Suzhou VICTOR Medical Equipment Co., Ltd

Similar documents
INSTRUCTION / INSTALLATION / TECHNICAL MANUAL

Flexibility and individual design turn your dental unit into an active partner. Quality is not a consideration quality is the solution

Fimet F1 User Guide Version

CHIRANA Medical, a. s.

Unlimited Mobility. The Mobile Dental Units From. B-Productions

Dynamics Precision Speed

DENTAL UNIT. Rod Type OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

FONA DURION Dental unit operation instruction

OPERATING INSTRUCTIONS

Dental Unit (FDA&CE certificated) Autoclave(CE certificated) Catalogue

Packing. Euronda Spa t (+39) m euronda.com

Unlimited Mobility The Mobile Dental Units By. BPR Swiss

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

CHAPTER 7 LAUNCH SITE

CHEE YUEN GO GREEN CHEE YUEN INDUSTRIAL COMPANY LIMITED QUALITY PRODUCTS SINCE 1965

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

ECL Comfort V a.c. and 24 V a.c.

Classic Twelve O clock Cabinet Installation Instructions

Apre 2 in 1 Electric Breast Pump

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

Section XX MISC LLANEOUS MANUFACTURED ARTICLES. Chapter 94

Important Notes: Please read carefully before installing your refrigerator.

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

SEASHELL Armchair, stackable

ZL High-efficiency Vacuum Insulation Oil Purifier

On the Production of Submarine Equipments to support the Submarine Cable Business. December 5 th, 2008 NEC Yamanashi, Ltd. President Ikuo Mito

INNOVATIVE ACOUSTIC RESONANCE SYSTEM

ECL Comfort 300 / V a.c. and 24 V a.c.

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

重庆阳江机械制造有限公司. Electricity factory Transformer station Oil connection stations Transformer repair shop

I/A Series 716C 1/16 DIN Temperature Controller

FOR YOU AND YOUR CUSTOMER

VM-3000 Mercury Vapor Monitor

BlueSpin Magnetic Hotplate Stirrer

CLETEF-786. Infrared Thermometer Instruction Manual

USER MANUAL. Soho All-In-One Chair Rev A 4/23/18. *shown with optional accessories and/or finishes. Earthlite 2018, All Rights Reserved

InstructIons for use A-dec 561 Cuspidor

Care instructions ESTETICA E80. Always be on the safe side.


... take a seat. Ritter made in germany

Reliable Solid Simple

Jiangsu Dynamic Medical Technology Co.,Ltd.

Hot Water Heating Systems

fixflow Fixed & Adjustable Temperatures WR-ZY-822D

Course Reference Material Required for EWRB Examinations 2018

arco The new generation of gynaecological examination chairs

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

Xpert HD Xpert HD 7140, ,

DÜRR SUCTION SYSTEMS. High demands reliably exceeded DÜRR AMALGAM SEPARATORS

OVEN INDUSTRIES, INC.

LOGIC CONTROLLED DEKO 25 EASE OF USE

Invacare Propad. General. Cushion User Manual. General information. Warranty. Standards and regulations. Symbols in this user manual.

Quick Pick Furniture Program

OWNER S MANUAL. Sears McKenna 5PC Chat Set. * Lounge Swivel Rocker. Product Code: D71 M18452 UPC Code: Date of Purchase: / /

PALUX FRY STAR INNOVATIVE FRYING SERIES

RELIABILITY AND TECHNOLOGY, SUITABLE FOR EVERY STYLE. MIGLIONICO.NET

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

User manual Whirlpool

COMPANY Presentation Focus on SANDEN Environmental Solutions

YUME SHAMPOO UNIT INSTALLATION INSTRUCTIONS

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Comfort Stylish Design Relaxation

Desicators & Dry Cabinets

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

THE WESTWOOD. Experience holiday home living at its finest.

TECHNOLOGY IMPREGNATION

Planmeca Sovereign Classic

Short instructions for use ESTETICA E30

Shiatsu Massage Cushion

Mercury Vapor Monitor VM-3000

Standard SPECIFICATIONS FEATURES APPLICATIONS

User Manual. Non-contact Infrared Thermometer.

INSTALLATION INSTRUCTIONS DÜRR MOTORSEPA S 300

THE DINING COLLECTION

Swivel and visitor chairs crossline prime & crossline

PDA20DX Air Purifying Dehumdifier Manual

Affordable wireless monitoring without compromise

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Hot water compact class HDS 5/12 C *AU

DENTAL TABLE TOP STERILIZER SERIES S CLASS MODEL : MO-MOST-T24/45/80.

TETHYS H10 PLUS. As a result of constant technological updating, the technical data may be subject to change without prior notice.

Product Manual. Argon (AMC 1020)

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

Penetrates Deep To Kill Ants, Houseflies, Mosquitoes, Cockroaches And Fleas Where They Hide.

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

VM-3000 Mercury Vapor Monitor

Short instructions for use ESTETICA E30

Instructions for use KaVo Primus 1058 S/TM/C/G. Always be on the safe side.

Group 2: AutoBott. David Rooney, C.P.E. Steven Lo, C.P.E. Eric Velazquez, E.E. Antonio Orosa, E.E.

CENTRAL SUCTION SYSTEMS. Dry / semi-wet suction For 1-15 dental units Underpressure of 180 mbar

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

Conference & executive swivel chair se:line

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

qube mini Overview

#1 BRAND IN MASSAGE* HMC-300MASSAGECHAIR INSTRUCTION MANUAL AND WARRANTY INFORMATION TWO YEAR LIMITED WARRANTY HMC-300

Transcription:

Suzhou VICTOR Medical Equipment Co., Ltd TYPE:COMPUTER CONTROLLED INTEGRAL DENTAL UNIT: VM2000 Factory configuration: 1: full computer control, mute the low-voltage DC motor drive 2:180 degree swivel and easy to clean toughened glass spittoon 3: cupping, rinse water injection control system of quantitative 4: Electric dental chair control system with three memory spaces 5: cushion and backrest spacious and with compensation 6: Built-in water purification system 7: Luxury Designed mouth 8: Built-in constant temperature heating system 9: LED lights view films 10: strong and weak absorption bed system 11: Doctors mounts

Technical parameters 1: 220 plus or minus 10V 50Hz input power 2: The water pressure 0.2-0.4Mpa 3: air pressure 0.5-0.6Mpa 4: The total mass of 250KG Optional 1: import or domestic four-hole high-speed mobile phone 2: import or domestic four-hole low-speed mobile phone 3: mouth sputum microscopy system 4: Scaler 5: Light curing machine 6: All the computer equipment on the hook plate

TYPE:COMPUTER CONTROLLED INTEGRAL DENTAL UNIT: VM6018 Integral dental unit: VM6018 Factory configuration 1: full computer control, mute the low-voltage DC motor drive 2:180 degree swivel and easy to clean toughened glass spittoon 3: cupping, rinse water injection control system of quantitative 4: Electric dental chair control system with three memory spaces 5: cushion and backrest spacious and with compensation 6: Built-in water purification system 7: Luxury Designed mouth 8: Built-in constant temperature heating system

9: LED lights view films 10: strong and weak absorption bed system 11: Doctors mounts Optional 1: import or domestic four-hole high-speed mobile phone 2: import or domestic four-hole low-speed mobile phone 3: mouth sputum microscopy system 4: Scaler 5: Light curing machine 6: All the computer equipment on the hook plate Technical parameters 1: 220 plus or minus 10V 50Hz input power 2: The water pressure 0.2-0.4Mpa 3: air pressure 0.5-0.6Mpa 4: The total mass of 250KG

TYPE:COMPUTER CONTROLLED INTEGRAL DENTAL UNIT: VM8018 Factory figuration 1: full computer control, mute the low-voltage DC motor drive 2:180 degree swivel and easy to clean toughened glass spittoon 3: cupping, rinse water injection control system of quantitative 4: Electric dental chair control system with three memory spaces 5: cushion and backrest spacious and with compensation 6: Built-in water purification system 7: Luxury Designed mouth 8: Built-in constant temperature heating system 9: LED lights view films

10: strong and weak absorption bed system 11: Doctors mounts Optional 1: import or domestic four-hole high-speed mobile phone 2: import or domestic four-hole low-speed mobile phone 3: mouth sputum microscopy system 4: Scaler 5: Light curing machine 6: All the computer equipment on the hook plate Technical parameters 1: 220 plus or minus 10V 50Hz input power 2: The water pressure 0.2-0.4Mpa 3: air pressure 0.5-0.6Mpa 4: The total mass of 250KG

TYPE: COMPUTER CONTROLLED INTEGRAL DENTAL UNIT: VM8050 Factory configuration 1: full computer control, mute the low-voltage DC motor drive 2:180 degree swivel and easy to clean toughened glass spittoon 3: cupping, rinse water injection control system of quantitative 4: Electric dental chair control system with three memory spaces 5: cushion and backrest spacious and with compensation 6: Built-in water purification system 7: Luxury Designed mouth 8: Built-in constant temperature heating system 9: LED lights view films 10: strong and weak absorption bed system 11: Doctors mounts Optional

1: import or domestic four-hole high-speed mobile phone 2: import or domestic four-hole low-speed mobile phone 3: mouth sputum microscopy system 4: Scaler 5: Light curing machine 6: All the computer equipment on the hook plate Technical parameters 1: 220 plus or minus 10V 50Hz input power 2: The water pressure 0.2-0.4Mpa 3: air pressure 0.5-0.6Mpa 4: The total mass of 250KG

TYPE:COMPUTER CONTROLLED INTEGRAL DENTAL UNIT: VM9090 Factory configuration 1: full computer control, mute the low-voltage DC motor drive 2:180 degree swivel and easy to clean toughened glass spittoon 3: cupping, rinse water injection control system of quantitative 4: Electric dental chair control system with three memory spaces 5: cushion and backrest spacious and with compensation 6: Built-in water purification system 7: Luxury Designed mouth 8: Built-in constant temperature heating system 9: LED lights view films

10: strong and weak absorption bed system 11: Doctors mounts Optional 1: import or domestic four-hole high-speed mobile phone 2: import or domestic four-hole low-speed mobile phone 3: mouth sputum microscopy system 4: Scaler 5: Light curing machine 6: All the computer equipment on the hook plate Technical parameters 1: 220 plus or minus 10V 50Hz input power 2: The water pressure 0.2-0.4Mpa 3: air pressure 0.5-0.6Mpa 4: The total mass of 250KG

TYPE: COMPUTER CONTROLLED INTEGRAL DENTAL UNIT: VM9108 Computer controlled integral dental unit: VM9108 Factory configuration 1: full computer control, mute the low-voltage DC motor drive 2:180 degree swivel and easy to clean toughened glass spittoon 3: cupping, rinse water injection control system of quantitative 4: Electric dental chair control system with three memory spaces 5: cushion and backrest spacious and with compensation 6: Built-in water purification system 7: Luxury Designed mouth 8: Built-in constant temperature heating system 9: LED lights view films 10: strong and weak absorption bed system 11: Doctors mounts Optional

1: import or domestic four-hole high-speed mobile phone 2: import or domestic four-hole low-speed mobile phone 3: mouth sputum microscopy system 4: Scaler 5: Light curing machine 6: All the computer equipment on the hook plate Technical parameters 1: 220 plus or minus 10V 50Hz input power 2: The water pressure 0.2-0.4Mpa 3: air pressure 0.5-0.6Mpa 4: The total mass of 250KG