ZYPHO IZI INSTALLATION MANUAL. Please read the entire manual before starting the installation process. (2) (1)

Similar documents
MEGAFLO Eco MEGAFLO HORIZONTAL SHRU IZI. MEGAFLO 1 Product 16 Guide INSTALLATION MANUAL

FREQUENTLY ASKED QUESTIONS

Ecodrain V1000. Selection and Installation Guide for Residential Applications TM MC TM

Installation instructions. RECOUP Retrofit+ Shower Waste Water Heat Recover unit

IKEA bathroom. GODMORGON bathroom series, wash-basins, mixer taps, shower mixers and accessories

installation INSTRUCTIONS

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

Everyday life at home puts high demands on kitchen mixer taps. To ensure that all our kitchen mixer taps comply with our strict standards for quality

Description of the property and water systems:

Cordless Electric Broom

Xaact Spot. Xaact Hot Spot

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Installation & Operating Instructions

ROUGH IN VALVES. Installation Manual MB439 - SV9INC.219 EU MB440 - SV9INC.220 EU MB441 - SV9INC.221 EU MB442 - SV9INC.222 EU MB443 - SV9INC.

Ireland. Australia. New Zealand

FONTANE BIANCHE 10/2016

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER MANUAL IMPORTANT

Target Monobloc Kitchen Mixer Chrome

Flo-Rite-Temp Instantaneous Steam/Water Heater

Rechargeable UV-A LED/Emergency Light

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Operation Manual Vortex mixer unitexer 1

OPERATOR'S MANUAL CD 400 / CD 500

Legionella Policy and Procedure

Beeline Monobloc Kitchen Mixer Tap

Everyday life at home puts high demands on kitchen taps. To ensure that all our kitchen taps comply with our strict standards for quality and

Installation & Operation Manual Ice Cream Freezers

OWNER S MANUAL & WARRANTY

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

INSTRUCTION MANUAL HS-229G

Legionnaires Disease Risk Assessment

Read All Instructions Thoroughly Before Installing or Using the Disposer.

InstructIon Manual KrEs EQuIPMEnt stands

Recirculating Cooler SRC14

Beautifully Traditional

Capri Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

Ireland. Australia. New Zealand

Pipe Sizing Table. Hydraulic Load Served (fixture units)

WC2 & WC3 Installation & Maintenance Instructions

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

Artisan Thermostatic Bath Filler

music hall wcs-2 wet vacuum record cleaner music hall audio llc

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Friwa Compact. Operating instructions EN

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

ENGINEERING SPECIFICATIONS

Cistern-fed water heating

Preamplifier Power Supply PPS-02 user's guide

Price Book 2015 Drum Pumps For Non-Corrosive Liquids

Nero Tap Range. Fitting Instructions & Contents List

Pear Kitchen Sink Tap

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Hotflo. Unvented point of use hot water

Ireland. Australia. New Zealand

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

INSTALLATION INSTRUCTIONS

LONGONI ENGINEERING SRL

Flo-Rite-Temp Instantaneous Steam/Water Heater

Hot and cold taps and mixer taps are proprietary fittings and as such carry a standard manufacturer s warranty.

EMERGENCY SHOWERS AND EYEWASHES

READY RACK HOSE WASHER

OPERATOR'S MANUAL HD-400

1PIECE FREESTANDING BATHTUB

Pisa Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Smart IR Sensor. Installation and Operation Manual PNEG Date: PNEG-1640

K Specifications. Max. Water Volume

HKF 8180 Operating instructions

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

Ireland Australia New Zealand

Mira Vision Wireless Controller

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

Tsunami 6 Site Ebb & Flow Gro System Instruction Manual

Double Door - Dual Zone Wine Cooler

REMOTE FAUCET PUMP SYSTEM

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

Singulier Spout Tube Basin Mixer Installation and User Guide

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

User and Installation Instructions. Opus 700 Electric Salamander Grill OE7304 IS318 ECN3011

MINI DEHUMIDIFIER. SD-350TI With UV Light SD-350 INSTRUCTION MANUAL

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

Oblo Basin and Bidet Monobloc Installation and User Guide

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

Installation Manual QB1 21 & QB1-21C

DOMESTIC WATER RECORDS

Advantages of Disposable Systems

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

14 Upright Vacuum with HEPA Filter & Dual Power

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Transcription:

ZYPHO IZI INSTALLATION MANUAL (2) (1) Please read the entire manual before starting the installation process. (1) and (2), accessories purchased separately

ÍNDEX PRODUCT Pag.1 IMPORTANT Pag.1 INSTALLATION Pag.2 INSTALLATION CONFIGURATION Pag.3 TECHNICAL SPECIFICATIONS Pag.3 SHOWER DRAINS RECOMMENDED FOR ZYPHO IZI Pag.3 PACKAGE CONTENTS Pag.4 DIMENSIONS Pag.4 SAFETY Pag.5 MAINTENANCE Pag.5 WARRANTY Pag.6 CONTACTS Pag.6

PRODUCT ZYPHO is a heat exchaning unit that will allow you to recover the heat contained in the shower waste water and to transfer this heat to the cold water before it goes to the shower mixer tap and/or water heater device. There is no contact between the water supply and the drain water. The transfer of heat is achieved through a double-walled copper coil heat exchanger in accordance with the regulations EN 1717. When utilizing the ZYPHO izi, the cold water feeding into your mixer valve or heater device is pre-heated to approximately 20-25 C, an increase of approximately 15 C (depending on the type of configuration and flow of the shower), the result is a significant energy saving. IMPORTANT! The ZYPHO should only be installed by a competent professional who has the expertise to be guided by this manual. Please read the entire manual before starting the installation process. Should you have any technical questions don t hesitate to contact us. Non-compliance with the recommendations for installation and use may void any warranty. Keep this manual in a safe place for easy reference when required throughout the life of the product. This product doesn t include a shower drain. 1

INSTALLATION INSTRUCTIONS 1 2 ZYPHO has an internal slope of 2%. ZYPHO should be leveled. 3 5 4 2

INSTALLATION CONFIGURATION Choose configuration A, B or C a) a) a) b) b) b) c) c) c) d) e) d) e) d) e) a) water heater b) hot water pipe c) warm water pipe d) cold water pipe e) drain pipe TECHNICAL SPECIFICATIONS Unit Value Temperature range ºC 0-60 Maximum mains water pressure bar 6 Pressure drop with mains water at 9.2L / min bar 0.3 Maximum shower flow l/min 30 Heat exchanger material - Copper ZYPHO body material - ABS Net weight kg 5 SHOWER DRAINS RECOMMENDED FOR ZYPHO IZI Brand Model Height (cm) Depth of water seal (mm) Filter included Observations Geberit Setaplano 9,5 50 Yes - Nicoll Turboflow2 8 50 Yes - Wirquin James 360 7,8 50 Yes - Viega Tempoplex Plus Drain 9 60 No Sieve insert (Filter) purchased separately Any other shower drain with a filter, preventing large debris and hairs to accumulate inside the unit 3

PACKAGE CONTENTS Nº Description Material Connection Qty 1 Drain water inlet ABS F 1 2 Water discharge Ø40 PVC M 1 3 Input connector 1/2 Brass M 1 4 Output connector 1/2 Brass M 1 5 Adjustable foot Steel / Plastic - 4 DIMENSIONS 4

SAFETY Tested Product ZYPHO heat exchanger is double walled according to European regulations EN 1717 ( Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow ). Complementary to (preventive) quality control during production process, we carry out test in all ZYPHO units in our factory before packaging and shipping. Tests are done to the copper main water circuit and connections by pressurizing it up to 7 bar and to the drain water circuit and sealing points up to 1 bar to ensure that there are no leaks or defects Legionella Prevention ZYPHO's design allows to minimize Legionella-related risks: - The unit has no dead spaces and is subject to high flow rates which prevents water from stagnation. - Drain water never stays a long time inside of the unit since its construction guarantees that it is fully drained out at the end of the shower. - After shower, fresh water cools down below 25 C, as recommended by the WHO and the European Working Group for Legionella Infections. - The ZYPHO is always installed relatively close to the shower mixer which minimizes the distance between the unit and the shower valve. - Copper coil itself contributes to reducing Legionella-related risks. MAINTENANCE ZYPHO izi must be installed with a shower drain that incorporates a filter or a trap to prevent the passage of debris. Like any other drain pipe, we recommend a periodically cleaning. Use a non-corrosive drain cleaner and ZYPHO s cleaning brush or other flexible drain brush that easily goes through the ZYPHO pushing the debris towards the sewer. See ZYPHO s izi accessories section on our website ( www.zypho.eu ) for our recommendation for the ZYPHO brush. 5

WARRANTY 10 YEARS During the warranty period, EIDT, SA or an authorized company will replace or repair any Product that has a defect in design, material or workmanship provided the Product is returned, packaging and transportation charges prepaid, to Manufacturer with Manufacturer s prior permission (unless otherwise required by law). Will be excluded from this limited warranty defects caused by: Installed water pressure above the limits regulated by law. Use of the system without filter or trap. Inadequate cleaning of the filter or trap. Inadequate installation of the ZYPHO. Misuse of the ZYPHO or normal wear of its componentes Unauthorized repairs and modifications. Damage due to an accident, incl. during transportation, neglect, or any cause other than ordinary use. The statement of limited warranty is valid in any country where the ZYPHO is distributed and represented. Contacts for additional warranty services and services at the customer premises may be available from any representative or agent of ZYPHO in countries where it is distributed. CONTACTS PRODUCT DEVELOPED BY EIDT, SA EN5, Z.I. Comercio Industria, Armazém 29. 2870-500, Montijo Portugal +351 210 991 351 b2b@zypho.eu www.zypho.eu PATENTED (PCT054506) Z8DWIZPT-V01-1017-EN 6