CII FCAC-150 Series Relay

Similar documents
RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

KILOVAC K1K High-Voltage Contactor

Introducing Hermaphroditic Blade and Receptacle Connector

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Introducing SlimSeal SSL Connector

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Introducing Low Voltage DC Grid Interconnects

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

QUADRAX D-SUB CONNECTORS

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

Jun08 Rev C

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

VAMP 120 & 121. Arc flash detection units. Product picture

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Mar11 Rev C

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

Introducing Solar Identification Labels

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

5BT SERIES -65 F to 400 F, SPDT, Welded, Hermetically Sealed ½

Model Number Structure

Quick Reference Guide Barrier Strips

PCB Relays Single Relays

Schneider Electric Erie T155 Series

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

SWK1323AL101 H2 Keylock

TEMPERATURE CONTROLLER

CR Series Command Relays

Table of Contents. Protective Relays

Ultrasonic Reflective Sensor

DGC-500 DIGITAL GENSET CONTROLLER

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

Introducing Corcom CU Series 1U Height Power Entry Modules

MICRO SWITCH Sealed and High Accuracy Switch Line Guide

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Mar11 Rev B

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

DGC-1000 DIGITAL GENSET CONTROLLER

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Ultrasonic Proximity Sensor

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Ultrasonic Reflective Sensor

DP86 Constant Voltage with Fitting

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

M7100 Pressure Transducer

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

DTA. Motor thermistor relay. Benefits. Description

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

M5200 Industrial Pressure Transducer

Plug-in Base, Long Range Sensor E3B2

Temperature Controllers

Standard SPECIFICATIONS FEATURES APPLICATIONS

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

D5100 Industrial Differential Pressure Transducer

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

MARC70 Installation Manual

C6097A,B Pressure Switches

D5100 Industrial Differential Pressure Transducer

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Mors Smitt Industrial Technology. Substation Protection & Control. High Performance Electromechanical Relays. RMS Mors Smitt A Wabtec company

Specification/ Data Sheet

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

LC1350 Level Controller

HARTMAN Smart AC Contactors

SolderSleeve Insulated Electrical Termination Devices

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

.025 Connector Series

Proximity Sensors Line Guide

Ultrasonic Proximity Sensor

E3M-V. Mark Sensor. Applications

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

Series Temperature Controller Instruction Sheet

M2500 Engine Controller Installation Manual

High Pressure Conductivity Monitor

7EF/7HF/7EC/7ES Temperature Controllers

Bulletin 1608N MiniDySC Dynamic Sag Corrector

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Analog Room Pressure Monitor RPC Series

Transcription:

Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

KEY FEATURES Non-latching relay Balanced force design Corrosion protected metal enclosure All welded hermetically sealed enclosure occupies about 1 in 3 1 Form X (SPST-NO-DM) Auxiliary versions available with 1 Form C (SPDT) aux. 6, and 28 Vdc coils available Weight: 90 grams Designed and built in accordance with MIL-PRF-6106 Rated for altitude up to 300,000 ft. Available with optional terminals and mounting styles DESCRIPTION The series relay is a polarized, single-side stable design, where the flux from a permanent magnet provides the armature holding force in the deactivated state, and its flux path is switched and combined with the coil flux in the operated state. This results in appreciably increased contact pressure in both states over that of a spring return non-polar design. The series has a 1 Form C (SPDT) auxiliary contact set rated at 2 Amps available. Designed and built to perform under the most demanding environmental conditions and can withstand such changing environmental factors as temperature, altitude, shock, vibration, and salt spray. Minimum mechanical life expectancy is 50,000 cycles under resistive load. 3 available coil voltages (6, and 28 Vdc) with optional transient suppression. APPLICATIONS Used in military, aerospace, and associated ground support electrical and electronic systems. Principle areas of application include: - Aircraft - Missiles - Power Distribution - Fuel Pumps Avionics Main Power Feed Weapons Systems - Ground Support Equipment PART NUMBERING SYSTEM Typical Part Number or -A Y 3 Series and Contact Arrangement: = Relay with 1 Form X Main Contacts = Relay with 1 Form X Main Contacts and 1 Form C Auxiliary Contacts Terminals (see drawings for details): B = Solder Pin Coil Terminals, Stud Power Terminals C = Solder Hook Coil Terminals, Stud Power Terminals K = Terminal Block, Stud Power Terminals Enclosure (see drawings for details): R = Horizontal Flange Mount, Rotated U = Flush Vertical Flange Mount X = Horizontal Flange Mount Y = Raised Vertical Flange Mount Z = No Mount Coil: 1 = 6Vdc nominal 2 = Vdc nominal 3 = 28Vdc nominal 4 = 28Vdc nominal, with back EMF suppression Tyco Electronics I &

PERFORMANCE DATA Specifications Contact Data Contact Form : 1 Form X (SPST-NO-DM) : 1Form X (SPST-NO-DM) with 1 Form C (SPDT) Auxiliary Contacts Contact Rating in Amps (Continuous Duty) Type of Life (Min.) 5 Vac Load Cycles 28 Vdc 400Hz Resistive 50,000 50 50 Inductive (L/R=5ms) 20,000 20 20 Motor 20,000 20 20 None 100,000 Overload Current (Resistive) Max. Contact Drop at 10A Operate Time at Nominal Voltage Release Time Bounce Time Coil Data 200 A, 50 cycles Initial 150mV; After Life 175mV 15ms 15ms 1ms Coil Code 1 2 3 4 Nominal Operating Voltage (Vdc) 6 28 28 Maximum Operating Voltage (Vdc) 7.3 14.5 29 29 Maximum Pick-Up Voltage at +5 C 4.5 9 18 18 Maximum Pick-Up Voltage at +5 C, continuous current test (Vdc) 5.7.25 22.5 22.5 Drop-Out Voltage at +5 C 0.3 2.5 0.75 4.5 1.5 7.0 1.5 7.0 Maximum Coil Current at +25 C (ma).50.26.15.15 Back EMF Suppressed to (Vdc) N/A N/A N/A -42 Coil Resistance 18Ω 70Ω 290Ω 290Ω Electrical Data Initial Insulation Resistance (note 1) Insulation Resistance After Life or Environmental Test (note 1) 100 megohms, minimum, at 500Vdc, between each pin and case 50 megohms, minimum, at 500Vdc, between each pin and case Dielectric Strength At Sea Level Contacts to Ground and Between Contacts Coil to Ground Dielectric Strength at 80,000 ft (25,000m), All Points (note 4) Environmental Data Ambient Temperature Range, Operating Altitude Shock Resistance Vibration Resistance, Sinusoidal Mechanical Data Approximate Weight 1,250Vrms, 60 Hz. 1,000Vrms, 60 Hz. 500Vrms, 60 Hz -70 C to +5 C 300,000 feet 50 G s, ms. 20 G s, 75-3000Hz. 3.2 oz. (90g) Max. NOTES 1. All wired terminals must be connected together during this test. Dielectric withstanding voltage and insulation resistance are measured between all mutually insulated wired terminals and between all these terminals and case. Tyco Electronics I &

FOR MORE INFORMATION Technical Support Internet: E-mail: www.tycoelectronics.com/adm newproducts@tycoelectronics.com USA: +1 (800) 522-6752 Canada: +1 (905) 470-4425 Mexico: +1 (800) 733-8926 C. America: +52 (0) 55-06-0803 South America: +55 (0) -2103-6000 Hong Kong: +852 (0) 2735-1628 Japan: +81 (0) 44-844-80 Great Britain: +44 (0) 208-420-8341 France: +33 (0) 1-3420-8888 Germany: +49 (0) 6251-3-0 Italy: +39 (0) 0-40-1 India: +91 (0) 80-285-40800 Tyco Electronics Corporation Harrisburg, PA tycoelectronics.com Copyright 2008 Tyco Electronics Corporation 5-1773453-6 5M GADM/FP /08 CII, TE LOGO and TYCO ELECTRONICS are trademarks.

TERMINALS B Solder Pin Terminals Tin/Lead Plated C Solder Hook Terminals Tin/Lead Plated.062±.002 DIA PINS 2 PLCS).062±.002 DIA PINS (5 PLCS).062±.002 DIA HOOKS 2 (PLCS).062±.002 DIA HOOKS (5 PLCS) K Terminal Shield.20.10.26 GOLD PIN TERMINALS FOR MIL-C-39029/22B 192 SOCKET PINS.38.51.26.76.38.18.10.20.30.60 Terminal View.200.510.100.255.260.377.510.255.190.300.510.100.200.300.600.51 GOLD PIN TERMINALS FOR MIL-C-39029/22B 192 SOCKET PINS DC Coils Terminal Wiring DC Coils w/transient Suppression & I Tyco Electronics

PRODUCT OUTLINE DIMENSIONS The standard terminal types and enclosures are illustrated below with dimensions in inches ± 0.010 and (millimeters ±0.25). representative drawings are shown below. "U" "Y" 1.718 MAX.150 1.718 MAX.625.937.150.625.937 FULL R 6 PLCS.156 "X" "R" "Z" FULL R 6 PLCS 1.718 MAX.625.810.625.150 1.718 & I Tyco Electronics