PRODUCT CATALOGUE ROOFTOP BALTIC

Similar documents
Flexy II Product catalogue

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

APPLICATION GUIDE WING

APPLICATION GUIDE. Heat pump Cooling Capacities of 8 a 13 kw FLOOR STANDING

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

APPLICATION GUIDE FLEXY FX. Rooftop packaged unit with heat recovery kw FLEXY FX-AGU-1112-E. lennoxemeia.com

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

... RTU. Packaged Air to Air Heat Pump...

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

50TM COMBINATION HEATING/COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Voyager. 12½ to 25 Ton Light Commercial Packaged Units with ReliaTel Microprocessor Controls

48 50 UH UA PACKAGED ROOFTOP

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Gas fired rooftops. Comfort all year round

Voyager II Rooftop Units

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

50TM TFF COMBINATION HEATING/COOLING UNITS

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Installation Operation Maintenance

48TM GAS HEATING/ELECTRIC COOLING UNITS

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

RGE 13 A T - 1 A

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftop Close control Water source heat pumps Direct expansion

ACTIVA SERIES ROOF TOP Air Conditioners 017/040

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

TECHNICAL SPECIFICATIONS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Submittal Data Performance Data Electrical Data

Voyager III Rooftop Units. Voyager III. Rooftop Units RT-PRC022-E4. Cooling-only. Heat-pump. Gas-fired. Heat pump with gas-fired heating

TECHNICAL SPECIFICATIONS

48/50UA-UH. Packaged Rooftop Cooling Only Units, Heat Pumps and Gas Heating Units

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

air systems Roomtop RTC-RTH 15 to 30 - L

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Neosys Product catalogue

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

13 GEP A L P - 1 A

Technical Manual Binair Monobloc Heat Pump

RT-OA TM Rooftop Outdoor-Air (DOAS)

DCG Commercial. Submittal Data Form

TCD-TCH. Self-contained rooftop unit. VOYAGER I and II range TCD: Downflow discharge and intake TCH: Horizontal discharge and intake

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

Packaged Heat Pumps. Precedent - R-410A Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC013-EN. August 2009

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

3- to 24-Ton Models. Commercial Packaged Rooftop Units. The most energy-efficient rooftop unit in the industry *

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

AHU Plus. DX Air Handling Units

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Installation Operation Maintenance

THE RIGHT SPEC. RIGHT NOW.

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

THE ULTIMATE ROOFTOP SOLUTION

PRODUCT RANGE: ROOFTOP PACKAGE

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Packaged Heat Pumps. Voyager 12½ to 20 Tons 60 Hz PKGP-PRC001-EN. September 2004

PREEVA air handling unit

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

FEATURES AND BENEFITS

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

Fan coil unit KL. Wall unit Ceiling unit

Air conditioners Cooling only

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

COOLflow 4E PRODUCT RANGE

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Digital Precise Air Control - DPAC

VariCool VAV Engineering Guide

Transcription:

PRODUCT CTLOGUE ROOFTOP LTIC

ROOFTOP Cooling only Heat pump Cooling and gas heat Dual fuel " 50 kw C/H/G/D - 20! Compliant with EUROVENT certification program! Compliant with EN 60204-1! Compliant with PED 97-23 directive! lternate defrost : ll heat pump altics with 2 circuits, have independent defrost. When one circuit is in defrost cycle, the second is still in heat pump mode! Dynamic defrost : using a set of sensors, Climatic50 detects when coils are frozen and starts defrost cycle only when needed! luzinc casing (10 years warranty against corrosion)! Stainless steel fixings! luminium condensate drain pan! Easy access to all components! Thermostatic expansion valves! Variable drive pulley as a standard feature! External pressure tap allows easier measurements of HP/LP without opening the rooftop! External static pressure up to 400 Pa (size 20 to 35) and 500 Pa (size 40 to 50)! 93% efficiency gas burner! Fireproof (M0) insulation! Removable condensate drain pan, the bent drain traps are shipped as a kit! Plug and play unit, all units have factory fitted options, fully tested and wired! ll electrical components are protected by circuit breakers! Numbered wires, all wires and connectors are numbered as shown on the electrical drawing to facilitate maintenance and diagnostic! DK units (dual-fuel), combine heat pump heating with gas fired heating CLIMTIC 50 allows the selection of the most efficient way to generate heat based on the oustide temperature! Scroll compressors CLIMTIC 50! 16 bits, 2 megabytes flash memory processor! Can display 50 different faults! 100 settings avalaible for customisation! 100 readings available for diagnostic and monitoring! nti shortcycle, equalisation of compressor running time functionality! Master-slave capability, staggered start feature! utomatic summer/winter time change! 4 dry outputs contacts and 2 dry inputs contacts are availabe as standard 2

GENERL DT LTIC CK/HK/GK/DK 020 025 030 035 Cooling mode CK/GK Gross cooling capacity (35 C ext, 27 C in, 47% HR) Eurovent kw 19,8 24,3 31,2 34,6 Gross cooling capacity (32 C ext, 26 C in, 60% HR) kw 20,9 25,5 32,9 36,5 Gross COP cooling (35 C ext, 27 C in, 47% HR) 2,5 2,2 2,3 2,1 Gross COP cooling (32 C ext, 26 C in, 60% HR) 2,7 2,5 2,5 2,4 Power input CK kw 8 10,9 13,6 16,1 Heating mode CK Net heating capacity (7 C ext, 20 C in) kw 18,3 23,3 30,2 33,4 Net COP heating (7 C ext, 20 C in) 2,7 2,6 2,6 2,6 uxiliary heating Gas heat capacity kw - S/H (1) 18,6/30,7 18,6/30,7 18,2/42,8 18,2/42,8 Electric heater capacity kw - S/M/H (1) 12/24/36 12/24/36 24/36/48 24/36/48 Hot water coil capacity (20 C in / water 90-70 C) kw - S/H (1) 23,6/38,5 26,6/38,5 34,2/49,0 37,1/53,5 Refrigeration circuit Number of compressors / Number of circuits nb 1/1 1/1 2/2 2/2 Scroll compressor type type ZR81 ZR11 ZR72 ZR81 Refrigerant charge per circuit kg 3 3 4 4 Maximum Outdoor temperature at Indoor 27 C D/ 19 C W C 45 43 44 42 Ventilation Nominal airflow at 100 Pa m 3 /h 3600 4500 5400 6300 Minimum airflow m 3 /h 2900 3600 4300 5000 Maximum airflow m 3 /h 4300 5400 6500 7600 coustic Outdoor sound pressure at 10 meters d() 50 51 49 50 Indoor sound power (supply) d() 75 80 76 79 LTIC CK/HK/GK/DK 040 045 050 Cooling mode CK/GK Gross cooling capacity (35 C out, 27 C in, 47% HR) Eurovent kw 40,2 44,2 47,7 Gross cooling capacity (32 C out, 26 C in, 60% HR) kw 42,5 46,6 50,3 Gross COP cooling (35 C out, 27 C in, 47% HR) 2,4 2,3 2,2 Gross COP cooling (32 C out, 26 C in, 60% HR) 2,7 2,5 2,4 Power input CK kw 16,7 19,2 22,1 Heating mode CK Net heating capacity (7 C out, 20 C in) kw 38,8 42,7 47,3 Net COP heating (7 C out, 20 C in) 2,7 2,6 2,6 uxiliary heating Gas heat capacity kw - S/H (1) 30,7/55,8 30,7/55,8 30,7/55,8 Electric heater capacity kw - S/M/H (1) 27/45/54 27/45/54 27/45/54 Hot water coil capacity (20 C in / water 90-70 C) kw - S/H (1) 46,8/66,5 49,8/71,2 52,6/75,5 Refrigeration circuit Number of compressors / Number of circuits nb 2/2 2/2 2/2 Scroll compressor type type ZR90 ZR90+ZR11 ZR11 Refrigerant charge per circuit kg 5,5 5,5 5,7 Maximum Outdoor temperature at Indoor 27 C D/ 19 C W C 45 43 42 Ventilation Nominal airflow at 100 Pa m 3 /h 7200 8100 9000 Minimum airflow m 3 /h 5800 6500 7200 Maximum airflow m 3 /h 8600 9700 10800 coustic Outdoor sound pressure at 10 meters d() 50 50 51 Indoor sound power (supply) d() 76 78 80 (1) : S = Standard heat - M = Medium heat - H = High heat 3

LTIC PHYSICL DT OX C OX C C D D D OX C D LTIC CK/HK/GK/DK 020 025 030 035 040 045 050 View OX OX C OX C OX D OX D OX D OX mm 2050 2050 1950 1950 1950 1950 1950 mm 1418 1418 1913 1913 2233 2233 2233 C mm 1220 1220 1220 1220 1220 1220 1220 D mm 478 478 418 418 418 418 418 Weight of standard units without hood kg 377 428 501 503 626 630 638 with hood kg 400 451 529 531 659 663 671 Weight of gas units Standard heat without hood kg 419 472 567 572 709 718 723 Standard heat with hood kg 442 495 595 600 742 751 756 High heat without hood kg 431 484 586 591 730 739 744 High heat with hood kg 454 507 614 619 763 772 777 4

ROOFCUR LTIC PRINCIPLE SKETCH MULTIDIRECTIONL ROOFCUR PRINCIPLE SKETCH 2 2 1 1 3 3 4 Fresh air Return air Exhaust air Supply air 1 Supply fan 2 Economiser damper 3 Exhaust damper or Exhaust damper + exhaust air Fresh air Return air Exhaust air Supply air 1 Supply fan 2 Economiser damper 3 Exhaust damper or Exhaust damper + exhaust air 4 Multidirectional roofcurb NON DJUSTLE, NON SSEMLED ROOFCUR DJUSTLE ROOFCUR MULTIDIRECTIONL ROOFCUR ROOF OPENING / EXTERNL DIMENSION LTIC CK/HK/GK/DK 020 025 030 035 040 045 050 Non-adjustable, non assembled roofcurb mm 1083 1083 1280 1280 1530 1530 1530 mm 1783 1783 1640 1640 1640 1640 1640 mm 1083 1083 1280 1280 1530 1530 1530 mm 1783 1783 1640 1640 1640 1640 1640 ssembled adjustable roofcurb mm 1085 1085 1282 1282 1532 1532 1532 mm 1795 1795 1642 1642 1642 1642 1642 mm 1085 1085 1282 1282 1532 1532 1532 mm 1795 1795 1642 1642 1642 1642 1642 Multidirectional roofcurb (External dimensions. No roof opening required ) CK HK GK DK CK HK GK DK CK HK GK DK mm 1236 1236 1433 1433 1683 1683 1683 mm 2182 2182 2035 2035 2105 2105 2105 mm 1236 1236 1433 1433 1683 1683 1683 mm 2182 2182 2035 2035 2105 2105 2105 5

LTIC OPTIONS! Non adjustable, non assembled roofcurb Shipped folded flat for ease of shipping and handling, it is easily field assembled.! djustable Roofcurb luzinc construction. For this adjustable roofcurb that can be installed on a roof with up to 4 to 5% slope in all directions.! Multidirectional flow roofcurb Enable many airflow possibilities, including horizontal supply and return on the same side.! ir Sock Control Soft start control allows the air socks to be progressively filled with air on start up.! Economiser "Free cooling" is provided through the use of fresh air when appropriate rather than cooling the return air includes fresh and return air damper and hood.! Gravity exhaust damper Gravity exhaust damper relieves the pressure when outside air is being introduced in the system.! Power Exhaust Fan Installed with economiser assembly, it provides exhaust air pressure relief when high levels of outside air are being introduced in the system.! DC 50 : Comfort Display This is a remote controller for non-technical customer. It was designed to aesthetically fit in the room and be very easy to use. With DC50, the customer can change the scheduling of the different time zones, modify temperature set points and percentage of fresh air in each zone.! DS 50 : Service Display This new service display controller is a plug and play feature. This allows service personel to set, up to 100 settings, read up to 100 variables, up to 50 faults and read the history of the last 16 faults.! nalogic «lower-on» sensor and dirty filter indication differential pressure sensor measures the pressure drop across the evaporator coil and filters. It indicates if the filters are dirty, missing or if there is no airflow.! Panel filters with metal frames and disposable filter media (EU4 / G4) Metallic frame with washable filter media (rated EU4/G4) available.! Indoor ir Quality Sensor This feature gives the possibility to match minimum fresh air requirements with occupancy. It measures CO2 levels and adjusts fresh air flow rate accordingly.! Electric Heater 3 sizes : "Standard", "Medium", and "High" heat. "Standard" and "Medium" heat are 2 stages electric heaters, "High" heat is fully modulated with TRIC control allowing a constant supply temperature.! Hot Water Coil 2 and 3 row hot water coils configurations are available and offer fully modulated control through the use of a 3 way valve.! 93% high efficiency Gas urner Option Lennox is proud to introduce the first high efficiency gas burner available on rooftop in Europe with 93% efficiency.! Customised color Units can be supplied in various colours to suit any application or requirement.! nti-corrosion Protection Where the units are installed in potentially aggressive environments. Coils can be treated with "blygold" coating. 6

! Fire-Stat This thermostat provides a signal when the temperature of the airstream is above an adjustable set point.! Disconnect Switch lockable main disconnect switch is available to increase safety around the rooftop unit.! Smoke Detector The ionic head of the smoke detector can detect any type of smoke. When this occurs the unit will stop operating, the return air damper will close fully and the fresh air damper will open fully.! CLIMLINK2 / CLIMLOOK2 Smart and very competitive monitoring system, it allows the supervision of up to 12 rooftops equiped with Climatic50 either on site, or remotelly through the use of a phone line and Internet explorer. Most of the settings/variables/faults/schedules are accessible with Climalink/Climalook2.! CLIMLOOK3 Climalook3 has the same functionality as Climalook2 but can also supervise up to 8 rooftops equipped with Climatic2 and 12 rooftops equipped with Climatic50. MIN FORM SCHEDULE SHEET 7

GERMNY : ELGIUM : SPIN : FRNCE : UNITED KINGDOM : MIDDLE-EST : NETHERLNDS : POLND : PORTUGL : CZECH REPULIC : RUSSI : SLOVKI : UKRINE : LENNOX DEUTSCHLND GmbH Tel : + 49 69 42 09 79 0 Fax : + 49 69 42 09 79 40 e-mail : info.de@lennoxdeutchland.com LENNOX ENELUX N.V./S.. Tel : + 32 3 633 30 45 Fax : + 32 3 633 00 89 e-mail : info.be@lennoxbenelux.com LENNOX REFC S.. Tel : + 34 915 40 18 10 Fax : + 34 915 42 84 04 e-mail : marketing@lennox-refac.com LENNOX FRNCE Tel : + 33 1 64 76 23 23 Fax : + 33 1 64 76 35 75 e-mail : marketing.france@lennoxfrance.com LENNOX INDUSTRIES LTD Tel : + 44 1604 599400 Fax : + 44 1604 594200 e-mail : ukmarketing@lennoxind.com LENNOX DISTRIUTION Tel : + 971 4 262 9309 Fax : + 971 4 266 7082 E-fax : +1 240 368 73 62 e-mail : mmrifai@emirates.net.ae LENNOX ENELUX.V. Tel : + 31 33 2471 800 Fax : + 31 33 2459 220 e-mail : info@lennoxbenelux.com LENNOX POLSK Sp. z o. o. Tel : + 48 22 832 26 61 fax : + 48 22 832 26 62 e-mail : info@lennoxpolska.pl LENNOX PORTUGL Tel : + 351 22 998 33 70 Fax : + 351 22 998 33 79 e-mail : info@lennoxportugal.com LENNOX JNK Tel : + 420 2 510 88 111 Fax : + 420 2 579 10 393 e-mail : janka@janka.cz LENNOX DISTRIUTION MOSCOW Tel : + 7 095 246 07 46 Fax : + 7 502 933 29 55 e-mail : lennox.dist.moscow@mtu-net.ru LENNOX SLOVENSKO Tel : + 421 7 44 87 19 27 Fax : + 421 7 44 88 64 72 e-mail : lennox.slovensko@lennox.sk LENNOX DISTRIUTION KIEV Tel : + 380 44 213 14 21 Fax : + 380 44 213 14 21 e-mail : jankauk@uct.kiev.ua OTHER EUROPEN COUNTRIES, FRIC : PC-RT-0403-E LENNOX DISTRIUTION Tel : + 33 4 72 23 20 14 Fax : + 33 4 72 23 20 28 e-mail : marketing@lennoxdist.com www.lennoxeurope.com