Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

Similar documents
Abrasion Resistance of Fluoropolymer and polyester Coatings

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Fire Test Reports for Interpon D Powder Coatings

SIGMADEK, LTD. FIRE TEST REPORT

BCTC CARPET TECHNICAL CENTRE

Üntel is ready for CPR

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Classification of Fire Performance of Wall and Ceiling Lining Materials

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Loss Prevention Standard

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

MetaAlloy CI Primer Repair System

ISO INTERNATIONAL STANDARD

Test Report: ICL/CR15/11/087

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Construction Products Regulation (CPR) and cables. British Cables Association Guidance to Specifiers

Shipboard incinerators with capacities up to 4000 kw

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

FUNDERMAX GMBH FIRE TEST REPORT

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

BS 476: Part 6: 1989+A1:2009

Are Your Kitchen Hood Filters Compliant?

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

2 Examination of Cladding Panels (Laboratory)

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Australian/New Zealand Standard

2.2 Factors in design

BS 5839: Part THE CHANGES

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of electrical installations in special situations

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

YOUR GUIDE TO UNDERSTANDING CPR

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Australian/New Zealand Standard

BS EN : 2001 & IEC :2000

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN ISO : 2010

ISO INTERNATIONAL STANDARD

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Harmonisation and equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study

Victorian Solar Hot Water Rebate Guidelines for Applicants and Suppliers (Updated 4 September 2009)

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

BS 476: Part 6: 1989+A1:2009

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

The Passive Fire Protection Handbook

A guide to the changes of Amendment 1 of BS

FIRE SAFE NOTICE BOARDS Education Buildings SPECIFYING FIRE RATED NOTICE BOARDS. Issue #1

Smoke detection in hazardous areas:

Charcon British Standard kerb

Fire Performance of Translucent Systems

Record of Amendments. Version Date Amendment Section/page affected

ISO INTERNATIONAL STANDARD

Australian/New Zealand Standard

SOUTH AFRICAN NATIONAL STANDARD

BS EN ISO : 2010

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

The Passive Fire Protection Handbook

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Intumescents & Accessories for use in Consumer Units for Domestic Household and other Premises. Amendment No. 3 BS 7671

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Fire Retardant Resins PERFORMANCE THAT TAKES THE HEAT

RELIGIOUS, FESTIVAL & OTHER DECORATIONS - FIRE SAFETY GUIDANCE

CLASSIFICATION REPORT

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

A guide to the changes between BS 8418:2010 and BS 8418:2015

AXIOM L CANOPY Installation Guide

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

RIBA response to the second phase of the Independent Review of Building Regulations and Fire Safety

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

Transcription:

Guidance Note 3. Fire Propagation and flame Flame Spread in in Powder Coatings Abrasion Resistance of Fluoropolymer and polyester Coatings

British Standards British Standard 476 refers to fire tests on building materials and structures. The parts of this standard that are of most relevance to powder coatings are; Part 6 - Fire Propagation The result of this test is a fire propagation index. It is a measure of the contribution to fire growth made by an essentially flat surface. The results of the test are specific to the test specimen i.e. the product on that particular substrate in the form in which it was tested. Therefore it cannot be used as a method for assessing the product in all situations. Part 7 - Surface Spread of Flame This is a method of measuring flame spread along the surface of a specimen. Again the results of the test are specific to the test specimen i.e. the product on that particular substrate in the form in which it was tested. Therefore it can not be used as a method for assessing the product in all situations. As defined in the UK Building Regulations 2000 - Fire Safety Approved Document B, the highest product performance classification for wall or ceiling linings is Class 0. This is achieved if a material; (a) Achieves a class 1 rating in BS476 Part 7, and (b) Achieves a fire propagation index of not more than 12 and sub-index of not more than 6 in BS476 Part 6. Interpon D1000 series and D2000 Series, including D2000 Brilliance, have been tested to BS476 Parts 6 and 7 and have met the criteria for Class 0 building regulation approval. Test reports available on request. Further Information: Fire Tests on Building Materials and Structures BS476 - British Standard Institute Building Regulations Approved Document B2 Fire Safety, Internal Fire Spread (Linings) - DETR

US Standards ASTM E1321 Ignition and Flame Spread Testing - Interpon D3000 Flame Spread Test Flame front position Arrival time at sample 50mm 155-215s 100mm 200-262s Flame front velocity: 0.34-0.45mm/s Ignition Test Surface ignition temperature 495 C Tests conducted by VTEC Laboratories inc. The specimen did not burn enough to generate data for final data analysis European Standard Fire testing and reports issued by external independent accredited laboratories certify that our range of Polyester product in several colours, are classified in agreement with the European Norm EN 13501-1 as: Interpon Polyester A2 -s1, d0 Interpon Polyester A2 L -s1, d0 This result means: A2 L Non combustible - No contribution to fire (Flammable under 20s) s1 Expression for the Smoke Emission in: walls, ceilings and floors d0 Expression for release of droplets / particles in: walls, ceilings and floors The results are considered increasingly unfavourable from A1 to E for the principal index, as well as for the release of smoke (s1, s2 o s3) and flaming droplets/ particles (d0, d1 o d2)

Australian Standard AS/NZS 1530.3:1999 SIMULTANEOUS DETERMINATION OF IGNITABILITY, FLAME PROPAGATION, HEAT RELEASE AND SMOKE RELEASE Interpon powder coatings achieved an index score of 0 for Ignitability, Spread of flame, Heat Evolved, and Smoke Developed.

AkzoNobel Powder Coatings Issue 6, May 2016 IMPORTANT NOTE The information in this guidance note is not intended to be exhaustive and is based on the present state of our knowledge and on current laws: any person using an AkzoNobel product for any purpose other than that specifically recommended in the technical data sheet without first obtaining written confirmation from us as to the suitability of the product for the intended purpose does so at his own risk. It is always the responsibility of the user to take all necessary steps to fulfill the demands set out in the local rules and legislation. Always read the Material Data Sheet and the Technical Data Sheet for AkzoNobel products if available. All advice we give or any statement made about our product by us (whether in this guidance note or otherwise) is correct to the best of our knowledge but we have no control over the quality or the condition of the substrate or the many factors affecting the use and application of the product. Therefore, unless we specifically agree in writing otherwise, we do not accept any liability whatsoever for the performance of the product or for any loss or damage arising out of the use of the product. All products supplied and technical advice given are subject to our standard terms and conditions of sale. You should request a copy of this document and review it carefully. The information contained in this guidance note is subject to modification from time to time in the light of experience and our policy of continuous development. It is the user s responsibility to verify that this guidance note is current prior to using the product. Brand names mentioned in this data sheet are trademarks of or are licensed to AkzoNobel.

Page 1 of 1 Product Registration Certificate Printed on: 16 Sep 2013 Registration No. 1902 Title Interpon D1036 Status Authorised For Use Supersedes ProductID N/A Superseded By ProductID N/A Date Authorised for Use 19 Sep 2012 Primary Use Architectural grade powder coating for general use within stations, above and below ground. Additional Info/KeyWords Akzo Powder Coatings Ltd, Stoneygate Lane, Felling, Tyne & Wear, NE10 0JY. Tel: 0191 469 6111. www.interpon.co.uk Complies with LU Standard 1-085 'Fire Safety Performance of Materials'. Potential use includes cladding and metal ceilings. Classification Hierarchy Premises Manufactured By Akzo Nobel Powder Coatings Ltd Requirements ReqID Requirement Status Trial No records to display. Conditions Description No records to display. Linked To ReqID Evidence EvidenceText EvidenceType FileName Linked To ReqID Technical Data Sheet - Gloss User Guide InterponD1036GLOSS.pdf Technical Data Sheet - Satin User Guide InterponD1036SATIN.pdf Technical Data Sheet - Matt User Guide InterponD1036Matt_30_Issue6Aug2011.pdf British Board of Agrement Certification Specification BBAInterponD1036Dec07.pdf Reminder: Products must not be publicised as being authorised for use by London Underground Limited (LUL) without also stating any conditions or limitations that apply, nor may any LUL intellectual property rights (such as the roundel trademark) be used in any such publicity. LUL reserves the right to withdraw authorisation of any product publicised in breach of this reminder. Refer to Web site www.luapr.co.uk to check current status, download attachments and for details of other products. MAYOR OF LONDON http://www.lu-apr.co.uk/pages/operational/certificatetoprint.aspx 16/09/2013