Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Similar documents
2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models UP TO 18.0 SEER, 12.8 EER AND 15.5 IEER

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Up to 16.1 SEER, Up to 14.3 EER and Up to 15.4 IEER

3- to 24-Ton Models. Commercial Packaged Rooftop Units. The most energy-efficient rooftop unit in the industry *

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

Lennox Mini-Split Systems Year-Round Comfort and Performance

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

Performance and Reliability. CB*, C* and TA* Models

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 18.0 SEER, Up to 12.8 EER and 14.5 IEER

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

True performance and rugged durability. TU, LF and LD Models

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

48PGD/E/F/L/M/N PG20-28

RGE 13 A T - 1 A

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48TM GAS HEATING/ELECTRIC COOLING UNITS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

L CONNECTION NETWORK Commercial Controls

13 GEP A L P - 1 A

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

THE RIGHT SPEC. RIGHT NOW.

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Cooling & Heating Products Residential and Commercial

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Commercial Packaged Rooftop Units 3- to 24-Ton Models. Up to 16.1 SEER, Up to 14.3 EER and Up to 16.8 IEER

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

RHEEM PACKAGE GAS/ELECTRIC

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Submittal Data Performance Data Electrical Data

50TM TFF COMBINATION HEATING/COOLING UNITS

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

50TM COMBINATION HEATING/COOLING UNITS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

p r e d a t o s e r i e s S I N G L E - P A C K A G E R O O F T O P S

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Submittal Summary Page

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

DCG Commercial. Submittal Data Form

TECHNICAL SPECIFICATIONS

Xc21 air conditioner up to seer Xc21

Landmark Rooftop Units 50 HZ

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

R-410A LUXAIRE ACCLIMATE DYX MODELS 2-4 TON 60 Hertz

SKYPAK II, 3 Ton Series, gives you a

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

SKYPAK II, 3 Ton Series, gives you a

COMMERCIAL HVAC PRODUCT GUIDE COMMERCIAL

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

The XP21 raises the bar for efficiency and comfort.

The XC17 is an efficiency expert.

PAR5. Product Specifications

Voyager. 12½ to 25 Ton Light Commercial Packaged Units with ReliaTel Microprocessor Controls

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

The XC21 delivers the ultimate in comfort.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

COMMERCIAL HVAC PRODUCT GUIDE INDUSTRY-LEADING EFFICIENCY AND INNOVATION TO MEET YOUR NEEDS

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

4YCC3048A3096A /3/ /

LIGHT COMMERCIAL. Packaged Units and Split Systems APPLICATIONS: OFFICES RETAIL STORES RESTAURANTS CLINICS

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Energence Rooftop Units 60 HZ

INSTALLATION INSTRUCTIONS

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

RSG16**S1M. Split System Air Conditioner 16 SEER

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

WPH4 Product Specifications

Transcription:

Landmark Performance Marked by Flexibility Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models Up to 13.0 SEER, 14.0 IEER and 12.7 EER

Performance Marked by Flexibility When it comes to reliable and efficient performance, Landmark rooftop units have always been a standout for light commercial applications. Now we ve built more flexibility into the line, making Landmark an excellent choice for virtually any application. Landmark rooftop units at a glance: Engineered for installation flexibility, energy-efficient performance and easy serviceability Gas/electric, electric/electric or heat pump units, ranging in sizes from 3 to 25 tons Standard- and high-efficiency units available More than 100 field-selectable options to ensure fast and easy installation Optional MSAV supply fan technology with variable frequency drive that delivers fan power savings of up to 61%* Available through select Lennox PartsPlus stores and Lennox commercial warehouses Configuration choices for greater energy-savings potential The advantages of Landmark rooftop units lie not only in its flexibility and simplicity, but also in its efficiency. Landmark units are now available in standard- and high-efficiency models, and with the addition of the optional MSAV supply fan, are up to 25% more efficient. For additional savings, high-efficiency models may qualify for state and local utility rebates. Over 30 features designed to reduce installation and service time Landmark rooftop units have been designed so that installation and service time are reduced. An isolated compressor compartment means easier, more accurate charge confirmation. The slide-out blower makes cleaning the blower wheel and belt tensioning, adjustment or replacement quicker and easier. And the accessible gas compartment allows access to all gas components, making analysis and service easier. EFFICIENCY RATING Up to 13.0 SEER, 14.0 IEER and 12.7 EER WARRANTIES 15-Year Limited Warranty on stainless steel gas heat exchanger 10-Year Limited Warranty on aluminized gas heat exchanger 5-Year Limited Warranty on compressor 3-Year Limited Warranty on Environ Coil System 1-Year Limited Warranty on covered components See warranty certificate for actual details. Call 1-877-792-0024 to get quotes within minutes, and to check availability in your area. Readily available for your specific lightcommercial application Every Lennox commercial distribution facility has Landmark units ready for immediate shipment, thanks to daily restocking. In many major markets, units can be picked up the same day they re ordered, and units are available within 48 hours or less to 98% of North America. *Part load, IEER improvement. Comparing standard 11.2 Ieer system to optional MSAV 14 IEER system.

Field-installed options allow extensive customization Landmark is ready to conform to your application Landmark units are available in 3- to 25-ton gas/electric, electric/electric and heat pump configurations. With more than 100 field-installed options available, installers can have exactly the right solution for their needs at the job site, and customers can get the unit that fits their application perfectly. Field-installed accessories for fast replacement Landmark units include convenient features like plug connections for wiring, panel knock-outs and pre-installed accessory framing. You can choose a stock unit and quickly install accessories for those fast-track replacement jobs. Field-powered GFI Disconnects Economizers with single or dual enthalpy control Electric heat 50% constant-volume power exhaust fan CO 2 sensor Return and supply air smoke detectors Low ambient kits Hail guards Coil guards Link to the L Connection Network line of commercial controls with an optional Network Thermostat Controller LPG Conversion Kit (Gas/Electric only) -40 F cold weather kit (Gas/Electric only) Combustion air intake and flue exhaust extensions (Gas/Electric only) Blower proving switch Dirty filter switch Manual outdoor air dampers (25%) Motorized outdoor air dampers Factory-installed options for fast installation For quick, built-to-order solutions, Landmark units can be built and tested at the factory to exact specifications in weeks with these options: MSAV (Multi-Stage Air Volume) supply fan option Coil corrosion protection Stainless steel heat exchanger Hinged doors Factory options or field accessories For maximum time and cost flexibility, choose to have these options installed in the field or at the factory. Economizers Barometric relief dampers High- and low-static drive kits Heaters (electric/electric only) BACnet and Novar 2051 (gas/electric and electric/electric only)

Landmark Hinged Access Panels: Factory option provides quick access to components and protects panels and roof from damage during servicing. 2 Full-Perimeter Base Rail (with Rigging Holes): Provides greater structural integrity, so the unit is easier to handle when rigging and transporting. 8 5 3 Isolated Compressor Compartment: Allows performance check during normal compressor operation without disrupting airflow. 4 Fork Slots on Three Sides: Easy to pick up and transport units from almost any angle. 5 Independent Motor Mount: Allows for easy and efficient service access without removing the top panel. 6 Corrosion-Resistant, Removable Drain Pan: Provides application flexibility, durability and improved serviceability. Bottom drain capability also standard. 7 Direct-Spark Ignition: Electronic ignition eliminates standing pilot and enhances efficiency. 8 Predefined Supply Fan Motor/Drive Combinations: Make selecting components to meet static and airflow requirements quick and easy. 1 2 6 9 Scroll Compressor: Standard on all units for reliable long-term operation. 7 High-Pressure Switch: Improves reliability by safeguarding compressor from extreme operating conditions. Environ Coil System: Uses up to 52% less refrigerant, is up to 59% lighter and has up to 20% fewer brazed joints than typical units (standard on all 7.5- to 12.5-ton G/E and E/E models; heat pump models use tube and fin coils). 4 3 10 9 11 Landmark high-efficiency rooftop unit performance specifications Cooling Data Heating Input Physical data Gas/ Electric Units ELECTRIC/ Electric Units NOM. TON MODEL EER IEER LOW STD. MED. HIGH DIMENSIONS H X W X L [INCHES] SHIP WT. [LBS.] 7.5 KGA092H4B/M 12.5 13.0/14.0 130,000 180,000 240,000 47 x 61 x 102 1,154 8.5 KGA102H4B/M 12.2 12.9/14.0 130,000 180,000 240,000 47 x 61 x 102 1,174 10 KGA120H4B/M 12.0 13.0/13.8 130,000 180,000 240,000 47 x 61 x 102 1,222 KW Range 7.5 KCA092H4B/M 12.7 13.0/14.0 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,112 8.5 KCA102H4B/M 12.4 12.9/14.0 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,132 10 KCA120H4B/M 12.2 13.2/14.0 15.0 22.5 30.0 45.0 60.0 47 x 61 x 102 1,187

Landmark standard-efficiency rooftop unit performance specifications Cooling Data Heating Input Physical data Gas/Electric Units electric/electric units Heat Pumps NOM TON. MODEL EER SEER OR IEER LOW STD. MED. HIGH DIMENSIONS H X W X L [INCHES] 2 KGA024S4D 11.4 13.0 65,000 39 x 47 x 86 591 2.5 KGA030S4D 11.2 13.0 65,000 39 x 47 x 86 593 3 KGA036S4B 10.7 13.0 65,000 105,000 39 x 47 x 86 594 4 KGA048S4B 11.0 13.0 65,000 105,000 150,000 39 x 47 x 86 631 5 KGA060S4B 11.2 13.0 65,000 105,000 150,000 39 x 47 x 86 661 6 KGA072S4B 11.0 11.2 65,000 105,000 150,000 47 x 47 x 86 760 7.5 KGA090S4B 11.0 11.2 105,000 150,000 47 x 47 x 99 865 SHIP WT. [LBS.] 7.5 KGA092S4B/M 11.0 11.8/13.0 130,000 180,000 240,000 47 x 61 x 102 1,052 8.5 KGA102S4B/M 11.0 11.8/13.0 130,000 180,000 240,000 47 x 61 x 102 1,072 10 KGA120S4B/M 11.0 11.8/13.0 130,000 180,000 240,000 47 x 61 x 102 1,112 12.5 KGA150S4B 11.0 11.4/12.0 130,000 180,000 240,000 47 x 61 x 102 1,202 15 KGA180S4B 10.8 11.0 260,000 360,000 480,000 55 x 92 x 108 2,055 17.5 KGA210S4B 10.8 11.0 260,000 360,000 480,000 55 x 92 x 108 2,200 20 KGA240S4B 10.8 11.0 260,000 360,000 480,000 55 x 92 x 133 2,295 25 KGA300S4B 10.0 9.9 260,000 360,000 480,000 55 x 92 x 133 2,375 KW Range* 2 KCA024S4D 11.4 13.0 7.5 10.0 39 x 47 x 86 555 2.5 KCA030S4D 11.2 13.0 7.5 10.0 39 x 47 x 86 557 3 KCA036S4B 10.7 13.0 7.5 15.0 39 x 47 x 86 558 4 KCA048S4B 11.0 13.0 7.5 15.0 39 x 47 x 86 595 5 KCA060S4B 11.2 13.0 7.5 15.0 22.5 39 x 47 x 86 625 6 KCA072S4B 11.2 11.4 7.5 15.0 22.5 30.0 47 x 47 x 86 724 7.5 KCA090S4B 11.2 11.4 7.5 15.0 22.5 30.0 47 x 47 x 99 827 7.5 KCA092S4B/M 11.2 12.0/13.2 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,052 8.5 KCA102S4B/M 11.2 12.0/13.2 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,072 10 KCA120S4B/M 11.2 12.0/13.2 15.0 22.5 30.0 45.0 60.0 47 x 61 x 102 1,112 12.5 KCA150S4B 11.2 11.6/12.2 15.0 23.0 30.0 45.0 60.0 47 x 61 x 102 1,202 15 KCA180S4B 11.0 11.2 15.0 30.0 45.0 60.0 55 x 92 x 108 2,000 17.5 KCA210S4B 11.0 11.2 15.0 30.0 45.0 60.0 90.0 55 x 92 x 108 2,145 20 KCA240S4B 11.0 11.2 15.0 30.0 45.0 60.0 90.0 55 x 92 x 133 2,240 25 KCA300S4B 10.0 10.1 15.0 30.0 45.0 60.0 90.0 55 x 92 x 133 2,320 47 Cap. HSPF/COP 47 17 Cap. COP 17 2 KHA024S4D 11.2 13.0 24,000 3.4 14,400 2.3 39 x 47 x 86 591 2.5 KHA030S4D 11.3 13.0 29,200 3.5 17,600 2.3 39 x 47 x 86 593 3 KHA036S4B 10.9 13.0 36,400 3.6 22,000 2.3 39 x 47 x 86 595 4 KHA048S4B 10.7 13.0 48,000 3.5 29,500 2.4 39 x 47 x 86 617 5 KHA060S4B 10.9 13.0 60,500 3.6 36,000 2.4 47 x 47 x 86 727 6 KHA072S4B 11.0 11.2 70,000 3.3 40,000 2.25 47 x 47 x 99 810 7.5 KHA092S4B 11.0 11.2 89,000 3.3 53,000 2.25 47 x 61 x 102 1,114 8.5 KHA102S4B 11.0 11.2 100,000 3.3 55,000 2.25 47 x 61 x 102 1,146 10 KHA120S4B 11.0 11.2 116,000 3.3 72,000 2.25 47 x 61 x 102 1,212 12.5 KHA150S4B 10.6 10.7 138,000 3.3 82,000 2.05 47 x 61 x 124 1,412 15 KHA180S4B 10.6 10.7 178,000 3.2 104,000 2.05 55 x 92 x 130 2,100 20 KHA240S4B 10.6 10.7 220,000 3.2 128,000 2.05 55 x 92 x 130 2,250 Certified in accordance with the USE certification program which is based on ARI Standard 210/240: 95ºF outdoor air temperature and 80ºF db/67ºf wb entering evaporator coil air. Certified in accordance with the ULE certification program which is based on ARI standard 340/360: 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Direct-drive blower motors available for 2- to 5-ton models. *Nominal electric heat capacities are rated at 240V, 480V and 600V. ** Heating CFM for gas models varies dependent upon heat option selected. Minimum heating CFM for heat pumps does not include supplemental electric heat. Note: Due to Lennox ongoing commitment to quality, all specifications, ratings and dimensions are subject to change.

Solutions for customized comfort Don t just choose a Lennox product choose a Lennox Commercial Comfort System. These complete packages of HVAC solutions provide tools to create a healthy and comfortable environment. Packaged Units Energence Rooftop Units Strategos Rooftop Units Landmark Rooftop Units Raider Rooftop Units Commercial Controls Systems Integration Solutions Commercial Thermostats L Connection Network Solar Ready SunSource Commercial Energy System Indoor Air Quality Humiditrol Dehumidification System Demand Control Ventilation Air Filters UVC Lamps Split Systems S-Class Air Conditioners/Heat Pumps T-Class Air Conditioners/Heat Pumps Air Handlers Indoor Coils Heating Unit Heaters Duct Furnaces Furnaces Visit us at www.lennox.com, or contact us at 1-877-726-0024. 2012 Lennox Industries Inc. For a complete list of the registered and common law trademarks owned by Lennox Industries Inc., please visit www.lennox.com. Litho U.S.A. 36W72 11/12 PC72167