Low Smoke Zero Halogen

Similar documents
CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

Catalogue Telecommunication Cables INTRODUCCIÓN

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Catalogue Power Cables

Catalogue. Instrumentation & Control Cables

PRODUCT CATALOGUE Norröna

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Flexible Power Cable DLO

DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0399 Edition March 2016

Shipboard & Offshore Cables

Telecommunication Cables

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Caledonian Flame Retardant Coaxial Cables

1.1 Preferred Manufacturers are manufacturers of products that have worked well for the University on past projects.

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Power Control Cable Iec

High Performance LSZH Fire Resistant Cable

Caledonian Fire resistant Coaxial Cables

Caledonian fire Resistant signal & Data cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

QUALITY THROUGH EXPERIENCE

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Total Fire Solutions. Includes BS 8519 and the updated BS :

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

FIRE RESISTANT CABLES

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

TYPE APPROVAL CERTIFICATE

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

CONNECTION SYSTEMS TRANSIT APPLICATIONS

BS /1000V XLPE Insulation LSZH Sheath Cables

Union County Vocational - Technical Schools Scotch Plains, New Jersey

ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES

(Notices) EUROPEAN COMMISSION

Tratos Railway Cables

Compact Module. Category 6A FTP Cabling System 1.1

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

SAS Security and Alarm Safety Cables

SECTION ELECTRICAL GENERAL PROVISIONS

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

fire resistant cables

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Wires, Cables, Cords and Adhesive Tapes

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

The Quality Connection. BETAflam Fire Resistant Safety Cables

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

OIL & GAS INDUSTRY OTHER INDUSTRIES

Sensor and transducer cables

IEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas

5. Identification products.

DNVGL-CP-0402 Edition February 2016

FIRE RESISTANT CABLES FP300

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Comtran Cable. Hub-LINK Cables for Transit Applications

Photovoltaic Cables EN H1Z2Z2-K

Havells Fire Survival Cables

CABLES FOR ALARM AND SAFETY SYSTEMS

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co

North American Cable Glands

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Lloyd s Register Type Approval System Test Specification Number 3

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

F1202 TRACE HEATING. Road & Ramp

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Firecel Safety Cables

Cablosam Tapes for Fire-Resistant Cables

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

STANDARDS INSTALLATION. Certificate No 077m

Evolution of Cable Fire Safety Standards in Australia

Introduction.

ROLLING STOCKS Cables ELECRAIL

Cable technology for highest safety requirements

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

LV FIRE RESISTANT CABLES

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

INTERNATIONAL STANDARD

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

Low Smoke Zero Halogen Cable for Marine Applications 621 Time Saver Avenue Harahan, LA 70123 Call Toll Free: (888) 326-5174 Email: marine@summit.com Marine Division summit.com/marine

Power and Control Cable M2XH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. EC 60228 Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Separator: Separating foil or halogen free, bedding compound on request. 4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray. 4 3 2 1 Production and Test Standards Construction...IEC 60092 / 353 Tests and Material...IEC 60092 / 350-351-359 Flame Retardation...IEC 60332 / 1, IEC 60332 / 3 Cat A Halogen Content...IEC 60754 / 1-2 Smoke Density...IEC 61034 / 1-2 (DIN EN 50268 / 1-2) Working Temperature...-40 C / +90 C Min. Bending Radius (Fixed)...6 x Overall Diameter Rated Voltage...0.6 / 1 kv Test Voltage...3.5 kv Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 2 (888) 326-5174

Product Specifications M2XH Power and Control Cable Part # Sizes mm 2 Designation O.D. inches 1758026 2 x 1.5 D-3 0.33 1758027 2 x 2.5 D-4 0.37 1758028 2 x 4 D-6 0.41 1758029 2 x 6 D-10 0.46 3636723 2 x 10 D-16 0.53 1963121 2 x 16 D-26 0.62 1963122 2 x 25 D-41 0.82 1758030 3 x 1.5 T-3 0.35 1758031 3 x 2.5 T-4 0.39 1758032 3 x 4 T-6 0.44 1758033 3 x 6 T-10 0.49 1758034 3 x 10 T-16 0.57 1758035 3 x 16 T-26 0.67 1758036 3 x 25 T-41 0.88 1758037 3 x 35 T-66 0.98 1758038 3 x 50 T-106 1.12 1758039 3 x 70 T-133 1.32 1758040 3 x 95 T-212 1.48 1758041 3 x 120 T-250 1.66 1758042 3 x 150 T-300 1.83 1758043 3 x 185 T-400 2.04 1859977 3 x 240 T-500 2.30 1758044 4 x 1.5 F-3 0.39 1758045 4 x 2.5 F-4 0.43 1758046 4 x 4 F-6 0.49 1758047 4 x 6 F-10 0.54 Part # Sizes mm 2 Designation O.D. inches 1758048 4 x 10 F-16 0.63 1758049 4 x 16 F-26 0.73 1758050 4 x 25 F-41 0.97 1758051 4 x 35 F-66 1.08 1758052 4 x 50 F-106 1.26 1758053 4 x 70 F-133 1.46 1758054 4 x 95 F-212 1.67 1758055 4 x 120 F-250 1.85 1758069 4 x 150 F-300 2.04 1758070 4 x 185 F-400 2.30 1758056 7 x 1.5 M-7-3 0.46 1758057 7 x 2.5 M-7-4 0.51 3636722 7 x 4 M-7-6 0.54 1758058 10 x 1.5 M-10-3 0.59 1758059 10 x 2.5 M-10-4 0.66 1971917 12 x 4 M-12-6 0.79 1758060 14 x 1.5 M-14-3 0.64 1758061 14 x 2.5 M-14-4 0.71 3636721 16 x 2.5 M-16-4 0.76 1758062 20 x 1.5 M-20-3 0.71 1758063 20 x 2.5 M-20-4 0.80 1859982 24 x 1.5 M-24-3 0.84 3683670 24 x 2.5 M-24-4 0.94 1758064 30 x 1.5 M-30-3 0.90 1758065 30 x 2.5 M-30-4 1.04 1990092 37 x 1.5 M-37-3 0.97 summit.com/marine 3

Shielded Control Cable M2XCH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC 60228 Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Shield: Electrolytic, copper-braided shield (90% coverage). M2XCH (EMC) type is wrapped by a copper tape in addition to this shield (100% coverage). 4 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray. 2 1 4 3 Production and Test Standards Construction... IEC 60092 / 353 Tests and Material... IEC 60092 / 350-351-359 Flame Retardation... IEC 60332 / 1, IEC 60332 / 3 Cat A Halogen Content... IEC 60754 / 1-2 Smoke Density... IEC 61034 / 1-2 (DIN EN 50268 / 1-2) Shielding Effectiveness (for EMC type)... DIN EN 50147-1 Working Temperature... -40 C / +90 C Min. Bending Radius (Fixed)... 8 x Overall Diameter Rated Voltage... 0.6 / 1 kv Test Voltage... 3.5 kv Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 4 (888) 326-5174

Product Specifications M2XCH Shielded Control Cable Part # Sizes mm 2 Designation O.D. inches 1826901 3 x 2.5 TS-4 0.43 3636718 3 x 4 TS-6 0.48 3636719 4 x 1.5 FS-3 0.43 1826903 4 x 2.5 FS4 0.47 1826902 4 x 4 FS6 0.57 1983712 4 x 25 FS41 1.04 1758016 7 x 1.5 MS-7-3 0.50 1758017 7 x 2.5 MS-7-4 0.57 Part # Sizes mm 2 Designation O.D. inches 1758019 10 x 2.5 MS-10-4 0.71 1758020 14 x 1.5 MS-14-3 0.70 1758021 14 x 2.5 MS-14-4 0.77 3636720 16 x 1.5 MS-16-3 0.74 1758022 20 x 1.5 MS-20-3 0.78 1758023 20 x 2.5 MS-20-4 0.85 1758024 30 x 1.5 MS-30-3 0.95 1758025 30 x 2.5 MS-30-4 1.06 1758018 10 x 1.5 MS-10-3 0.64 summit.com/marine 5

VFD Cable M2XCH-VFD Cable Structure 1 - Conductor: Circular stranded annealed electrolytic copper conductor (Class 5 according to IEC 60228) 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). 3 - Filler and Bedding: Halogen-free, flame-retardant, thermoplastic polyolefin-based compound in between the inner sheath and the insulation of the conductor. (HM4/SHF1 - according to IEC 60092-359/360) 4 - Screen: CU/PETP tape (100% coverage). Electrolytic copper braided screen (90% coverage density). 5 - Outer Sheath: Halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1 - according to IEC 60092-359/360) 4 2 1 5 3 Production and Test Standards Construction... IEC 60092-353 & IEC 60092-360/350 Conductor Material... IEC 60228 Insulation Material... IEC 60092-351 Sheath Material... IEC 60092-360 Flame Retardance... IEC 60332-1 Halogen-Free Properties... IEC 60754-1 & IEC 60754-2 Low-Smoke Emission... IEC 61034-1 & IEC 61034-2 Tests... IEC 60092-353 Choice & Installation... IEC 60092-352 Min. Bending Radius (Fixed)... 6 x Overall Diameter Min. Bending Radius (during installation)... 8 x Overall Diameter Application Used as fixed installation cables in various electromechanical and electronic equipment of marine vehicles. Usable in all conditions of a marine environment such as dry, wet or oily locations. 6 (888) 326-5174

Product Specifications M2XCH-VFD VFD Cable Part # Sizes (mm 2 ) Designation O.D. (inches) 3683672 3 x 16 + 3x6 T-26 VFD 0.90 3683675 3 x 25 + 3x6 T-41 VFD 1.02 * 3 x 35 + 3x6 T-66 VFD 1.12 3695884 3 x 50 + 3x10 T-106 VFD 1.31 * 3 x 70 + 3x16 T-133 VFD 1.45 3695885 3 x 95 + 3x16 T-212 VFD 1.63 * 3 x 120 + 3x25 T-250 VFD 1.86 * 3 x 150 + 3x25 T-300 VFD 2.02 * 3 x 185 + 3x35 T-400 VFD 2.16 * 3 x 240 + 3x50 T-500 VFD 2.41 *Available upon request. Contact Summit s Marine Division at (888) 326-5174 for more details. summit.com/marine 7

Overall Shielded Instrumentation Cable FM2XAH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC 60228 Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs; pairs laid up concentrically. 3 - Separator: Separating foil below shield. 4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below shield. 5 - Shield: Aluminum tape shield (100% coverage). 6 - Separator: Separating foil above shield. 7 - Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4 / SHF1) - HD 604. Color: Gray. 7 4 1 Production and Test Standards 6 5 Construction... IEC 60092 / 375-376 Tests and Material... IEC 60092 / 350-351-359 Flame Retardation... IEC 60332 / 1, IEC 60332 / 3 Cat A Halogen Content... IEC 60754 / 1-2 Smoke Density... IEC 61034 / 1-2 (DIN EN 50268 / 1-2) Working Temperature... -40 C / +90 C Min. Bending Radius (Fixed)... 8 x Overall Diameter Rated Voltage... 60 / 250 V Test Voltage... 1.5 kv Application Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms. 3 2 8 (888) 326-5174

Product Specifications FM2XAH Overall Shielded Instrumentation Cable Part # Sizes mm2 Designation O.D. inches 1758013 1 x 2 x 1.5 TPS16-1P 0.37 1758014 1 x 2 x.75 TPS18-1P 0.31 1758015 1 x 2 x.50 TPS20-1P 0.28 Part # Sizes mm2 Designation O.D. inches 1826904 1 x 2 x 2.5 TPS14-1 0.33 1758068 1 x 3 x 1.5 TTS16-1 0.39 3636717 1 x 3 x 2.5 TTS14-1 0.37 summit.com/marine 9

Individually and Overall Shielded Instrumentation Cable FM2XAAH Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire. IEC 60228 Class 5 (Class 2 and/or tinned on request). 2- Insulation: Low smoke, halogen free, cross linked, polyethylene compound (XLPE). Layup: Cores laid up in pairs/triads; pairs/triads laid up concentrically. 3 - Separator: Separating foil over pairs/triads 4 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire along each pair/triad. 5 - Individual Shield: Aluminum tape shield over each pair/triad and drain-wire bunch (100% coverage). 6 - Separator: Separating foil above shield or inner sheath (on request). 7 - Drain Wire: Electrolytic, tinned, stranded, copper drain wire below overall shield. 8 - Overall Shield: Aluminum tape overall shield (100% coverage). 9 - Separator: Separating foil over overall shield. 10 -Outer Sheath: Low smoke, halogen free, flame retardant, thermoplastic, polyolefin-based compound (HM4/SHF1) HD 604. Color: Gray. 3 2 10 1 9 8 6 5 7 4 Production and Test Standards Construction... IEC 60092 / 376 Tests And Material... IEC 60092 / 350-351-359 Flame Retardation... IEC 60332 / 1, IEC 60332 / 3 Cat A Halogen Content... IEC 60754 / 1-2 Smoke Density... IEC 61034 / 1-2 (DIN EN 50268 / 1-2) Working Temperature... -40 C / +90 C Min. Bending Radius (Fixed)... 10 x Overall Diameter Rated Voltage... 60/250 V Test Voltage... 1.5 kv Application Used as control and communication cables in radio, radar and information systems for marine applications. Enables proper transmission of high frequency signals while minimizing environmental electromagnetic interference. Usable in all conditions in marine environment such as dry, wet or oily locations, and inside engine rooms. 10 (888) 326-5174

Product Specifications FM2XAAH Overall Shielded Instrumentation Cable Part # Sizes mm 2 Designation O.D. in inches 3636716 2 x 2 x 2.5 TPS14-2P 0.58 1758001 2 x 2 x 1.5 TPS16-2P 0.61 1758002 2 x 2 x.75 TPS18-2P 0.50 1758003 2 x 2 x.50 TPS20-2P 0.46 1758004 4 x 2 x 1.5 TPS16-4P 0.72 1758005 4 x 2 x.75 TPS18-4P 0.58 1758006 4 x 2 x.50 TPS20-4P 0.54 3317874 5 x 2 x.75 TPS18-5P 0.56 1758007 6 x 2 x 1.5 TSP16-6P 0.87 1758008 6 x 2 x.75 TPS18-6P 0.70 Part # Sizes mm 2 Designation O.D. in inches 1758009 6 x 2 x.50 TPS20-6P 0.65 3683671 7 x 2 x 1.5 TPS16-7P 0.76 3713396 7 x 2 x 2.5 TPS14-7P 0.80 1758010 10 x 2 x 1.5 TPS16-10P 1.08 1758011 10 x 2 x.75 TPS18-10P 0.87 1758012 10 x 2 x.50 TPS20-10P 0.80 1758066 12 x 2 x 1.5 TPS16-12P 1.13 1758067 14 x 2 x 1.5 TPS16-14P 1.24 3636714 15 x 2 x.75 TPS18-15P 0.89 3636715 15 x 2 x 1.5 TPS16-15P 1.10 summit.com/marine 11

Single Insulated Conductor Cable M2X Cable Structure 1 - Conductor: Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and/or tinned on request). 2 - Insulation: Low smoke, halogen free, flame retardant, cross linked, polyolefin compound (HF90). Color: Black (other colors available on request). Double insulation is available on request. 2 1 Production and Test Standards Construction...IEC 60092 / 353 Tests And Material...IEC 60092 / 350-351-359 Flame Retardation...IEC 60332 / 1, IEC 60332 / 3 Cat A Halogen Content...IEC 60754 / 1-2 Smoke Density...IEC 61034 / 1-2 (DIN EN 50268 / 1-2) Working Temperature...-40 C / +90 C Min. Bending Radius (Fixed)...4 x Overall Diameter Rated Voltage...0.6 / 1 kv Test Voltage...3.5 kv Application Used as fixed installation cables in various electromechanical and electronic equipment, including marine switchboards. Usable in all conditions in marine environment, such as dry, wet or oily locations. 12 (888) 326-5174

Product Specifications M2X Single Insulated Conductor Cable Part # Sizes (mm 2 ) Designation O.D. (inches) * 1 x 0.50 S-1 0.08 * 1 x 0.75 S-2 0.09 * 1 x 1.5 S-3 0.12 * 1 x 2.5 S-4 0.13 * 1 x 4 S-6 0.16 1990090 1 x 6 S-10 0.18 * 1 x 10 S-16 0.22 1990091 1 x 16 S-26 0.26 1826895 1 x 25 S-41 0.34 Part # Sizes (mm 2 ) Designation O.D. (inches) 1826896 1 x 35 S-66 0.39 1826897 1 x 50 S-106 0.46 1826898 1 x 70 S-133 0.54 1826899 1 x 95 S-212 0.60 1826900 1 x 120 S-250 0.68 2291899 1 x 150 S-300 0.76 1859983 1 x 185 S-400 0.87 * 1 x 240 S-500 0.98 *Available upon request. Contact Summit s Marine Division at (888) 326-5174 for more details. summit.com/marine 13

Fire Resistant and Flame Retardant Instrumentation and Telecommunication Cable BU(I) (NEK 606 S13) RED Cable Structure 1 - Conductor: Electrolytic, stranded, tinned copper wire. IEC 60228 Class 5 2 - Insulation: Halogen free EPR or halogen free HEPR. (All cable to be IEEE-45 color code.) 3 - Separator: Mica tape over conductor 4 - Lay Up: Cores laid up in pair, pairs laid up concentrically 5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along with every pair/triad. 6 - Screen: Electrolytic copper-backed polyester tape screen (100% coverage) over every pair/triad and drain wire 7 - Outer Sheath: SHF2 (SHF MUD on request). Color: Red. 7 6 3 1 2 5 4 Production and Test Standards Construction...NEK 606 S13, IEC 60092 / 376 Tests And Material...IEC 60092 / 350-351-359 Flame Retardation...IEC 60332 / 1, IEC 60332 / 3 Cat A Fire Resistance...IEC 60331 Halogen Content...IEC 60754 / 1-2 Smoke Density...IEC 61034 / 1-2 (DIN EN 50268 / 1-2) Working Temperature...-40 C / +90 C Min. Bending Radius (Fixed)...8x Overall Diameter Rated Voltage...250 V Test Voltage...1.5 kv Application Used as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems. 14 (888) 326-5174

Product Specifications BU(I) (NEK 606 S13) RED Fire Resistant, Flame Retardant Instrumentation and Telecommunications Cable Part # Sizes (mm 2 ) Designation O.D. in inches 3067241 1 x 2x 1.5 BU TPS 16-1 0.34 3208373 2 x 2 x 1.5 BU TPS 16-2 0.57 summit.com/marine 15

Fire Resistant and Flame Retardant Power Cable BU (NEK 606 P17) RED Cable Structure 1 - Conductor: -Conductor: Electrolytic, stranded, tinned copper wire. IEC 60228 Class 5. 2 - Insulation: Halogen free EPR. (All cable to be IEEE-45 color code.) 3 - Separator: Mica tape over conductor 4 - Outer Sheath: SHF2. Color: Red. 4 2 3 1 Production and Test Standards Construction...NEK 606 P17, IEC 60092 / 353 Tests and Material...IEC 60092 / 350-351-359 Flame Retardation...IEC 60332 / 1, IEC 60332 / 3 Cat A Fire Resistance...IEC 60331 Halogen Content...IEC 60754 / 1-2 Smoke Density...IEC 61034 / 1-2 (DIN EN 50268 / 1-2) Working Temperature...-40 C / +90 C Min. Bending Radius (Fixed)...7x Overall Diameter Rated Voltage...0.6/1 kv Test Voltage...3.5 kv Application Used as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems. 16 (888) 326-5174

Product Specifications BU (NEK 606 P17) Fire Resistant and Flame Retardant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) 3067247 7 x 1.5 BU 16/7C 0.60 3067248 19 x 1.5 BU 16/19C 0.96 3067245 3 x 2.5 BU 14/3C 0.49 3208372 4 x 2.5 BU 14/4C 0.54 3331357 7 x 2.5 BU 14/7C 0.66 Part # Sizes (mm 2 ) Designation O.D. (inches) 3067246 10 x 2.5 BU 14/10C 0.81 3067244 2 x 6 BU 10/2C 0.55 3067243 3 x 6 BU 10/3C 0.59 3067249 4 x 16 BU 6/4C 0.85 3067242 3 x 25 BU 4/4C 0.93 summit.com/marine 17

Fire Resistant Instrumentation and Telecommunication Cable BFOU(I) (NEK 606 S3/S7) Cable Structure 1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC 60228 Class 2 (Class 5 on request). 2 - Separator: Mica tape over conductor 3 - Insulation: Halogen free EPR or Halogen free HEPR 4 - Layup: Cores laid up in pairs/triads, pairs/triads laid up concentrically. 5 - Drain Wire: Electrolytic, stranded, tinned copper drain wire along witp every pair/triad 6 - Screen: Electrolytic copper backed polyester tape screen (100% coverage) over every pair/triad and drain wire. 7 - Bedding: Halogen free compound. 8 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ). 9 - Outer Sheath: SHF MUD 8 7 6 3 2 1 9 5 4 Production and Test Standards Construction...NEK 606 S3/S7, IEC 60092/376 Tests And Material...IEC 60092 /350-351-359 Flame Retardation...IEC 60332 /1, IEC 60332 / 3 Cat A Fire Resistance...IEC 60331 Halogen Content...IEC 60754 / 1-2 Smoke Density...IEC 61034 / 1-2 ( DIN EN 50268/1-2) Mud Resistance...IEC 60092 / 359 Working Temperature...-40 C / +90 C Min. Bending Radius (Fixed)...10 x Overall Diameter Rated Voltage...250V Test Voltage...1.5 kv Application Fixed installation cable for signal and communication. 18 (888) 326-5174

Product Specifications BFOU(I) (NEK 606 S3/S7) Fire Resistant and Flame Retardant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) 2340970 1 x 2 x 0.75 18/1PR 0.46 2340973 2 x 2 x 0.75 18/2PR 0.67 2340975 4 x 2 x 0.75 18/4PR 0.77 2340972 1 x 2 x 1.5 16/1PR 0.51 2462582 2 x 2 x 1.5 16/2PR 0.77 2340974 4 x 2 x 1.5 16/4PR 0.89 2340976 7 x 2 x 1.5 16/7PR 1.05 Part # Sizes (mm 2 ) Designation O.D. (inches) 2462580 12 x 2 x 1.5 16/12PR 1.39 3713399 18 x 2 x 1 17/18PR 1.50 2340971 1 x 2 x 1 17/1PR 0.47 3713398 1 x 2 x 2.5 14/1PR 0.53 3713397 6 x 2 x 1.5 16/6PR 1.06 3346589 8 x 2 x 1.5 16/8PR 1.29 summit.com/marine 19

Fire Resistant, Flame Retardant, Mud Resistant Power Cable BFOU (NEK 606 P5/P12) Cable Structure 1 - Conductor: -Electrolytic, stranded, tinned copper wire IEC 60228 Class 2 (Class 5 on request). 2 - Separator: Mica tape over conductor 3 - Insulation: Halogen free EPR or Halogen free HEPR 4 - Bedding: Halogen free compound. 5 - Screen: Electrolytic, tinned copper braided screen ( 90% coverage ). 6 - Outer Sheath: SHF MUD 5 4 6 3 2 1 Production and Test Standards Construction...NEK 606 P5/P12, IEC 60092/353 Tests And MateriaL...IEC 60092 /350-351-359 Flame Retardation...IEC 60332 /1, IEC 60332 / 3 Cat A Fire Resistance...IEC 60331 Halogen Content...IEC 60754 / 1-2 Smoke Density...IEC 61034 / 1-2 ( DIN EN 50268/1-2) Mud Resistance...IEC 60092 / 359 Working Temperature...-40 C / +90 C Min. Bending Radius (Fixed)...8 x Overall Diameter Rated Voltage...0.6/1kV Test Voltage...3.5 kv Application Used as fixed installation cables in various electromechanical and electronic equipment, emergency and critical systems as well as electric distribution and lighting systems. 20 (888) 326-5174

Product Specifications BFOU (NEK 606 P5/P12) Fire Resistant, Flame Retardant, Mud Resistant Power Cable Part # Sizes (mm 2 ) Designation O.D. (inches) 2340960 2 x 2.5 14/2C 0.60 2340961 2 x 4 12/2C 0.65 2340962 2 x 6 10/2C 0.69 3683676 2 x 10 8/2C 0.77 3695886 2 x 50 1/0-2C 1.22 2462583 3 x 1.5 16/3C 0.59 2340963 3 x 2.5 14/3C 0.63 2340964 3 x 4 12/3C 0.68 2340965 3 x 6 10/3C 0.72 2340966 3 x 10 8/3C 0.81 Part # Sizes (mm 2 ) Designation O.D. (inches) 2340967 3 x 16 6/3C 0.91 2340968 3 x 25 4/3C 1.07 2340969 3 x 35 2/3C 1.17 2587543 4 x 2.5 14/4C 0.68 3695887 4 x 4 12/4C 0.74 2343009 7 x 1.5 16/7C 0.74 3683667 7 x 2.5 14/7C 0.80 3683666 10 x 2.5 14/10C 0.95 3683668 16 x 1.5 16/16C 1.12 3683669 20 x 2.5 14/20C 1.21 summit.com/marine 21

Index of Manufacturers In addition to wire and cable, Summit s Marine Division offers a full array of marine electrical products. Audio/Visual Signals Sirens/Bells/Horns/ SignalLights Federal Signal Ballasts Fluorescent/HID Universal Lighting Technologies Banding 316 SS Banding/Buckles Hayata Coated 316 SS Banding/ Buckles Hayata Batteries Industrial AAA/AA/C/D/ Trans/Lantern Rayovac Shipboard Battery Systems / Flooded and Gel Cell Interstate Batteries Cable Glands Marine/Industrial General Duty Gland CMP Hawke Marine / Industrial Class 1, Division 1 & 2 Gland CMP Hawke Cable Termination 250V / 600V / High Voltage Panduit Raychem Thomas & Betts Cable Tray Steel/Aluminum/Marine Rung B-Line by Eaton Niedax Fiberglass Ladder Chalfant Cables / Industrial MV 90/IAC/CLX/Control/ Instrumentation Okonite MV 90/IAC/Control/ Instrumentation/DLO Southwire MV 90/IAC/Control/ Instrumentation/Welding/ DLO AIW Control/Instrumentation/ Fiber Optic/IAC Belden Caulking Silicone GE Plastics USCG Approved Fire Stop Caulk Nelson Chemicals Wire Lube/Cleaners Ideal Lubricants/Cleaners/Solvents CRC Conduit Rigid Galvanized Steel LTV Shamrock Allied Rigid Stainless Steel Gibson Rigid Aluminum Easco Indalex Plastic Coated Plastibond Sealtight Anaconda Flexible Anaconda Conduit Fittings Malleable/Cast/Aluminum/ Steel Crouse-Hinds by Eaton Thomas & Betts Cast Alumimum Crouse-Hinds by Eaton Plastic Coated Plastibond Die Cast Steel Crouse-Hinds by Eaton Conduit Hubs Cast/Steel/Aluminum/SS Crouse-Hinds by Eaton/ Myers Cord Grips Aluminum Gland Type Grip Remke Nylon Gland Type Grip Kleinhuis (Niedax) Crane Control Crane Brake Parts Eaton (Cutler-Hammer) Distribution Gear Panel Boards/ Power Distribution Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Breakers/Shock & Vibration Eaton (Cutler-Hammer) Westinghouse Electricians Supplies Hand Tools Klein Tools Ideal Emergency Lighting Battery Operated Teledyne / Big Beam Chloride Dual Lite Excide Safety Systems Enclosures NEMA/Steel/Aluminum/SS Crouse-Hinds by Eaton Hoffman NEMA/Fiberglass Hoffman Flashlights Mini/D Cell/Lantern Rayovac Bright Star Fuses Glass/250V/600 V/ High Voltage Mersen European Fuses Mersen Grounding Systems Rods and Fittings Cadweld Heat Shrink Tubing Thick/Thin Wall Tubing Panduit 3M Raychem Industrial Lighting Fixtures Incandescent/Fluorescent/ HID Crouse-Hinds by Eaton Phoenix Fluorescent Mobern Industrial Reelites Electrical/Pneumatic Crouse-Hinds by Eaton Instruments Voltage/Amperes/Continuity Fluke Greenlee Labels/Markers/Signs Cable Marking/Safety Marking Panduit Hayata Weidmuller Lamps Incandescent/Fluorescent/ HID Sylvania Miniature Sunray Motor Control MCC/Enclosed Control Eaton (Cutler-Hammer) Westinghouse Military Spec. Navy Control/ Parts Eaton (Cutler-Hammer Navy) Navigation Light Panels USCG Approved Custom Panels J - Box Pin & Sleeve Plug & Receptacle 20-400 Amp/Aluminum Crouse-Hinds by Eaton 20-400 Amp/Nylon Stahl Portable Cord SO/SEOW/Type W/GGC Southwire Portable Cord Sets & Parts Cord Caps/Cord Sets Woodhead Hubbell Portable Lighting Hand Lamps/Class 1 Division 1/Non Hazard Woodhead Portable Cargo Lights Worklights Inc. Safety Switches 30-1200 Amp./General/ Heavy Duty Eaton (Cutler-Hammer) Shipboard Cable Hanger Commercial Cable Hanging Systems R. T. & D Kindorf Victor Commercial and Military Spec Systems R. T. & D Shipboard Communication Integrated Ship Communications Federal Signal Sound Powered Phones Hose McCann Shipboard General Alarm USCG/Navy Approved Brass Bells Hose McCann General Alarm Panels J-Box Shipboard Light Fixtures Incandescent/Fluorescent/ HID/Bronze/Aluminum/SS Phoenix Incandescent/Fluorescent/ HID/Aluminum/SS Aqua Signal L.C. Doane IRL Shipboard Navigation Lights USCG Approved/Single/ Dual Lamp Aqua Signal Shipboard Wiring Devices Switch/Receptacle/Junctions Phoenix Switch/Receptacle & Related Devices Eaton Strut Systems Slotted/Angled B-Line by Eaton Kindorf Tapes Insulating/Bonding/Color Coding 3M Terminal Blocks Din Rail Mount Weidmuller Terminal Tubes 1/2-4 Mil Spec. Nylon Dorn 1/2-4 Brass/Aluminum/ Male/Female Summit Electric Supply Terminals/Lugs Mechanical/Compression Panduit Burndy Thomas & Betts Timers Electronic/Mechanical Timers Tork Transformers Marine Duty Dry Type 25kVa - 500kVa Eaton (Cutler-Hammer) Westinghouse Dry Type and Oil Filled / SS Clad Olsun Oil Filled/SS Clad Van Tran Control Power Eaton (Cutler-Hammer) Machine Tool Acme Transformer Dry Type Distribution Acme Transformer Transit Barriers/MCTs Multi Diameter/Fire/Water/ Gas Rated Roxtec Tyraps Wire Securing Devices, Nylon & SS Panduit Hayata Thomas & Betts Wire Connectors Wire Nuts Ideal Wing Nuts 3M Wiring Devices Switches/Receptacles Cooper Wiring Devices Woodhead 22 (888) 326-5174

CIrcular Mills AWG 3 16 4 14 6 12 10 10 16 8 26 6 41 4 66 2 83 1 106 1/0 133 2/0 168 3/0 212 4/0 250 250MCM 350 350MCM 400 400MCM 500 500MCM Rated Cross-Section at Metric Systems mm 2 0.75 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 Equivalent Metric C.S.A. mm 2 U.S. Wire Gauge 0.653 19 0.823 18 1.04 17 1.31 16 1.65 15 2.08 14 2.62 13 3.31 12 4.17 11 5.26 10 6.63 9 8.37 8 10.55 7 13.30 6 16.77 5 21.15 4 26.67 3 33.63 2 42.41 1 53.48 1/0 67.43 2/0 85.03 3/0 107.20 4/0 126.64 250 154.00 300 202.71 400 253.35 500 AWG or MCM AWG 300.0 400.0 500.0 625.0 304.00 600 354.71 700 405.35 800 506.75 1000 MCM summit.com/marine 23

The Industrial Marine Experts Low Smoke, Zero Halogen Marine Cable is In Stock Fires on board vessels can produce toxic gases and heavy smoke. Our marine low smoke, zero halogen (LSZH) cable can minimize the effects from these dangers. Save lives, protect your equipment from damage, and meet specifications that require use of LSZH cable. This cable is a low-cost alternative to the military spec cable often used in commercial applications. Ship-Set Quantities Available We stock a wide range of material to satisfy your immediate needs. Easy Identification Our low smoke, zero halogen cable is color coded to IEEE-45. Reduced Time and Labor Costs This ABS-approved cable offers flexible stranding and is easy to strip and terminate. In-house, custom cable armoring is available on request. Call for more information. Tested and Approved to IEC Standards This LSZH cable meets IEC standards for flame retardation, smoke density and halogen content. Top Construction Rating Cable construction is XLPE Insulation/SHF-1 Jacket. Get fast turn around and low minimums on non-stock items and special constructions. Marine Division 621 Time Saver Avenue Harahan, LA 70123 summit.com/marine Call Toll Free: (888) 326-5174 Email: marine@summit.com