ARCHITECTURAL REVIEW BOARD SUPPLEMENTAL PACKAGE 3402 PICO BLVD SANTA MONICA, CA 90405
S CENTINELA AVE (E) SIDEWALK 41 42 43 44 45 (E) EXTENT OF NEW FENCE 40 39 38 37 CALTRANS LOT PARKING 68 EXISTING SPACES OFF-SITE 36 35 34 33 32 31 30 73 72 71 46 47 48 49 50 29 28 27 70 69 51 52 26 68 53 I-10 FREEWAY ABOVE LINE OF FREEWAY EDGE ABOVE 16 17 18 19 20 21 22 23 WIND TURBINES; SEE SHEET A1.26 25 24 Sim 1 1.37 87 86 85 84 83 82 81 PARKING 87 EXISTING SPACES ON-SITE 80 79 78 77 76 75 74 67 66 65 64 63 62 61 54 55 56 57 58 59 60 1 1.23 Sim NEW SOLAR CANOPY STRUCTURES ABOVE PARKING SPACES (E) STAIR TO CALTRANS LOT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PROPERTY LINE (E) CONCRETE SIDEWALK PROPERTY LINE LANDSCAPED AREA (E) BALCONY OVERHANG EAST ENTRY (E) LIGHT POST (E) BIKE PARKING (N) SEATING AREA (E) EXISTING FENCE (N) RAMP 3402 PICO BLVD F.P.S.C. LANDSCAPED AREA (N) SUNKEN COURTYARD F.P.S.C. 3402 PICO (N) EXTENT OF NEW FENCE NEW RAMP NEW LANDSCAPING NEW STAIRS PICO BLVD SIDEWALK RAMP (E) BIKE SHARE NORTH ENTRY (N) EXTENT OF BLACK WIRE MESH FENCE (N) BLACK WIRE MESH FENCE (E) FIRE DEPT CONNECTION ATRIUM/ COURTYARD F.P.S.C. (E) WEST ENTRY STAIR F.P.S.C. 34TH ST (E) MECHANICAL ENCLOSURE (E) LINE OF SIDEWALK (E) SITE WALL WITH GATE 3 1.22 Sim (E) RAMP NEW PERGOLA SEATING AREA LANDSCAPED AREA (E) MECH AREA (N) BLACK WIRE MESH FENCE (N) EXTENT OF BLACK WIRE MESH FENCE SITE PLAN (SCALE: 1" = 40'-0") A1.08 (E) GATE (E) DRIVEWAY (E) = EXISTING (N) = NEW N
1 1.020 1.18 CALTRANS LOT LANDSCAPED AREA 2 EAST ENTRY LANDSCAPED AREA 179' - 10" V.I.F. SEATING AREA EXISTING (NO CHANGE) 4' - 7" 170' - 10 1/2" V.I.F. 4' - 4 1/2" V.I.F. EXISTING BALCONY AND GUARDRAIL (NO CHANGE) BIKE PARKING V.I.F. 5' - 6 1/2" V.I.F. RAMP EXISTING MAINTENANCE DOOR UP NEW DOOR (E) MEN'S RESTROOM (E) WOMEN'S RESTROOM NEW MAINTENANCE DOOR, TYPICAL (3'-9 x 8'-8) NEW SUNKEN COURTYARD LANDSCAPED AREA SIDEWALK ATRIUM / COURTYARD SEATING AREA 2 1.020 1.016 1.19 12 (E) EXTENT OF NEW FENCE OFFICE SPACE NEW PLANTERS OPEN TO BELOW REMOVE PORTION OF EXISTING STAIR OPENING OFFICE SPACE (E) MEN'S RESTROOM 112' - 3" V.I.F. 122' - 3" V.I.F. EXISTING (NO CHANGE) 2 1.19 NEW PERGOLA STRUCTURE PICO BVLD RAMP NEW DOOR NEW STAIRS TO GROUND FLOOR (E) WOMEN'S RESTROOM NEW DOOR NORTH ENTRY (E) ELEVATOR LOBBY UP LANDSCAPED AREA EXISTING STAIRS TO LEVEL 3 PLANTERS NEW GATE NEW GATE 4' - 5 1/2" V.I.F. RAMP MECH EXISTING GATE (N) EXTENT OF BLACK WIRE MESH FENCE BIKE SHARE EXISTING FIRE DEPARTMENT CONNECTION SIDEWALK NEW BLACK WIRE MESH FENCE 1 1.18 EXIT DOWN TO 34TH STREET EXISTING WALL GREEN PAINT 34TH STREET (E) LINE OF SIDEWALK NEW BLACK WIRE MESH FENCE (N) EXTENT OF BLACK WIRE MESH FENCE EXISTING WALL GREEN PAINT N 3402 PICO LEVEL 2 FLOOR PLAN (SCALE: 1/16"=1'-0") A1.11
PROJECT DESCRIPTION REFER TO SHEET A1.00 OF PACKAGE SUBMITTED ON MARCH 21, 2017 CORNER VIEWS SUPPLEMENTAL SHEET INDEX 1.08 ARB - SITE PLAN 1.11 ARB - SECOND FLOOR PLAN 1.32 ARB - COVER PAGE 1.33 ARB - PROJECT INFO 1.34 ARB - RENDERING - CORNER (UPDATED) 1.35 ARB - RENDERING - 34TH ST (UPDATED) 1.36 ARB - SOLAR CANOPIES 1.37 ARB - WIND TURBINES 1.38 ARB - ATRIUM PLANTERS 1.39 ARB - SUNKEN COURTYARD EXISTING PERSPECTIVE PROPOSED PERSPECTIVE (UPDATED) 3402 PICO PROJECT INFORMATION A1.33
3402 PICO PICO AND 34TH ST VIEW - UPDATED RENDER A1.34
3402 PICO 34TH STREET VIEW A1.35
SOLAR CANOPY STRUCTURES VIEW LOOKING NORTHEAST SOLAR CANOPIES AND WIND TURBINES ELEVATION 1/16" = 1'-0" 3402 PICO SOLAR CANOPIES A1.36
4' - 7 3/16" 5' - 3" FREEWAY ABOVE PROPERTY LINE SUN CAR SHADES; TYP C 1.37 1.033 2 B 1.37 30' - 0" WIND TURBINE SPECIFICATIONS DRIVEWAY DRIVEWAY URBAN GREEN ENERGY - EDDY 25' - 11" AXIS: VERTICAL HEIGHT: 5.3 FT (1.60 M) WIDTH: 4.6 FT (1.40 M) SWEPT AREA: 22.6 FT 2 (2.1 M 2 ) BLADE MATERIALS: CARBON FIBRE AND FIBERGLASS A 1.37 RATED POWER: CUT-IN WIND SPEED: RATED RPM: SURVIVAL WIND SPEED: RATED WIND SPEED: ANNUAL ENERGY AT 5 M/S: NOISE FROM IEC 61400-11 AT 12M/S: 600 W 7 MPH (3.5 M/S) 200 RPM 110 MPH (50 M/S) 26 MPH (12 M/S) 950 KWH 36 DB WIND TURBINE LOCATION (1 OF 3) GENERATOR TYPE: DRIVE SYSTEM: RATED OUTPUT OFF-GRID: GRID-TIE: INVERTERS AND CONTROLLERS: 3-PHASE PERMANENT MAGNET DIRECT DRIVE 24 VDC 600 VDC AVAILABLE FOR ALL LOCATIONS AND REGULATIONS WIND TURBINE - PROPOSED DRIVEWAY PLAN - WIND TURBINES 3/32"-1'-0" N LANDSCAPING TREES LANDSCAPING TREES LANDSCAPING TREES ENLARGED PLAN - WIND TURBINE A ENLARGED PLAN - WIND TURBINE B ENLARGED PLAN - WIND TURBINE C 3402 PICO WIND TURBINE DETAILS A1.37
3402 PICO ATRIUM PLANTERS A1.38
SUNKEN COURTYARD REFERENCE IMAGE 1 SUNKEN COURTYARD REFERENCE IMAGE 2 SECTION A DETAIL SCALE: 1/16"=1'-0" SECTION B DETAIL SCALE: 1/16"=1'-0" SUNKEN COURTYARD PLAN 3402 PICO SUNKEN COURTYARD A1.39