INSTALLATION INSTRUCTIONS FOR ENTRANCE CONTROL SYSTEM MODEL GL-RO-3

Similar documents
MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

SPECIAL SPECIFICATION 1646 Digital Loop Vehicle Detector Unit

TEXAS DEPARTMENT OF TRANSPORTATION DEPARTMENTAL SPECIFICATION TO-6043 DIGITAL LOOP VEHICLE DETECTOR UNIT

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

D-TEK -MS Vehicle Loop Detector. Operating Instructions

ENGINEERED PARKING SYSTEMS MODEL 3416D

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

SSV-DC user manual. Phason

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

RATIO:GUARD Model E-1S EC Monitor

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

Installation, Operating and Maintenance Manual

Operating Instructions

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Static Pressure Control

For more information, please visit or call toll free at

Model 17A00 Expansion Enclosure

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Power Supply Display Module PSDM. Installation and Operation Manual

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

AL600ULX Series. Power Supply/Charger. Installation Guide

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

DIGITAL LIGHT CONTROLLER

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Greentrol Automation, Inc.

Warranty Info: ETI s warranty policy can be viewed at:

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Gate Operator. Modfications

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Heatrix Electric Duct Heater HXOB Installation Instructions

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

ET10 Series Stand-alone LCD Fan Coil Thermostat

ARM SERIES Switching Relays With Priority

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

M770 ph Controller Owner s Manual

PSN-1000 & PSN 1000(E) Installation Manual

Operating Instructions

Across-the-Line SERIES MP300 Combined Manual and Automatic

TECHNICAL DATA OBSOLETE

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Installation Guide for models:

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

TRX MAINS CONNECTION DIAGRAM

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

TROUBLESHOOTING VANGUARD

RELEASE DEVICE CONTROLS

Owner s Manual RD432-0 Chemical Controller

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

flexibility programmed settings.

WCAD-Series Vended Washers Troubleshooting And Fault Codes

Ozone Generator and Ozone PCB Tests and Fault Troubleshooting

Liquid Helium Level Instruments

Series. Access Power Controllers. Installation Guide

DIGIHEAT IN LINE HEATERS

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

DSP-13 Tri-Axis Detection (TRIAD TM ) System

End To End Optical Beam Smoke Detector. Additional Information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

User manual and installation guide

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

03.03.mmm REV.2 09/01

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Operating Instructions

1020 Industrial Drive, Orlinda, TN fax

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Soft Start Series MP700 Solid State, Reduced Voltage

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Operating Instructions. For. Alarm Control Module. Model SSR 500

CII FCAC-150 Series Relay

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

CAUTION & SYMBOL DEFINITIONS:

ST E /ST E / ST E / ST E ST E / ST E / ST E

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Instruction Manual Model L2 RF Switch

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Isco 3700ZR Sampler. Manual Set

50A Integrated Furnace Control

FireNET Plus Wiring Instructions

MTRA-FSP Level Control Relay. Installation & Operation Manual

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Transcription:

INSTALLATION INSTRUCTIONS FOR ENTRANCE CONTROL SYSTEM MODEL GL-RO-3 DATE ISSUED 7/2008 GOODLIN SYSTEMS INC. www.goodlinsys.com

CONTENTS INTRODUCTION Pg 2 SPECIFICATIONS Pg 2 DETECTION FIELD THEORY Pg 3 INSTALLMENT PROCEEDURES Pg 4 BOARD LAYOUT Pg 5 NEEDED WIRING Pg 5 SAMPLE WIRING (OPTIONS) Pg 6-7 COMMON PROBLEMS & SOLUTIONS Pg 8

INTRODUCTION The inductive loop control box (GL- RO-3) is a control box that works on the principle of metal detection. This is accomplished with the GL-RO-3 in conjunction with a coil of wires referred to as a loop or sensor. The GL-RO-3 will work with almost any style loop. When metal enters the electrical field generated by the loop, the detector (supplies the power to the loop to generate the field) is activated to show a presence condition. This is when the relay is activated in order to turn on any number of controls or equipment. Although the GL-RO-3 can work with many types of loops, Goodlin Systems recommends using only loops manufactured by Goodlin Systems. Our loops have been specifically designed for use with our controls, and for the most accurate measurement of vehicles. This makes the use of floor cut loops inadequate for most car wash applications. POWER INPUT: 110 VAC 60Hz SPECIFICATIONS POWER OUTPUT: 24 VAC 60Hz.25 AMPS (FOR LIGHT CIRCUIT ON GL-14) RESPONSE TIME: 200-100 milliseconds ENCLOSURE: Size 8 W x 10 H x 6 D Type UL environmental 1,4,12, and 13 non-metallic PRESENCE MODE: Activation upon presence of metal 15 minute hold time OUTPUT PRESENCE RELAY: SKNP 10 Amp 24vdc coil DETECTOR PRESENCE RELAY: SPST 3 Amp (Can be converted to second presence relay) FREQUENCY: Three selectable frequencies. Range 25-100 kilohertz LOOP PROTECTION: Isolation transformer allows operation with poor quality loops, including a single point, short to ground. Lightning protection: The detector can withstand a 10 microfarad capacitor charged to 1,000 volts to be discharged directly into the loop terminals, 2,000 volts with an earth ground. ALL COMPONENTS ARE UL APPROVED PAGE 2

DETECTION FIELD THEORY The detection field is like an invisible set of bubbles or lines crossing from one side of the sensor* to the other. When power is first applied, the detector remembers the way the bubble is formed. The field will only be altered or reshaped y the presence of new metal. The detector will remember and accept this new shape if it is reset; thus the sensor can be placed by metal as long as the metal stays where the detector remembers it was. Any new metal entering the field will reshape the field. It is this reshaping, or changes, that the detector will see and activate on. Also note that the closer the metal is to the sensor, the less it has to move to reshape the field. The amount of metal also has an effect on the amount of change in the field. The more metal the more change. When the metal is removed from the field the bubble returns to the original state the detector remembers, thus the detector deactivates. IF THE FIELD DOES NOT RETURN TO ITS ORIGINAL SHAPE THE DETECTOR DOES NOT DEACTIVATE. AN UNSTABLE LOOP CAUSES THIS. Thus is seen by the detector turning on then off frequently without metal entering the fields. Most detectors have an internal check that phases out any detection/activation in a preset amount of time. If a car was to set over a loop for more than 30 minutes, the detector would automatically reset the field and by ready for any new metal. There is a model available that will not automatically reset itself. This model is a permanent presence detector. This model is available with any of our systems at no extra cost. MOST INSTABILITY PROBLEMS ARE CAUSED BY THE MOVEMENT IN THE FIELD BY CLOSE, LARGE METAL PIECES. THE MOST CONCENTRATED PART OF THE FIELD IS ABOUT 4-6 INCHES FROM THE SURFACE OF THE SENSOR*. * SENSOR IS THE LOOP OR COIL WINDINGS THAT SET UP THE FIELD PAGE 3

INSTALLMENT PROCEDURES 1.) PICK OUT A GOOD TIME FOR INSTALLATION! An evening that has a relatively slow next day is preferred in case of trouble or complications. 2.) TEST THE CARWASH FOR PROPER WORKING ORDER! MAKE SURE THE EQUIPMENT WORKS BEFORE WORKING ON IT! This way if something is wrong after you start you can tell it s the equipment and not the installation of the new system. This is true for any application. 3.) Find a suitable place for the control box. If a GL-14 or GL-SM8-B is used make sure the sensor cord can reach between the sensor and the control box. Mount box according to local codes. 4.) Pipe and Wire in according to your local codes. Consult the Needed Wiring diagram for the circuits needed. 5.) Make sure you have a constant 110vac power for this system. It is recommended that this be a constant circuit, and NOT INTERLOCKED. It is recommended that power to and on the control box is kept on at all times. The heat generated by the transformer will keep the control box free of condensation. It is highly recommended to not have any piping run into the top of the control box. This prevents water from running down the pipe to the control box. 6.) Wire in the Inductive Loop Sensor. (GL-14, GL-SM8-B, etc.) 7.) Power up and test detection and function with a steel box/plate Examples to use are License Plate, Snow Shovel, Tool Box, etc. 8.) After installation, test the car wash for proper operation. NOTE: For Detector information please read the Detector Instructions. Detectors are factory preset for normal operation. PAGE 4

C:\General Cadd 4\Gxd\GL-R0\GLRO3-M1.gxd -- 06/14/2012 -- Scale 1 : 3.000

COMMON PROBLEMS AND SOLUTIONS 1.) THERE IS NO POWER TO BOARD. A.) MAKE SURE POWER SWITCH IS PUT TO THE ON POSITION. B.) NO 110VAC POWER OR NUETRAL TO THE BOARD. TEST INCOMING POWER C.) BLOWN FUSE: CHECK WIRING AND REPLACE FUSE 2.) NO POWER TO RELAY, POWER LIGHT ON BOARD, DETECTOR IS WORKING A.) BLOWN FUSE: CHECK WIRING AND REPLACE FUSE B.) TRANSFORMER LEG BROKEN DURING SHIPPING. REMOVE BOARD AND PULL ON TRANSFORMER WHILE LOOKING AT LEGS. SOLDER LEG FROM THE TOP OF THE BOARD. IF UNABLE TO FIX CALL GOODLIN SYSTEMS INC. 3.) NOT ENOUGH SENSITIVITY, SKIPPING OR NOT PICKING UP TRUCKS A.) IMPROPER DETECTOR SETTING: READJUST THE DETECTOR. B.) LARGE METAL PRESENT TO CLOSE TO SENSOR. RELOCATE THE SENSOR OR METAL. 4.) DETECTORS PRESENCE LIGHT IS FLASHING RAPIDLY A.) THE DETECTOR DOES NOT SEE THE SENSOR OR LOOP. B.) WIRING INTO CONTROL BOX WRONG C.) BAD SPLICE D.) LOOP OR SENSOR NOT WIRED IN AT ALL E.) CABLE FROM LOOP OR SENSOR IS DAMAGED 1.) DETECTOR IS STAYING ON AFTER CAR LEAVES LOOP OR SENSOR A.) LOOP IS UNSTABLE: TRY TO ADJUST DETECTOR. CHECK FOR MOVING METAL. B.) BAD DETECTOR. CALL GOODLIN SYSTEMS INC. C.) METAL TOO CLOSE TO LOOP. PAGE 8