IDETECH R NE IDETECH SERVICE MANUAL PORTABLE AIR CONDITIONER PAC-0000DB Important points on service, and flow chart for inspecting and repairing the unit... Appearance(out ward)... Troubleshooting... 3 Functions and control panel... 4 Technical specifications... 5-6 Refrigerator system diagram and schematic wiring diagram... 7 Exploded view... 8 Parts list... 9 - This manual is for the use of technical personnel entrusted with maintenance. idetech reserves the right to change this dehumidifier's casing, circuit and parts without notice. 0-40V 50Hz
IMPORTANT POINTS ON SERVICE OPERATING SAFETY Please follow these instructions carefully: Unplug the unit to avoid any danger from electric shock before disassembling the unit for repair. If there is any sound of the refrigerant circulating when in operation, avoid touching the cooling coils. If you need to perform any welding or soldering, be sure you are in a well ventilated area. Only a qualified professional should perform any welding on the unit. hen repairing the unit, the specifications listed in this manual must be strictly adhered to when replacing any components. hen replacing any electrical components they should be factory approved units. Be sure that any electrical components are properly wired and in place. FLO CHART FOR INSPECTING AND REPAIRING THE UNIT AIR CONDITIONER ON'T START NO TRIPPED CHECK THE SITCH PLUG AND SOCKET ARE LOOSE RE-PLUGING THE SUPPLY CORD TIMER FAILURE TESTING BY ELECTROSCOPE CHANGE THE SITCH AIR CONDITIONER ON'T COOL PROPERLY COMPRESSOR ON'T START PROTECTOR FAILURE CHANGE THE PROTECTOR CAPACITOR FAILURE CHANGE THE CAPACITOR IRING IS LOOSE RE-CONNECTING REFRIGERANT LEAKAGE TROUBLE SHOOTING THE SYSTEM CHANGE THE AIR CONDITIONER ITH 5KG/CM NITROGEN GAS FROM LO-PRESSURE SIDE AND DETECT THE LEAKING POINT BY SOAP USE OXYACETYLENE AND PLUS 5% SILVER SOLDER TO ELD THE CRACKED POINTS RUNNING THE VACUUM EVACUATION FOR MORE THAN 5 MINUTES CHANGE COOLANT AND PROCEED RUNNING TEST RUNNING TEST
APPEARANCE(OUT ARD) control panel FRONT SIDE Air outlet Handle hole Front panel Caster APPEARANCE(OUT ARD) AIR FILTER BACK SIDE REAR COVER ACCESSORIES HEAT EXHAUST HOSE CONNECTOR FIX TURE FIX TURE DISCHARGE GRILLE (COMPLETE) FIX TURE DRAINAGE PIPE SUPPLY CORD CAP
TROUBLESHOOTING PROBLEM POSSIBLE CAUSE REMEDIES The air conditioner doesn't work -There is a power failure -The plug is not connected -The timer is unable to work -The main switch has not been pressed -ait for the power return -Connect the plug -Provide repairment -Press the main switch The air conditioner works for short period only -The set temperature is too close to the room's temperature -There is something blocking the suction vent on the back of condenser -The fan on the condenser is blocked -Decrease the setting temperature -Remove any obstacles -Provide repairment The air conditioner switches are off constantly -Malfunction -Turn off the appliance remove the plug and contact the service center The air conditioner works but it does not cool the room -There is a window opened -There is a source of heat operating in the room (burner, lamp, etc.), or the room is crowded -The air filter is clogged -The capacity of the air conditioner is not suitable for the conditions or size of the room -The evaporator is frozen -Close the window -Remove/switch off the source of heat -Decrease the set temperature -Clean the filter -Clean the air filter -Change the purifier filter, if necessary -Do not make the appliance operating at too low temperature(below The appliance is very noisy and vibrates violently -The compressor blocking device has been loosen or the copper pipe is getting in touch with the body of the set -Provide repairment 3
Operation of PAC-0000DB(0000 B.T.U.) Easy operation NAME OF THE PARTS Full-Tank Indicator See the troubleshooting when the lamp is on. Set-up of Function key : lamp is on when in cooling mode : lamp is on when in dehumidification mode : lamp is on when in fan mode Temperature & Timer set-up key. Time on or Time off mode: Timer setting.(- Hours). Cooling or Dehumidification mode: Temperature setting.(6~3 ) C 3 4 Power Key On / Off Fan Speed Key :HIGH :MED :LO On / Off Timer Key In running mode : Auto switch off In standby mode: Auto switch on Operation Symbols Operation procedure Air conditioning. Make sure power cord is properly connected. (Standby). Press " On / Off " key. 3. Setup function key to " air conditioning " if necessary. 4. Select proper fan speed by actual situation if necessary. Fan mode. Make sure power cord is properly connected. (Standby). Press " On / Off " key. 3. Setup function key to " Fan " 4. Select proper fan speed by actual situation. Operation procedure for auto switch on/off A. Auto switch off ) To be operated in cooling or fan mode. ) Press " Auto on / off " key for machine's stopping operation after,,3,..., hours. B. Auto switch on ) Be sure that machine is in standby mode. ( power cord is securely plugged ) ) Press " Auto on / off " key for machine's starting operation after,,3,..., hours. 4
TECHNICAL SPECIFICATIONS AIR CONDITIONER ITEM OUTER DIMENSION REFERENTIAL USING AREA RATED VOLTAGE RUNNING VOLTAGE COOLING CAPACITY DEHUMIDIFYING CAPACITY RUNNING CURRENT CONSUMPTION INDOOR AIR VOLUME INPUT OPERATING COMPRESSOR CYCLE INDOOR MOTOR OUTDOOR MOTOR TURBINE FAN MOTOR CAPILLARY EVAPORATOR CONDENSER PROTECTOR LOCKED ROTOR AMPS OUTPUT OPERATING CYCLE OUTPUT OPERATING CYCLE OUTPUT REFRIGERANT APPLICABLE AMBIENT TEMPERATURE EIGHT UNIT mm m V/Hz V B.T.U. L/H A 3 m/hr uf/v A uf/v uf/v mm R/g Kg PAC-0000DB 54*897H*347D 3 9 0~40/50 98 64 0000.8 4.7 035 40 KETC54ELBABA 950~975 5/450 MRA9055-9079 6.5 TC-3G 30 /400 TC-43G 43.5/450 A90S.6(O.D.)*.4(I.D.)*950(L) RS7FPI R3S6FPI 440 8 35 3 5
TECHNICAL SPECIFICATIONS AIR CONDITIONER ITEM UNIT PAC-0000DB AIR CONDITIONER OUTER DIMENSION REFERENTIAL USING AREA mm m 460*780H*30D 3 9 RATED VOLTAGE V/Hz 0~40/50 RUNNING VOLTAGE V 07 53 COOLING CAPACITY B.T.U. 9000 DEHUMIDIFYING CAPACITY L/H.6 RUNNING CURRENT A 5.0 CONSUMPTION 900 INDOOR AIR VOLUME 3 m/hr 30 INPUT OPERATING COMPRESSOR CYCLE uf/v NK34PLC 738/76 5/370 PROTECTOR MRA0-06 LOCKED ROTOR AMPS A 9 INDOOR MOTOR OUTPUT OPERATING CYCLE uf/v TC-3G 30 /400 OUTDOOR MOTOR OUTPUT OPERATING CYCLE uf/v TC-43G 43.5/450 A90S TURBINE FAN MOTOR OUTPUT CAPILLARY mm.6(o.d.)*.4(i.d.)*600(l) EVAPORATOR RS7FPI CONDENSER REFRIGERANT APPLICABLE AMBIENT TEMPERATURE EIGHT R407c/g Kg R3S6FPI 440 8 35 3 6
REFRIGERATOR SYSTEM DIAGRAM INDOOR RADIATOR DRUM INDOOR MOTOR INDOOR RADIATOR FAN EVAPORATOR OUTDOOR RADIATOR DRUM OUTDOOR RADIATOR FAN OUTDOOR MOTOR LIQUID ACCUMULATOR COMPRESSOR CAPILLARY CONDENSOR AIR FILTER ATER PADDIE ATER MOTOR SCHEMATIC IRING DIAGRAM PAC-0000DB T0(NATURE) 7
63 49 4 37 36 35 30 59 8 7 3 34 4 46 38 9 3 0 6 9 5 4 5 7 3 4 3 4 6 5 7 3 53 5 55 33 56 6 60 47 4 6 ACCESSOR 0 40 5 4 69 EXPLODED VIE PAC-0000DB 6 57 58 64 68 67 44 45 65 66 43 70 7 74 7 75 73 39 48 54 8 9 8 50 OPTION 8
PARTS LIST NO 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 30 3 3 33 34 35 MATERIAL CODE PARTS NAME QUANTITY A480-00 A740-00 A540-00-A- A5408-00-H- A540-00-A- A5404-00 A506-00 V0P-00 A7307-00 A500-070-A- A3000-430 A53-030-A- A580-40 A30-080 A3404-40 A3408-00 A60-00 A608-390 A67-50 A580-070 A580-080 A3000-360 A530-070-A- A530-090-A- A5304-050-A- A509-30 A5700-00 A500-0-P- A55-00 A3400-30 A604-0 A580-030 A580-040 A3000-330 A530-0-A- BASE PAN ASS'Y TURING HEEL DRAIN BUCKET DRAIN BUCKET COVER RENK FLOAT MICRO SITCH DRAINAGE PIPE SOFT CAP DRAINAGE PAN FAN MOTOR BLADE COMPRESSOR ASS'Y CONDENSER STRAINER COMPLETE SERVICE TUBE DISCHARGE PIPE SUCTION PIPE FAN MOTOR FAN CASING FAN CASING BLOER HEEL CAPACITOR PLATE DRAINAGE PAN TERMINAL BLOCK EVAPORATOR CAPILLARY TUBE FAN MOTOR FAN CASING 9 PRICE
PARTS LIST NO 36 37 38 39 40 4 4 43 44 45 46 47 48 49 50 5 5 53 54 55 56 57 58 59 60 6 6 63 64 65 66 67 68 69 70 MATERIAL CODE PARTS NAME QUANTITY PRICE A530-30-A- A5304-070-A- A509-060 A55-00 A5900-00 A580-00 A580-00 A454-50-A-BS A693-90-Z A50-0 A56-60 A3700-00 A509-080 A5700-00 A4-30-A-BS A4-50-A-BS A438-090-A-BS A40-30-A-BS A60-050-A-BS A60-070-A-BS A5805-030-A-BS A49-30-A-BS A730-070-A-BS A735-00-A-BS A60-090-A-BS A740-030 A406-0-A-BS A600-00 A58-00-H-BS A5700-00 A5700-0 A585-050-A-BS A60-00-H-BS A59-080 A700-090 FAN CASING BLOER HEEL CAPACITOR TERMINAL BLOCK TOP BOARD CONTROL PLATE CONTROL PANEL PC BOARD CONTROL BOARD SUPPLY CORD COMPLETE CAPACITOR PLATE SIDE PLATE SIDE PLATE DISCHARGE GRILLE FRONT PANEL SCRE TOP COVER SCRE TOP COVER FIX TURE REAR COVER AIR FILTER FILTER FRAME CAP TURING HEEL TOP COVER PLATE HEAT EXHAUST HOSE CONNECTOR FIX TURE PLATE PLATE FIX TURE CAP REMOTE CONTROL CARTON 0
PARTS LIST NO 7 7 73 74 75 MATERIAL CODE PARTS NAME QUANTITY PRICE A70-580 A707-50 A707-60 A707-70 A705-0 CARTON SHOCK ABSORBER SHOCK ABSORBER SCRE TOP COVER CARTON BASE