Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Similar documents
Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioners Technical Data

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Air Conditioners Technical Data

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioners Technical Data

Air Conditioners Technical Data

Air Conditioners Technical Data

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioners. Technical Data FTXS-G

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Fan Coil Units. Technical Data FWC-BT/BF

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Air Conditioners Heating & Cooling

Concealed ceiling units

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Purifiers. Technical Data MC70L

Fully Flat Cassette Design & Genius in one

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioners Heating & Cooling

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Heating. Technical Data EEDEN ERRQ-AY1

Air conditioners, heating & cooling for shops,restaurants and offices

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data FTY-H

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Air Conditioners Heating & Cooling

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Air Conditioners Heating & Cooling

Air conditioners, heating & cooling for the retailmarket and offices

Pure comfort & design

Air Conditioners. Technical Data FBQ-C

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Daikin air conditioners for shops, restaurant and offices

DAIKIN Air Handling Unit Modular

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B

Air conditioners Heating & Cooling

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Air conditioners Heating & Cooling

AIR CONDITIONERS, HEATING & COOLING for your home

w w w. d a i k i n. e u ATXS-E

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Air conditioners Heating & Cooling

Pure comfort & design

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Air Conditioners Heating & Cooling

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioners Heating & Cooling

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

for small rooms in multi application

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Pure comfort & design

Remote control infrared ARC433B76 ARC433A8 ARC433B69

for your home FLXS-B Flexi type unit air to air heat pumps

Daikin air conditioners for your home

Pure comfort & design

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-A

Air conditioners Heating & Cooling

Concealed ceiling units

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Air conditioners Heating & Cooling

Our mission: beating the winter cold

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Daikin air conditioners for your home, shops, restaurants and offices

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Daikin air conditioners for your home

Daikin leads the way:

EEDEN technical data EKRTR. Altherma. Altherma

Air conditioners Cooling only

for the retail market, hotels, restaurants and offices

Transcription:

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFAA2VEB > FFAA2VEB

TABLE OF CONTENTS FFA-A 1 Features............................................................. 2 2 Specifications....................................................... 3 Technical Specifications............................................. 3 Electrical Specifications.............................................. 4 3 Options............................................................... 5 4 Dimensional drawings............................................. 6 5 Centre of gravity.................................................... 8 6 Piping diagrams.................................................... 9 7 Wiring diagrams................................................... Wiring Diagrams - Single Phase.................................... 8 Sound data......................................................... 11 Sound Pressure Spectrum.......................................... 11 9 Air flow patterns................................................... 13 Air Flow Pattern - Cooling........................................... 13 Air Flow Pattern - Heating........................................... 17 Split - Sky Air FFA-A 1

c yt tk i a n l -f r yt o lo i - dl nf up F I 1 Features Indoor Unit FFA-A S U 1 A A SUnique design in the market that integrates fully flat into the ceiling Fully flat integration in standard architectural ceiling tiles, leaving only 8mm Remarkable blend of iconic design and engineering excellence with an elegant finish in white or a combination of silver and white Unified indoor unit can be combined with R-32 and R-4A outdoor units, symplifying stock Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-4A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge Two optional intelligent sensors improve energy efficiency and comfort. Individual flap control: flexibility to suit every room layout without changing the location of the unit! Reduced energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump Optional fresh air intake Branch duct discharge allows to optimize air distribution in irregular shaped rooms or to supply air to small adjacent rooms Standard drain pump with 6mm lift increases flexibility and installation speed Infrastructure cooling Inverter Presence & floor sensor Home leave operation Fan only Draught prevention Auto coolingheating changeover Whisper quiet Ceiling soiling prevention Individual flap control Vertical auto swing Fan speed steps Dry programme Air filter Weekly timer Infrared remote control Wired remote control Centralised control Auto-restart Self diagnosis Drain pump kit Twin/triple/ double twin application Multi model application VRV for residential application 2 Split - Sky Air FFA-A

2 Specifications Indoor Unit FFA-A 2-1 Technical Specifications FFA25A FFA35A FFAA FFAA Casing Material Galvanised steel plate Dimensions Unit Height/Width/ mm 2/575/575 Depth Packed unit Height/Width/ Depth mm 2/686/597 Weight Unit kg 16.0 17.5 Packed unit kg 18.0 19.0 Decoration panel Model BYFQC2W1W Colour White (N9.5) Dimensions HeightxWidthxDe mm 46x6x6 pth Weight kg 2.8 Decoration panel 2 Model BYFQC2W1S Colour SILVER Dimensions HeightxWidthxDe mm 46x6x6 pth Weight kg 2.8 Decoration panel 3 Model BYFQB2W1 Colour White (RAL) Dimensions HeightxWidthxDe mm 55x0x0 pth Weight kg 2.7 Decoration panel 4 Model BYFQB3W1 Colour WHITE (RAL) Dimensions HeightxWidthxDe mm 55x0x0 pth Weight kg 2.7 Heat exchanger Inside length mm 1,295 1,248 Outside length mm 1,342 Rows Quantity 2 3 Fin pitch mm 1. Passes Quantity 5 7 Face area m² 0.29 0. Stages Quantity 12 16 Empty tubeplate Quantity 0 hole Fin Type Cross fin coil (multi slit fins and hi-xa tubes) Air filter Type Resin net Fan Model QTS32D15M Type Turbo fan Quantity 1 Air flow rate Cooling High m³/min 9.0.0 12.0 14.5 cfm 318 353 424 512 Mediu m³/min 8.0 8.5.0 12.5 m cfm 282 0 353 442 Low m³/min 6.5 7.5 9.5 cfm 2 265 336 Heating High m³/min 9.0.0 12.0 14.5 cfm 318 353 424 512 Mediu m³/min 8.0 8.5.0 12.5 m cfm 282 0 353 442 Low m³/min 6.5 7.5 9.5 cfm 2 265 336 3 2 Split - Sky Air FFA-A 3

2 Specifications Indoor Unit FFA-A 2 2-1 Technical Specifications FFA25A FFA35A FFAA FFAA Fan motor Quantity 1 Model ARW54DK Speed Steps 3 Cooling High/ rpm 653/447 748/481 0/581 Low Heating High/ Low rpm 653/447 748/481 0/581 Output High W Sound power level Cooling dba 48 51 56 Heating dba - Sound pressure level Cooling High/Medium/ dba 31.0/28.5/25.0 34.0/.5/25.0 39.0/34.0/27.0 43.0/.0/32.0 Low Heating High/Medium/ Low dba 31.0/28.5/25.0 34.0/.5/25.0 39.0/34.0/27.0 43.0/.0/32.0 Control systems Infrared remote control BRC7EB5W (standard panel) / BRC7F5W (white panel) / BRC7F5S (grey panel) Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7 Refrigerant Type R-32 / R-4A Piping connections Sound absorbing insulation Foamed polyurethane Liquid Type/OD mm Flare connection/6,35 Gas Type/OD mm Flare connection/9.52 Flare connection/12. Drain VP (I.D. /O.D. 26) Heat insulation Foamed polystyrene/polyethylene Standard Accessories : Installation and operation manual; Quantity : 1; Standard Accessories : Drain hose; Quantity : 1; Standard Accessories : Hose band; Quantity : 1; Standard Accessories : Washer for hanger bracket; Quantity : 8; Standard Accessories : Screws; Quantity : 4; Standard Accessories : Thermal insulation tube; Quantity : 2; Standard Accessories : Sealing material; Quantity : 4; Standard Accessories : Tie-wraps; Quantity : 7; 2-2 Electrical Specifications FFA25A FFA35A FFAA FFAA Power supply Phase 1~ Frequency Hz Voltage V 2-2 4 Split - Sky Air FFA-A

3 Options 3-1 Options Indoor Unit FFA-A 3 FFA-A 1: 2: 3: 4: 5: 6: 7: 8: 9: : 11: Option kit Product name Compatibility Decoration panel - Standard BYFQB2W1 - - - Decoration panel - Standard BYFQB3W1 - - - Decoration panel - White BYFQC2W1W - - - Decoration panel - Silver BYFQC2W1S - - - Sensor kit - White No Yes No BRYQA2W3 Sensor kit - Silver No No Yes BRYQA2S3 Air discharge outlet sealing member BDBHQ44C Panel spacer Yes No No KDBQ44B Long-life replacement filter KAFQ441BA Fresh air intake kit KDDQ44XA Remote control Infrared type HP Yes No No BRC7EB5W12 Remote control Infrared type HP White No Yes No BRC7F5W12 Remote control Infrared type HP Silver No No Yes BRC7F5S12 Wired remote control BRC1D5282 Wired remote control BRC1E53A78/BRC1E53B79/BRC1E53C711 Simplified remote control (with operation mode selector button) BRC2E52C511 Simplified remote control (without operation mode selector button) BRC3E52C511 Central remote control DCS2B51 Unified ON/OFF controller DCS1B51 Schedule timer DST1B51 Wiring adaptor for electrical appendices KRP1B57 Wiring adaptor for electrical appendices KRP4A53 Wiring adaptor (hour meter) EKRP1B2 Installation box for adaptor PCB KRP1B1, KRP1BA1 Remote sensor KRCS01-4B itouch Controller DCS1C51 Centralised control systems DCC1A51 Intelligent touch controller DCM1A5A Digital input adaptor BRP7A536 The sensing function is not available. The independently-controllable-flaps function is not available. This option cannot be used with RR and RQ models. The independently-controllable-flaps function is not available in combination with RR and RQ models. Included languages are: Language pack 1: English, German, French, Dutch, Spanish, Italian, and Portuguese. With PC cable EKPCCAB3 in combination with the Updater PC software, you can additionally change the language to: Language pack 3: English, Greek, Polish, Russian, Serbian, Slovak, and Turkish. Language pack 2: English, Bulgarian, Croatian, Czech, Hungarian, Romanian, and Slovenian. Only possible in combination with remote control BRC2/3E52C, BRC1E53A/B/C7. Requires installation box for adaptor PCB Included languages are: English, German, French, Italian, Spanish, Portuguese, and Dutch. Included languages are: English, Czech, Croatian, Hungarian, Slovenian, Romanian, and Bulgarian. Included languages are: English, Russian, Greek, Turkish, Polish, Albanian, and Slovak. Language pack 3 of controller BRC1E53C7 is different from that of controller BRC2/3E52C7. / BYFQB2W1 BYFQB3W1 BYFQC2W1W BYFQC2W1S 3D6135 Availability SA FFA25A2VEB FFA35A2VEB FFAA2VEB FFAA2VEB 3 Split - Sky Air FFA-A 5

4 Dimensional drawings 4-1 Dimensional Drawings 4 6 Split - Sky Air FFA-A

4 Dimensional drawings 4-1 Dimensional Drawings 3 4 Split - Sky Air FFA-A 7

5 Centre of gravity 5-1 Centre of Gravity 5 8 Split - Sky Air FFA-A

6 Piping diagrams 6-1 Piping Diagrams Indoor Unit FFA-A 3 6 Split - Sky Air FFA-A 9

7 Split - Sky Air FFA-A 7 Wiring diagrams 7-1 Wiring Diagrams - Single Phase

8 Sound data 8-1 Sound Pressure Spectrum Sound pressure level [db] FFA25A 85 75 65 55 45 35 25 15 NR0 NR5 NR NR15 NR Cooling mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR25 63 125 2 0 00 00 00 00 dba Sound pressure level [db] 85 75 65 55 45 35 25 15 Heating mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR0 NR25 NR5 NR NR15 NR 63 125 2 0 00 00 00 00 dba 3 8 Octave band centre frequency [Hz] Octave band centre frequency [Hz] Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 31 28,5 25 dba 31 28,5 25 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard 2. 3. 4. 5. Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. The operation noise measuring method is in accordance with JISC9612. Measuring location: anechoic chamber 3D9998 FFA35A Sound pressure level [db] 85 75 65 55 45 35 25 15 NR0 NR5 NR NR15 NR Cooling mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR25 63 125 2 0 00 00 00 00 dba Sound pressure level [db] 85 75 65 55 45 35 25 15 Heating mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR0 NR25 NR5 NR NR15 NR 63 125 2 0 00 00 00 00 dba Octave band centre frequency [Hz] Octave band centre frequency [Hz] Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 34,5 25 dba 34,5 25 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard 2. 3. 4. 5. Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. The operation noise measuring method is in accordance with JISC9612. Measuring location: anechoic chamber 3D9999 Split - Sky Air FFA-A 11

8 Sound data 8-1 Sound Pressure Spectrum FFAA 8 Sound pressure level [db] 85 75 65 55 45 35 25 15 NR0 NR5 NR NR15 NR Cooling mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR25 63 125 2 0 00 00 00 00 dba Sound pressure level [db] 85 75 65 55 45 35 25 15 Heating mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR0 NR25 NR5 NR NR15 NR 63 125 2 0 00 00 00 00 dba Octave band centre frequency [Hz] Octave band centre frequency [Hz] Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 39 34 27 dba 39 34 27 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard 2. 3. 4. 5. Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. The operation noise measuring method is in accordance with JISC9612. Measuring location: anechoic chamber 3D1000 FFAA Sound pressure level [db] 85 75 65 55 45 35 25 15 NR0 NR5 NR NR15 NR Cooling mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR25 63 125 2 0 00 00 00 00 dba Sound pressure level [db] 85 75 65 55 45 35 25 15 Heating mode NR NR85 NR NR75 NR NR65 NR NR55 NR NR45 NR NR35 NR NR0 NR25 NR5 NR NR15 NR 63 125 2 0 00 00 00 00 dba Octave band centre frequency [Hz] Octave band centre frequency [Hz] Legend dba = A-weighted sound pressure level (A scale according to IEC). A Scale Fan speed B High Cooling Total db Heating Total db C Medium D Low Location of microphone A B C D A B C D dba 43 32 dba 43 32 Notes 1. Operating conditions: power source 2-2 V/2 V / Hz; JIS standard 2. 3. 4. 5. Background noise already taken into account. Operating noise varies depending on operation and ambient conditions. The operation noise measuring method is in accordance with JISC9612. Measuring location: anechoic chamber 3D1001 12 Split - Sky Air FFA-A

9 Air flow patterns 9-1 Air Flow Pattern - Cooling 3 9 Split - Sky Air FFA-A 13

9 Air flow patterns 9-1 Air Flow Pattern - Cooling 9 14 Split - Sky Air FFA-A

9 Air flow patterns 9-1 Air Flow Pattern - Cooling 3 9 Split - Sky Air FFA-A 15

9 Air flow patterns 9-1 Air Flow Pattern - Cooling 9 16 Split - Sky Air FFA-A

9 Air flow patterns 9-2 Air Flow Pattern - Heating 3 9 Split - Sky Air FFA-A 17

9 Air flow patterns 9-2 Air Flow Pattern - Heating 9 18 Split - Sky Air FFA-A

9 Air flow patterns 9-2 Air Flow Pattern - Heating 3 9 Split - Sky Air FFA-A 19

9 Air flow patterns 9-2 Air Flow Pattern - Heating 9 Split - Sky Air FFA-A

Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 0, B- Oostende - Belgium - www.daikin.eu - BE 0412 1 336 - RPR Oostende EEDEN17 05/17 Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU), Fan coil units (FCU) and variable refrigerant flow systems (VRF) Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.