CONDENSERS 119. Allihn / Cold Finger / Dewar. Allihn Micro Condenser. Accessories. Allihn Condensers with Full Length Joints. Cold Finger Condensers

Similar documents
CONDENSERS AND DISTILLATION COLUMNS

160 EXTRACTION. Liquid/Liquid Extraction Apparatus. Continuous Liquid/Liquid Extraction with Built-in SLOW-DRY Concentrator

Midi-Vap Features

Vacuum Equipment. Manifolds. Traps. Pumps. Adapters. Easy to assemble Ace-Safe connector versions. O-Ring connections. Added safety and versatility

Chemistry Materials Separation Processes

Shop. Item Information. Rotavapor R-300 B-305, SJ24/40, C, P+G, WB, 110V. Send item information. Show item in shop. Add item to cart.

1 L Rotary Vacuum Evaporator Instruction Manual

Standard Operating Procedure for Oil & Grease Method EPA1664A

APPENDIX A: MICROSCALE APPARATUS AND TECHNIQUES A.1 CRAIG TUBES: RECRYSTALLIZATION

Rotary Evaporator Replacement Glassware

LABORATORY GLASS APPARATUS

Models Goldfisch Fat Extraction Apparatus

Rotary Evaporator Replacement Glassware

Each unit is also provided with an easy to use Can be orientated for left or right handedness

Evaporators, Rotary. Total concentration... technology and performance in harmony 13

CENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.

Training Papers Distillation with a Rotary Evaporator

Experiment 4: Purification of Liquids by Distillation

Two Models Available!

Evaporators. In this section. Rotary Evaporators Crystalisation Distillation Drying Reflux Solution Concentration Volatiles Glassware

Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD.

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Rotary Evaporator Replacement Glassware

Glassware for Your Lab

ROTARY EVAPORATORS EVAPORATION SOLUTIONS

BUREAU OF INDIAN STANDARDS. Draft Indian Standard. METHOD FOR DETERMINATION OF DISTILLATION RANGE AND DISTILLATION YIELD (Second Revision of IS 5298)

Science Lab Equipment

Rotary Evaporators, Heidolph

OPSIS LiquidLINE SoxROC Extraction Unit

Rotary Evaporators designed

Owner s Manual. Terpene Trap CF 1000

Hei-VAP Precision. for the highest level of accuracy. Vacuum Pumps. RPM Regulated Vacuum Pumps

VACUUM VALVES AND HOSES

Short Path Distillation Unit. KDL 1 BASIC Version 2015

Laboratory Equipment. Section 1L. Chemistry I & II

Contents. BÜCHI Glass Oven B-580. Contents

Kshitij Innovations.

McNeil Group University of Michigan. MBraun Glovebox. Preparing Items To Be Brought Into the Glovebox

MIDI-VAP 4000 Distillation Systems

Chemistry - Tools for chemistry

Test Tube Rack. Test Tube

Verd_GB_ FH :22 Uhr Seite 1 C M Y CM MY CY CMY K Rotary Evaporators Probedruck

24 position personal synthesiser for parallel solution phase and solid supported reagent based chemistry

liquid heating The density of the liquid changes as its temperature increases. This causes energy to be transferred throughout the liquid.

HEATING AND VENTILATION

Verd_GB_ :55 Uhr Seite 1 C M Y CM MY CY CMY K Rotary Evaporators Probedruck

Water Circulator (Chiller) & Cold Trap

CLASSIC LONG-LIVED VERSATILE FLEXIBLE. LABORATORY HEATERS and CLASSIC APPARATUSES HEATERS KJELDAHL SOXHLET WEIBULL

CLASSIC LONG-LIVED VERSATILE FLEXIBLE. LABORATORY HEATERS and CLASSIC APPARATUSES HEATERS KJELDAHL SOXHLET WEIBULL

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1

Heat can change into other forms of energy and vice versa. Heat is measured in the unit of energy, the joule (J).

Heating and ventilation system,

Providing clean air in your workplace. Fume Extraction Solutions. 99 Washington Street Melrose, MA Phone Toll Free

INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

VANGUARD 245 POST-MIX DISPENSER

Order by phone Order on-line Order by fax Website

Laboratory Equipment. Use of equipment

Arrangements of cold exchangers or cold accumulators in cryogenic separation or liquefaction plants.

REFRIGERANT PIPING

Safety Lab Goggles are required! Apron is optional!

Premium Laboratory Equipment. Chem Tools

Category Name Reference Price with Tax

Classical and Rapid Kjeldahl Systems and Fat and Crude Fiber Apparatus

Lenz The Specialist for Ground Joints

NMR SAMPLING ACCESSORIES CLEANING NMR SAMPLE TUBES

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

DESIGN STANDARDS SECTION 15600

Columns XK 16, XK 26, XK 50 Adaptors AK 16, AK 26, AK 50 INSTRUCTIONS

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

BITUMINOUS DIGITRAC AUTO STABILITY PRESS MARSHALL AUTOMATIC DIGITAL TESTER MARSHALL TESTING MACHINE W/ RECORDER MODELS

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

SECTION REFRIGERANT PIPING

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

AUC Cell Washer. User Manual

INSTALLATION INSTRUCTIONS

Laboratory Techniques

Popular Science Apparatus Workshops Private Limited

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators

Laboratory Evaporation Glassware Decades of expertise in glass manufacturing

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

BLAST-IT-ALL BUMPER BLASTER

Premium Laboratory Equipment HBX EVAPORATION GUIDE

Oil-Sealed Rotary Vane Pumps

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

UNIVERSAL 750 PRE-MIX DISPENSER

WAL-RICH CORPORATION SINCE 1950

Thermo Scientific Modulyo Freeze Dryers

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

Rotary Evaporators, Heidolph

B/R 9600 Packed Column Distillation Systems. Fractional Distillation for the Laboratory and Industry

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS

7911A Constant Temperature Ice Bath. User s Manual

Fountain Classic. Installation and Owner s Manual. Page 16

Scientific Glassware. International Mini Catalogue

Rotary Evaporators. RE100-Pro. LCD Digital Rotary Evaporator. Features:

Installation and Maintenance Instructions

Transcription:

CONDENSERS Manufactured from 33 expansion borosilicate glass to meet rigorous heating and cooling needs for a variety of applications, Kimble condensers are designed to provide a long service life and optimal performance Toll Free: 800.451.4351 International: 865.717.2600

Allihn / Cold Finger / Dewar CONDENSERS 119 Allihn Micro Condenser Used in refluxing operations such as Soxhlet extractions. Component of Soxhlet extraction apparatus 292010 Fits Tubing ID (inches) 283250-0000 19/22 0.25 1 Allihn Condensers with Full Length Used in many refluxing operations. Accessories Description 179700-0814 BEVEL-SEAL Adapters, Joint Size 14/20, Accommodation Range 5-8 mm 1 179750-0814 BEVEL-SEAL, Universal, Inlet Thermometer, Joint Size 14/10, Accommodation Range 5-8 mm, O-Ring Size 108, 15-415, Fits Tubing ID 1/4 1 drip joint at bottom and a Standard Taper outer joint at top Allihn Condensers with Full Length Water- Cooled For use in many refluxing operations, including Soxhlet extractions. Straight outlet tube at top Water-cooled inner drip joint at bottom Cold Finger Adjustable Height Condenser Used to generate a localized cold surface on the exterior of the finger. Commonly used for sublimation, and can also be used in reflux or distillation operations. Offset drip tip Length Below Joint 431000-2420 24/40 200 1 431000-2425 24/40 250 1 431000-2430 24/40 300 1 431000-2440 24/40 400 1 431000-2920 29/42 200 1 431000-2930 29/42 300 1 431500-2430 24/40 325 1 456000-0021 34/45 190 1 456000-0022 45/50 260 1 456000-0023 55/50 300 1 456000-0024 71/60 350 1 456000-0025 103/60 400 1 282010-0000 14/20 150 1 Cold Finger Condensers Used to generate a localized cold surface on the exterior of the finger. Commonly used for sublimation, and can also be used in reflux or distillation operations. 282000-0000 and 518501-0000 have an extended offset lower tip for drop control 479103-0000 does not have extended lower tip Length Below Joint 282000-0000 14/20 100 1 518501-0000 29/42 195 1 479103-0000 45/50 140 1 Dewar Condensers with Sidearm Dewar condenser with large top opening for easy introduction of dry ice, dry ice/alcohol mixtures or liquid nitrogen. These coolants provide rapid condensation of volatile components Sidearm at the top is a full length joint Lower joint will work with 675500 Kem-Klamps or 675300 polyacetal clamps ASTM Capacity (ml) 283400-0000 14/20 200 1 457750-2425 24/40 650 1 info@kimble-chase.com kimblechase.com

120 CONDENSERS Dewar / Friedrich / Graham / HE / Large Capacity Dewar Condensers with Hose Connection Sidearm Dewar condenser used for rapid cooling of volatile solvents. Friedrich Condenser with Take-Off Tube Friedrich condenser suitable for vertical distillation assembly. Large top opening for easy introduction of coolant mixtures such as solid carbon dioxide/alcohol, dry ice/ alcohol, dry ice, or liquid nitrogen Sidearm is a hose connection for attachment to flexible tubing Lower joint will work with 675300 polyacetal Standard Taper clamps Fits Tubing ID (inches) 457500-2420 24/40 0.375 1 457500-2425 24/40 0.5 1 Friedrich Condenser with Sidearm Friedrich condenser specially designed to provide a long vapor path, good heat transfer and anti-flooding characteristics. Molded inner spiral provides surface area for the condensation of the product Inclined outer joint on the side Water inlet and outlet located above ring-sealed inner condensing tube inner drip joint at the bottom borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements 437000-2440 24/40 225 1 437000-2942 29/42 225 1 Friedrich Condenser with Hose Connection Sidearm Friedrich condenser used primarily in reflux mode and Soxhlet extractions. Water inlet and outlet located above ring-sealed inner condensing tube inner drip joint and side outlet for drying tube, etc Molded inner spiral provides surface area for the condensation of the product Cold Finger Length 456250-0021 34/45 190 1 456250-0022 45/50 190 1 456250-0023 55/50 190 1 Molded inner spiral provides surface area for the condensation of the product Designed with 150 mm OD delivery tube for product recovery Full length 24/40 joints ASTM Cold Finger Length 456300-2440 24/40 200 1 Graham Condensers Vapor travels through a coil extending through the length of the condenser and is surrounded by a cooling jacket. outer joint at top inner drip joint at the bottom 439000-2420 24/40 200 1 439000-2425 24/40 250 1 439000-2430 24/40 300 1 439000-2440 24/40 400 1 High Efficiency Condensers Vapors travel downward and condense in this highly efficient and compact concentrator. Full length 24/40 joints Condensate drains through side tube with Standard Taper inner joint to a suitable receiver Vacuum connection provided for reduced pressure operation, if desired ASTM Large Capacity Condensers This large capacity, highly efficient condenser is ideal for pre-pilot and pilot plant operations. Full length 29/42 joints outer joint at the top inner drip joint at the bottom ASTM 444500-2420 24/40 315 1 444500-2425 24/40 365 1 458000-2950 29/42 660 1 Toll Free: 800.451.4351 International: 865.717.2600

Liebig / Reflux CONDENSERS 121 Liebig Medium Length Condenser with 14/20 Design eliminates the use of bulbs where holdup is likely to occur. Lower inner drip joint is designed to extend into 287800-0000 distillation receiver Design conforms to NSN 6640-01-346-9222 282210-0000 14/20 178 1 Liebig Condenser with Full Length Water- Cooled 24/40 Water-cooled inner drip and outer joints provide the maximum condensing surface. Full length 24/40 joints Hose connections accept 3/8 ID flexible tubing 448000-2410 24/40 220 1 448000-2420 24/40 320 1 448000-2430 24/40 420 1 Liebig Condenser with outer joint at the top inner drip joint at the bottom Hose connections accept 3/8 ID flexible tubing Ref: ASTM Method D322 447000-2410 24/40 100 1 447000-2420 24/40 200 1 447000-2425 24/40 250 1 447000-2430 24/40 300 1 447000-2440 24/40 400 1 447000-2920 29/42 200 1 Coil-Type Reflux Condenser with Two Upper Hose Barbs Tightly wound coil provides enough surface area to condense high vapor pressure solvents like hexane. With an internal, coil-type cold finger outer joint at the top, inner drip joint at the bottom 283000 does not have a drip joint Two hose connectors at the top for water inlet and outlet Ref: ASTM Method D94, D95 283000-0000 14/20 200 1 283010-0000 19/22 225 1 457000-0125 24/40 290 1 457000-0175 24/40 340 1 457000-0225 24/40 390 1 KIMAX Liebig Condenser with Full Length 24/40 KIMAX one-piece sealed unit with a outer joint at the bottom and a inner joint at the top. Inlet end is sloped to avoid trapping condensate Drip tip is provided at the lower end Hose connections accept 5/16 inch ID flexible tubing Suitable for use with ASTM D849 ASTM 18140-400 24/40 400 1 Coil Type Reflux Condenser with Removable Hose Connections Detachable polypropylene hose connections provide a safe and easy way to connect and disconnect tubing. With an internal, coil-type cold finger x Jacket Length Top Joint 283055-0000 14/20 x 100 Offset 1 283100-0000 14/20 x 100 1 457100-0175 24/40 x 150 1 457100-0225 24/40 x 250 1 info@kimble-chase.com kimblechase.com

122 CONDENSERS Reflux / Solvent Saver / West Coil-Type Reflux Condenser with Two Upper Hose Barbs and Angled Outer Joint Coil-type condenser for greater cooling capacity. Hook above lower joint for use with a 675500 KEM-KLAMP 675000 series polyacetal clamps may also be used ASTM 283050-0000 14/20 240 1 457050-0000 24/40 370 1 Solvent Recovery Condensers A versatile solvent condenser designed to recover solvents escaping during evaporative concentrations. It allows users to work safely outside of a hood. Upper, lower, and lower offset connectors for 3/8 ID tubing Ref: Analytical Chemistry Vol.47, No.11, Pg.1879, September 1975 ASTM Bottom 547400-0000 24/40 Hose Connections Upper, Lower, Lower Offset 1 Coil-Type Reflux Condenser with Upper and Lower Hose Barbs Reflux condenser has efficient non-flooding design. Reflux condenser with a water-cooled inner coil sealed to top and bottom hose connectors Full length 24/40 joints ASTM 456900-2024 24/40 375 1 456900-3024 24/40 475 1 Solvent Saver for Beakers and Funnels This device offers a unique broad-surface, water-cooled condenser used on top of beakers and funnels for concentrating and refluxing liquids. Convex surface with center drip effectively channels condensed material back into the boiling liquid An extension rod allows easy clamping and positioning by hand ASTM Capacity (ml) Diameter 459000-0022 2000 150 1 Jacketed Coil Type Reflux Condenser Condenser with water-cooled outer jacket to increase condensation capability. Full length 24/40 joint Reflux condenser with an internal coil-type cold finger Vapors spiraling upward are condensed on the inner wall of the jacket and on the outer surface of the coil 457270 has a outer joint at the top, a inner drip joint at the bottom and two hose connectors at the top for water inlet and outlet 457250 has a straight outlet at the top, a Standard Taper inner drip joint at the bottom and two hose connectors at the top for water inlet and outlet 457250-0225 24/40 420 1 457270-2425 24/40 420 1 West Condenser with Medium Length Useful for refluxing and distillation assemblies. The narrow annular space of the West design provides high cooling efficiency due to the increased flow rate of the cooling medium Medium length joints Condensate is not restricted with this design ASTM 282550-0000 14/20 110 1 282460-0200 19/22 200 1 Toll Free: 800.451.4351 International: 865.717.2600

West / FLOW-WATCHMAN CONDENSERS 123 KIMAX West Condenser with Medium Length KIMAX one-piece sealed unit with a outer joint at the inlet and a inner joint drip tip at the outlet. Inlet end is sloped to avoid trapping condensate. The narrow annular space of the West design provides high cooling efficiency due to the increased flow rate of the cooling medium. Medium length joints Inner tube is light-walled with a small diameter jacket to keep minimal space between jacket and tube Hose connections accept 5/16 inch ID flexible tubing borosilicate glass conforming to USP Type I and ASTM E438, Type I, Class A requirements West Condenser with Full Length Water-Cooled 24/40 Condenser with water-cooled inner and outer joints to provide maximum condensing surface. Upper joint is jacketed Full length 24/40 joints 452750-2430 24/40 445 1 18185-1420 14/20 200 1 Jacketed West Condenser Useful for refluxing and distillation assemblies. Condensate is not restricted with this design. The narrow annular space of the West design provides high cooling efficiency due to the increased flow rate of the cooling medium Indentations near base of jacket for support packing 14/20 joints ASTM 282555-0000 14/20 80 1 FLOW-WATCHMAN Flowmeter Keep an eye on cooling water with the Kimble Flow- Watchman - a device for the visual indication of liquid flow. Molded of clear polycarbonate with an inert nylon indicator ball Flow indication is visible from a distance Usable with water down to a flow range of approximately 100 ml/minute, which is adequate for even the smallest cold finger condensers The upper flow limit is in excess of 1 liter/minute Unit operates in any position Lightweight all-plastic construction Requires no auxiliary support Fits Tubing ID (inches) Max Pressure (psi) 626250-0000 0.25 10 1 West Condenser with Full Length 24/40 The narrow annular space of the West design provides high cooling efficiency due to the increased flow rate of the cooling medium. Full length 24/40 joints outer joint at the top and Standard Taper inner drip joint at the bottom ASTM 452000-2410 24/40 100 1 452000-2420 24/40 200 1 452000-2430 24/40 300 1 info@kimble-chase.com kimblechase.com

124 CONDENSERS Toll Free: 800.451.4351 International: 865.717.2600

info@kimble-chase.com kimblechase.com