T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Similar documents
BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors

3M Overhead Ionizing Blower 991A

Critical Environment Ionizing Blower. Model 5810i. User s Manual

Bench Top Ionizer Installation, Operation and Maintenance

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

IONIZING AIR BLOWER INSTRUCTION MANUAL

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

3 963/963E Benchtop Air Ionizer Instructions

OPERATION INSTRUCTION

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Chargebuster Ion Gun Installation, Operation and Maintenance

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

Chargebuster Ion Gun Installation, Operation and Maintenance

3M Benchtop Air Ionizer 963E. User s Guide

RangerNET Network Ready Constant Monitor Model CM2815

- Oscillating Table Model Fan

CRITICAL ENVIRONMENT (C/E) SERIES OVERHEAD IONIZER OWNER S MANUAL

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance

Torrena 42 Ceiling Fan

Ionizer (Static Remover) STABLO-EX Instruction Manual

Camarillo 52 Ceiling Fan

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

INSTALLATION FLOOR REGISTERS WALL REGISTERS

24 & 30 Quiet Design Oscillating Wall Mount Fan

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

20 High Velocity Fan with 135 Tilt Head

Thanks for shopping with Improvements! Deco Breeze 16 Deco Floor Standing Fan - Sutter Item #472969

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

52 CEILING FAN. Owner s Manual Models #50336, 50337

HIGH VELOCITY METAL WALL MOUNT FAN 20" AMPS: 1.2 / WATTS: 140 / VOLT: 120 READ AND SAVE THESE INSTRUCTIONS

16 Stand Fan with Remote Control Model No: FS3-40R-30

Lifetime Limited Warranty

SUTTON 52 CEILING FAN

INSTRUCTIONS FOR OPERATION AND CARE OF

Instruction Leaflet. Read instructions before operating. Retain for future reference.

18 INCHES, OSCILLATING STAND FAN

Instruction Manual and Warranty

Lifetime Limited Warranty

Lifetime Limited Warranty

Operating Instructions & Parts Manual Models 99533, 99532

OPERATING INSTRUCTIONS

GA3650TB Blower Accessory

30-YEAR LIMITED WARRANTY

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Lifetime Limited Warranty

BATTERY POWERED BACKPACK VACUUM

ST. KITTS CEILING FAN

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Owner s Manual. Terpene Trap CF 1000

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

ITEM # SAIL STREAM CEILING FAN MODEL #40048

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

TOUCHDOWN 48 CEILING FAN

Gfp 400 Series August Gfp 463 TH. Please read this manual carefully before operating!

ITEM # SAIL STREAM CEILING FAN MODEL #41695

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

OWNER'S MANUAL RSL MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local:

Larson by Hampton Bay

64&3 (6*%& Distributed by! ALDI, INC.! Batavia, IL 60510!

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Instruction Leaflet. Read instructions before operating. Retain for future reference.

SPRINGHILL 44 CEILING FAN

60In. Ceiling Fan. Owner s Manual

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

USER MANUAL. PEDESTAL FAN (16 Inch)

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

48 TAYLOR CEILING FAN

YOUR PORTABLE AIR PURIFIER

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

USER S OPERATING AND INSTRUCTION MANUAL

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

52 BAYTOWNE CEILING FAN

Vari-Cyclone Ceiling Fans

TACH-IT MODEL #3568 SEMI-AUTOMATIC TWIST TIE MACHINE OPERATION MANUAL AND PARTS LIST

GAS-Mate. Combustible Gas Leak Detector

ELSTON 52 CEILING FAN

CARMEL 48 CEILING FAN

THE MW-1 Cyclone RECORD CLEANING MACHINE

20 High velocity Air

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

100In. High Volume Ceiling Fan. Owner s Manual

Stand Fan. English. Owner s Guide. Model F R

L I F E T I M E W A R R A N T Y L I F E T I M E W A R R A N T Y 52 VERANDA

Transcription:

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L BFN 801 Ionizing Blowers Instruction Manual

Contents BFN 801 Description 2 Features 2 Specification 2 Operation Guide 4 Power 4 Bracket Adjustment 4 Maintenance 4 Cleaning 5 Disassembly 6 Periodic Verification 8 BFN Series Ionizers Description Dependable, Balanced and Fast. BFN AC ionizers, from Transforming Technologies, are built to last. Reliable AC ionization technology is combined with superior mechanical design to assure years of optimal static neutralizing performance. A full 1 year warranty. CE certification. All BFN AC ionizers use titanium alloy emitter points for long life.

All BFN series AC ionizing blowers are designed for safe operation under normal use. Safety switches under the front and rear removable finger guards shut off the unit, protecting the operator during maintenance. Do not operate BFN series products in flammable or explosive environments. Do not insert foreign objects into the air inlet or outlet. Make certain the BFN ionizer is properly grounded before operation. Disconnect the BFN ionizer from any power source before removing the finger guards. Do not open or attempt to repair any BFN series product. Breaking the manufacturing seal will void warranty. BFN 801: Bench top Blower Model The BFN 801 bench top ionizing blower, with inherently stable AC technology, provides excellent balance and rapid charge decay for secure workstation protection. Designed to protect most sensitive electronic devices, the BFN 801 uses corona ionizing technology to continuously produce a balanced output of positive and negative air ions. Features Stable AC ionization output Integrated emitter cleaning device Variable fan speed control Removable finger guards with auto shut-off sensor 1

Power Input 120 V AC, 60 Hz., 36W 220 V AC, 50Hz. Dimensions 7.0 W x 10.25 H x 3.75 D (17.8W x 26.0H x 9.5D cm) Weight 8.25 lb (3.75 kg) Product Specifications Air Volume 50 CFM 100 CFM (low high) RH Operating Range 20-60%, non-condensing Audible Noise 44dB(A) (Distance 1 meter) Enclosure Steel Finish Powder coat, off white Approvals CE Tested in accord with ANSI/ESD STM3.1-2006 Packing list: BFN 801 Charge Decay Efficiency (Discharge Time) Effective Coverage 1 x5 area coverage Balance 0 +10 volts Decay Time < 2 seconds @12, 1000V- 100V, fan speed on high Temperature 32-122 F (0-50 C) Indicators ON/OFF status light indicator, detects presence of HV on emitter points BFN 801 ionizing blower Power cord Instruction manual Certificate of Conformance Black: Hi Fan Speed Red: Low Fan Speed Discharge times determined as per EOS/ ESD Standard No.3 using 6 x6 20 pf charge plate monitor. Discharge times are in seconds from 1000V to 100 V, Discharge times are slightly longer for 230V, 50 Hz 5 7 9 1 1 1 2 3 1. 2. 4 6 3 6 1 1 5 7 9 1 1 1 2 3 1 2 3 4 5 2

1. Power Connection Operating guide Install the ionizer into the proper position and connect the power cord. Rotate the on/off, fan speed knob clockwise to turn on the unit. Continue rotating the knob to achieve the desired fan speed. 2. Bracket Adjustment To adjust the angle of operation of the BFN 801 ionizer, loosen the mounting knobs that secures the bracket and loosen the left gear completely. Now adjust the unit to the required angle and re-tighten the knobs. Note: Failure to loosen the bracket knobs sufficiently may result in damage to the bracket mounting system. 3. Periodic Maintenance The only maintenance required for BFN series ionizers is the periodic cleaning of the emitter points, inlet and outlet finger guards and the fan assembly. Emitter point cleaning affects the static decay ability of the ionizer and is important for maintaining its optimal performance. Emitter point cleaning: All BFN series ionizing blowers include an integrated emitter point cleaning brush on the inlet fan guards. Turn the emitter point cleaners clockwise, then counter clockwise several times, until points are clean. When finished, return the point cleaning brush to its resting position. Internal fan cleaning: All BFN series ionizing blowers offer convenient cleaning of the internal fan assembly. Use the following procedure to maintain cleanliness. Note: Always disconnect the ionizer from the power source prior to internal cleaning. 3

Air outlet disassembly A. Press the button on the bottom of the plastic front cover upwards and make the lower portion of the fan guard separate from the metal housing. B. Lightly pull the front cover downwards until it separates from the blower. C. Completely remove cover and set aside. A B C Air Inlet Disassembly A. Press the recessed release point on the bottom of the plastic rear cover using a flat blade screwdriver. B. Gently push the cover upwards. C. Lift the rear cover up and away from the metal casing. After removing both front and rear fan guards, the emitter points and fan assembly will be unobstructed, for easy deep cleaning. Use a soft brush, Isopropyl Alcohol and compressed air to remove any foreign matter. Note: The frequency of cleaning required for optimal performance from BFN ionizers depends on the environment in which the BFN series ionizer operates. 4

Air Outlet Assembly A. Slide the slot on the upper back side of the front fan guard onto the metal case. B. Push upward from the bottom of the front fan and gently press into the metal casing, until attached. C. Press the sides of the cover in to make sure cover is securely attached. A B C Air Inlet Assembly A B C D A. Line up the clips on the rear fan guard with the slots on the BFN fan housing. B. Push the rear fan guard into the corresponding slots. C. Slide the two sides of the rear fan guard down. D. Lightly pull the very bottom of the rear fan guard downward with your thumb to lock it securely. Caution: BFN series products have safety relay switches where the front and rear fan guards attach to the unit. These relays disable the fan/ionizer operation when either fan guard is removed. Take care when attaching the fan guards to assure proper functioning of the product. 5

Periodic Verification: BFN ionizer have no user serviceable parts and the technology requires no calibration because of the inherently stable ionization output from the AC emission. Periodic verification is recommended, per ANSI/ESD SP3.3-2006 Periodic Verification of Air Ionizers. Verification frequency may be set by the individual user, but is recommended to be not less than one time per year. Service and Warranty Transforming Technologies, LLC provides a limited warranty for the BFN Series Ionizers. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident. In no event shall Transforming Technologies be liable for collateral or consequential damages. About Transforming Technologies Since 1998, Transforming Technologies has helped electronic manufacturing facilities to protect their products and processes from the many serious problems associated with static electricity. Transforming Technologies offers a wide range of unique and outstanding products to detect, protect, eliminate and monitor electrostatic charges. Our products are integral components of an effective static control program. 3719 King Rd Toledo, OH 43617 P: 419-841-9552 F: 419-841-3241 info@transforming-technologies.com