection (liquid) (2-9/16) 6(26-21/32) Control box 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) ore than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A 52 98 66 (2-9/16) (29-5/8) (31-/16) (26) 9 952 998 86 (35-/16) (3-1/2) (39-5/16) (33-/8) F G 6 8 (23-5/8) (31-1/2) H 66 (26) 8 1 86 (31-1/2) (39-3/8) (33-/8) 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J 5 K 5 (19-11/16) (2-9/16) 9 (35-/16) L 16 24 839 (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
DIESIOS: SUZ-KA15A FOR# & SUZ-KA15A - 118 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: 68-36-29 Fax: 8-889-994 Toll Free: 8-433-4822 (#3) www.mehvac.com Specifications are subject to change without notice.
SUBITTAL DATA:...18, BTU/H HORIZOTAL-DUCTED IDOOR UIT FOR XZ-B ULTI-ZOE HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule o.: GEERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: -/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors OPTIOAL ACCESSORIES Indoor Unit Filter Box with ERV 8 Filters (FBL1-3) Bottom Return Plate (BRP-3) Outdoor Unit Drain Socket (AC-811DS) Drain Pan Heater (AC-641BH-U) Three-pole Disconnect Switch (TAZ-S3) Outlet Guide (AC-856SG) ounting Base (DSD-) ounting Pad (ULTRILITE1) Wall-mounting Brackets (CWB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21AA) -ET Control Adapter (AC-399IF) Remote Temperature Sensor (21-JKO-) Hand-held Wireless Remote Controller (PAR-FL32A; eq.par-fa32a-e) Wireless Signal Receiver odule PAR-FA32A (for PAR-FL32A) Lockdown Bracket for Hand-held Controller (RCKP1CB) Cooling Capacity*....1, Btu/h Heating Capacity at 4 F*...21,6 Btu/h * Rating Conditions (Cooling) - Indoor: 8ºF (2ºC) DB, 6ºF (19ºC) WB; Outdoor: 95ºF (35ºC) DB, 5ºF (24ºC) WB. (Heating at 4ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 4ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 1ºF) - Indoor: ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 1ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz CA... 1 A SZ-GE SEZ and PEAD-A24AA Indoor Unit: Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3... DC 12-24V Fan otor...4 F.L.A. flow (Lo - ed - Hi) Cooling...423-529 - 635 Dry CF 381-46 - 52 Wet CF Heating...423-529 - 635 Dry CF Sound Pressure Level (Lo - ed - Hi) Cooling... - 34-38 db(a) Heating... - 34-38 db(a) DIESIOS UIT ICHES / W 46-/8 / 1,19 D 2-9/16 / H -/8 / Weight....62 lbs. / 28 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12. mm Liquid Side....1/4" / 6.35 mm Connection ethod...flared XZ-B SERIES HEAT-PUP OUTDOOR UITS ULTI-ZOE OUTDOOR UIT XZ-B ULTI-ZOE SYSTES CA ICLUDE: Ducted Indoor Units: SEZ-KD9,12,15,18A, PEAD-A24AA onducted Indoor Units: SZ-GE6,9,12,15,18,24A, SZ-FE9,12,18A, FZ-KA9,12,18A, PCA-A24KA, SLZ-KA9,12,15A, and PLA-A12,18,24BA A combination of both Ducted and onducted Indoor Units Refer to the separate submittal forms for the SZ-GE, SZ-FE, FZ-KA, SEZ-KD, SLZ-KA, PEAD, PCA, PLA Indoor Units, and XZ Outdoor Units. SZ-FE FZ-KA PCA-A24KA SLZ and PLA-A12,18,24BA 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
IDOOR FA PERFORACE AD CORRECTED AIR FLOW CHARTS (External static pressure.2[in.wg](5pa)) 8/2V 6Hz [.16] [.8] 1 [.4] 9 1 11 12 13 14 15 16 1 18 19 [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.16] [.8] 1 [.4] 9 1 11 12 13 14 15 16 1 18 19 [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 9 1 11 12 13 14 15 16 1 18 19 [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] [.28] 6 [.24] 5 [.] [.16] [.8] 1 [.4] 9 1 11 12 13 14 15 16 1 18 19 [318] [353] [388] [424] [459] [494] [5] [565] [6] [636] [61] 11 ITSUBISHI ELECTRIC & ELECTROICS, IC.
DIESIOS: 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) 345(13-19/32) (Emergency draining) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 3(1-15/32) 1(3-15/16) 15.5(6-/32) 3(1-15/32) Unit : mm(in.) 25(1) 5(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) outlet inlet A B (Suspension bolt pitch) C H 1(3-15/16)XJ=K 1(3-15/16) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 5(2-1/4) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) (2-25/32) 2(1-21/32) (2-9/16) 6(26-21/32) Control box 2 Refrigerant piping flare connection (liquid) 12(4-1/32) 1(6-23/32) 9 (3-9/16) (-/8) (Indoor/outdoor connecting line) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) filter ote2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) 45 (-19/32) 15±5(6-29/32±/32) (Actual length) ore than Required space for service and maintenance Less than Less than 55 (21-21/32) ore than 1 (13/32) Drain hose (I.D.ø32(1-1/4)) <accessory> ore than (13/16) Ceiling surface ake the access door at the appointed position properly for service maintenance. odel A B C D SEZ-KD9A 52 98 66 (2-9/16) (29-5/8) (31-/16) (26) 9 952 998 86 (35-/16) (3-1/2) (39-5/16) (33-/8) F G H 6 8 66 (23-5/8) (31-1/2) (26) 8 1 86 (31-1/2) (39-3/8) (33-/8) 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (4-3/16) (41-3/4) 11 (39-3/8) (4-1/4) (41-3/4) 9 ote1.use 1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for model,which has 3 fans. SEZ-KD9,12A models have 2 fans. models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 9 J K 5 5 (19-11/16) (2-9/16) 9 (35-/16) L 16 24 839 (33-1/16) 139 (-29/32) 1239 (48-25/32) 9 (31-1/8) 99 (39) 119 (46-/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.(1/2) FOR# - 118 11 ITSUBISHI ELECTRIC & ELECTROICS, IC. 3 Lawrenceville Suwanee Rd Suwanee, GA 24 Tele: 68-36-29 Fax: 8-889-994 Toll Free: 8-433-4822 (#3) www.mehvac.com Specifications are subject to change without notice.