REFRIGERATED ROOM & TEMPERATURE/HUMIDITY CONTROLLERS

Similar documents
Electronic Controller For Refrigeration XLR130 XLR170

XH260L XH260V. Dixell Operating instructions TEMPERATURE AND HUMIDITY CONTROLLER 1. GENERAL WARNING

dixel Installing and Operating Instructions PRELIMINAY

Digital Controller XR70CX. Operating Manual. 5/10 Rev. B


Dixell Installing and Operating Instructions release 7.0

XR77CX. dixel Installing and Operating Instructions Digital controller for medium-low temperature refrigeration applications

XW70L. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3.

XH340L-V TEMPERATURE AND HUMIDITY CONTROLLER FOR SEASONING-MATURING CABINETS 1. GENERAL WARNING

Commercial Freezer Service Manual

Time KEY COMBINATIONS: + To lock & unlock the keyboard. + To enter in programming mode. + To return to the room temperature display. 4.

XW40K AND T620T - T620 V620 CX620

dixel Installing and Operating Instructions

Rev 0 09-FEB XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

XR60C ,QVWDOOLQJDQG2SHUDWLQJ,QVWUXFWLRQV. Digital controller with defrost and fans management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

Commercial Refrigerator Service Manual

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

XWA11V. Walk-In Temp / Door /Alarm / Light Module

UNIVERSAL R V3.0. NEW FEATURES on the V3.0

Rev 1 24-MAY XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

XW90LT. Digital controller for medium-low temperature refrigeration applications AUX 1. GENERAL WARNING 2. GENERAL DESCRIPTION 3.

XB570L XB570L. dixel Operating and Instructions Manual BLAST CHILLER - QUICK CHILL AND HOLD FUNCTION

XR60CX. Installation and Operating Instructions. Digital controller with defrost and fans management. + + To return to the room temperature display.

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

User Instructions Lab* Frost. Ultra Low Temperature Freezers Model LAB

OPERATING INSTRUCTIONS ULTF 80 / 220 / 320 / 420

XH50P - XH55P Temperature/relative humidity probe with RS485 serial line

QC 11 & QC 600 Blast Chiller & BQCF 40 Chill / Freeze Bakery Cabinet

Top Mount Full Length Swinging Doors

FX-1 2N1 TWO COOLING SYSTEMS IN ONE Refrigerator (40 F) Freezer (-5 F) Or anywhere in between (-5 to 40 F)

CIAO series ICE CREAM DISPLAY CABINET. Maintenance And Use Manual

Refrigerated Milk Drawer

Refrigerated Cabinets Square Format

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

User Manual Ichill 200 L/D (Firmware version 1.7)

Inline GN Series Refrigerated Well

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

XB590L BLAST CHILLER

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES KNA4C9DP47L-1

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

EVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815

Food & Beverage Cabinet

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. 1 ON Fan1 enabled (only for XC30CX) 2 ON Fans enabled (only for XC30CX) kpa. Time

AIR COOLED CHILLERS MODELS: MPCA0005 MPCA0150 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Refrigerated Cabinets Curved Format

XC10CX and XC30CX. Digital controller for CDU management 1. GENERAL WARNING 4. FRONT PANEL COMMANDS 2. GENERAL DESCRIPTION

Refrigerated Cabinets

Refrigerated Cabinets Curved Format

Open Front Food & Drinks Cabinet AS/NZS

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

Refrigerated air dryers

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

Bottle cooler controllers Solutions for static, ventilated and open coolers

REVERSO. Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4-6 Spare parts page 7

EVF818 Installer manual ver. 1.0 Code 144F818E104 EVF818. Split execution controller for temperaturecontrolled

MINITOP Refrigerated Self-Service Display underneath

OMNITOP Refrigerated Display with Ventilated Cooling

IKEA USA Refrigerated Cabinets

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Installation & Operation Manual. LEGACY Self-Contained Spot Merchandiser. Stratus Multi Deck Installation and Operations. Manual

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner SLIMKOOL SERIES K_NA4C4SP28L

RTC-M_A series FTC-M_A series

HRE-MA series HFE-MA series HRFE-MA series

XC1008D -XC1011D- XC1015D and VGC810

XLH210: controller for gas leak detectors

User & Installation Manual

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

IC200L Series User manual

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Sf2+HF2 Sf2 Sf1 + Hf1 Sf1. DLT Prb. Ground

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTREPID SERIES K2A6C30EP56TR-4

Electronic Controls Handbook Programming Flow Charts & Parameter Lists for

QUICK REFERENCE GUIDE SERIES IC100CX FW 1.8 (rel. 1.0)

JDDT1 - Single Stage Digital Thermostat

ENERGY 200 Electronic Control for mono & bi- Compressor CHILLERS. User Manual

MODEL URS-1: FACTORY RETROFIT PROGRAM

INSTALLATION & USER MANUAL

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner. GUARDIAN SERIES K3NA4C3DP24L 480 Volt 1-PHASE

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner TRIMLINE KA6C4NP28L

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

User Instructions Ultra Low Temperature Freezers Model LAB/ULT

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner 480 VOLT GUARDIAN SERIES K3NA6C18DP53L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner 480 VOLT GUARDIAN SERIES K3NA6C26DP60L

Thermometers and temperature controllers

Power s Sliding Glass 2 Door Floral Coolers For Bush Refrigeration

REMOTE CONTROL FOR CHILLER MYCHILLER

SMG8B & SSG8B. Installation & Operation Manual. IMPORTANT Keep in store for future reference! Medium Temperature Self Contained

Temperature - Humidity - Pressure

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L

IPC108D - IPC108E (V.2.0)

CTT8 TEMPERATURE MONITOR DEVICE

EWHT800LX. Controllers for cold rooms and curing rooms for on-board installation

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Transcription:

SECTION INDEX FUNCTIONS MODELS XLR100 COOL MATE - NT, MT AND LT APPLICATIONS - SERIAL OUTPUT Advanced multifunction controllers for NT refrigerated rooms XLR130 Advanced multifunction controllers for MT - LT refrigerated rooms XLR170 XLR100 series parameters XLR400 COOL MATE - NT, MT AND LT APPLICATIONS - DUAL TEMPERATURE MANAGEMENT - SERIAL OUTPUT Advanced multifunction controllers with dual temperature management for NT and MT - LT refrigerated rooms XLR460 Advanced multifunction controllers with dual temperature management for MT - LT and MT - LT refrigerated rooms XLR470 XLR400 series parameters XLR700 COOL MATE - NT, MT AND LT APPLICATIONS - HACCP REQUIREMENTS - SERIAL OUTPUT Advanced multifunction controllers for NT refrigerated rooms with HACCP requirements XLR730 Advanced multifunction controllers for MT - LT refrigerated rooms with HACCP requirements XLR770 XLR700 series parameters XLH200 COOL MATE - NT, MT AND LT APPLICATIONS - TEMPERATURE/HUMIDITY MANAGEMENT - SERIAL OUTPUT Advanced multifunction controllers for TN - MT - LT refrigerated rooms with temperature and humidity management XLH260 XLH200 series parameters XLH300 COOL MATE - MATURING ROOM APPLICATIONS - SERIAL OUTPUT Advanced multifunction controllers for TN maturing rooms with temperature and humidity management XLH360 Advanced multifunction controllers for TN - MT - LT maturing rooms with temperature and humidity management XLH380 XLH300 series parameters XW200/500 + V-KIT - MT AND LT APPLICATIONS - SPLIT FORMAT - SERIAL OUTPUT Advanced multifunction controllers with vertical format keyboard and wall mounting box for MT - LT refrigerated rooms XW200/500 + V-KIT 60 61 61 62 63 64 64 65 66 68 68 69 70 72 73 70 72 72 73 74 74 59

PANEL MOUNTING WALL MOUNTING 230x210mm XLR100 COOL MATE SERIES: CONTROLLERS FOR NT, MT AND LT APPLICATIONS Advanced multifunction refrigeration controllers suitable for both heating and cooling applications Temperature control can be performed on probe 1, probe 2 or by the difference between probe 1 and 2 Complete comsor and defrost management Maximum and minimum temperature recording Direct line power supply 230 (110)Vac. No external transformer required Instant visibility of machine status via display icons Clear alarm signals thanks to the front lid Fast and easy wiring Designed to be wall or panel mounted Standard communication protocol ModBUS-RTU Hot key or Prog tool kit connector for a quick and easy programming 10VA max power absorption Display with red LED (30,5mm high) and 11 icons HOW TO ORDER XLR100 X L R 1 - A B C D E A B C D E Power supply Inputs RTC Measurement unit Built in RS485 1 = 24Vac 4 = 110Vac 5 = 230Vac 8 = 110 230Vac N = P = PTC 1 = No 3 = Yes C = C F = F 2 = No 3 = Yes 60

XLR100 COOL MATE ADVANCED MULTIFUNCTION CONTROLLERS for NORMAL, MEDIUM and LOW TEMPERATURE COLD ROOMS XLR130 off cycle defrost digital controller for N.T. XLR170 Digital controller for M.T. - L.T. ventilated applications 230x210mm FEATURES Display: n digits Keyboard: push buttons Power supply Probe inputs Thermostat Display Digital inputs Alarm, block alarm, sure switch, start defrost, energy saving, ON/OFF, AUX, holiday Door switch Relay outputs Comsor Fans Light AUX Alarm Other Hot Key/Prog Tool Kit output Serial output Buzzer Real time clock XLR130 8 24, 110, 230Vac /PTC /PTC opt XLR170 8 24, 110, 230Vac /PTC /PTC /PTC opt XLR130 XLR170 61

PARAMETERS REGULATION Set point Differential Minimum set point Maximum set point Outputs activation delay at start up Comsor uration Anti-short cycle delay Time delay between starting comsors 1 and 2 Comsor ON time during fast freezing Comsor ON time with faulty probe Comsor OFF time with faulty probe Kind of action (cooling /heating) DISPLAY Temperature measurement unit Resolution (integer/decimal point) Local display uration DEFROST type mode Set point for smart defrost termination temperature (1 st ev.) termination temperature (2 nd ev.) Interval between defrost cycles (Maximum) length for defrost (1 st ev.) (Maximum) length for defrost (2 nd ev.) Displaying during defrost Max display delay after defrost Start defrost delay Draining time First defrost after startup delay after fast freezing termination probe for first evaporator termination probe for second evaporator FANS Fans operating mode Fans delay after defrost Fans stop temperature Fan probe selection ALARMS Temperature alarms uration Maximum temperature alarm Minimum temperature alarm Temperature alarm differential Temperature alarm delay Delay of temperature alarm at start up Alarm delay at the end of defrost Delay of temp. alarm after closing the door Open door alarm delay Restart temperature regulation after door open alarm Alarm relay silencing Pressure switch activation number ANALOG INPUTS Thermostat probe calibration Evaporator probe calibration Auxiliary probe calibration Evaporator probe ence Auxiliary probe ence Regulation probe selection Temp. increasing during energy saving cycle DIGITAL INPUT Open door control Door switch polarity Configurable digital input polarity Digital input uration Digital input alarm delay Auxiliary relay uration Type of action for auxiliary relay Set Point for auxiliary relay Probe selection for auxiliary relay Alarm relay polarity TIME AND WEEKLY HOLIDAYS Current hour Current minute Current day First weekly holiday Second weekly holiday Third weekly holiday ENERGY SAVING TIMES Energy Saving cycle start time during workdays Energy Saving cycle duration during workdays Energy Saving cycle start time on holidays Energy Saving cycle duration on holidays Temperature increase during the Energy Saving cycle DEFROST TIMES start on workdays start on holidays OTHER Serial address Kind of probe selection Map code Software release First probe display Second probe display Third probe display CODE Set Hy LS US OdS CC0 AC AC1 CCt Con COF CH CF res Lod tdf EdF SdF dte dts IdF MdF MdS dfd dad dsd Fdt dpo daf dfp dsp Fnc Fnd FSt FAP ALC ALU ALL AFH ALd dao EdA dot doa rrd tba nps Ot OE O3 P2P P3P Pbr HES OdC i1p i2p i2f did oa1 ACH SAA ArP oap Hur Min day Hd1 Hd2 Hd3 ILE dle ISE dse HES Ld1- Ld8 Sd1- Sd8 Adr Pbc Ptb rel dp1 dp2 dp3 XLR130 XLR170 62 Present Present and password protected

PANEL MOUNTING WALL MOUNTING 230x210mm XLR400 COOL MATE SERIES: CONTROLLERS FOR NT, MT AND LT APPLICATIONS, DUAL TEMPERATURE MANAGEMENT Advanced multifunction refrigeration controllers with dual temperature management Ideal for heating-cooling applications such as a heated bain-marie counter with refrigerated under-counter storage Designed for a dual refrigeration circuit or 2 independent circuits Integrated defrost management Cooling or heating action selectable by user Direct line power supply 230 (110)Vac. No external transformer required Instant visibility of machine status via display icons Clear alarm signals thanks to the front lid Designed to be wall or panel mounted Standard communication protocol ModBUS-RTU Hot key or Prog tool kit connector for a quick and easy programming 10VA max power absorption Dual display with red LED (25,3mm high) and yellow LED (20,3mm high) and 13 icons TYPICAL APPLICATIONS 1 circuit - 2 evaporators 2 indipendent circuits Heating and cooling application 2 heating applications HOW TO ORDER XLR400 X L R 4 - A 0 C D E A C D E Power supply RTC Measurement unit Built in RS485 1 = 24Vac 4 = 110Vac 5 = 230Vac 8 = 110 230Vac 0 = No 1 = Yes C = C F = F 0 = No 1 = Yes 63

XLR400 COOL MATE ADVANCED MULTIFUNCTION CONTROLLERS with DUAL TEMP. MANAGEMENT for N., M. and L. TEMP COLD ROOMS XLR460 Digital controller for cold rooms with dual temperature management (N.T. + L.T.) 230x210mm XLR470 Digital controller for cold rooms with dual temperature management (L.T. + L.T.) FEATURES First display: n digits Second display: n digits Keyboard: push buttons Power supply Probe inputs Thermostat Thermostat 2 2 Digital inputs Alarm, block alarm, sure switch, start defrost, energy saving, ON/OFF, AUX, holiday Door switch Relay outputs Comsor Comsor 2 2 Fans Fans 2 Light Alarm Other Hot Key/Prog Tool Kit output Serial output Buzzer Real time clock XLR460 ± 4 d.p. 8 24, 110, 230Vac opt XLR470 ± 4 d.p. 8 24, 110, 230Vac 5A 5A 5A opt XLR460 XLR470 64

PARAMETERS REGULATION Probe 1 set point Probe 2 set point Probe 1 differential Probe 2 differential Minimum set point 1 Maximum set point 1 Minimum set point 2 Maximum set point 2 Outputs activation delay at start up (output 1) Outputs activation delay at start up (output 2) Anti-short cycle delay (output 1) Anti-short cycle delay (output 2) Comsor ON time with faulty probe 1 Comsor OFF time with faulty probe 1 Comsor ON time with faulty probe 2 Comsor OFF time with faulty probe 2 Probe 1 regulation mode Probe 2 regulation mode DISPLAY Temperature measurement unit Resolution (integer/decimal point) ALARMS Probe 1 alarm uration Probe 1 minimum temperature alarm Probe 1 maximum temperature alarm Probe 1 temperature alarm differential Probe 1 temperature alarm delay Delay of probe 1 temperature alarm at start up Probe 2 alarm uration Probe 2 minimum temperature alarm Probe 2 maximum temperature alarm Probe 2 temperature alarm differential Probe 2 temperature alarm delay Delay of probe 2 temperature alarm at start up ANALOGUE INPUTS Thermostat probe calibration Evaporator probe calibration Thermostat 2 probe calibration Evaporator 2 probe calibration Evaporator probe ence Evaporator 2 probe ence DIGITAL INPUTS Open door control Door switch input polarity Configurable digital input polarity Digital input alarm delay TIME AND WEEKLY HOLIDAYS Current hour Current minute Current day of the week Current day Month Year First weekly holiday Second weekly holiday Third weekly holiday ENERGY SAVING TIMES Energy Saving cycle start time during workdays Energy Saving cycle duration during workdays Energy Saving cycle start time on holidays Energy Saving cycle duration on holidays Temperature increase during the Energy Saving cycle DEFROST TIMES start time on workdays start time on holidays OTHER Serial address Map code Software release First probe readout Second probe readout Third probe readout Fourth probe readout CODE Set1 Set2 Hy Hy2 LS US LS2 US2 OdS Od2 AC AC2 Con COF Cn2 CF2 CH CH2 CF res ALc ALL ALu ALH ALd dao A2c AL2 Au2 AH2 Ad2 da2 of1 of2 of3 of4 P2P P3P OdC i1p i2p did Hur Min UdA day MOn YEA Hd1 Hd2 Hd3 ILE dle ISE dse HES Ld1-Ld8 Sd1-Sd8 Adr Ptb rel dp1 dp2 dp3 dp4 XLR460 XLR470 Present Present and password protected 65

PANEL MOUNTING WALL MOUNTING 230x210mm XLR700 COOL MATE SERIES: CONTROLLERS FOR NT, MT AND LT APPLICATIONS, HACCP REQUIREMENTS Advanced multifunction refrigeration controllers to meet HACCP requirements Monitoring, signaling and recording of the critical temperature Store product correctly Hand held infrared reader unit to download from the controllers all the data and to transfer them directly to a printer Direct line power supply 230 (110)Vac. No external transformer required Instant visibility of machine status via display icons Clear alarm signals thanks to the front lid Fast and easy wiring Designed to be wall or panel mounted Standard communication protocol ModBUS-RTU Hot key or Prog tool kit connector for a quick and easy programming 10VA max power absorption Dual display with red LED (25,3mm high) and yellow LED (20,3mm high) and 17 icons HOW TO ORDER XLR700 X L R 7 - A 0 0 D E Power supply A D E Measurement unit Built in RS485 1 = 24Vac 4 = 110Vac 5 = 230Vac 8 = 110 230Vac C = C F = F 0 = No 1 = Yes 66

DISPLAY ICONS MEANING Celsius degrees Fahrenheit degrees High temperature alarm Low temperature alarm Critical temperature (min or max) Comsor active active Light on Stand-by Digital input alarm Alarm list Clock Date Infrared transmission It signals The function menu Start time End time COMPLETE The dual display and the 17 icons show complete information about the status of the machine. Without the need to enter into the programming mode, all the main functioning of the cooling system are displayed with only one key touch. : THE INFRARED FACILITY An optional hand held infrared reader unit is available to download from controllers (up to 40) all the recorded data and to transfer them directly to a printer provided with IR port. A PC is not required. See pg 47 for main windows A typical report with alarms EG. HIGH TEMPERATURE ALARM BLACKOUT ALARM When a high (or low) temperature alarm occurs, the instrument records the start 1 and end time 2, the date and the maximum (or minimum) temperature 3 reached. If, after a blackout, the temperature is higher than the alarm value, the start of the blackout 1 and the end of alarm temperature 2 together with the max temperature reached 3 are recorded. 67

XLR700 COOL MATE ADVANCED MULTIFUNCTION CONTROLLERS for N., M. and L. TEMPERATURE COLD ROOMS with HACCP REQUIREMENTS XLR730 Digital controller for N.T. with off cycle defrost with HACCP function 230x210mm XLR770 Digital controller for M.T. and L.T. ventilated applications with HACCP function FEATURES First display: n digits Second display: n digits Keyboard: push buttons Power supply Probe inputs Thermostat Display Digital inputs Alarm, block alarm, sure switch, start defrost, energy saving, ON/OFF, AUX, holiday Door switch Relay outputs Comsor Fans Light AUX Alarm Other Hot Key/Prog Tool Kit output Serial output Infrared output Buzzer Real time clock XLR730 ± 4 d.p. 6 24, 110, 230Vac XLR770 ± 4 d.p. 6 24, 110, 230Vac XLR730 XLR770 68

PARAMETERS REGULATION Set point Differential Minimum set point Maximum set point Outputs activation delay at start up Comsor uration Anti-short cycle delay 2 nd comsor cycle delay Comsor ON time during fast freezing Comsor ON time with faulty probe Comsor OFF time with faulty probe Kind of action (cooling /heating) DISPLAY Temperature measurement unit Resolution (integer/decimal point) Local display uration DEFROST type mode Set point for smart defrost termination temperature (1 st ev.) termination temperature (2 nd ev.) Interval between defrost cycles (Maximum) length for defrost (1 st ev.) (Maximum) length for defrost (2 nd ev.) Displaying during defrost Max display delay after defrost start delay after a call Draining time First defrost after startup delay after fast freezing termination probe selection termination probe selection (2 nd ev.) FANS Fans operating mode Fans delay after defrost Fans stop temperature Fans probe selection ALARMS Temperature alarm differential Temperature alarm delay Delay of temperature alarm at start up Alarm delay after the defrost Open door alarm delay Alarm relay silencing Pressure switch activation number Alarm probe selection ANALOG INPUTS Thermostat probe calibration Evaporator probe calibration Auxiliary probe calibration Evaporator probe ence Auxiliary probe ence Regulation probe selection Temp. increasing during en. saving cycle DIGITAL INPUT Open door control Door switch polarity Configurable digital input polarity Alarm delay from digital input TIME AND WEEKLY HOLIDAYS Current hour Current minute Current day of the week Current day Month Year First weekly holiday Second weekly holiday Third weekly holiday ENERGY SAVING TIMES Energy Saving cycle start time during workdays Energy Saving cycle duration during workdays Energy Saving cycle start time on holidays Energy Saving cycle duration on holidays Temperature increase during the Energy Saving cycle DEFROST TIMES start time on workdays start time on holidays OTHER Language selection for iprint Serial address Map code Software release Room probe readout Evaporator probe readout Third probe readout CODE Set Hy LS US OdS CC0 AC AC1 CCt Con COF CH CF res Lod tdf EdF SdF dte dts IdF MdF MdS dfd dad dsd Fdt dpo daf dfp dsp Fnc Fnd FSt FAP AFH ALd dao EdA doa tba nps ALP Ot OE O3 P2P P3P Pbr HES OdC i1p i2p did Hur Min UdA day MOn YEA Hd1 Hd2 Hd3 ILE dle ISE dse HES Ld1-Ld8 Sd1-Sd8 PLA Adr Ptb rel dp1 dp2 dp3 XLR730 XLR770 Present Present and password protected 69

PANEL MOUNTING WALL MOUNTING 230x210mm XLH200/300 COOL MATE SERIES: CONTROLLERS FOR NT, MT, LT AND MATURING APPLICATIONS, TEMPERATURE/HUMIDITY MANAGEMENT Advanced multifunction controllers with temperature and humidity management Cooling and heating action for safe storage of products management Possibility of excluding humidity control Dehumidifying action by cooling circuit Running and stopping programmable cycles with different set points (XLH300) Automatic cycles of extraction fans (XLH300) Direct line power supply 230 (110)Vac. No external transformer required Instant visibility of machine status via display icons Clear alarm signals thanks to the front lid Designed to be wall or panel mounted Standard communication protocol ModBUS-RTU Hot key or Prog tool kit connector for a quick and easy programming 10VA max power absorption Dual display with red LED (25,3mm high) and yellow LED (20,3mm high) and 17 icons HOW TO ORDER XLH200/300 X L H - A 0 0 D E A D E Power supply Measurement unit Built in RS485 1 = 24Vac C = C 0 = No 4 = 110Vac F = F 1 = Yes 5 = 230Vac 8 = 110 230Vac 70

DISPLAY ICONS MEANING Celsius degrees Fahrenheit degrees Comsor Heater control Alarm Fans Extractor fans RH% Dehumidifying Humidifying Temperature and humidity setting Running cycle Cycle duration setting Light Stand-by COMPLETE The dual display and the 17 icons show complete information about the status of the machine. Without the need to enter into the programming mode, all the main functioning of the cooling system are displayed with only one key touch. XLH200: TEMPERATURE AND HUMIDITY CONTROL A neutral zone algorithm is used both for temperature and humidity. Temperature Cooling area Instruments are provided with a comsor output (with defrost) and heating elements to control temperature. Set Neutral zone Time Humidifier and dehumidifier (depending on model) outputs are provided for humidity. This assures both Heating area variables are kept inside the set band (neutral zone) Comsor On Heater On XLH300: EG. MATURING CYCLE WITH RUNNING AND STOPPING PHASE Temperature Set 1 T1: pre-cycle only with temperature control Set 2 Humidity T1 Running T2 T3 Stopping T2 Time T2: cycle with temperature and humidity control Set 2 RH T3: stopping phase T1 T2 T3 T2 Time 71

XLH200/300 COOL MATE ADV. MULTIFUNCTION CONT. with TEMP./HUM. MANAGEMENT for N., M. and L. TEMP. COLD ROOMS and MATURING ROOMS 230x210mm XLH260 XLH360 XLH380 Digital controller for N.T. and L.T. cold rooms with temperature and humidity management Digital controller for maturing rooms with temperature and humidity management Digital controller for maturing rooms with temperature and humidity management plus alarm relay FEATURES First display: n digits Second display: n digits Keyboard: push buttons Power supply Probe inputs Thermostat Humidity Digital inputs Alarm, block alarm, sure switch, start defrost, energy saving, ON/OFF, AUX, holiday Door switch Relay outputs Comsor, extractor fans Fans Heater control Humidifying Dehumidifying, light Alarm Extractor fans Other Hot Key/Prog Tool Kit output Serial output Buzzer XLH260 XLH360 XLH380 ± 4 d.p. 6 24,110, 230Vac 4 20mA opt ± 4 d.p. 8 24,110, 230Vac 4 20mA opt ± 4 d.p. 8 24,110, 230Vac 4 20mA 5A 5A 5A opt XLH260 XLH360 XLH380 72

PARAMETERS REGULATION Temperature set point Humidity set point Half dead band width for temperature Half dead band width for humidity Minimum temperature set point limit Maximum temperature set point limit Outputs activation delay at start up Anti-short cycle delay Humidity regulation Minimum humidity set point limit Maximum humidity set point limit DISPLAY Measurement unit Resolution for temperature Resolution for humidity DEFROST Instrument actions at the end of the cycle type mode Set point for Smart termination temperature Interval between defrosts Duration of defrost Display during defrost display time out Drain down time First defrost after start up Humidity control during defrost FANS Fan operating mode Interval between 2 cycles of change of air Duration of cycle of change of air ALARM Temperature alarm uration Low temperature alarm setting High temperature alarm setting Temperature alarm recovery differential Temperature alarm delay Delay of temperature alarm at start-up Alarm delay at the end of defrost Delay of temperature alarm after closing the door Humidity alarm uration Low humidity alarm setting High humidity alarm setting Humidity alarm recovery differential Humidity alarm delay Delay of humidity alarm at start-up Alarm delay at the end of defrost Open door alarm delay Max number of Pressure Switch activations ANALOG INPUT Thermostat probe calibration Evaporator probe calibration Humidity probe calibration Evaporator probe ence Humidity probe ence DIGITAL INPUT Readout at 4mA Readout at 20mA Digital input polarity Digital input uration Outputs status when open door Outputs regulation restart after door open alarm Digital input alarm delay OTHER 1 st relay uration 2 nd relay uration 3 rd relay uration Serial address Map code Software release Probe display CODE Set T Set H dbt dbh LS us ods Ac thu LSH ush cf res reh trc tdf EdF SdF dte idf MdF dfd dad Fdt dpo Hud Fnc rfi rfd ALc ALL ALu ALH ALd dao EdA dot AHc AHL AHu AHH AHd dho doh doa nps Ot oe o3 P2P P3P Lci uci i1p i1f odc rrd did oa1 oa2 oa3 Adr Ptb rel Prd XLH260 XLH360 XLH380 Present Present and password protected 73

100x64mm XW200/500 + V-KIT SERIES: CONTROLLERS FOR MT, LT APPLICATIONS V-KIT: a wall / panel mounting housing kit for vertical format keyboards (V600 and V800 series). For remote connection to XW200K and XW500K Series refrigeration controllers Designed for cold rooms applications LT and MT models available Connections: 2 wire electric cable up to 100m P55 against water sprinkles Easy and quick to install 100m maximum distance is possible Direct line power supply 230 (110)Vac from the controller. No external transformer required Standard communication protocol ModBUS-RTU Hot key or Prog tool kit connector for a quick and easy programming 10VA max power absorption Display with red LED (13,2mm high) COLD ROOM APPLICATION The Dixell V-KIT allows the user to mount the keyboard near to the cold-room door. Connection between the power board (eg. XW270K) and the keyboard is via a 2 core cable. The maximum distance possible is 100m. The door-switch facility is activated when the door is open, the light is automatically switched on, while the comsor, up to 1.5HP, and the evaporator fan can be simultaneously stopped. The innovative design of this housing gives a quick and effective solution for a variety of different applications, such as cold-rooms, benches and industrial environments where it is difficult to mount the keyboard on a wall. It s available in 3 different colours making it suitable for all applications, even where appearance plays part. A main feature is ease of assembly and with IP55 protection, it can be used in environments that may be subject to water spray or rigorous cleaning routines. The V-KIT is suitable for all vertical format keyboards. For more information about keyboards and WING modules that can be used with V-KIT, please check the information regarding XW200/500 Series. 74

BLAST CHILLER/FREEZER REFRIGERATION CONTROLLERS SECTION INDEX FUNCTIONS MODELS XB500 - BLAST CHILLER AND TEMPERATURE MAINTENANCE APPLICATION - PRINTING OPTION Blast chiller digital controllers and printer XB05PR - XB570C - XB570L XB500 series parameters 76 78 80 75