Human-Oriented Medical Laser Company. ELESYS Company introduction

Similar documents
OptoYag M. clear vision

The focused solution for YAG laser procedures

clear & preserve vision OptoYag&SLT

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

808nm Diode Laser Hair Removal Machine. Diode Laser Hair Removal System 808S User Manual

Medical Lasers and Laser Safety

OptoSLT M. preserve vision

Lasers in Veterinary Practice. Safe Use Guidelines

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Company profile and Products

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

3kW 6kW, QUBE Fiber Lasers

LASER SAFETY PLAN OPHTHALMOLOGY

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

, Backsuk-ri, Paju-eup, Paju-city, Gyeonggi-do, Korea TEL: FAX:

Important Safety Notice

The Optimum LED Headlight. I. Company Introduction Product Features Product Certification

EVERLIGHT ELECTRONICS. Company Profile LIGHTING FOREVER. A New Frontier in LED technology VER EL

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

THERMOFOCUS 01500A3 THERMOFOCUS

Laser Safety Goggle. UV Visible

*For inquiries and questions about lasers, see the Yellow-Page.

Laser Safety. The George Washington University Office of Laboratory Safety Ross Hall, Suite B

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

Dual Laser InfraRed (IR) Thermometer

BT-500. Infant Incubator. BT-500 Infant Incubator

Why is Laser Safety Important Laser usage is growing rapidly Industrial applications Heavy use now in laboratories for research, analysis Many

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

Instructions for use by laboratory personnel. laser. safety. Pôle Maîtrise des Risques Direction de la Protection et de la Sûreté Nucléaire

Class 1 laser beam sensor safe for your eyes

OMA-300 Process Analyzer

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Identify the key elements of the laser source, regardless of the type of measurement or sensor required;

Laser Safety Training

Laser Use Authorization

Lasers and Laser Safety

Models S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Class 1 laser beam sensor safe for your eyes

North Dakota State University Laser Safety

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

APPLIED. OMA-406R Rackmount Process Analyzer

THERMOFOCUS 0800H5 Professional

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

CLEAN-LASERSYSTEME GMBH

Laser Collimated Beam Sensor

MITSUBISHI ELECTRIC ANNOUNCES DEVELOPMENT OF 5.6 W 213 nm DEEP ULTRAVIOLET SOLID STATE LASER

Diode-Pumped Solid-State Blue Lasers

Laser Use Registration & Application (L.U.R.)

Class 1 laser beam sensor safe for your eyes

LM-80V , h V LM-30V h V

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Eickemeyer Vetrix Laser

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

CALIBRATION HOW IT WORKS

Solo PIV Nd:YAG Laser System Operator s Manual

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

Dual Laser InfraRed (IR) Thermometer

Laser Safety Program

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Policy Redesign Project. Laser safety. Table of Contents

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Creating Partnership for Life. - Company Overview - YH Kim E-WHA Biomedics Co. Ltd. Tel Fax

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

INNOVATIVE ACOUSTIC RESONANCE SYSTEM

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Northern Illinois University Laser Safety Manual

All personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab.

Laser Safety Management

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

>Laser Marking. Products PRODUCT GUIDE

10.6 Schedule of Accreditation

A Chiller is equipment to control temperature of customers heating sources. Application Examples

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Basic Laser Safety Training

VCSEL & Invisible Light LED

Wavelengths: From UV to Visible and IR COBRA TM Max

PRESENTATION OF DAEWOO GAS BOILER

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Break-in Detection and Alarm System

G4 Pulsed Fiber Laser

E. GentleLASE Family of Laser Systems 510k Summary JL1

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Transcription:

Human-Oriented Medical Laser Company ELESYS Company introduction

CONTENTS I. About Elesys Mission Organization chart History II. Products Co2 laser system Co2 fractional laser system 808 diode laser system Q-S/W Nd:Yag laser system IPL system LLLT system III. Global network IV. Certification

I. About Elesys We had established UTI Co., Ltd. In 2002. The company name was changed to ELESYS Co., Ltd. On January, 2016. We have devoted ourselves to the laser technology of using laser light and manufactured medical laser equipment for the dermatology and cosmetic surgery treatment. Since 2002, we have been developing and manufacturing medical laser equipment in the field of aging skin improvement and skin ailment treatment under the slogan of Human-oriented company We already entered global market of dermatology and cosmetic surgery treatment. As a result, we have the credit of superiority of our products from a lot of doctors. We also keep making a challenge to the market of skin treatment field on the basis over 10-year medical laser technology. ELESYS Co., Ltd. Is well aware how helpful a lot of people s cheers and support, including doctors, Would be up to this day. We will keep making a challenge to the treatment using light for mankind to lead a happy and healthy life. Also, we will keep doing our best to be a world class company that creates customer value. Philosophy We always consider customer s satisfaction priority.

I. About Elesys MISSION Management Ideology

I. About Elesys Business Area R&D OEM SALES MANUFACTURING

I. About Elesys Organization chart CEO Vice-President General Affairs Sales Quality Control Production Quality Control Tax accounting Personnel management Record management Domestic Overseas Marketing Sales management Customer s management Complete product inspection Raw martials inspection Quality Improvement Quality document management Complete product production Technical support for Sales department New product development Product upgrade Development management Technical support for Production department

I. About Elesys History 2002 Established UTI Acquired KFDA Cert. Developed Co2 Laser Developed HE-NE Laser Developed Smoke evacuator 2003~2004 ISO9001, ISO13485, Directive93, Directive 42, EEC Acquired permission of articles: Co2 Laser, He-Ne Laser Developed IPL System Developed Q S/W Nd-YAG 2005~2006 Acquired permission of article: IPL System Q S/W Nd-YAG Acquired CE for two different types of device KGMP Developed fractional laser Developed LED 2007~2008 ISO9001, ISO13485, Directive93, Directive 42, EEC Acquired permission of articles: Co2 Laser, He-Ne Laser Developed IPL System Developed Q S/W Nd-YAG 2009~2010 Received the million-dollar export tower Acquired permission of articles: 808nm diode laser Developed New IPL version Developed new Q S/W Nd-YAG 2011~2012 Acquired permission of article: New IPL Acquired permission of article: Q S/W Nd-YAG Merged with Elesystech Co., Ltd 2013~2014 Developed New Diode laser Acquired permission of articles: 808nm Diode laser Developed LED Merged with Medisco Co., Ltd Developed New IPL 2016 Company name Changed : UTI to ELESYS

II. Products Co2 Laser Co2 Laser Co2 fractional laser Co2 Laser 1000NAIN CO ONE LINEXEL HELIA

II. Products 808 Diode laser 808 Diode laser IPL LLLT System Smoke evacuator Allie Allie lite Photo/pulse Healux Cleair

II. Products 1000NAI : COONE : Surgical co2 laser Laser type Laser mode Continuous power Aiming beam Control panel Operating model Cooling system Memory Cooling system Input Memory power Input power CO 2 laser with infrared emission at 10.6m wavelength TEM00 gaussian mode 0.5~30 watts to tissue 5mW 3mW diode laser beam 650nm (Light adjustable) Color LCD display touch and screen soft touch CW 0.5 ~ 30w Pulse 0.5 ~ 15w 20w Ultra pulse (Maximum 0.5 ~ 20w peak power 500w) Ultra - Maximum pulse frequency peak power 10~500Hz 300w (Adjustable) Ultra - Ultra pulse duration frequency 10~100us ~500Hz (Adjustable) -Water Ultra pulse cooling duration with sealed ~800s closed (Adjustable) circuit 9 Water save cooling with sealed closed circuit AC 9 save 200V, 60Hz AC 200V, 60Hz

II. Products LINE XEL : CO2 fractional laser Laser type Laser mode Aiming beam Control panel Duration Degree Scanner mode Adjustable spot size Cooling system Delivery Ambient temperature Input power Dimensions Weight RF CO 2 laser (10.6um) TEM00 3mW diode laser beam 650nm Wide LCD panel with Touch Screen 100us ~ 16,500us 1~10th Microprocessor controlled Square, Rectangular, Circle, Ellipse 50microns Air Circulation 7 jointed articulated arm 20 ~60 Humidity 80% AC 200V, 60Hz 270x487x853mm (WxLxH) 45kg

II. Products HELIA : Q-S/W Nd:YAG laser Laser medium Wavelengths Output power Pulse rate Spot size Aiming Beam Optical Delivery Cooling system Input power Power consumption Weight Nd:YAG 1064nm / 532nm QS Mode 1064nm : 100mJ ~ 1200mJ 532nm : 50mJ ~ 500mJ TS Mode DP Mode(1064nm) : 100mJ ~ 1600mJ MP Mode(1064nm) : 600mJ ~ 1800mJ 1Hz ~ 10Hz±10% 2~10mm (Auto sensing) 650nm / 5mW Articulated Arm Closed circuit water cooling Ac220v / 60Hz 220VA 87kg

II. Products ALLIE : 808 Diode laser Laser type Diode power Wavelength Pulse duration Repetition rate Spot size Delivery Cooling Control panel Input power Platform weight Platform size Diode (Continuous wave) 640w 808nm 2 ~ 60ms 1 10Hz / 1Hz step 8mm x 18mm Direct cooling through sapphire tip Sapphire tip contact with water temperature control chiller Wide LCD panel with touch screen AC 220v, 60Hz 55kg 350x750x1,162 (WxLxH)

II. Products ALLIE Lite : 808 Diode laser Laser type Electrical Requirements Power consumption Wavelength Dimensions Weight Repetition Rate Spot size Pulse Duration Maximum Energy Beam Delivery Cooling Device Irradiation Control Display Diode (Continuous wave) AC220v (50/60Hz Single Phase) 2KW (Maximum) 808nm 380x530x1080mm (WxDxH) 55kg 1 10Hz, 20Hz (FHR) 10x12mm 20ms~80ms 40J (max) Handpiece Thermo electric module water cooling system Foot Switch TFT color LCD, Touch screen

II. Products Photo pulse : IP2L SYSTEM Light source Intense pulsed light xenon lamp Wavelength 510, 560, 585, 640, 700nm Output energy 10 ~ 50J/ cm2 Pulse width Single pulse 6ms ~ 32ms Train pulse 6ms ~ 50ms Pulse sequence 2~3 pulses Control panel Touch screen Spot size 15x35mm Cooling system TEC (Thermo Electric Cooler) Input power AC200V, 60Hz Dimensions (WxDxH) 542 x 609 x 1,160 mm Weight 70

II. Products Healux : LLLT System Wavelength 420nm, 635nm, Dual wave length Method LED (Light Emitting Diode) Class Class 1, B type Wavelength Blue : 420m, ±10nm, RED : 635nm ±10nm Out power 1 ~ 40 mw / cm2 ±10% Time set 1 minute ~ 30 minute Pulse repetition 1Hz, 5Hz, 10Hz, 15Hz, Continue Area Blue : 135mm x 65 mm (4ea) ±10% Red : 135 mm x 65 mm (4ea) ±10% Cooling device Air (Fan) Interface Touch screen Platform weight 26kg Platform size 390x480x1,795 (WxLxH)

II. Products Cleair : Smoke Evacuator Model CLE-AIR Type Smoke evacuator(exchanged filter) Suction rate Max 1200w 3-ways filter(pre-filter, Carbon-filter, Hepa-filter) Efficient : 0.3 μm, >99.975% Carbon-filter : 1-grade (Made in Korea) Adsorption rate : 950g/cc (Generally : 600~750g/cc)

III. Global Network We have a lot f global network and retain strong connection Japan, China, Hongkong, Vietnam, Malaysia, Indoesia, Kuwait, Oman, UAE, Saudi Arabia, Qatar, Bahrain and more. Our purpose is to be a No1 Medical laser company In the World

IV. Certification ISO 13485 GMP Cert. Manufacturer Cert. 의료기기제조허가 Free sales Cert. 의료기기제조허가

ELESYS Co., LTd #1313, E-dong, 60, Haan-ro, Gwangmyeong-si, Gyeonggi-do, KOREA (Gwangmyeong Technopark, Soha-dong) T. +82. 32. 341. 6083 +82. 2083 2078 +82. 70. 7014. 2090 F. +82. 2. 2083. 2380 E-mail. Master@elesysmedi.com Homepage. http://www.elesysmedi.com