DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Similar documents
DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

DCG Commercial. Submittal Data Form

50TM TFF COMBINATION HEATING/COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM COMBINATION HEATING/COOLING UNITS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. Fig. 1 - Unit 50VR -A

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

48TM GAS HEATING/ELECTRIC COOLING UNITS

48PGD/E/F/L/M/N PG20-28

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal Summary Page

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

RGE 13 A T - 1 A

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

PAR5. Product Specifications

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

Product Data. Fig. 1 - Unit 50VG -A

62DA,DB,DC,DD,DE,DF07-38

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

High Heat COP. High/Low Stage

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

PRODUCT SPECIFICATIONS

WPH4 Product Specifications

Product Data. Fig. 1 - Unit 50EZ -A

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL SPECIFICATIONS

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Corp L2 Revised

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

SELF-CONTAINED AIR CONDITIONERS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

13 GEP A L P - 1 A

WALL-MOUNT HEAT PUMPS - (60HZ)

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

THE RIGHT SPEC. RIGHT NOW.

C13-Series Engineering Guide

PHD3. Product Specifications

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE


MERIT Series R-410A - Upflow / Horizontal

Commercial High-Efficiency Condensing Units

COMMERCIAL EQUIPMENT. Steam Humidifiers. Air Specialties Express 5-10 Pound Capacity Pound Capacity

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

VertiCool Aurora Engineering Guide

GREEN REFRIGERANT R-410A

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

MERIT Series R-410A - Upflow / Horizontal

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

4YCC3048A3096A /3/ /

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

SUNLINE BP 180 SUNLINE MAGNUM - BP 240

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Packaged Heat Pumps. Voyager 12½ to 20 Tons 60 Hz PKGP-PRC001-EN. September 2004

T CLASS ROOFTOP UNITS 60HZ Bulletin No July 2008 Supersedes August 2007

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Transcription:

DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressors Two-stage cooling Copper tube / aluminum fin coils Contactor with lugs High- and low-pressure switches High-capacity, steel-cased filter drier Heater kits with single-point entry 24-volt terminal strip Convertible Easy to service Built-in filter rack with standard 2 filters AHRI Certified; ETL Listed Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Condenser Hail Guards Full Perimeter Rail Sloped drain pan * Complete warranty details available from your local dealer or at www.daikincomfort.com. SS-DCC7 www.daikincomfort.com 11/13 Supersedes 7/13

Performance Data Cooling Performance Tota Capacity MBH Sensible Capacity MBH Outdoor Design TMP ºF DB / WB Air Temp entering Evaporator Coil ºF Power Input Required kw (less blower motor) Heating Performance Total Heating Capacity kw BTU/h Supply Air Blower Performance Total Supply Air Ext. Static Pressure Blower Speed Power Output Required Motor Ratings Power Input Required Electrical Data Power Supply Total Unit Amps Amps Max Overcurrent Device: Fuse Breaker Amps CFM IWG RPM BHP HP kw 2 www.daikincomfort.com SS-DCC7

Certified Dimensions Side View SS-DCC7 www.daikincomfort.com 3

Certified Dimensions Bottom View 4 www.daikincomfort.com SS-DCC7

Certified Dimensions End View SS-DCC7 www.daikincomfort.com 5

Accessories List (Detailed specifications begin on the following page.) Filed-Installed Item # Description Fits Model Sizes Field- Installed 14CURB90150 14" Roof Curb 7½-12½ tons D25MFD90150 25% Manual Fresh Air Damper 7½-12½ tons D25MFD90150 25% Motorized Fresh Air Damper 7½-12½ tons DBRD3672 Barometric Relief Damper (2 required) 7½-12½ tons DDNBBS90150 Burglar Bar Sleeves: includes Supply & Return 7½-12½ tons CDK120 Concentric Duct Kit 10 tons CDK150 Concentric Duct Kit 12½ tons CDK90102 Concentric Duct Kit 7½-8½ tons HailGD02D Condenser Coil Hail Guard 7½-10 tons HailGD05D Condenser Coil Hail Guard 12½ tons Factory- Installed Convenience Outlet: Powered All Models Convenience Outlet: Non Powered All Models Disconnect Switch (non-fused) All Models DDNECNJ90150 Downflow Economizer 7½-12½ tons DDNSQRD9020 Downflow Square-to-Round Adapter 20" Round 7½ tons Electric Heat Kits All Models HSKT090¹ High-Static Kit (230/460v) 7½ tons HSKT090G¹ High-Static Kit (230/460v) 8½ tons HSKT120¹ High-Static Kit (230/460v) 10 tons HSKT150¹ High-Static Kit (230/460v) 12½ tons HSKT090-7¹ High-Static Kit (575v) 7½ tons HSKT090G-7¹ High-Static Kit (575v) 8½ tons HSKT120-7¹ High-Static Kit (575v) 10 tons HSKT150-7¹ High-Static Kit (575v) 12½ tons DHZECNJ90150 Horizontal Economizer 7½-12½ tons GHRC-1 Hurricane Restraint Clips All Models LAKT03 Low-Ambient Kit 7½ - 12½ tons DPE901502 Power Exhaust (208/230v) 7½-12½ tons DPE901504 Power Exhaust (460v) 7½-12½ tons DPE901507 Power Exhaust (575v) 7½-12½ tons IP90150 Roof Curb Insulated Panels 7½-12½ tons Smoke Detector All Models ¹ HSKT High-Static Kits are for use with standard single-speed belt-drive units only. 6 www.daikincomfort.com SS-DCC7

Roof Curb #14CRB90150 Specifications 18-Gauge Construction 1 x 4 Wood Nailer attached to top of the curb Shipped knocked down with all hardware Gasket included Bed-Rail style corners Note: outside duct dimension should be ½ less than opening dimensions above. No Curb Adapter Required when Replacing Carrier & Bryant Models No curb adapter is required when replacing an existing Carrier or Bryant RTU with a Goodman RTU in the following situations. The footprints and locations of the return and supply ductwork match. New Unit Existing Carrier Existing Bryant 7½ to 12½ Tons CPC, CPG, CPH 48/50 TJ, LJ, DJ, QJ 48/50TM, HJ 008-014 580C-D, 558C-D, 548C-D 580F, 558F, 581B 090-150 7½-Ton Square-to-Round #DNSQRRND90 SS-DCC7 www.daikincomfort.com 7

Manual Fresh Air Damper #D25MFD90150 Motorized Fresh Air Damper #D25MFD90150 Specifications Manual Damper Provides up to 25% fresh air Locking selection knob provides constant opening Painted to match the unit Fits all 7½- to 12½-ton package units in all fuels Motorized Damper 24 VAC Damper motor with spring return Fully assembled and factory wired Painted to match the unit Fits all 7½- to 12½-ton package units in all fuels 8 www.daikincomfort.com SS-DCC7

Downflow Economizer #DDNECNJ90150 6 11 42½ 18⅓ Specifications Fully modulating Up to 100% fresh air Integral barometric relief Hoods painted to match unit Honeywell economizer control Single adjustable enthalpy control convertible to dual enthalpy Adjustable minimum fresh air Factory wired Fits all 7½- to 12½-ton units SS-DCC7 www.daikincomfort.com 9

Horizontal Economizer #DHZECNJ90150 Specifications Fully modulating Up to 100% fresh air Honeywell economizer control Single adjustable enthalpy control convertible to dual enthalpy Adjustable minimum fresh air Factory wired Fits all 7½- to 12½-ton units 10 www.daikincomfort.com SS-DCC7

Barometric Relief Damper #DBRD3672 Power Exhaust for 208/230v Units #PE901502 Power Exhaust for 460v Units # PE901504 SS-DCC7 www.daikincomfort.com 11

Concentric Duct Kit #CDK90102 / #CDK120 / #CDK150 Light Commercial T-Bar Ceiling Commercial T-Bar Ceiling Hanging Support from the Diffuser Turing Vane to Ensure Proper Airflow Aluminum Egg Crate Molded Fiberglass Transition Specifications All-aluminum diffuser with aluminum return air egg crate Built-in anti-sweat gasket Molded fiberglass transition (through five tons) Built-in hanging supports Diffuser box constructed of fiberglass duct board (through 7½ tons) or sheet metal Our continuing commitment to quality products may mean a change in specifications without notice. 2013 Houston, Texas Printed in the USA. 12 www.daikincomfort.com SS-DCC7