Burners Flares Incinerators Vapor Combustion

Similar documents
Amec Foster Wheeler- Fired Heater Division

Coker Heaters Performance Improvement. Don Tran LyondellBasell, Houston Refinery & Ashutosh Garg Furnace Improvements Sugar Land, TX

Zeeco, Inc. Doc. No Tulsa, Ok Cover Page GLSF-14 Free-Jet and RWSF-4 Radiant Wall Burners. Range Fuels Soperton Plant, LLC

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

LOW-NOX BURNER RETROFIT CHALLENGE

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

OPERATING AND MAINTENANCE MANUAL

Fired Heater Flooding

Columbia Boiler Company

THE WORLD S FIRST FLAMELESS CRUDE HEATER

Zeeco recently had the opportunity

Type CG Series Forced Draft Gas Burner

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

The World s First Flameless Crude Heater

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Overview of Gas Range Types

NMC Nozzle Mix Gas/Oil Combination Burners

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

PROFIRE -E SERIES BURNERS

HYDROCARBONENGINEERING June June 2015

Fired Heaters Key to Efficient Operation of Refineries and Petrochemicals

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Design and Application Details

NMG NOZZLE MIX GAS BURNERS

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

PETRO-CANADA OIL AND GAS. FIRE-TUBE IMMERSION HEATER OPTIMIZATION PROGRAM & Field Heater Audit Program

Improving Fired Heaters Reliability using Inclined Firing Technology

Revamp Fired Heaters to Increase Capacity Use these guidelines to ensure a successful project

Solution builder. in energy management.

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

B - BEST O - ORIGINAL. R - Renown. N - Name. I n H e a t e r s

INSTALLATION AND OPERATING MANUAL

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

FLAT FLAME AND EXCESS AIR BURNERS

Flameless Technology Demonstration Heater

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Combustion Sources of Carbon Monoxide. Carbon Monoxide Repairs. Topics Addressed in Session. Why CO can be Harmful Inhalation Time and Symptoms

Introduction. Craig Hale National Sales Manager. Advanced Radiant Systems, Inc. Fishers, IN. Signature Flight Support

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

G315/6 Cast Iron Boiler

L O S S C O N T R O L

PVE SERIES POWER VENTER SYSTEM MANUAL

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

QHT Manual for: SU-2A Gas Burner

POWER VENTER. Model: PVE Series

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

G315/5 Cast Iron Boiler

Originators of the Flexible Water Tube design

G515/7 Cast Iron Boiler

DIVISION FINNED WATER-TUBE WATER HEATERS

Water Spray Systems: NFPA 15

Power Flame Incorporated

USER S INFORMATION MANUAL

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

G615/11 Cast Iron Boiler

Copyright 2009 Power Flame Incorporated

05/14/2012 BOILER TUNE UPS & REPLACEMENTS PRESENTATION BOILER BASICS FOR LARGE INDUSTRIAL FACILITIES. Mark Bergum, P.E.

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

DELTA-TE III. Nozzle-mix line burner

12711 TOWNEPARK WAY / LOUISVILLE, KY / / FAX

Intelligent Heating for Your Home

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Shell Martinez Refinery Callidus CUBL Burners

GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO.

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

FINNED WATER-TUBE POOL HEATERS

The Baked Food Company

Refining and Petrochemical Heater trouble shooting

PACKAGED METALLIC BURNERS

INSTALLATION AND OPERATING MANUAL

High efficiency, cast-iron gas boiler

DIVISION FINNED WATER-TUBE BOILERS

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Boiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX

WATER-TUBE POOL HEATERS

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016

SECTION HEATING BOILERS

G215 G315 Cast Iron Residential Boilers

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

TUBE-O-THERM Low Temperature Gas Burners

Improving the Performance and Reliability of Fired Heaters and Boilers

Originators of the Flexible Water Tube design

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

ECLIPSE INFORMATION GUIDE

UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER

Transcription:

Burners Flares Incinerators Vapor Combustion

Lower Emissions & Improve Equipment Life AIChE May 20 th, 2005 Scott D. Reed 2

Heater Components Stack & Damper Convection Section Radiant Section Burners Burner

Heater Draft Profile Draft = 0 wc Convection Section Draft = -0.6 wc Draft = -0.1 wc ROT = 0.10 wc / ft of radiant box height Radiant Section Burner Draft = -0.4 wc

Draft Measurement Draft Gauges The inclined tube type manometer is the most common gauge used for draft measurement. Vent Draft Connection Level Bleeder

Draft Target Heater designer / Manufacturer determines the target draft for each heater design Typically this target is 0.05 0.10 wc at the arch

Draft Implications Draft too high Elevated stack temperatures Tramp air ingress Draft too low Firebox damage Safety for Ops personnel

Emission Measurement Locations Convection Section Draft Measurement CO & NOx Measurement O2 Measurement Radiant Section Burner

Heater Inspection Flame Stability / pattern Refractory condition / color TMT s / tube hanger color Burner gas tips / tile condition

Combustion vs. Thermal Efficiency Combustion Efficiency % of completion of the combustion rxn Thermal Efficiency Function of Stack temp and Excess Air

% O2 vs Excess Air 1% O2 = 5% excess air 2% O2 = 10% excess air 3% O2 = 15% excess air 4% O2 = 20% excess air 5% O2 = 25% excess air

Excess Air Target 1-2% O2 target range (5 10% excess air) for gas fired heaters However this depends on: fuel gas composition mechanical condition of equipment heater service / swings

Burner / Heater Adjustment When making adjustments to the heater a visual check of burner flame quality should be made and the heater allowed to reach new equilibrium prior to any further adjustment.

Excess Air adjustment Stack damper is for heater draft adjustment Burner register is for excess air adjustment

Natural Draft Heater Adjustment Flow Chart Target Draft Start Check Draft Target O 2 High (1) Low (2) High (3) Check O 2 On Target (3) Low (3) On Target High (3) Check O 2 On Target (3) Low (3) Close Damper Close Damper Open Air Registers Close Air Register Open Damper Open Damper Return to Start Return to Start High Close Air Registers Return to Start (1) High Draft means fire box press. more neg. than target. (2) Low Draft - means fire box press. more pos. than target. (3) Low or High O 2 means O 2 is above or below target. Check O 2 On Target Good Operation Low Open Air Registers Return to Start

Fuel Efficiency 28 26 Stack Temperature 1400 F 1200 F 24 22 1000 F % FUEL LOSS 20 18 16 14 12 % O 2 to % Excess Air Ratio 800 F 0 20 40 % EXCESS AIR IN FLUE GAS 10 600 F 8 400 F 60 6 4 80 2 0 0 2 4 6 8 10 12 % OXYGEN IN FLUE GAS 100

Excess Air reduction savings 40MM Btu/hr fired htr w/ 800F stack temp @ 7.5% O2 Excess air reduced to 3% O2 ~5% of the fuel is used to heat ambient air to 800F ~$6/MMBtu fuel cost ~$200,000 in fuel savings / yr

Excess Air Automated Control

Excess Air reduction savings 40MM Btu/hr fired htr w/ 800F stack temp @ 7.5% O2 Excess air reduced to 3% O2 ~5% of the fuel is used to heat ambient air to 800F ~$6/MMBtu fuel cost ~$200,000 in fuel savings / yr ~$15,000 for jackshaft & actuator

Tramp Air Leakage Sources Sight Ports Convection section flanges / header box Explosion doors Open air registers on burners Out of service

Tramp air leakage Tramp air leakage

Tramp Air Leakage remedies Sight Port Covers High temp sealant caulk close air registers on burners Out of service

Tramp Air reduction savings Sight port 4 X 6 800F stack temp @ 0.50 wc draft loss ~2300 #/hr ambient air being heated to 800F ~$6/MMBtu fuel cost ~$21,400 in fuel loss / yr

Heater Sight Port cover High temperature glass covered heater sight port Cost ~$500 Savings ~$20,000

Tramp Air -- NOx Impact Tramp air leakage (as % of total air flow) vs. NOx emissions ~10% air leakage increases NOx emissions 15-20% range* ~20% air leakage increases NOx emissions 30-40% range* (*depends on where the tramp air is introduced)

Burner Inspection Gas tips / risers Burner tile Pilot tip and mixer Air register / damper

Consistency is the goal

Consistency is the goal

Burner Maintenance

Burner Maintenance

Burner Maintenance

Burner maintenance Fuel Pressure Vs. Heat Release Curve

Tile inspection Inspect the tile for cracks and missing pieces. Replace the tile if any of the pieces are broken or missing. Missing tile section

Pilot Inspection Inspect the pilot tip for any damage. The pilot air door for operability and the pilot orifice for plugging.

Pilot Inspection Pilot shield should normally glow cherry red, shields are consumable parts.

Air damper / register inspection Ensure that the air control damper or register operates freely and is properly engaged.

Diffuser cone inspection Inspect diffuser cones or swirlers for damage. Replace if damaged.

Gas tip inspection Example of a gas tip which has failed due to coking of condensed heavy or unsaturated hydrocarbons inside the tip.

Gas tip Inspection Check that orifice sizes match the sizes shown on the drawing, when any orifice becomes one drill size larger than specified, replace the orifice/tip.

Gas tip port orientation 5 degree Port Orientation 15 degree Port Orientation

Gas Riser inspection gas riser failure due to exposure to radiant firebox

Gas Tip / Riser Fouling problems it creates

How Zeeco can Help Onsite burner / maintenance school tailored around the burners at your plant Heater survey / inspection report Pre-turnaround inspection low cost spares / refurbished Burner and components (rather than complete replacements)

Spares savings For Typical sized GC refinery, Zeeco can supply equal or better quality combustion spares at about ½ what you are currently paying For typical refinery this amounts to about $200,000 per year savings just in spares

Summary Lower emissions via heater draft control, tramp air control, excess air control Improve equipment life via active Look & Act plan, clean, refurbish, replace components as needed. Get burner vendor as a maintenance partner

Zeeco Field Support NOT JUST EQUAL BETTER