BAC-4000 Series AppStat

Similar documents
Installation and Maintenance Manual IM

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

Document # R01

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Networkable Fan Coil Controller Specification and Installation Instructions

Multiview Monitor / Controller

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Installation Guide IM 1248

T606MSx-4 and T606MSx-4+PIR Series Multi-Stage

I/O ZONE 560/583 USERS GUIDE

TEC3000 Series Stand-Alone and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers

TEC210x-2 Series Networked Thermostats

TER Active Room Temperature Sensor (Controller),

CONTENTS. Installation Guide. VT7200 Series

TEC2100 Series Networked Thermostats

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

Oxygen (O2) Single-Point Gas Detection System

TEC1100 Series Thermostats

Siemens Thermostats. RDY2000BN Thermostat

SECTION LIGHTING CONTROLS

Sensor and Thermostat Selection Fundamentals

Product Manual SZ1009

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

Unit Vent for AppController overview and specifications

Carbon Monoxide Transmitter

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat. Table of Contents. Description. Initial Thermostat Power up

Table of Contents. Unit Ventilator

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Fan Coil for AppController overview and specifications

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Document # R00

VisionPRO 8000 with Wi-Fi

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Room thermostats with LCD for wall mounting

Job Name Control Systems Description Date

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Sensors and Detectors

Product Manual SZ1022/SZ1031/SZ1035/

Spartan Peripheral Devices. TE 256S Thermostat Applications

ET10 Series Stand-alone LCD Fan Coil Thermostat

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

Natural Ventilation Controller with 24vDC drive NVC-1204

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

Application Guide, Rev T

Homework 5: Theory of Operation and Hardware Design Narrative

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Siemens RDY2000BN. Start Up Guide

CM3500 Controller - ClimateMaster DOAS Water-Source Heat Pumps - Rev.: 7 Oct, 2008B

ETAF Series VDC Fan output LCD Fan Coil Thermostat

ComfortSense 7500 Commercial Thermostat. User Guide

1.0 Digital Controller

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

Control solutions Biofloor

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Version Inc Series Digital Gas Detector/Controller. Operation Manual

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

Contents. Appendix E: LonWorks Protocol Implementation Conformance Statement Document revision history... 47

Net/X US32 Universal Setback Communicating Thermostat

I/A Series 716C 1/16 DIN Temperature Controller

CLEANROOM MONITOR CR3A Network - Installation Instructions

Inc Series Digital Gas Detector/Controller. Operation Manual

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

Introduction. What is the W2W Open controller?

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Accuracy by Design Products for the HVAC Professional

Temperature Controllers

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

INSTALLATION INSTRUCTIONS

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Predator Controller Hardware Family

- Data Brochure Universal Reset Module 422

Process Alarm Module RTA 421

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Application guide RDG160 Remote control

Hubbell NX500 High Efficiency Gas Condensing Water Heater

- Data Brochure Universal Reset Module 423

MicroTech Unit Ventilator

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Cultivator & Hybrid Cultivator

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Product Manual SZ1145

VT8300 Series Installation Guide 24 Vac Low Voltage

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

Q7800H Integrated Burner Control Subpanel

iworx Air Side Application Wiring Guide

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

Analog Room Pressure Monitor RPC Series

Transcription:

BAC-4000 Series AppStat Description The KMC AppStat combines the power of a space mounted equipment controller with the convenience of built-in temperature, humidity and motion sensors. The controllers include a wide range of factory supplied programs for the following applications. Two and four pipe fan coil units Roof top units Heat pump units Packaged and split unitary systems Stand alone operation No special programming, software applications, or setup tools are required to configure and commission an AppStat. All options can be set by using only the five front panel buttons and the easy-to-read menus in the full color display. New or retrofit applications The attractive two-piece design is ideal for new installations or upgrades of older, less efficient thermostats. AppStat installation requires only mounting the backplate to a wall or electrical box, connecting wires to screw terminals, and plugging the AppStat into the backplate. Bright, full-color display The full color display is easy to read across a room even in bright sunlight. Users can easily choose between Fahrenheit or Celsius values. The display features large numbers and simple color icons to indicate heating or cooling, occupied, unoccupied or local setback modes, and fan operation. For models with a humidity sensor, the temperature and humidity values alternate on the display. Network ready All models are native BACnet, Application Specific Controllers ready to connect to a BACnet MS/TP network. Device instance, MAC address, and baud rate are set from the password protected front controls. All models feature a hardware clock and BACnet schedule that can be set up from the front panel or as standard BACnet objects and properties. Shown with optional motion sensor. Specifications Full color user interface The user interface is a color display and with five push buttons. Backlighting automatically starts when any button is pushed and remains lit for 60 seconds after the last button is pushed. Through the menu driven display, an operator can do the following. Change setpoints and fan, heating, cooling modes. Choose between Fahrenheit or Celsius values Set BACnet addressing Set up and commission the installation Add or change user passwords Configure any available options Security Separate passwords for users and control technicians and engineers. Screen type 128 128 pixels Active color LCD with LED back lighting 1.00 x 1.04 inches (25 x 26 mm) Specifications and design subject to change without notice.

Specifications Inputs and outputs All inputs and outputs for the AppStat are set up at the factory and do not require set up in the field. Inputs Analog inputs for discharge air temperature, water supply temperature, outside air temperature, fan status, and remote. Sensors are automatically detected Inputs accept industry-standard 10K ohm (Type II or III) thermistors sensors. Input overvoltage protection up to 24 volts AC, continuous. 12-bit analog-to-digital conversion Relay outputs All relay outputs are normally open, SPST, Form A relays 1 Ampere maximum per relay at 24 volts AC or DC for each output. Maximum for all relay outputs is 3 amperes (72VA) Analog outputs Short-circuit protected Loads up to 10 ma at 0 12 volts DC 8-bit PWM digital-to-analog conversion Connections Screw terminal blocks, wire size 14 22 AWG, for inputs, outputs, power, and network connections. Motion sensor range Detector type Passive infrared Range 33 feet (10 meters). See diagrams. 10 m 32.8 ft X 10 m 32.8 ft Y 46.5 BACnet communication Integral peer-to-peer BACnet MS/TP network communications. Network speed from 9600 to 76,800 baud Front panel selection for device instance, MAC address, and baud rate Meets or exceeds ANSI/ASHRAE BACnet Standard 135-2008 for Application Specific Controllers. Accuracy temperature only models Type Thermistor Accuracy ±0.36 F (±0.2 C) Resistance 10,000 Ω at 77 F (25 C) Operating range 48 to 96 F (8.8 to 35.5 C) Accuracy temperature and humidity models Temperature Sensor Type CMOS Accuracy ±0.9 F offset (±0.5 C) from 40 to 104 F (4.4 to 40 C) Resolution ±0.1 F (±0.1 C) Operating range 36 to 120 F (2.2 to 48.8 C) Response time 5 to 30 seconds Humidity Sensor Type CMOS Humidity 0 to 100% RH Accuracy @ 25 C ± 2% RH (10 to 90% RH) Response time 4 seconds or less Regulatory approvals UL 916 Energy Management Equipment FCC Class A, Part 15, Subpart B and complies with Canadian ICES-003 Class B BACnet Testing Laboratory listed SASO PCP Registration KSA R-103260 0 0 Accessories XEE-6111-040 Single-hub 120 volt transformer XEE-6112-040 Dual-hub 120 volt transformer HMO-10000W White mounting plate for horizontal or 4 x 4 handy box wall mounting 10 m 32.8 ft 55 Top view 10 m 32.8 ft Side view

Operating sequences s AppStats for the control of fan coil units are available with inputs, outputs, and sequences of operation for the following functions. Two-pipe heating and cooling with on/off valves, modulating valves, or both Four-pipe heating and cooling with on/off valves, modulating valves, or both Three-speed or modulating fan control Automatic or manual fan control Local temperature setback mode based on optional built-in motion sensor Dehumidification on models with humidity sensor Roof Top and Unitary Units AppStats for the control of roof top or similar packaged or split unitary units are available with inputs, outputs, and sequences of operation for the following functions. One or two stage heating One or two stage cooling Optional economizer Automatic or manual fan control Modulating valves or on/off heating and cooling valves Local temperature setback mode based on optional built-in motion sensor Dehumidification on models with humidity sensor Heat Pump Units AppStats for the control of heat pump units are available with inputs, outputs, and sequences of operation for the following functions. Two stages of heat and two stages of cooling plus auxiliary heat Optional economizer Dehumidification-in models with auxiliary heat and a humidity sensor Local temperature setback mode based on optional built-in motion sensor Automatic or manual fan control Installation information Mounting Backplate mounts to a standard 2 x 4 inch vertical handy-box or Euro style box. The controller is secured to the backplate with a concealed Allen screw. Material Weight A White flame-retardant plastic Approx. 6 oz. (170 grams) Supply voltage 24 volts AC ( 15%, +20%), 50-60 Hz, 12 VA, Class 2 only, non-supervised (all circuits, including supply voltage, are power limited circuits) Environmental Limits Operating 32 to 140 F (0 to 49 C) Shipping 40 to 160 F ( 40 to 71 C) Humidity 0 to 95% RH non-condensing Dimensions A B C 3.50 in. 5.12 in. 1.13 in. 89 mm 130 mm 29 mm B C

Applications The following block diagrams are only a sample of the applications available for the AppStat models for fan coil units. Complete details for all AppStat applications are in the manual Installation, Applications, and Operation for AppStat available at GetAppStat.com. Two-pipe with modulating valve Variable or one, two or three speed fan Four-pipe with on/off valves Variable or one, two or three speed fan FST Four-pipe with modulating valves Variable or one, two or three speed fan FST *Fan status switch, discharge air and remote space s are optional items.

Roof Top Unit Applications The following block diagrams are only a sample of the applications available for the AppStat models for roof top units or similar packaged or split unitary units. Complete details for all AppStat applications are in the manual Installation, Applications, and Operation for AppStat available at GetAppStat.com. Two-stage DX cooling and two-stage gas heat DX DX GAS GAS Chilled water cooling and two-stage gas heat GAS GAS Economizer FST Outside air Chilled water cooling and hot water heat with modulating valves Economizer FST Outside air * Economizer, fan status switch, discharge air and remote space s are optional items.

Heat Pump Unit Applications The following block diagrams are only a sample of the applications available for the AppStat models for heat pump units. Complete details for all AppStat applications are in the manual Installation, Applications, and Operation for AppStat available at GetAppStat.com. Single compressor heat pumps REV VALVE Dual compressor heat pumps REV Outside air Dual compressor heat pumps with economizer and auxiliary heat REV VALVE Outside air * Economizer, discharge air and remote space s are optional items.

Ordering information for AppStat models Application Options Model number On/Off valves Three-speed fan BAC-4221CW0001 BAC-4021CW0001 Without humidity sensor BAC-4201CW0001 BAC-4001CW0001 Modulating valves Three-speed fan On/Off valves Modulating speed fan Modulating valves Modulating speed fan Modulating or On/Off valves Three-speed or modulating speed fan BAC-4222CW0001 BAC-4022CW0001 Without humidity sensor BAC-4202CW0001 BAC-4002CW0001 BAC-4227CW0001 BAC-4027CW0001 Without humidity sensor BAC-4207CW0001 BAC-4007CW0001 BAC-4228CW0001 BAC-4028CW0001 Without humidity sensor BAC-4208CW0001 BAC-4008CW0001 BAC-4223CW0001 BAC-4023CW0001 Without humidity sensor BAC-4203CW0001 BAC-4003CW0001 Ordering information for AppStat Roof Top Unit models Application Options Model number Roof Top Unit On/Off valves One or two-stages heat One or two stages cooling Fan control BAC-4221CW0002 BAC-4021CW0002 Without humidity sensor BAC-4201CW0002 BAC-4001CW0002 Roof Top Unit Modulating or on/off valves One or two-stages heat One or two stages cooling Fan control Economizer BAC-4223CW0002 BAC-4023CW0002 Without humidity sensor BAC-4203CW0002 BAC-4003CW0002

Ordering information for Heat Pump models Application Options Model number Heat Pump Unit 3 heat, 2 cool Fan control BAC-4221CW0003 BAC-4021CW0003 Without humidity sensor BAC-4201CW0003 BAC-4001CW0003 Heat Pump Univt 3 heat, 2 cool Fan control Economizer BAC-4223CW0003 BAC-4023CW0003 Without humidity sensor BAC-4203CW0003 BAC-4003CW0003 KMC Controls, Inc. 19476 Industrial Drive New Paris, IN 46553 574.831.5250 www.kmccontrols.com info@kmccontrols.com 2018 KMC Controls, Inc. 919-035-01E