S Low loss coax cables with foamed PE

Similar documents
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Caledonian Flame Retardant Coaxial Cables

Multi-Core Fire Resistant Cable

CATEGORY 6A FTP RJ45 SOLUTION

PRODUCT CATALOGUE Norröna

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Single core cables with reduced wall thickness

Traction Cable Radox 3 GKW

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

SPECIAL ELECTRICAL AND OPTICAL CABLES

Caledonian Fire resistant Coaxial Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

Introduction.

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Weight / 003 -Z M5 (SUCOFEED ¼ HF) bulk 10 pcs g / 5.25 oz.

Caledonian fire Resistant signal & Data cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

FIRE RESISTANT CABLES

The Quality Connection. BETAflam Fire Resistant Safety Cables

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

Compact Module. Category 6A FTP Cabling System 1.1

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

INTERNATIONAL STANDARD

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

PRAKAB PRAŽSKÁ KABELOVNA, s.r.o. COMPANY PROFILE 2015

Flexible Power Cable DLO

Photovoltaic Cables EN H1Z2Z2-K

NEMA Standards Publication WC Standard for Controlled Impedance Shielded Twisted Pairs in Internal Electrical Cable

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Environmental Product Declaration

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

INTERNATIONAL STANDARD

The Quality Connection. BETAflam Safety cables for highest demands

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

BS /1000V XLPE Insulation LSZH Sheath Cables

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Category 5 Premise Wire

Optional Parts (sold separately): E-4WNSC-x 4-Wire Non-Sensing cable (available in lengths 10/25/50/100 feet and custom lengths up to 1000 feet)

Product Specification CAT 6 UNSHIELDED PATCH CORDS

The Next Generation of Data Communicatons Solutions

Cable technology for highest safety requirements

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

fire resistant cables

High Performance LSZH Fire Resistant Cable

Catalogue Telecommunication Cables INTRODUCCIÓN

Firecel Safety Cables

OIL & GAS INDUSTRY OTHER INDUSTRIES

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

AUTOMOTIVE MINIATURE WIRE (AMW)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Power Control Cable Iec

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Industrial Ethernet Circular Sealed RJ-45 Connectors

Linear Heat Detection

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

HELKAMA. Optical Fibre Cables

HYDRAULIC CRIMPING TOOL HYDRAULIC PRESSHEAD

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Installation Guide. Ceiling PIR Detector (311) Features and Connections

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

industry solutions: military

The Quality Connection. BETAflam safety cables for highest demands

APR 17 Rev A

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

LSH (E 2000 ) High performance. High reliability. High safety. High flexibility

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Telecommunication Cables

Belden Infinity C-TC+ Cables for Extreme Flexing

NEMA Standards Publication WC Standard for Controlled Impedance in Internal Electrical Cable

Special Provision No. 683S28 December 2017

Transcription:

S Low loss coax cables with foamed PE Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % of the speed of light Epsilon r 1.5 Signal delay 4.1ns/m Insulation resistance > 10 8 Mm Single screening effectiveness 40 db up to 1 GHz Double screening effectiveness 80 db up to 6 GHz General cable data Dielectric material foamed polyethylene Min. bending radius static 5 x Ø jacket Min. bending radius dynamic 15 x Ø jacket Temperature range jacket mat. PVC, PVC (UL), PVC2 (LM): 25 C to +85 C Temperature range jacket mat. PE, LSFH, PUR, RADOX : 40 C to +85 C 28

single/double screen, 50 Attenuation typical values at +20 C ambient temperature and sea level 1.4 2.5 Attenuation (db/m) 1.2 1 0.8 0.6 0.4 0.2 Attenuation (db/m) 2 1.5 1 0.5 0 0 0.5 1 1.5 2 2.5 S_01162_D-01 S_03232-01 S_04172_D (up to 5 GHz) S_06132_D-10 (up to 4 GHz) S_07232-01 0 0 1 2 3 4 5 6 S_02112_D S_02132_D-60 S_04262_D-02, S_04262_D-09 S_06162_D-03 CW Power max. values at +40 C ambient temperature and sea level Power (W) 1800 1600 1400 1200 1000 800 600 400 200 Power (W) 700 600 500 400 300 200 100 0 0 0 0.5 1 1.5 2 2.5 0 1 2 3 4 5 6 S_07232-01 S_04172_D (up to 5 GHz) S_06132_D-10 (up to 4 GHz), S_03232-01 (up to 1 GHz) S_01162_D-01 S_06162_D-03 S_04262_D-02, S_04262_D-09 S_02112_D, S_02132_D-60 29

S Low loss coax cables with foamed PE Cable types Single screen HUBER+SUHNER type Item no. Center conductor Dielectric Screen 1 Design Mat. S_03232-01 22610021 strand-7 Cu 1.20 SPE 2.95 Cu 3.60 95 S_07232-01 22510410 strand-7 Cu 2.85 SPE 7.42 Cu 8.15 95 % Double screen HUBER+SUHNER type Item no. Center conductor Dielectric Screen 1 Design Mat. S_01162_D-01 84061579 strand-7 Cu 0.54 SPE 1.37 Cu 1.70 91 S_02112_D 22511910 strand-19 CuSn 0.90 SPE 2.39 Cu 2.90 96 S_02132_D-60 a) 84010316 wire CuAg 0.88 SPE 2.42 CuAg 2.95 92 S_04172_D 22511598 wire CuAg 1.40 SPE 3.78 CuAg 4.20 96 S_04262_D-02 22512107 strand-19 CuAg 1.43 SPE 3.77 CuAg 4.35 92 S_04262_D-09 84034611 wire CuAg 1.40 SPE 3.78 CuAg 4.20 96 S_06162_D-03 84061578 wire CuAg 2.05 SPE 5.60 Cu 6.10 93 S_06132_D-10 22511629 strand-7 CuAg 2.25 SPE 5.80 CuAg 6.55 94 % a) UL recognised (see UL types page 66) All green highlighted types are Low Smoke Free of Halogen (LSFH ) acc. waste electrical and electronic equipment (WEEE) and restriction of the use of certain hazardous substances (RoHS) directive. 30

single/double screen, 50 Screen 2 Jacket Weight % Mat. Operating voltage Colour kg/100 m kv GHz Max. operation frequency -- -- PVC2(LM) 5.00 black 3.80 0.45 1 U8 -- -- PVC2(LM) 10.30 black 14.90 1.05 1 X11 Cable group* * for suitable connectors Screen 2 Jacket Weight % Mat. Operating voltage Colour kg/100 m kv GHz Max. operation frequency 2.20 90 LSFH 2.70 black 1.30 0.20 2 X3 3.50 84 PUR 4.50 black 3.70 0.35 6 S8 3.60 96 PVC(UL) 4.80 black 4.50 0.35 6-4.70 94 PE 5.70 black 5.50 0.55 5 S16 5.25 77 LSFH 6.50 black 6.80 0.50 6 X8 4.70 93 LSFH 5.70 black 6.30 0.50 6 S16 6.75 85 LSFH 7.90 black 11.00 0.75 6 S24 7.25 96 PVC 8.95 black 14.00 0.75 4 S26 Cable group* * for suitable connectors 31

S Low loss coax cables with tape Cable design Electrical cable data Impedance () 50 Capacitance 82 pf/m Velocity of signal propagation 82 % (SPUMA: 85%) of the speed of light Epsilon r 1.5 (SPUMA: 1.38) Signal delay 4.1 ns/m (SPUMA: 3.9 ns/m) Insulation resistance > 10 8 Mm Screening effectiveness 90 db up to 6 GHz General cable data Dielectric material foamed polyethylene Min. bending radius static 5 x Ø jacket Min. bending radius dynamic 15 x Ø jacket Temperature range jacket mat. PVC, PVC (UL), PVC2 (LM): 25 C to +85 C Temperature range jacket mat. PE, LSFH, PUR, RADOX : 40 C to +85 C 32

double screen/tape, 50 Attenuation typical values at +20 C ambient temperature and sea level 1.8 1.6 1.4 Attenuation (db/m) 1.2 1 0.8 0.6 0.4 0.2 0 0 1 2 3 4 5 6 S_02162_B S_02132_B S-03262_B-61 S_04212_B, S_04262_B-01, S_04272_B, S_04162_B-60, S_04162_B S_07272_B-05 S_07212_BD, S_07262_BD, S_07262_BD-AH S_10162_B-11, S_10172_B-11, SPUMA_400 / 400-FR-01 CW Power max. values at +40 C ambient temperature and sea level 1600 1400 1200 1000 Power (W) 800 600 400 200 0 0 1 2 3 4 5 6 S_10162_B-11, S_10172_B-11, S_07272_B-05, S_07262_BD, S_07262_BD-AH, S_07212_BD SPUMA_400 / 400-FR-01 S_04162_B-60, S_04162_B, S_04212_B, S_04262_B-01, S_04272_B S_02132_B, S_02162_B, S-03262_B-61 33

S Low loss coax cables with tape Cable types HUBER+SUHNER type Item no. Center conductor Dielectric Screen 1 Design Mat. S_02162_B 22512310 strand-7 Cu 0.80 SPE 2.10 AL-PES 2.15 100 S_02132_B 23032987 strand-7 Cu 0.80 SPE 2.10 AL-PES 2.15 100 S_03262_B-61 a) 84078137 wire Cu 1.065 SPE 2.96 AL-PES 3.05 100 S_04162_B-60 a ) 84023780 wire Cu 1.40 SPE 3.80 AL-PES 4.00 100 S_04162_B 84068745 wire Cu 1.40 SPE 3.83 AL-PES 4.00 100 S_04212_B 22511855 wire CuAg 1.40 SPE 3.82 AL-PES 3.96 100 S_04262_B-01 84000918 wire CuAg 1.40 SPE 3.82 AL-PES 3.96 100 S_04272_B 22511622 wire CuAg 1.40 SPE 3.82 AL-PES 3.96 100 SPUMA_400 84102703 wire AICu 2.74 SPE 7.24 AL-PES 7.40 100 SPUMA_400-FR-01 84132035 wire AICu 2.74 SPE 7.24 AL-PES 7.40 100 S_07272_B-05 23029079 wire Cu 2.68 SPE 7.29 AL-PES 7.45 100 S_07212_BD 22511864 strand-7 CuAg 2.82 SPE 7.38 CuAg 8.00 96 S_07262_BD 22511767 strand-7 CuAg 2.82 SPE 7.38 CuAg 8.00 96 S_07262_BD-AH 23023566 strand-7 CuAg 2.82 SPE 7.38 CuAg 8.00 96 S_10162_B-11 23002145 wire AlCu 3.80 SPE 9.90 Cu 10.00 100 S_10172_B-11 22512320 wire AlCu 3.80 SPE 9.90 Cu 10.00 100 % a) UL recognised (see UL types page 66) All green highlighted types are Low Smoke Free of Halogen (LSFH ) acc. waste electrical and electronic equipment (WEEE) and restriction of the use of certain hazardous substances (RoHS) directive. 34

double screen/tape, 50 Screen 2 Jacket Weight % Mat. Operating voltage Colour kg/100 m kv GHz Max. operation frequency 2.70 75 LSFH 3.15 black 2.50 0.25 6 S9 2.55 90 PVC 3.20 black 1.90 0.35 6 S9 3.80 74 LSFH 4.50 black 3.15 0.40 5 X7 4.53 86 LSFH 5.50 black 4.78 1.00 6 X9 4.60 70 LSFH 5.50 black 5.00 0.50 6 X9 4.48 87 PUR 5.30 black 4.10 0.50 18 X9 4.48 87 LSFH 5.50 black 4.10 0.50 18 X9 4.48 86 PE 5.50 blue 4.40 0.50 18 X9 8.14 78 PE 10.25 black 11.50 1.60 6 U30 8.14 78 LSFH 10.25 black 11.50 1.60 6 U30 8.10 88 PE 10.20 black 13.25 1.05 5 U30 8.10 100 PUR 10.80 black 20.60 1.05 3 S32 8.10 100 LSFH 10.80 black 20.60 1.05 3 S32 8.10 100 LSFH 10.80 black 40.50 1.05 2 S32 10.80 80 LSFH 12.90 black 15.00 1.70 7.5 S39 10.80 80 PE 12.90 black 15.00 1.50 7.5 S39 Cable group* * for suitable connectors 35