Product Data VA3B VB5B VC5B. Heat Recovery Ventilators

Similar documents
MODELS VA3B, VB5B VC5B

Product Data HRVCCLHU HRVCCSVC HRVCCLVU. Heat Recovery Ventilators FEATURES

HRVBBLHU HRVBBSVC HRVBBLVU

Product Data. ERVCCSVA, ERVCCSHA Energy Recovery Ventilators STANDARD FEATURES ERVCCSVA ERVCCSHA

Product Data. HRVCCSVU, HRVCCLVU Single---Package Electric Heating Cooling Units Heat Recovery Ventilators

Product Data ERVC. Energy Recovery Ventilators. Features

Product Data HRVBBLHA, HRVBBSVA, HRVBBSHA HEAT RECOVERY VENTILATORS STANDARD FEATURES HRVBBLHA HRVBBSVA HRVBBSHA

Product Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators

Product Data HRV A10299

ERVB ENERGY RECOVERY VENTILATORS. Form No. PDS ERV.64.1

Product Data A05229 A05330 HRV

Product Data. ERVCCLHA Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Product Data MECH. Mechanical Filter Air Cleaner

Indoor Air Quality Product Brochure.

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

HEAT RECOVERY VENTILATOR

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Indoor Air Quality Product Brochure.

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

ENERGY RECOVERY VENTILATOR

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

10-year industry best core warranty. 5-year warranty on balance of unit.

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Installation Information

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Installation, Start-Up, and Operating Instructions Sizes 1150, 1200, 1250, and 1330

Heat Recovery Ventilators models:

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

Outside Air Requirements... SOLVED!

Product Data. FH4A Fan Unit. Sizes 001 thru 004

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Put the V back in HVAC

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

For Models Superventor Series

READ AND SAVE THESE INSTRUCTIONS

Ventilation Solutions IAQ Canada

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

IAQ VENTILATION SOLUTIONS

TR Series - The Ultimate ERV

Product Catalog Commercial Solutions US Edition

Product Catalog Commercial Solutions US Edition

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

IAQ VENTILATION SOLUTIONS

The best way to enhance indoor air quality

GLOBAL FINISHING SOLUTIONS

installation, start-up, and operating instructions

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Total Recovery for ALL Climates Models TR & TRC

Heat Recovery Ventilation Systems OWNER S GUIDE

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Ventilation Solutions IAQ Canada

TECHNICAL SPECIFICATIONS

62DA,DB,DC,DD,DE,DF07-38

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

1 Ventilation Checklist 1 Forced Air Systems SENTENCE (6)

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. HUM Humidifiers

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

Residential Heat & Energy Recovery

HOME OWNERS GUIDE ERV MODEL PE 7.15 PE SS Product of Imperial Air Technologies

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Installation, Operation, and Troubleshooting Instructions

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

VERTICAL FAN COIL UNITS

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

INSTALLATION INSTRUCTION & OWNER S GUIDE

INSTALLATION AND OPERATION INSTRUCTIONS

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Heat or Energy Recovery Ventilation System

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

Energy Recovery with Cooling and Heating Model ERCH

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

BETTER AIR. BETTER LIFE.

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

Transcription:

Product Data VA3B VB5B VC5B Heat Recovery Ventilators VA3B VC5B The Heat Recovery Ventilation (HRV) system offered by Carrier is the finest unit on the market today. The VA3B, VB5B, and VC5B provide efficient and cost-effective heat recovery during the heating season when needed most. As temperatures drop below 23 F ( 5 C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming. Competitors methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix air streams, these cross-flow or counter-flow heat exchangers ensure that there is no mixing of the stale air stream with the fresh outdoor air stream. A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required. The units acoustically engineered design makes them the quietest on the market and ensures that comfort is felt, not heard. Unlatching 2 suitcase style latches allows easy removal of the filters and core for cleaning. VB5B Copyright 1995 Carrier Corporation This document was created with FrameMaker 4.0.4 Form VA3B-1PD

Features Energy saving defrost cycle Cross-flow, counter-flow heat exchangers Two filters on incoming outdoor air stream to protect the HRV core Acoustical design No-tools maintenance Model number nomenclature V A 3 B A B 015 A 115-1-60 B Second Series 3 Horizontal 5 Upflow/Downflow A Conventional (RNC) B Compact (Standard) C High Efficiency (Deluxe) V Heat Recovery Ventilator B Defrost Maximum Capacity (cfm) 015 (150 cfm) 020 (200 cfm) 027 (270 cfm) TESTED/CERTIFIED AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY HOME VENTILATING INSTITUTE DIVISION OF AMCA 2

Controls and accessories part no. nomenclature K V B CN 01 01 CAU K Accessory Kit 01 Part Number AC Accessory CN Control FL Filter Media TM Timer A Original Series B Second Series V Heat Recovery Ventilator (HRV) CONTROL DESCRIPTION (B SERIES) CAU Carrier Automatic Control CBS Carrier Basic Control CST Carrier Standard Control ACCESSORY DESCRIPTION (A SERIES) 6FM 6 in. Flowmeters (2) 7FM 7 in. Flowmeters (2) 8FM 8 in. Flowmeters (2) EXH Exhaust Hood HOD Intake Hood KIT Balancing Kit FIR Furnace Interlock Relay (A SERIES) TIMER DESCRIPTION 2OM 20-Minute Timer Kit Non Branded (B SERIES) 2OC 20-Minute Timer Kit Carrier (A SERIES) 60M 60 Minute Adjustable Timer Kit (A SERIES) FILTER DESCRIPTION ( A SERIES) 112 11-1/2 x 12-3/4 116 11-7/8 x 16-5/8 123 12-15/16 x 13-1/2 145 14-3/8 x 15-1/2 713 7-13/16 x 13-1/2 810 8-1/8 x 10-3/4 812 8-7/8 x 12-3/4 916 9 x 16-5/8 01 Single Pack 3

Dimensions 23 1 2 (596.9) 7 1 2 DIA (191.0) G 4 3 4 (120.6) 5 7 8 DIA (148.9) 1 (25.4) 2 15 16 (74.6) 2 3 16 (56.2) 4 PLCS 11 16 (17.5) 5 7 8 DIA (148.9) 2 5 16 (58.7) 2 7 16 (61.9) K 5 7 8 DIA (148.9) 7 1 2 DIA (191.0) F 16 3 4 (425.4) 20 (508.0) 18 1 8 (460.4) 16 7 8 (428.6) 15 (381.0) E 5 7 8 (148.9) 30 1 4 D C B A 5 16 (7.9) 3 8 (9.5) H (768.3) 1 1 16 (27.0) 11 16 (17.5) 1 2 (11.9) 1 5 8 (41.3) 7 8 (22.2) 1 1 4 (31.7) J 3 4 (19.0) 3 8 DIA (9.5) A92274 A B C D E F G H J K MODEL NO. in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm VA3BAB015 15-3/16 385.8 14-3/4 374.6 12-7/8 327.0 4-3/4 120.6 5-1/8 130.2 14-3/4 374.6 7-5/8 193.6 20-3/8 517.5 7-5/16 185.7 7-3/4 196.8 VA3BAB020 18-7/8 479.4 18-5/8 473.1 16-5/16 414.3 13-1/2 342.9 5-7/8 149.2 14 355.6 10 254.0 15-13/16 401.6 9-5/16 236.6 8-13/16 223.8 4

Dimensions continued 4 9 16 [115.9)] 7 1 2 DIA [191.0] 5 7 8 DIA [148.9] H DIA 3 4 [19.0] 7 16 DIA [11.2] 7 8 DIA [22.2] 3 8 DIA [22.2] E 3 3 16 [80.2] D 2 15 16 [74.6] 5 3 4 [146.0] 1 [25.4] F 19 3 4 [500.8] 1 15 16 [48.4] 2 3 16 [56.2] 4 PLACES 2 7 16 [61.9] 2 PLACES 4 3 16 [105.6] 21 3 4 [553.2] 27 [658.8] 20 1 2 [521.3] C A B 2 3 16 [56.4] 3 8 [9.5] 21 [533.4] 15 11 16 [397.7] 11 16 [16.7] 11 16 DIA. [17.5] 2 5 8 [66.7] 3 4 [19.1] G A92275 MODEL NO. A B C D E F G H in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm VB5BAB015 18-3/8 466.7 18-3/8 466.7 16-9/16 420.7 4-11/16 119.1 13-5/16 388.2 15-7/16 392.1 13-9/16 344.5 5-11/16 144.5 VB5BAB020 VC5BAB015 24-1/4 615.9 24-1/2 622.2 22-3/16 563.5 8-3/16 208.0 19-5/16 490.6 14-9/16 369.2 16-15/16 429.4 6-15/16 176.2 5

Dimensions continued 8 1 8 DIA [206.4] 7 1 2 DIA (191.0) 5 7 8 DIA [148.9] 2 15 16 [74.6] 3 PLCS 37 [940.6] 43 3 4 (1085.9) 19 15 16 [505.6] 2 3 4 [70.7) ]3 4 [19.1] 3 8 [9.5] 19 1 16 [484.7] 8 3 16 [208.5] 17 9 16 [445.4] 5 13 16 [147.8] 4 3 4 [120.6] 15 1 2 [394.5] 18 5 16 [464.4] 1 [25.4] 6 15 16 [175.9] 2 3 16 [55.5] 2 7 16 [61.9] 3 PLCS 36 13 16 [935.0] 19 15 16 [506.4] 11 1 8 [282.6] 23 1 8 [587.4] 11 16 [16.7] 3 1 16 [77.8] 11 16 DIA. [17.5] 7 3 16 [181.8] VC5BAB020 VC5BAB027 23 13 16 [604.3] 22 3 8 [568.3] 1 1 8 [29.3] 7 1 8 [181.0] 40 3 4 [1035.1] 7 8 DIA. [22.2] 3 4 [19.1] A92276 6 1 1 2 [38.1] 21 3 4 [551.9] 24 1 16 [610.6]

Physical data MODEL DESCRIPTION CONVENTIONAL COMPACT HIGH EFFICIENCY Model No. VA3BAB015 VA3BAB020 VB5BAB015 VB5BAB020 VC5BAB015 VC5BAB020 VC5BAB027 Capacity - cfm l/s 65 150 30 70 115 200 55 95 65 127 30 60 115 195 55 92 65 127 30 60 115 180 55 85 Port Locations Top and Sides Top and Sides Top Top Top Top Top 180 265 85 125 Heat Core Type Cross Cross Cross Cross Cross Counter Counter Weight Shipping Weight Shipping Dim. (in.) Height Width Depth 60 lb (27 kg) 67 lb (30.4 kg) 21.00 35.5 19.75 80 lb (36.6 kg) 85 lb (38.5 kg) 21.00 35.5 19.75 60 lb (27 kg) 75 lb (34 kg) 31.5 23.25 26.00 80 lb (36.3 kg) 89 lb (40.4 kg) 31.5 23.25 26.00 80 lb (36.3 kg) 89 lb (40.4 kg) 31.5 23.25 26.00 120 lb (54.5 kg) 143 lb (64.9 kg) 47.5 26.0 26.0 120 lb (54.5 kg) 143 lb (64.9 kg) 47.5 26.0 26.0 Performance data MODEL DESCRIPTION CONVENTIONAL COMPACT HIGH EFFICIENCY Model No. VA3BAB015 VA3BAB020 VB5BAB015 VB5BAB020 VC5BAB015 VC5BAB020 VC5BAB027 Capacity - cfm l/s Efficiency 32 F (0 C) 13 F ( 25 C) Heat Core Exchange Area 65 150 30 70 76% 56% 115 200 55 95 68% 61% NOTE: Consult design manual for proper selection of unit. 65 127 30 60 69% 60% 115 195 55 92 77% 67% 65 127 30 60 84% 66% 115 180 55 85 84% 72% 180 265 85 125 120 ft 2 160 ft 2 90 ft 2 144 ft 2 144 ft 2 210 ft 2 210 ft 2 11.2 m 2 14.9 m 2 8.4 m 2 13.3 m 2 13.3 m 2 19.5 m 2 19.5 m 2 80% 74% 7

Accessory description and usage Push Button Timer Enables the unit to override mode selected and operate at high speed for 20 minutes. Ideal for special activity areas such as bathrooms or kitchens where high-speed exhaust is needed for short periods of time. Kit includes 12 wall-mounted timers and a control unit (12v). 60-Minute Timer Allows the user to override current operation mode and operate at high speed. Adjustable from 10 to 60 minutes with an additional 20 minutes added from the control board. Ideal for areas requiring high-speed exhaust for longer periods of time (12v). Balancing Kit Installers tool complete with: 1 Magnahelix gage (0 2.5 in. H[in 2 ]O), 2 6-in. diameter flowmeters, 4 pieces of plastic hose and instructions. Packaged in a metal tool box, this kit contains all the instruments needed to balance an HRV installation. Control features Basic Control: Allows the user to manually set fan speed to low or high as required to maximize comfort. Standard Control: Offers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the wall control to low will activate the continuous mode. Automatic Control: In addition to the features found with standard control, this package offers a recirculation mode and an air ionizer. These controls may only be used to operate stand-alone units with the defrost option which enables the recirculation feature. CONTROL DESCRIPTION FAN SPEED CONTROL * Air exchange with outside. No air exchange with outside. DEHUMIDISTAT CONTROL CONTINUOUS MODE* INTERMITTENT MODE* CIRCULATION MODE Basic Yes No Yes No No No Standard Yes Yes Yes Yes No No Automatic Yes Yes Yes Yes Yes Yes AIR IONIZER Control description and usage Fan Speed Control Enables user to modulate fan speed from low to high air exchange with outside. Dehumidistat Control Allows the user to select the relative humidity level at which the unit would change fan speed for dehumidification in the winter months. Continuous Mode If the relative humidity inside the building is lower than selected, air exchange occurs with the outside at low speed. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures continuous air exchange for constant air quality. Intermittent Mode If the relative humidity inside the building is lower than selected, no air exchange occurs and the system turns off. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures minimum air exchange level when the building is unoccupied to minimize operating costs. Circulation Mode If the relative humidity inside the building is lower than selected, the ambient air would be circulated and filtered at high speed. If the relative humidity inside the house is higher than selected, air exchange would occur with the outside at high speed. Ensures continuous movement and filtration of air for maximum comfort. Available with automatic control only. Air Ionizer Neutralizes airborne particulates by negatively charging them. For use on independently installed systems. 8

Automatic defrost cycle features All models offer a non-electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core. When the outside air temperature falls below 23 F/ 5 C it is electronically sensed and the dampers close the outside air ports. This allows warm indoor air to recirculate within the heat recovery core. The frequency of this cycle increases as the outside air temperature decreases. MODEL PREFIX 23 F TO 5 F ( 5 C TO 15 C) 5 F TO 22 F ( 15 C TO 30 C) BELOW 22 F ( 30 C) DEFROST EXCHANGE DEFROST EXCHANGE DEFROST EXCHANGE VA3BAB 5 Minutes 60 Minutes 5 Minutes 35 Minutes 5 Minutes 20 Minutes VB5BAB 5 Minutes 60 Minutes 5 Minutes 30 Minutes 5 Minutes 20 Minutes VC5BAB 6 Minutes 60 Minutes 6 Minutes 35 Minutes 6 Minutes 20 Minutes Electrical data CONVENTIONAL COMPACT HIGH EFFICIENCY Model VA3BAB015 VA3BAB020 VB5BAB015 VB5BAB020 VC5BAB015 VC5BAB020 VC5BAB027 Voltage 120v 120v 120v 120v 120v 120v 120v Max Power 105w 216w 115w 196w 120w 250w 520w Max Amps 1.2a 2.0a 1.2a 1.8a 1.2a 2.5a 4.6a 9

HRV installed with forced air system A92361 HRV installed with independent air distribution A92360 Copyright 1994 Carrier Corporation Syracuse, New York 13221 2-95 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 10 Catalog No. 92-32VA-3B1C Printed in U.S.A. PC 101 Form VA3B-1PD Tab 10a 12a Replaces:VA3A-1PD