HSD Dry Cabinet. Outstanding performance

Similar documents
HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Long Term Storage Cabinet

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

XSD Dry Cabinet

SD Storage Cabinet. Outstanding performance

SD Storage Cabinet. Outstanding performance

SD Storage Cabinet

SDR Dry Room. Outstanding performance

SDB Storage Cabinet

XSD Dry Cabinet

XSD Dry Cabinet

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

A Member of the ASYS Group A Member of the ASYS Group PRODUCT CATALOGUE

Revolution of Low Humidity Storage!!

Constant climate chambers

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

KMF Environmental test chamber for constant climate

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Drying and heating chambers

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Constant climate chamber with humidity

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Constant climate chamber with ICH-compliant illumination

INSTRUCTION MANUAL ESDA Cabinets with display

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Constant climate chambers

Chromatographic Air circulated Refrigerator, two-door TC 603

Environmental simulation chamber for complex alternating climate profiles

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Dew point set DS 400

Revolution of Low Humudity Storage!!

Constant climate chambers

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

DP 300 mobile dew point instrument

NEW GENERATION. Efficient use of valuable space INCUBATORS

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Constant climate chambers

FITOCLIMA 600 & 1200 STABILITY


Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Plant growth chambers

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

ULTRA-LOW HUMIDITY SEIKA. ERC Co., Ltd. ULTRA-LOW HUMIDITY STORAGE CABINETS 1%RH. Conforms to IPC/JEDEC J-STD-033D and IPC-1601 Guidelines.

Specifications Minimum Typical Maximum Unit

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Constant climate chambers

Constant climate chambers

EC 160 CO 2. Incubator

Laboratory Refrigerator/Deep Freezer TC 802

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

Constant climate chambers

Drying and heating chambers. Series ED FD FED FP M

Chromatographic Air circulated Refrigerator, two-door TC 603

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

EST User Manual. (Please read this manual carefully before using)

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

HUM-M2 Humidity Sensor Module Description

Mercury Vapor Monitor VM-3000

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

FITOCLIMA 600 & 1200 STABILITY

New Generation KBF 240 series

CO₂ incubators. C CB series

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Instruction Manual heater SH for SD dry cabinets

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Huminator II. Precision Humidity Generator. ww.testo.in

VM-3000 Mercury Vapor Monitor

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Automatic Isokinetic Sampler ST5

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Technical data sheet. Lyovapor L-300

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

portable gas analyser

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Model C 170 CO 2 incubators with hot air sterilization

INSTRUCTION MANUAL SD and SDB Cabinets

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

DEKO Washer-disinfector WASHROOM SYSTEMS

Infrared Temperature Sensor

incubator, the best in its class

VM-3000 Mercury Vapor Monitor

Model KBF 240 Constant climate chambers with large temperature / humidity range

Reproducible Climate...

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

FITOCLIMA 600 & 1200 PHARMA

Transcription:

Dry Cabinet Outstanding performance The HSD cabinet series has an outstanding performance for drying moisture sensitive components and pcb s as a result of a high performance drying unit. Therefore it is very suitable for operation with frequent approach. The dynamic drying unit of the 5000 series reaches very reliable low humidity values 0,5% RH and automatically regenerates if necessary. Humidity, temperature and alarm functions are shown and can be adjusted on a digital display. Data can be taken out from the cabinet through a standard Ethernet connection with available software.

Standard Features User friendly handling Display with easy menu structure ESD features Norm (IEC 61340-5-1) ESD metal painted body (<10 6 Ohm/sq) Dissipative glazing (in- and outside 10 8 Ohm/sq) Online functionality Interface and data logging through standard Ethernet interface Compatible with new MSL 2.0 software Door & humidity alarm buzzer Longer door openings are detected, high RH levels are detected Transport Castors Lockable doors 6 doors locked with key Sliding shelves In height adjustable chrome steel shelves (5 pcs) U-5000 series drying unit 0,5% RH, made in Germany Rotronic sensor Precision sensor, accuracy +/- 0,8 % RH, +/- 0,3 C Power supply Power cord 5 meter with IEC plug Benefits Drying time (see reference table) Fast drying time, Level 3 component, <1,4 mm = 18 hours (60 C / 1% RH) Recovery time after door opening < 15 minutes to below 1% (with 1 cabinet and 1 door opening) Energy saving consumption As a result of a Dynamic dry unit, 46 W/h Network Standard ethernet interface IPC According to IPC-JEDEC J-STD 033C & IPC-1601 European Quality Made in Germany Maintenance Easy to service, low maintenance

Technical data cabinet External dimensions: (W x H x D) 1200 x 1675/(1840)) x 658(768) mm Internal dimensions: (W x H x D) 1190 x 1533 x 630 mm Weight: 189 kg Weight on shelf: 50 kg Max. loading capacity: 300 kg Body: Steel, conductive coated 10 6-10 8 Ω/sq Shelves (WxD): 5 pcs, 1150 x 490 mm Volume: 1179 L Electric supply: 230 VAC (120 VAC optional) Power consumption: Average 46 W/h (excl. heating) Protection class: Class 1, hard grounded Humidity level cabinet: 0,5% RH can be reached with drying unit U-5003 Sensor accuracy: +/- 0,8 % RH, +/- 0,3 C Technical data type 2 display Settings Language Menu Nominal Value Humidity Nominal Value Humidity Alarm Delay Humidity Alarm (in combination with heater) Nominal Value Temperature (in combination with heater) Temperature Alarm (in combination with heater) Delay Temperature Alarm Doors Alarm Interlocking Manual Regeneration Display Supply voltage (supplied by drying unit) 24 VAC/DC Input 4 function keys (tactile-touch keys) Display 61 x 33 mm, white, controllable backlight, adjustable contrast Ethernet connection Power consumption at 24 VDC, 40 ma

Technical data Rotronic sensor HC2A-S Based on the Airchip 3000 Technology use the HygroClip 2 probes can be used for control of temperature and humidity. The HygroClip 2 probes can be configured with the ROTRONIC HW4 software and share the following features: Measurement of relative humidity and temperature Programmable automatic sensor test with failsafe mode and sensor drift compensation. Technical data dry-unit U-5000 series Dehumidifying performance: 120 g/h max. Minimal humidity 0,2% RH Dehumidifying Temperature 10 60 C Electric supply: 230 VAC Dimensions (L x B x H): 487 x 487 x 150 mm Weight: 14 kg

Technical data heater SH-230-4 Voltage: 230 VAC / 50 Hz (120 VAC / 60 Hz optional) Power: 780 W Temperature sensor: PTC 100 Thermal protection: 90 C Temperature range: 30-40 C Air flow: 86 m 3 /h Display tolerance: 1 digit at 25 C Technical data N 2 (Auto) Flow Power supply: 90-230 VAC N 2 connection: 8mm hose connection N 2 pressure: 1-6 bar N 2 standby amount: 0-25 L/min N 2 purge: 0-100 L/min Purge time: 0-99 min

Free Totech viewer Writing of climate data, door openings and alarms to SD card Transfer data through Ethernet to PC (history data) User-friendly display of all relevant data Data processing in MS-Excel Seamless documentation Excellent process safety

Performance test Test conditions Instrument: Vaisala Type of dew point sensor: Vaisala drycap 180M Accuracy of dew point sensor: ± 0,2 C at + 20 C (+ 68 F) Location of sensors: In the direct surrounding of the cabinet sensor. Ambient conditions: Hum. 50 ± 5% rh, 22 C ± 2 C, Pressure 994 ± 20 hpa Door openings: 2 door openings, 15 sec. (average RH 0,70%) For more detailed test results, please refer to our website.

Technical drawings Dimensions mentioned in mm. Shelves Number of different types of shelves that can be mounted in the cabinet Number of shelves bottom section 2 3 4 5 Distance (in mm) between shelves if equally divided in bottom section 230 180 130 80 Remaining space between top shelf and middle beam 230 130 105 175 Remaining space between bottom shelf and bottom cabinet 225 175 75 125 Loading capacity shelves m 2 (1155 mm x 780 mm) 1.80 2.74 3.60 4.50 Number of shelves top section 2 3 4 5 Distance (in mm) between shelves if equally divided in bottom section (if bottom shelf is mounted at lowest possible position in top section) 330 230 180 130 Remaining space between top shelf and top beam 375 225 225 125 Remaining space between bottom shelf and middle beam 0 0 0 0 Loading capacity shelves m 2 (1155 mm x 780 mm) 1.80 2.74 3.60 4.50 Measurements can slightly deviate. For loading capacity shelves see specification SDF 1704.

Technical drawings

Options SMD Reel rack ESD coated with reel supports L x W = 530 x 265 mm incl. 18 reel supports. Item number 20014000 Reel support Additional reel supports for 20014000. Item number 20014200 Humidity alarm signal lamp Two-color (orange/green or red/green), magnetically fixed, providing optical signals on operational states and exceeded limit values. Operates on 24V. Item number 20016030 N 2 Autoflow system The autoflow system is developed to use in combination with a Totech drying cabinet. The device is used for the quick removal of moisture in the cabinet after the doors have been opened. The drying process is realised by using Nitrogen (N 2 ), which is purged automatically after the doors are closed. (timer controlled) Item number 22613001 Adjustable legs 4 in height adjustable legs (63-80 mm) Item number 20010010

Options Shelf standard For cabinets type 1106 and 1104 Item number 20111409 Brackets 2 pcs Item number 20111709 X Feeder system This feeder rack is suitable for Siemens X Feeder systems. Sold in combination with reel rack. Item number 46204004 S Feeder system This feeder rack is suitable for S Feeder systems. Sold in combination with reel rack. Item number 46204009 Hygroclip 2 Probe with maximum accuracy for all climate measurements. Item number 470000027 Excange calibrated sensor: Item number 47000040 Humidity calibrator Hygropalm 22 Precision measuring device for calibrating sensors. Set including Hygroclip sensor, case and cable: Item number 20001019 Hygropalm only: Item number 20001016

Options MSL 2.0 software for 1000 components Software solution for the monitoring of moisture sensitive components and their MSL states during storage and processing in the production. The exact drying state individually for each component is monitored and displayed with the software. One of the possibilities is that it can read out multiple HC2A-S sensors. To adjust storage conditions, picking of stock, removal of used parts and more stock control. A complete history for each component is traceable up to the full processing. The evaluation of the drying conditions is based on the requirements of the IPC / JEDEC J-STD-033B1 directive. Item number 20010036 MSL software upgrade with additional 1000 components Upgrade to monitor an additional 1000 components Item number 200174502 Totech Monitor software Realtime cabinet monitoring with alarm function, sending e-mails with detailed information on the status of the cabinet.history data files with graphical overview Item number 47000583 Heater SH 230-4 Max. 40 C heater Item number 21001001