HEATING AND COOLING EFFECT USING VAPOUR COMPRESSION CYCLE

Similar documents
Heat utilization from refrigerator condenser using water heater and hot box

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

II. OBJECTIVE OF RESEARCH

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Enhancement of COP in Vapour Compression Refrigeration System

Heat Recovery from Refrigerator Using Water Heater and Hot Box

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Adsorption refrigeration system using waste heat

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Performance Assessment of Water Cooled Condenser Refrigeration System

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Scientific Journal Impact Factor: (ISRA), Impact Factor: Methodology. [Yadav, 3(9): September, 2014] ISSN:

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Performance investigation of Air-conditioning system using ejector as expansion device

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Performance Optimization of the Evaporative Condenser Design

CHAPTER 1 INTRODUCTION

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Design & Fabrication of Hybrid Cooler

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

A Review of Different Types of Combine Cooling System

MODERN EVAPORATIVE COOLER

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Reheating Refrigeration System

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Design and Development of Water Cooled Condenser for Domestic Refrigerator

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Fabrication of Hot and Cold Water Dispenser

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

(Refer Slide Time: 00:00:40 min)

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Pressure Enthalpy Charts

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

CHAPTER 1 INTRODUCTION

Enhancement of COP using Nanoadditives in Domestic Refrigerator

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Numerical Simulation of Window Air Conditioner

EXPERIMENTAL INVESTIGATION ON RECOVERY OF WASTE HEAT FROM WINDOW AIR CONDITIONER

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Performance Study of Triple Concentric Pipe Heat Exchanger

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Waghmare Tushar Ramrao, D.S.Nakate

Global Journal of Engineering Science and Research Management

ISSN: [Agcaoili S. O., 7(3): March, 2018] Impact Factor: 5.164

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Fabrication of A Prototype for Condensation of Water on Metal Surface Using Peltier Modules

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

REFRIGERATION AND AIR CONDITIONING

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

HVAC Fundamentals & Refrigeration Cycle

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Transcription:

HEATING AND COOLING EFFECT USING VAPOUR COMPRESSION CYCLE Mr. Adnan Noor Sonday 1, Ms. Bency Saji 2, Mr. Chandanshive Vaibhav Swamirao 3, Mr. Mukhmale Gopal Madhukar 4, Prof. Sachin Yadav 5 1,2,3,4 Students of Mechanical Engineering Department 5 Assistant Professor in Mechanical Engineering Department, Genba Sopanrao Moze College of Engineering, Baner-Balewadi, Pune. Pune, MH (India) ABSTRACT Heat is energy, so energy saving is one of the key matters from view point of fuel consumption and for the protection of global environment. So it is necessary that a significant and concrete effort should be made for conserving energy through waste heat recovery too. The main objective of this paper is to study Waste Heat recovery system for domestic refrigerator. An attempt has been made to utilize waste heat from condenser of refrigerator. This heat can be used for number of domestic and industrial purposes. In minimum constructional, maintenance and running cost, this system is much useful for domestic purpose. It is valuable alternative approach to improve overall efficiency and reuse the waste heat. The study has shown that such a system is technically feasible and economically viable. I. INTRODUCTION Today the world has made impressive progress in the field of industry, agriculture, communication, transport, and other sectors. Due to this rapid development and population growth world s thirst of energy has increased tremendously. We all want to brighter tomorrow but to accomplish this we need to be a little brighter about how we make use of energy effectively at work and at home. The best is that by helping ourselves we help others and help to secure brighter future of world. As we know a significant amount of energy is wasted in every field of application. So, valuable alternative approach for improving overall energy efficiency is to capture and reuse the lost or Waste Heat (Energy). We can say energy saved is as good as energy generated. In modern era percentage of educated people is more. However the literacy about energy saving while consuming it is quite essential and must be widely spread for brighter tomorrow. This can be best achieved by setting examples starting from our home, as charity begins from home. This should be achieved without spending addition money and without additional work load in the fast moving world of today. With this intension only we have planned to construct waste heat recovery system for domestic refrigerator. So our project is a helping hand for such people and also it can throw light on energy consumption. Waste Heat Recovery from Condenser of Domestic Refrigerator is a valuable alternative approach to improve overall efficiency and reuse the lost or waste heat. 233 P a g e

This is definitely going to increase COP of the refrigerator. In this we are going to utilize waste heat from condenser of refrigerator for various household applications like hot pot, oven, dryers, etc. In minimum constructional cost as well as minimum running and maintenance cost, our project is much applicable for domestic purpose. II. PROBLEM STATEMENT A lot of heat is wasted from the condenser of refrigerator. This lost heat creates warming of kitchen. Also due to waste of heat the COP of the refrigerator decreases which hinders the refrigerating effect of refrigerator. Heat wasted is responsible for global warming. An energy crisis is the biggest issue incurring due to waste heat. To overcome these problems waste heat recovery is carried out. III. OBJECTIVE The main objective of this project is to study Waste Heat recovery system for domestic refrigerator. An attempt has been made to utilize waste heat from condenser of refrigerator. This heat can be used for number of domestic and industrial purposes. In minimum constructional, maintenance and running cost, this system is much useful for domestic purpose. It is valuable alternative approach to improve overall efficiency and reuse the waste heat. The study has shown that such a system is technically feasible and economically viable. IV. METHODOLOGY A typical vapor compression system consist of four major components viz. compressor, condenser, expansion device and an evaporator are depicted schematically in.figure 1 is a thermodynamic diagram of the process where the numbered points correspond to the numbered points in Figure1.The operation cycle consist of compressing low pressure vapor refrigerant to a high temperature vapor(process 1-2); condensing high pressure vapor to high pressure liquid (process 2-3); expanding high pressure liquid to low pressured super cooled liquid (process 3-4); and evaporating low pressure liquid to low pressure vapor (process 4-1). The heat absorbed from evaporator in process 4-1 is rejected to outside ambient during condensation process 2-3 and is generally a waste heat. The condensation process can be divided in 3 stages viz. desuperheating2-2a, condensation and sub cooling. The saturation temperature by design is anywhere from ten to thirty degree above the heat sink fluid temperature, this ensure the heat sink fluid can extract heat from the refrigerant. The superheat can be as much as 100 F or more above the saturation temperature. This so-called superheat is a part of waste heat that can be recovered for useful purposes through the use of a heat recovery unit. A heat recovery unit is special purpose heat exchanger specifically designed to: 1.Remove heat represented by 2-3 in figure 1. 2. Improve overall system efficiency by using water cooled condenser. 3. Use thermo syphon system to circulate water to minimize pumping cost. 4. Protect against contamination of portable water via double wall construction. 234 P a g e

Fig.1 P-H diagram V. LITERATURE REVIEW 1] Raut Digambar M, Narawade Kiran H, Karale Vidur S, Pardeshi Kiransing V, Kabudke P.D evaluated the contribution towards the waste heat recovery in the paper HEAT UTILIZATION FROM REFRIGERATOR CONDENSER USING WATER HEATER AND HOT BOX.The purpose of this paper is to recover condenser heat by implementing in water heater and hot box. This project describes the development and use of new type of multipurpose refrigerator- a refrigerator with hot box and water heater. Normal refrigerator works on VCC, extract heat from substance to be cooled and exert that heat to the atmosphere through the device called condenser. That refrigerator which is been previously made to exert a lot of heat through condenser is modified to overcome this wastage of heat. For recovery of that waste heat we decide to develop a machine which utilizes that waste heat for heating hot case and heating water with the use of water heater. The main important thing in our model is, it does not require any kind of additional power supply for its working operation. As the energy saving plays vital role in development, our model has lot of importance from that particular point of view. Another interesting thing in this project is that it performs operation without disturbing original refrigerator working. 2] S. C. Walawade, B. R. Barve, P. R. Kulkarni had explained the waste heat recovery system in the paper DESIGN AND DEVELOPMENT OF WASTE HEAT RECOVERY SYSTEM FOR DOMESTIC REFRIGERATOR.Heat is energy, so energy saving is one of the key matters from view point of fuel consumption and for the protection of global environment. So it is necessary that a significant and concrete effort should be made for conserving energy through waste heat recovery too. The main objective of this paper is to study Waste Heat recovery system for domestic refrigerator. An attempt has been made to utilize waste heat from condenser of refrigerator. This heat can be used for number of domestic and industrial purposes. In minimum constructional, maintenance and running cost, this system is much useful for domestic purpose. It is valuable alternative approach to improve overall efficiency and reuse the waste heat. The study has shown that such a system is technically feasible and economically viable. 3] J.K. Gupta, M. Ram Gopal has worked on hot well condenser in the paper MODELING OF HOT-WALL CONDENSERS FOR DOMESTIC REFRIGERATORS. A mathematical model of hot-wall condensers that are commonly used in domestic refrigerators is presented. The model predicts the heat transfer characteristics of condenser and the effects of various design and operating parameters on condenser tube length and capacity. In the present model, the condenser tube is divided into 235 P a g e

elemental units, with each element consisting of adhesive aluminum tape, refrigerant tube and outer metal sheet. The heat transfer characteristics of the condensers are then analyzed by considering the heat transfer through the tube wall, aluminum tape and the outer sheet. Variations in inner heat transfer coefficient and pressure drop are considered depending on temperature, fluid phase, type of flow and orientation of tube. Variation in ambient heat transfer coefficient is also taken into account. Results obtained are very much in accordance with the physics of the problem and agree fairly well with the published experimental data on hot-wall condensers. The study shows that the aluminium tape used to stick the condensing tube to the outer sheet plays a significant role in heat transfer from condenser to environment. The model presented here can thus be used for accurate design and analysis of hot-wall condensers. 4] Gustavo Pottker, Pega Hrnjak has explained the effect of subcooling in the paper EFFECT OF THE CONDENSER SUBCOOLING ON THE PERFORMANCE OF VAPOUR COMPRESSION SYSTEMS. This paper presents a theoretical study about the effect of condenser subcooling on the performance of vapourcompression systems. It is shown that, as condenser subcooling increases, the COP reaches a maximum as a result of a trade-off between increasing refrigerating effect and specific compression work. The thermodynamic properties associated with the relative increase in refrigerating effect, i.e. liquid specific heat and latent heat of vaporization, are dominant to determine the maximum COP improvement with condenser subcooling. Refrigerants with large latent heat of vaporization tend to benefit less from condenser subcooling. For an air conditioning system, results indicate that the R1234yf (þ8.4%) would benefit the most from condenser subcooling in comparison to R410A (7.0%), R134a (5.9%) and R717 (2.7%) due to its smaller latent heat of vaporization. On the other hand, the value of COP maximizing subcooling does not seem to be a strong function of thermodynamic properties. VI. WORKING PRINCIPLE As a part of project we had planned to use water cooled condenser replaced by air cooled condenser. The aim of using water cooled condenser is that to get more and more heat for water heating for continuous flow, maintain optimum level of water in a hot pot and proportional draining float is used. Whenever there is no need of hot water, at that time hot pot can be kept empty and the lid may be exposed to atmosphere for air circulation. Thus, the refrigerator works normally. Fig.2 Working Principle of Vapour Compression System 236 P a g e

Fig 3. Experiment setup. VII. FABRICATION OF CABIN The insulation pot is made up of:- 1. Inner box of pot 2. Insulation material 3. Outer box of pot 1. Inner box of pota. Readymade inner box (i.e. oil container of 15 ml) is used. b. The standard dimension is 22X22X26 cm. c. And this cabin is painted by silver colour 2. Insulation material- Insulation material is essential to minimize the heat transfer between cabin and surrounding. Best insulation material for our project purpose is PUF (polyurethane foam) Fig. 4 Inner Box of Pot 237 P a g e

3. Outer box of pot- a. Outer box is fabricated in stainless steel as per our design which is outsourced. b. The size of outer box is 30X30X36 cm Fig. 5 Outer Box of Pot VIII. CALCULATION FOR INCREASED RATE OF WASTE HEAT Heat Recovery Achieved (Q) = Heat absorbed by water + Heat absorbed by hot pot Rejected heat in air Part [I]: Heat absorbed by water (Q 1 ) Given data: Mass of water input (M) = 12.1 = 12100 gm Specific heat of water = 4.184 J/gm o C Initial temperature of water = 31.7 o C Final temperature of water = Time required for reading (t) = Heat absorbed by water (Q 1 ) = MCp*(difference in temperature/t) Part [II]: Heat absorbed by hot pot (Q 2 ) Length of hot pot (L) = 30cm Breadth of hot pot (B) =30cm Height of hot pot (H) = 38cm Initial temperature of water = 31.7 o C Final temperature of water = Air/Room Temperature = 32.2 o C Area of hot pot:- A = 2 (LB + BH + HL) 238 P a g e

A = 2 (30 X30 + 30 X 38 + 38 X30) A = 6360cm 2 A = 0.636m 2 Thermal Conductivity of Composite Hot Pot- 1/u = b1/k2 + b2/k2 + b3/k3 ` Fig. 6 Thermal Conductivity of Composite Hot Pot Heat absorbed by hot pot (Q 2 ): Q 2 = ua *(difference in temp/ dx) Part [III]: Heat rejected through condenser in atmospheric air(q 3 )- Let us assume that, there is 5% loss in air through condenser. Therefore, Q 3 = 5% Of (Heat absorbed by water + Heat absorbed by hot pot) Part [IV]: Heat Recovery Achieved (Q) = Heat absorbed by water + Heat absorbed by hot pot Rejected heat in air IX. FUTURE SCOPE It enhances efficiency of system. Waste heat that is rejected by the fridges, coolers in large commercial areas like industries, hotels, health care centers, it can be used to utilize the worm water to wash the cans in dairy, figure bowl water etc. Further using same project the heat generated in the kitchen will be less as it is utilized for heating water. It can also help in reducing kitchen temperature & make kitchen more comfortable to some extent. The hot pot can also be used as dryer. The snacks, food, grains can be warmed by keeping the utensils in empty hot pot. 239 P a g e

X. CONCLUTION Waste heat recovery system is an excellent tool to conserve available energy. If this can be started from individual level then it can sum up and enormous effect can be obtained. Thus with small addition in cost if we recover and reuse the waste heat, then definitely we can progress towards energy conservation and simultaneously achieve our day today function. As indicated in our project this waste heat can be utilized in various ways. In the fast moving world of today where time is short we can use this as food and snacks warmer, water heater, grain dryer. So we can save lot of time and energy also. In present situation where everybody in a home is moving out this combination of refrigerator and water heater is definitely a boom to efficient house wife & commercial XI. ACKNOWLEDGMENT We on the behalf of this acknowledgement wants to thanks those persons and resources due to which we are able to complete the Study Work. First of all we would like to thanks IJRDT for their Idea to engage usin such activity due to which We students open up to vast engineering applications. We also would like to express our Gratitude to our respected H. O. D. of Mechanical Engineering Department Dr. P. A. Makasare and our guide Prof. S.S Yadavand All Faculty Members for their planning and guidance which proved to be a milestone in this Completion. We would like to thanks to our college who opened the doors of vast knowledge. We are also grateful to our parents and friends for their help and Encouragement. REFRENCE [1] Khurmi R.S. J K Gupta A Textbook of Refrigeration and Air Conditioning, S Chand & Co Ltd publication 2006. [2] R.B. Slama Refrigeartor Coupling to a Water-Heater and Heating Floor to Save Energy and to Reduce Carbon Emissions January 2013,http://www.scirp.org/journal/cweee [3] Sreejith k. Experimental Investigation of a Domestic Refrigerator Having Water-Cooled Condenser Using Various Compressor Oils, International Journal of Engineering and Science,www. Researchinventy.com [4] Lon E. Bell Cooling,Heating,Generating Power, and Recovering Waste Heat with Thermoelectric Systems. www.sciencemag.org science. [5].C. Arora, Refrigeration and Air conditioning, PHI publications, 2010 240 P a g e