International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Similar documents
Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

II. OBJECTIVE OF RESEARCH

Performance investigation of Air-conditioning system using ejector as expansion device

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

International Engineering Research Journal Performance Analysis of Ejector Based Solar Air Conditioning System

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

ADVANCES in NATURAL and APPLIED SCIENCES

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Purdue e-pubs. Purdue University

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

SAMPLE STUDY MATERIAL

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Performance Assessment of Water Cooled Condenser Refrigeration System

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

SSC-JE STAFF SELECTION COMMISSION MECHANICAL ENGINEERING STUDY MATERIAL REFRIGERATION CYCLES REFRIGERATION CYCLES REFRIGERATION CYCLES

Numerical Simulation of Window Air Conditioner

Enhancement of COP in Vapour Compression Refrigeration System

Performance Study of Triple Concentric Pipe Heat Exchanger

*Corresponding author;

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Thermodynamic Analysis of Ammonia-Water Absorption Refrigeration System with Ejector

REFRIGERATION AND AIR CONDITIONING

Experimental Study Of An Ejector Refrigeration System

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Design of LPG Refrigeration System

Performance of an Improved Household Refrigerator/Freezer

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Exploring the Performance Characteristics of CO2 Cycles in a Breadboard-Type Test Facility

Chapter 10. Refrigeration and Heat Pump Systems

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

DEEPAK PALIWAL, S.P.S.RAJPUT

Heat Pump Fluidised Bed Dryer with CO 2 as Refrigerant Measurements of COP and SMER

(Refer Slide Time: 00:00:40 min)

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Refrigerant Glide and Effect on Performances Declaration

Low GWP Refrigerants for Air Conditioning Applications

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Vapour Jet Refrigerator / Heat Pump R853

Study of solar-thermal collector assisted hybrid split air conditioner

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Improvement Of Energy Efficiency Ratio Of Refrigerant Compressor

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

ABSTRACT. Research Professor Yunho Hwang, Ph.D. Department of Mechanical Engineering

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Transcription:

Experimental Investigation To Develop The Refrigeration System With Two Phases Condensing Ejector Along With Energy Saving Anjani Kumar 1, Kuldip Kumar 2, Ujjwal Kumar Nayak 3 123 Department of mechanical engineering, B.I.T.Sindri, Dhanbad-828123, Jharkhand, India Abstract This experimental model presents a method of reduce energy consumption and enhance the refrigerating effect. With the help of two phases condensing ejector it is found that ejector work as sub compressor in refrigeration flow cycle. That helps to reduce compressor load effectively and hence improve refrigerating effect. The new cycle includes a second step compression by an ejector device, the compressor compresses the vapour to approximately 4/5 of the final pressure and additional compression (i.e. 1/5 of final pressure) is provided in an ejector, the thermodynamic model has developed for R134 and R22 refrigerant showing a possible efficiency improvement as compared to the traditional vapour compression cycle. The investigation of a new cycle for vapour compression refrigeration with using a novel device for non-mechanical compression of refrigerants is called a condensing ejector has carried out within this project. This novel device is a hybrid of simple vapour compression refrigeration system [SVCRS] and ejector refrigeration system [ERS] is more attractive than traditional refrigeration system because of higher coefficient of performance [COP].That leads the energy saving for same amount of cooling. Keywords Reciprocating Compressor, Two Phase Ejector, Condenser, Refrigerant Separator, Capillary, Drier, Evaporator, Pressure Gauge, Thermostat, Thermocouple and Refrigerant. I. INTRODUCTION Vapour compression cycles are used in refrigeration, space cooling and space heating applications. Typical vapour compression cycles involve compressing and decompressing a refrigerant in a closed loop system and circulating the refrigerant through an evaporator and a condenser. The refrigerant serves to absorb thermal energy in the form of heat from the evaporator and transport the thermal energy to the condenser where it can be released. In refrigeration and cooling applications heat is absorbed from a space by the refrigerant during an evaporation portion of the cycle where the refrigerant changes into a vapour phase. The absorption of heat provides useful cooling of the space. The vapour is subsequently compressed in a compressor. Energy is consumed by the compressor during the compression of the vapour. Compression of the vapour facilitates condensation of the vapour into a liquid. Condensation of the vapour is caused by flowing the compressed vapour through a condenser where heat is released into a heat sink thereby condensing the refrigerant into a liquid. The liquid is circulated through the closed loop to a decompression device, typically an expansion valve and capillary tube where the pressure of the refrigerant is decreased. Typically, the refrigerant pressure is reduced by a factor of five or more. The decompressed refrigerant is returned to the evaporator resuming the cycle. The investigation of a new cycle for vapor compression refrigeration with using a novel device for non - mechanical compression of refrigerants, called a condensing ejector was carried out within this project. The condensing ejector is a two-phase jet device in which a subcooled homogeneous working medium in a liquid state is mixed with its vapor phase, producing a liquid stream with a pressure that is higher than the pressure of either of the two inlet streams. The mixing takes place first in a convergent section and then in a constant area section of the ejector device. There is a large temperature difference and a high relative velocity between both streams, which results in a high rate of a heat and momentum transfer. The vapor phase is quickly condensed onto the liquid stream, producing rapid transformation from two-phase into single-phase flow with a resulting rise in pressure, called a condensation shock. While a theoretical basis for the condensing ejector principle has been reasonably established in the past, only two practical applications have been reported for underwater propulsion and liquid metal MHD power generation (Miguel et al., 1964).The first theoretical principles of the ejector as reported by Bohdal et al. (2003) in his state-of-the art presentation were elaborated by Parsons (1911) while the first prototype was built by Leblanc (1910). Further improvements were introduced by Gay (1931). Ejectors were first applied for refrigeration cycles by Heller (1955) for absorption systems and by Badylkes (1958) for vapor compression systems. In the USA, the first application was reported by Kemper (1966), but only the patent is in existence while no experimental or theoretical background has been published. Following up on this early work, a theoretical analysis was conducted, showing the potential efficiency improvement of 21% when compared with a standard vapor compression cycle (Kornhauser, 1990). The prototype unit was built, however its performance was much less than ideal and reached a maximum of only 5% improvement using working fluids CFCs/ Page 26

HCFCs/ HFCs. In all applications listed above, the ejector is designed as a classic Venturi nozzle, which means that the outlet cross-section of a motive nozzle must be smaller than the cross section of the mixing chamber. The outlet pressure in Venturi nozzles is the intermediate between pressures of the working and transporting medias. The advantage of using the ejector is to raise the pressure of delivered compressed vapor by the primary compressor resulting in reduced compressor work, and increased cycle efficiency. In general, only a few instances of practical use of the ejectors in refrigeration cycles were found. So it is required to develop a simple, lighter, and economical two phase ejector refrigeration system so that is it could be used in regular practice and ultimately save the energy for the same amount of cooling because high efficient performance of the system. TWO PHASE CONDENSING EJECTOR The condensing ejector is a two-phase jet device in which a sub-cooled homogeneous working medium in a liquid state is mixed with its vapor phase, producing a liquid stream with a pressure that is higher than the pressure of either of the two inlet streams. A two-phase flow ejector consists of four sub-models: motive nozzle flow, suction nozzle flow, mixing section flow and diffuser flow models. The mixing takes place first in a convergent section and then in a constant area section of the ejector device. There is a large temperature difference and a high relative velocity between both streams, which results in a high rate of a heat and momentum transfer. The vapor phase is quickly condensed into the liquid stream, producing rapid transformation from two phases into single phase flow with a resulting rise in pressure, called a condensation shock. While the mixed stream flows through the diffuser, the static pressure of the flow rises as the kinetic energy is converted to static pressure. The advantage of using the ejector is to raise the pressure of delivered compressed vapor by the primary compressor resulting in reduced compressor work. The ejector is modelled using the following assumptions:- The flow inside the motive nozzle is steady and one dimensional. The nozzle is a converging nozzle and its throat is at its exit. At the nozzle throat, the flow reaches the critical flow condition The inlet flow velocity is neglected. The heat transfer between the fluid and the nozzle & ejector wall is neglected. The gravitational force effect on the flow is neglected. The mixed stream at the outlet of the mixing section is in homogeneous equilibrium. The divergent section is designed as to prevent the flow separation effect. The length of divergent section limited as to avoid back flow occurs at exit. Fig.1 Illustrates the pressure variation along the ejector. Fig 2,3: pressure variation along the condensing ejector Page 27

II. REFRIGRATION CYCLE WITH TWO PHASE CONDENSING EJECTOR Working principle of two phase ejector has been discussed in above presented diagrams as well as assumptions. Now here explain the principle under working refrigeration cycle which is represented in block diagram a shown below Fig. Refrigerant vapour enters the compressor and mechanically compressed up to 4/5 of final pressure and further remaining compressed by two phase ejector i.e. 1/5 of the final pressure. This additional non-mechanical work done by ejector significantly save power. System details as:- 1-main piping connection, 1-2 evaporator, 3-compressor, 4-two phase condensing ejector, 5-condensor, 6-refrigerant separator, 7-8 capillary tube, 9-drier filter, 10-secondary flow into the two phase ejector, 11-heat absorbed from the refrigerated space by refrigerant,12-heat delivered to the atmosphere from the refrigerant by the condenser. FIG.4 SCHEMATIC OF THE REFRIGERATION SYSTEM WITH THE CONDENSING EJECTOR AS A SECOND-STAGE COMPRESSOR III. PRESSURE ENTHALPY DIAGRAM FOR TWO PHASE EJECTOR REFRIGRATION SYSTEM FIG.5 COMPARISON OF P-H DIAGRAMS OF THE NEW REFRIGERATION CYCLE WITH A TWO-PHASE EJECTOR AND TRADITIONAL CYCLE Diagram show thermodynamic states of refrigerant which flow under the two phase condensing ejector system as well shown comparison between traditional cycle and new develop cycle along with saving energy. Cycle 1-2-3-4-4-5-1 represents novel two phase ejector refrigeration system and Cycle 1-2-3-3 -4-5-1 represents traditional refrigeration system. Here from the P-H diagram it is clear that new cycle save the energy for the same amount of refrigerating effect produce. Part of diagram 3-3 -4-4-3 represent amount of work save by the two phase condensing ejector and hence improve COP of refrigeration system. Page 28

IV. LAVORATOTRY EXPERIMETAL SETUP This setup has been fabricated in the Heat-Engine laboratory at BIT, SINDRI. This is possible as study of the basic schematic diagram shown above Fig.4 and with observing basic principles of design and assembly of refrigeration systems. Its overall view is shown in Fig.6.The laboratory experiments were then carried out with two main objectives: the first being to investigate the possibility of the pressure jump on the ejector and the second to determine the energy savings for the cycle with the ejector vs. traditional cycle with single step compression. FIG.6 V. CALCULATION AND RESULTS OF LABORATORY EXPERIMENT Data obtained from experiment with working fluid as R-134a (Refrigerant) and some needed data evaluated by properties table &P-H diagram of R-134a as:- Inlet condition of compressor Pressure = 0.6 bar, Temperature = -2 Outlet condition of compressor Pressure =10 bar, Temperature = 55 Raised pressure after two phase ejector = 11.3 bar Outlet condition of condenser Pressure = 11.28 bar, Temperature = 43, Enthalpy (h1) =395 KJ/kg, Enthalpy (h2) = 431 KJ/kg, Enthalpy (h3) = 262 KJ/kg Inlet condition of evaporator We know Enthalpy (h4) = Enthalpy (h3) = 262 KJ/kg (a) Coefficient of performance of two phase refrigeration cycle with two phase ejector COP = COP = = = 3.69 (b) Coefficient of performance of two phase refrigeration cycle without two phase ejector We know that if two phase ejector not placed here then total work in compression is done by main compressor, then at pressure 11.28 bar and temperature 55 enthalpy (h 2 ) be 438KJ/kg COP = Page 29

COP = = = 3.09 Percentage increment of COP of novel cycle with respect to tradition cycle is about 19% VI. CONCLUSION In this paper an experimental analysis has performed with two phase ejector refrigeration system and this novel cycle is compared with traditional refrigeration cycle. The objectives of the first phase of this project were met by: Conducting a state-of-an-art study, which confirmed that this project might represent the first attempt to practically use two-phase flow phenomena with refrigerant as a working medium? Developing the theoretical model that showed possible efficiency improvement of 19% as compared to the traditional vapour compression cycle. The key scientific objective is to obtain the pressure rise with non mechanical by the ejector due to this compressor work reduced. REFERENCES [1] Miguel, J., Brown, G.A., An Analytical and Experimental Investigation of a Condensing Ejector with a Condensable Vapor, AIAA Paper, No. 64-469, 1964 [2] Bohdal T. et. al., Urzadzenia chlodnicze sprezarkowe parowe (book in Polish), WNT, Warsaw 2003, 529 p. [3] Kornhauser, A.A., The use of and Ejector as a Refrigerant Expander, Proc. of 1990 USNCR/IIR-Purdue [4] Refrigeration Conference, West Lafayette, IN. p.10-19. [5] Parsons, C.A., The Steam Turbine, Rede Lecture, Cambridge. University Press, Cambridge, (1911) [6] Elbel, S.W., Hrnjak, P.S., Effect of Internal Heat Exchanger on Performance of Transcritical CO2 Systems with [7] Ejector, Intern. Refrigeration and Air Conditioning Conf. at Purdue, July 12-15, 2004, Paper No. R166 [8] Hernandez JI, Dorantes RJ, Best R, Estrada CA. The behavior of a hybrid compressor and ejector refrigeration system with refrigerants 134a and 142b. Applied Thermal Engineering 2004;24:1765 83. [9] Science-direct, Wikipedia and Nptel study source etc. Page 30