DT/DTH/DR/DRH MERIT SERIES

Similar documents
DT-2 & DR-2 MERIT SERIES

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL

G61MPV SERIES GAS FURNACE WARNING

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

EL195DFE SERIES GAS FURNACE WARNING

EL195UH SERIES GAS FURNACE WARNING

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD.

ML180UH SERIES GAS FURNACE WARNING WARNING

G UPFLOW GAS FURNACE

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

INSTALLATION INSTRUCTIONS

USER S INFORMATION MANUAL

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

User s Information Manual

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL SLP98UHV SERIES

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

PROBLEM CAUSE SOLUTION

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Cast Iron Commercial Hot Water Or Steam Boiler

USER S INFORMATION MANUAL

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

TO DO IF YOU SMELL GAS

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

USER S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

User manual. Logano GC 124 II. Gas boiler

HWX GAS BOILERS USER S INFORMATION MANUAL

USER'S INFORMATION MANUAL

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV

USER S INFORMATION MANUAL (2,4)SG13B

DANGER HOMEOWNER S MANUAL INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

USER'S INFORMATION MANUAL

Installation/Operating Instructions

USER'S INFORMATION MANUAL

Models #CSK-31 #CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

Legend VENTED GAS FIREPLACE HEATERS

USER'S INFORMATION MANUAL

Operating instructions

User s Information Manual Models: 45, ,000 Btu/hr

USER'S INFORMATION MANUAL

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Models #CSK-335 #CSK-335-RF. CHASKA - XL Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

f i r e - p a r t s. c o m

HOMEOWNER S MANUAL. CONTEMPORARY LINEAR VENT-FREE GAS FIREPLACE ModELS

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND.

GAS UNITS KITS AND ACCESSORIES 505,172M 08/06

MODEL 329 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A FREESTANDING FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND.

Using it in an enclosed space can kill you.

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Operating instructions

MODEL 36 MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND

OPERATING INSTRUCTIONS AND OWNER S MANUAL

INSTALLATION AND OPERATING MANUAL

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

#CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

WARNING HOMEOWNER S MANUAL INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

SERIES PSCII GAS BOILERS

MODEL CR/DX MANUAL VENT-FREE OR VENTED GAS LOGS CR/DX 18, 24, 30 & CR 24 MOUNTAINEER, CR24 ASPEN LOG SETS

Bosch 80% AFUE Gas Furnace BGS80 Model

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

WHAT TO DO IF YOU SMELL GAS

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

MODEL 42 MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND

United States Stove Company

USER'S INFORMATION MANUAL

INSTALLATION AND OPERATING MANUAL

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

GFP28MLP AND GFP28TLP

Infrared Cabinet Heater Product Manual MODEL: RC9200IT

INSTALLATION INSTRUCTIONS

USERS INSTALLATION OPERATION AND MAINTENANCE MANUAL

USER S INFORMATION MANUAL

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

User s Information Manual

INSTALLATION & OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL

USERS INSTALLATION OPERATION and MAINTENANCE MANUAL. Installer: Please leave this manual with the appliance owner for future reference

UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE

UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE

Transcription:

2001 Lennox Industries Inc. Dallas, Texas 875,010M 05/2001 Supersedes 503,783M 7/99 DT/DTH/DR/DRH MERIT SERIES DIRECT VENT VENTED GAS FIREPLACE/ VENTED GAS FIREPLACE HEATER DT4035 LOUVERED-FACED MODEL SHOWN DR4035 FLUSH-FACED MODEL SHOWN RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Litho USA WH Report No. J20046561 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Extinguish any open flames. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Page 1

Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool. Breathing this may cause lung cancer. (Fiberglass wool is known to the State of California to cause cancer.) Fiberglass wool may also cause respiratory, skin, and eye irritation. To reduce exposure to this substance or for further information, consult material safety data sheets available from address shown below, or contact your supervisor. Lennox Industries Inc. P.O. Box 799900 Dallas, TX 75379-9900 USA If overheating occurs or if gas supply fails to shut off, shut off the manual gas valve to the appliance before shutting off electrical supply. Do not use this furnace if any part has been underwater. Immediately call a qualified service technician to inspect the furnace and to replace any part of the control system and any gas control which has been under water. CAUTION Before attempting to perform any service or maintenance, turn the electrical power to unit OFF at disconnect IMPORTANT Any additions, changes, or conversions required in order for the appliance to satisfactorily meet the application needs must be made by a Lennox service technician using factory specified and approved parts. Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Important Directions This appliance is intended only for use as indicated in this manual and in the installation instructions. Under no circumstances should this fireplace be used to burn wood, paper, or other combustibles of any kind. The appliance will emit an odor for the first 10 to 12 hours of operation. Make sure the room is well-ventilated and the burner is set for high flame operation (if applicable) during this period. Surface temperatures on the appliance are very high. Make sure that both children and adults are aware of the danger of burns or clothing ignition. Do not leave children unsupervised in the room with the appliance. Keep clothing, draperies and furniture well away from the front of the appliance. Do not leave damp or wet clothing or other flammable material to dry on or near the appliance. If for any reason the glass frame is removed, all three securing screws must be replaced and tightened securely before the unit is put back into operation. Do not use this appliance if any part has been under water. Call a qualified service technician to inspect the appliance and replace electrical components. The control access panel becomes hot during unit operation, and must be opened with care. Refer to figure 1. Service, including cleaning inside fire box, should be done by a qualified service technician. The appliance should be inspected and cleaned annually by a qualified service technician. Service should include a thorough inspection of the pilot and burner flame. The vent termination should also be inspected for any blockage. Clean inside and outside glass surfaces, and any other of the appliance s outside surfaces, using a mild detergent/water solution and a soft cloth. DO NOT use abrasive cleansers which might scratch these surfaces. DO NOT attempt to clean these surfaces when the appliance is operating or they are hot to the touch. Glass cleaner is available as Lennox part number 19N74. Service and cleaning of internal components must be performed by a qualified service technician. Do not operate the appliance with glass removed, cracked or broken in any way. Glass must be replaced by a qualified service technician. Page 2

Lighting Information and Operation If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. Use only your hand to turn the gas control knob(s). Never use tools. If the knob will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. PLACING UNIT INTO OPERATION (Millivolt Valves with Piezo Ignitor) Fireplaces which include a millivolt valve are equipped with a pilot which must be lit by a Piezo ignitor (red ignitor button). When lighting the pilot, follow these instructions exactly. GAS VALVE OPERATION - Millivolt Valve (Figure 2) 1- STOP! Read the safety information at the beginning of this section. 2- In applications using an optional appliancemounted OFF appliance-mounted switch and leave OFF. Turn OFF wall-mounted switch or set thermostat to lowest switch - Turn OFF appliance-mounted 3 - Turn off all electrical power to appliance. TO OPEN THE CONTROL ACCESS PANEL The control access panel becomes hot during unit operation, and must be opened with care: Insert the tip of a finger of each hand (with the back of the hands toward the panel) into the cutout in the bottom of the panel at the positions shown, and rotate the panel down. FIGURE 1 4 - Open the control access panel. See figure1. Push in gas control knob slightly and turn clockwise to OFF. NOTE - Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly. Do not force. 5 - Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you do not smell gas go to next step. 6 - Depress partially and turn gas valve knob counterclockwise to PILOT. 7 - Push control knob in until it stops and hold knob in this position. Immediately light the pilot by pushing the red Piezo ignitor button. Continue to depress control knob for 25 seconds after the pilot is lit. Release knob. It should pop back up. Pilot should remain lit. If pilot goes out, repeat steps 5 through 10. MILLIVOLT GAS VALVE (Optional manually-modulated gas valve shown) HI/LO FLAME ADJUSTMENT KNOB CONTROL KNOB GAS VALVE SHOWN IN PILOT POSITION FIGURE 2 8 - Depress partially and turn gas valve knob counterclockwise to ON. 9 - Restore electrical power to appliance (if applicable) 10- In applications using an optional appliancemounted 11- Close the control access panel. NOTE - If gas valve is turned to OFF from ON or PILOT while appliance is in operation, gas valve will latch in OFF position for 25 seconds. TURNING OFF GAS TO UNIT 1- TurnOFF appliance-mounted switch, and in addition, if wall-mounted switch or thermostat is used, turn OFF wall-mounted switch or set thermostat to lowest 2 - Turn off all electrical power to appliance. 3 - Open the control access panel. See figure1. 4 - Push in gas control knob slightly and turn clockwise to OFF. Do not force. 5 - Close the control access panel. Page 3

PLACING UNIT INTO OPERATION (Electronic Gas Valves) Fireplaces equipped with an ignition device which will automatically light the burner. Do not try to light the burner by hand. Follow these instructions exactly. GAS VALVE OPERATION- Electronic Valve (Figure 3) 1- STOP! Read the safety information at the beginning of this section. 2- In applications using an optional appliancemounted OFF appliance-mounted switch and leave OFF. Turn OFF wall-mounted switch or set thermostat to lowest switch - Turn OFF appliance-mounted 3 - Turn off all electrical power to the appliance. 4 - This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5 - Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you do not smell gas go to next step. ELECTRONIC GAS VALVE (Optional manually-modulated gas valve shown) HI/LO FLAME ADJUSTMENT KNOB FIGURE 3 6 - Restore electrical power to the appliance. 7- In applications using an optional appliancemounted 8 - If the appliance will not operate, follow the instructions to turn off gas to unit and call a service technician or gas supplier. TURNING OFF GAS TO UNIT 1- TurnOFF appliance-mounted switch, and in addition, if wall-mounted switch or thermostat is used, turn OFF wall-mounted switch or set thermostat to lowest 2 - Turn off all electrical power to appliance. 3- TurnOFF gas supply at main manual shut-off valve located near the fireplace. PLACING FIREPLACE INTO OPERATION 1- In applications using an optional appliancemounted OFF appliance-mounted switch and leave OFF.Turn Millivolt models only, and in applications without optional appliance-mounted or optional wallmounted ON/OFF switch or optional thermostat - Depress gas valve knob partially and turn counterclockwise to ON. 2- Optional standard blower, if installed, will energize immediately. Burner tube will ignite in approximately three to five seconds. Optional deluxe blower, if installed, will self-energize when a comfortable minimum temperature has been reached. NOTE - Immediately after burner tube ignites, condensate may temporarily fog glass. This is normal. Fog will clear as soon as temperatures within the fire box rise. If droplets continue to form after 15 minutes of operation on a highflame setting, contact a qualified service technician. NOTE - During the initial operation of the appliance, a white film my form on the inside of the glass. This is normal. If this occurs, clean the glass after the first 5 hours of use. Page 4

Burner Flame Adjustment (Optional Feature) The burner flame on this appliance may be adjusted at the gas valve to obtain the desired heating output. Burner flame color varies with the different log sets and burners available. In most cases the flame will be blue at start-up and turn yellow after 5 to 10 minutes of operation. The burner flame should be inspected at the beginning of each heating season and burner tube should be cleaned by a service technician, if necessary. Blower Operation (Deluxe models) The optional deluxe blower may be controlled by a rheostat (provided with the deluxe blower) field-mounted remotely or on the appliance panel. The blower speed selected should approximate the heat output adjustment at the gas valve. A high blower speed matched with a low heat output can lead to condensation. Vent Termination Inspection Annually (before the heating season) inspect the appliance vent termination for any obstructions. If any are found, remove them. Contact your Lennox dealer for a periodic inspection by a qualified service technician. Service Reminder Call your Lennox service technician if unit is inoperative. Before calling, always check the following to be sure service is required. 1 - Check ON/OFF appliance-mounted switch (if applicable) or wall-mounted switch (if applicable) to make sure it is in ON position. 2 - Check room thermostat, if applicable, for proper 3 - Is pilot lit? 4 - Is gas valve in ON position (millivolt units)? 5 - Is gas turned ON at meter? 6 - Is manual main shut-off valve open? 7 - Is electrical power turned ON to the appliance (if applicable)? Contact your local independent Lennox dealer for replacement parts. To ensure the safe operation of your Lennox gas appliance and to keep it in peak operating condition year after year, contact your independent Lennox dealer about a planned service program. Page 5