Similar documents
Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

Public Comment No. 7-NFPA 30A-2013 [ Section No ]

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Remove the "Exception" text to be consistent with direction provided in the MOS.

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

26 of 128 9/23/2014 9:25 AM

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

MEMORANDUM. Technical Committee on Board and Care Facilities. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

First Revision No. 15-NFPA [ Chapter 2 ]


SAF-BCF SECOND REVISIONS WITH STATEMENTS

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

NFPA 45 NFPA 211 NFPA 1600

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Second Revision No. 36-NFPA [ Detail ] Submitter Information Verification. Committee Statement 5/18/2015 1:01 PM

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

Report on First Revisions with Statement June 2014 NFPA 101

NFPA 37 Public Comment Responses Page 1 of 32

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

12/21/2015 National Fire Protection Association Report

1 of 4 10/26/2015 1:58 PM. Committee Input No NFPA [ Section No ]

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input


Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

First Revision No. 20-NFPA [ Section No ]


TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Committee on NFPA 85

First Revision No. 1-NFPA [ Chapter 2 ]

Second Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 6/23/ :34 AM

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

Second Revision No. 2-NFPA [ Section No ]

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM


Report on First Revisions with Statement June 2014 NFPA 101

Public Comment No. 2-NFPA [ Section No ]

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

Public Input No. 3-NFPA [ Chapter 2 ]

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

LABELING OF FIRE-RATED GLAZING STUDY GROUP REPORT TO CTC MEETING CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

CHAPTER 5: EXHAUST SYSTEMS

CHAPTER 8 CHIMNEYS AND VENTS

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Committee on NFPA 51A

Technical Committee on Incinerators and Waste Handling Systems

Report on First Revisions with Statement June 2014 NFPA 101

CHIMNEYS AND VENTS CHAPTER 8

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

MEMORANDUM. Technical Committee on Protected Premises Fire Alarm and Signaling Systems

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

CHAPTER 8 CHIMNEYS AND VENTS

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

Throughout standard remove references to the following and replace with the following:

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

Report on First Revision June 2014 NFPA 5000

First Revision No. 36-NFPA [ Section No. 1.1 [Excluding any Sub-Sections] ]

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Committee on NFPA 30A

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

Report on First Revision June 2014 NFPA 101

National Fire Protection Association

IMC Significant Changes Summary Tier I

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

"Spray area" is the term that is used throughout the document. This change is for consistency.

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Transcription:

Page 1 of 15 Second Revision No. 8-NFPA 82-2013 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 13, Standard for the Installation of Sprinkler Systems, 2013 edition. NFPA 31, Standard for the Installation of Oil-Burning Equipment, 2011 edition. NFPA 54, National Fuel Gas Code, 2012 edition. NFPA 58, Liquefied Petroleum Gas Code, 2011 4 edition. NFPA 70, National Electrical Code, 2011 4 edition. NFPA 80, Standard for Fire Doors and Other Opening Protectives, 2013 edition. NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, 2012 edition. NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, 2013 edition. NFPA 259, Standard Test Method for Potential Heat of Building Materials, 2013 edition. NFPA 5000, Building Construction and Safety Code, 2012 edition. Submittal Date: Thu Apr 04 10:57:24 EDT 2013 Updated references in accordance with the NFPA regulations. Notes: Date Submitted By Apr 4, 2013 Duval The names of the NFPA 70 and 5000, where not changed. They should not be underlined.

Page 2 of 15 Second Revision No. 7-NFPA 82-2013 [ New Section after 3.3.3 ] 3.3.4 External Waste Compactors. A waste compactor that is located outside of a building, but is accessed (i.e., hand-fed) from inside the building by means of an intake door and a hopper. Submittal Date: Wed Apr 03 15:29:42 EDT 2013 The added a new definition to further clarify the external waste compactor. Notes: Date Submitted By Apr 4, 2013 Duval New section, renumber subsequent sections.

Page 3 of 15 Second Revision No. 9-NFPA 82-2013 [ Section No. 3.3.5 ] 3.3.6 Gravity Chute Intake Door. See 3.3.3.1. Submittal Date: Thu Apr 04 11:08:09 EDT 2013 This term was removed in the First Draft, it is no longer used in the document. It is removed to avoid any confusion.

Page 4 of 15 Second Revision No. 10-NFPA 82-2013 [ Section No. 3.3.9 ] 3.3.10 Pneumatic Chute Loading Door. See 3.3.3.2. Submittal Date: Thu Apr 04 11:09:22 EDT 2013 This term was removed in the First Draft, it is no longer used in the document. It is removed to avoid any confusion.

Page 5 of 15 Second Revision No. 12-NFPA 82-2013 [ Section No. 6.2.2.6.3 ] 6.2.2.6.3 All unlined steel chutes shall be protected internally by automatic sprinklers. (See 6.2.6.1.) Submittal Date: Thu Apr 04 12:34:48 EDT 2013 Editorial correction - corrected a cross-reference. The cross-reference is supposed to be to the sprinkler requirements for gravity chutes (6.2.6.1) and not to the chute intake door requirements (6.2.3.3.1). Notes: Date Submitted By Apr 4, 2013 Duval Cross-reference is to 6.2.6.1

Page 6 of 15 Second Revision No. 1-NFPA 82-2013 [ Section No. 6.2.3.3.2.4 ] 6.2.3.3.2.4 A key shall be required to open the door. A lock shall be provided for the chute intake door. Submittal Date: Wed Apr 03 09:07:35 EDT 2013 The revised this section to clarify that the door is to be locked, not necessarily need a traditional key, but by the use of a locking mechanism such as electronic card readers or a key. Notes: Date Submitted By Apr 4, 2013 Duval Nor shown legislatively correct. Public Comment No. 8-NFPA 82-2012 [Section No. 6.2.3.3.2.4]

Page 7 of 15 Second Revision No. 2-NFPA 82-2013 [ Section No. 6.2.5.2 ] 6.2.5.2* Service Opening Room Key. Limited-Access Chute Intake Room. 6.2.5.2.1 If entrance to a limited-access chute intake room is gained by key provided with a lock, the chute intake door shall not require a key to be opened lock. 6.2.5.2.2 One opening or the other shall be keyed. 6.2.5.2.3 Keying shall be required only for limited-access installations. Submittal Date: Wed Apr 03 09:16:53 EDT 2013 The revised this section to be consistent with SR-1 and to clarify language and added annex material, see SR-16. Notes: Date Submitted By Apr 3, 2013 Duval Annex material to be moved

Page 8 of 15 Second Revision No. 3-NFPA 82-2013 [ New Section after 6.4.3.2.2 ] 6.4.3.2.3 Fire dampers shall not be required where an engineered alternative system is provided that is acceptable to the authority having jurisdiction. Submittal Date: Wed Apr 03 09:46:24 EDT 2013 The addition of 6.4.3.2.3 will provide consistancy with 6.3.5.2.3. Public Comment No. 9-NFPA 82-2012 [New Section after 6.4.3.2.2]

Page 9 of 15 Second Revision No. 5-NFPA 82-2013 [ Section No. 8.3 ] 8.3 External Waste Compactors. (Reserved) 8.3.1 The compactor shall be constructed of noncombustible material. 8.3.2* The compactor hopper extension access from the building shall be protected by a self-closing, fire resistance rated intake door in accordance with 6.2.3.1.3. 8.3.3* Fire department access shall be maintained in accordance with the local building code. 8.3.4 Compactor extinguishing and access point shall be clearly marked. 8.3.5 The intake door shall be located in a room in accordance with the applicable requirements of 6.2.5. Submittal Date: Wed Apr 03 11:44:06 EDT 2013 The committee expanded on the requirements for external fed waste compactors. The main hazard associated with these types of waste compactors is the risk of fire and smoke spread from the compactor back into the building. The also added in a definition to clarify how an external waste compactor is different than a waste compactor.

Page 10 of 15 Second Revision No. 24-NFPA 82-2013 [ Section No. 11.2.1 ] 11.2.1 Chute intake loading and discharge doors shall be maintained clear and unobstructed at all times. Submittal Date: Thu Apr 04 14:08:07 EDT 2013 The term 'loading' was replaced by 'intake' during the First Draft stage. This revision is to make it consistent with the rest of the document.

Page 11 of 15 Second Revision No. 4-NFPA 82-2013 [ New Section after 11.4.2 ] 11.5 Decommissioning of Waste and Linen Handling Systems and Equipment. Section 11.5 shall apply where a waste or linen chute is taken out of service permanently. 11.5.1 Chute Intake Door. The chute intake door shall be removed on all floors and the opening shall be filled with construction equivalent to the construction of the shaft or replaced with an access door with a fire protection rating in accordance with 6.2.3.1.3. 11.5.2 Chute Intake Room. If the chute intake room is a fire resistance rated room and is no longer used for storage of combustible materials, then the fire resistance rating of the room shall not be required to be maintained. 11.5.3 Chute Discharge Room. 11.5.3.1 Except as permitted by 11.5.3.2, the fire resistance rating of the chute discharge room shall be maintained and the door at the bottom of the chute shall be maintained in a closed position. 11.5.3.2 If the chute discharge room is no longer used for storage of combustible materials and the opening in the wall/floor accessing the chute is sealed with construction equivalent to the construction of the floor slab or replaced with a fire-rated access door with a fire rating in accordance with 6.2.3.1.3, the fire resistance rating of the room shall not be required to be maintained. 11.5.4 Chute Sprinkler System. 11.5.4.1 Sprinklers within the decommissioned chute shall be permitted to be taken out of service. 11.5.4.2 Where the sprinklers are not taken out of service, access to inspect and service the sprinklers in the chute shall be provided. 11.5.5 Waste Wash-Down System. Wash-down systems within the decommissioned chute shall be taken out of service. Submittal Date: Wed Apr 03 11:10:32 EDT 2013

Page 12 of 15 Based on the First Revision for the addition of the general chapter which added that all doors are to be installed and maintained in accordance with NFPA 80 except as modified, the wanted to make sure that when chutes are taken out of service permanently, the doors are removed properly while maintaining the fire-resistance rating of the chute enclosure. In order to maintain the rating of the chute enclosure (shaft), the openings need to be protected. When a chute is taken out of service, typically, the chute doors are left in place. This is fine, so long as these doors are not secured shut. When a door is permanently secured shut, it is no longer keeping the rating. Part of the fire resistance rating requirement for doors is to be able to inspect the door. If the door is not able to open, it is not considered to have the fire rating. It is this reason that the added in the requirements for decommissioning a chute, to give the users a method to remove the chute door while maintaining the rating of the chute enclosure.

Page 13 of 15 Second Revision No. 16-NFPA 82-2013 [ New Section after A.6.2.3.2.1 ] A.6.2.5.2 Locking is required only for limited-access installations. One opening or the other should be locked, but both are not required to be locked. Submittal Date: Thu Apr 04 13:22:47 EDT 2013 Added annex material for clarification of SR-2-NFPA 82-2013.

Page 14 of 15 Second Revision No. 26-NFPA 82-2013 [ Section No. A.6.2.3.2.1 ] A.6.2.3.2.1 The door or damper at the discharge opening of a waste chute is not required to be a labeled assembly; but rather shall should be of construction similar to a rated assembly to afford the protection required by 6.2.3.1.3. Submittal Date: Thu Apr 04 14:17:41 EDT 2013 Editorial correction - removal of 'shall' from the annex and replaced with 'should'.

Page 15 of 15 Second Revision No. 6-NFPA 82-2013 [ New Section after A.6.4 ] A.8.3.2 The intake door in this section is in reference to the door located in the building that is the access opening into the exterior waste compactor. The door opens into the hopper that extends to the compactor. The hopper extension should extend at least 1.83 m (6 ft) beyond the building so that the angle does not cause blockage or a build-up of waste. As always, waste compactors and components should be installed in accordance with the manufacturer's instructions. A.8.3.3 The fire department access is typically a separate door into the compactor. This door allows for the fire department to easily access any potential fire within the compactor. Submittal Date: Wed Apr 03 15:07:11 EDT 2013 The added in some annex material to help further clarify the requirements added on external fed waste compactors. The recommended the distance of 6 ft from the building because during a survey of existing installations, most compactors where located more than 6 ft from the building. The distance of 6 ft is intended to give the user a distance that will allow for an angle to prevent waste building-up in the hopper. Additionally, as with most self-contained and breakaway compactors, there should be a separate fire department access door located on the compactor. The added in clarification for the reason why there should be a separate door and it being maintained.