Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Similar documents
The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Purdue e-pubs. Purdue University

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Efficiency of Non-Azeotropic Refrigerant Cycle

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Compressor Capacity Control: A New Direction

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Low GWP Refrigerants for Air Conditioning Applications

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

High Efficiency R-134a Compressor for Domestic Refrigerator

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

System Modeling of Gas Engine Driven Heat Pump

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Study of R161 Refrigerant for Residential Airconditioning

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

Performance of CO2 Cycles with a Two-Stage Compressor

System Using Exhaust Heat from Residential GHPs

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Sub-Critical Operation of the CO2 Expander/ Compressor

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

R32 Compressor for Air conditioning and Refrigeration applications in China

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Design of Compressors to Meet the Performance Ranges Required for Residential Air Conditioning

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Performance Testing of Unitary Split-System Heat Pump with an Energy Recovery Expansion Device

Compressor Capacity Control

Effect of the Use Pattern on Performance of Heat Pump Water Heater

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Performance of an Improved Household Refrigerator/Freezer

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Experimental Study on the Performance of Twisted Capillary Tube

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

A study of Transient Performance of A Cascade Heat Pump System

Low Global Warming Refrigerants For Commercial Refrigeration Systems

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

A Study on Compression Characteristic of Wet Vapor Refrigerant

Air-Cooled Heat Exchanger Performance for R410A

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Dynamic Simulation of Liquid Chillers

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Numerical Evaluation of Performance Curves of a High Frequency Microcompressor

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design Jeongtaek Park LG Electronics Seyoon Oh LG Electronics Chanho Song LG Electronics Hoseon Choi LG Electronics Follow this and additional works at: http://docs.lib.purdue.edu/iracc Park, Jeongtaek; Oh, Seyoon; Song, Chanho; and Choi, Hoseon, "Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design" (2006). International Refrigeration and Air Conditioning Conference. Paper 798. http://docs.lib.purdue.edu/iracc/798 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

R110, Page 1 Improving Heating Performance of a MPS Heat Pump System with Consideration of Compressor Heating Effects in Heat Exchanger Design Jeong Taek Park 1, Se-Yoon Oh 2,, Chan Ho Song 3, Ho Seon Choi 4 1 Junior Research Engineer, Digital Appliance Research Laboratory of LG Electronics 222-22 Guro 3-dong, Guro-gu, Seoul, Korea Tel: 82-2-818-2439, Fax: 82-2-856-0313, Postcode: 152-848, E-mail: mirage5928@lge.com 2 PhD, Chief Research Engineer, Digital Appliance Research Laboratory of LG Electronics 222-22 Guro 3-dong, Guro-gu, Seoul, Korea Tel: 82-2-818-7870, Fax: 82-2-856-0313, Postcode: 152-848, E-mail: syo@lge.com 3 PhD, Chief Research Engineer, Digital Appliance Research Laboratory of LG Electronics 222-22 Guro 3-dong, Guro-gu, Seoul, Korea Tel: 82-2-818-7982, Fax: 82-2-856-0313, Postcode: 152-848, E-mail: song1018@lge.com 4 Chief Research Engineer, Digital Appliance Research Laboratory of LG Electronics 222-22 Guro 3-dong, Guro-gu, Seoul, Korea Tel: 82-2-818-3545, Fax: 82-2-856-0313, Postcode: 152-848, E-mail: hschoi@lge.com ABSTRACT An innovative way of improving heating performance was developed for a 3.5 RT MPS (Multi Power System) heat pump system. In the heat pump system, there were three heat exchangers, one in each front, rear and bottom. The front and rear heat exchangers were supplied with the air from open space when the bottom heat exchanger was supplied with the air heated by the compressor. The result came out as the great temperature difference between the incoming air and the refrigerant in the bottom heat exchanger. The difference was greater than those in the other two heat exchangers. The inlet air temperatures were numerically estimated with a commercial code, and the compressor was modeled as a constant temperature heat source. The temperature distributions were obtained over the three heat exchangers. According to the temperature profile, the refrigerant distribution to the three heat exchangers was redesigned, which means more refrigerant was distributed to the portion of the heat exchanger with greater temperature difference between the air and refrigerant. It directs to improvement of heating capacities by 10% and in addition of 5 % for low temperature heating steady state, and standard rating conditions, ARI 210/240, respectively. The Heating Season Performance Factor, HSPF was improved by 5.2%, without any increase in cost or consuming more energy 1. INTRODUCTION The demand for energy efficiencies of air-conditioners have been increased since the environmental protection becomes more severe. The improvement on Coefficient of Performance, COP was the main theme in energy saving technology developments. But it was to say that the COP could not properly indicate the extended period energy consumption and also Heating Season Performance Factor, HSPF was more adequate index to represent the actual heating energy bills. The easier way of improving energy efficiency is to adopt more high priced components, such as BLDC motor, microprocessor-controlled variable speed compressor, and so forth. However, consumers seemed reluctant to pay more for air-conditioners just to save energy bills. In this thesis, a way of improving heating performance was developed by optimizing the refrigerant flow passes in heat exchangers as well as by utilizing the compressor as a heat source. The temperature field through the heat exchangers was analyzed with a commercial code, and HSPF was improved without adopting the high priced components.

R110, Page 2 2. SYSTEM CONFIGURATION & TESTING CONDITION 2.1 Multi Power System (MPS) Multi power system is consisted of two constant speed compressors with different capacity. A microprocessor controlled the compressor operation, depending on thermal loads, for example only small compressor operation, only large compressor operation, and both compressors operation. Thus, the cooling or heating capacity was modulated in three step and the energy was saved in the same way as that in the variable speed compressor driven air conditioner. The schematic diagram of Two compressor system is shown in fig. 1. There are two compressors, check valves and a common accumulator in parallel with condenser and evaporator. The working flow path is explained as follows. Two compressors are installed in parallel. Check valve is necessary to prevent refrigerant from flows back to the other compressor when only one compressor operates. The refrigerant that discharged from compressors, flows into evaporator and goes through expansion device, TXV. The expanded refrigerant flows into evaporator and goes into a common accumulator and compressors. The accumulator works as following. A refrigerant evaporated in evaporator, flows into an accumulator and the vapor refrigerant flows into each compressor though a suction line while the liquid refrigerant and oil are accumulated at the bottom of the accumulator. At this time, oil is recovered from the compressor though the oil-return hole with vapor refrigerant (Kim et al., 2003). Figure 1. The schematic diagram of 2 comp system 2.2 Heating Seasonal Performance Factor (HSPF) HSPF(Heating Seasonal Performance Factor) is used as a standard for defining the annual power consumption of a Heat pump system. It is defined as following for the capacity modulation system including two speed compressor or two compressors, or cylinder unloading (ARI standard 210/240,2003) HSPF= t BL( Tj) N E( Tj ) RH( Tj ) + N n N (1) Where, BL(Tj) = Building Load at Temperature Tj [Btuh] E(Tj) = The Heat Pump Electrical Energy Usage In Tj RH(Tj) = Supplementary Resistance Heat Term at Temperature Tj j = temperature bin index

R110, Page 3 Case IV Case II & III Case I Qss k=2 (47) DHRⅩC Qss k=2 (17) Qdef k=2 (35) Qss k=1 (47) Qss k=1 (62) Qss k=1 (17) Qdef k=1 (35) 65 T j BL ( T j ) = C DHR T 65 OD 0 T OD 17 35 47 62 65 Figure 2. HSPF graph of 2comp. system Two compressor system has three different operating regions that cover temperature and four compressor operating mode by changing compressor operation. The operating pattern with heating load is shown in fig. 2. In fig. 2, case. 1 is low compressor speed or single compressor, i.e., k=1, for which the building heating load. Seven test conditions are needed within four temperature ranges in order to calculate HSPF from ARI standard for the two-compressor driven heat pump. The test condition of 8.3 100% maximum operation has the greatest effect on the HSPF. Table. 1 Require Test condition (ARI Standard)] Cooling Heating Standard Standard Frost ARI SEER HSPF Single Speed Two Compressors Single Speed Two Compressors 2.3 Experimental Unit and Test Condition Experimental Unit is a split type unitary system. The indoor unit has an A-coil with 3-row, 20-step heat exchanger, and an AC motor. The outdoor unit has 2 compressors, common accumulator, control box, HEX and so forth. Outdoor unit is shown in fig. 3. The two compressors of the outdoor unit were from LG Electronics with the nominal capacity ratio of 60 to 40%. The BLDC motor was used for the outdoor fan. HEX has divided into three parts, front, bottom, and rear by position. The working fluid was refrigrant-22. Rear HEX Front HEX Control box Bottom HEX Accumulator 60% compressor Figure 3. Outdoor unit of LGE 40% compressor

R110, Page 4 The test condition is shown in Table 2, same as in the ARI. Table. 2 : Test condition in indoor and outdoor Test Indoor Unit air entering Outdoor Unit air entering Dry-bulb Wet-bulb Dry-bulb Wet-bulb Cooling Standard Rating conditions (A cooling condition) B cooling condition 26.7 26.7 19.4 19.4 35 27.8 23.9 18.3 Standard Rating condition 21.1 15.6 8.3 6.1 Heating Temperature Heating condition Temperature Heating condition 21.1 21.1 15.6 15.6 16.7-8.3 13.6-9.4 Frost Accumulation 21.1 15.6 1.7 0.6 3. FLOW SIMULATION The refrigerant flow passes in the heat exchangers were analyzed and redesigned to improve the HSPF. The heat dissipated from the compressors was regarded as heat sources, and the distribution of temperature over the heat exchangers were calculated with commercial software. 3.1 System modeling A commercial code, Star-CD(ver. 3.15-for window) was used to analyze the steady state temperature field of the heat pump outdoor unit. The compressors, the accumulator and the control box in the outdoor unit were included in the modeling, but the pipe between components was neglected due to small effects. We used approximately 440,000 cells to solve the computing region. The computing time took twelve hours by Pentium IV 2.8GHz processor. Main boundary conditions and mesh shape is shown in fig. 3. The heat exchanger was known as a porous media to save computing time. As for boundary conditions, constant air flow rate of 90CMM according to standard rating conditions was applied for the fan and experimentally obtained pressure drop across the heat exchangers was adopted. We created a simulation of standard rating condition and surround temperature of 35. Compressor had constant temperature of 85 Pressure drop (porous media) Wall condition (85 ) Figure 3. Boundary condition and mesh modeling 3.2 Simulation result Fig. 4 shows the velocity & temperature profile inside of the outdoor unit. The bottom HEX is inclined when the front HEX and rear HEX stand vertically. As a result, the velocity profile at the section A is lower than the one in section B, because section A is closer to the side wall. The large compressor has greater effect on the bottom HEX than the one from a small compressor. Because the large compressor is located closer to the side wall, the temperature distribution at section A is higher than the one at the section B. When the velocity around large compressor is slow, the heat from large compressor does not mix with intake air. The hot air around the large compressor enters the portion of the heat exchanger that located just above the large compressor and it leads the temperature distortion of 4 depending on locations in the bottom HEX, when the shell temperature of the

R110, Page 5 compressor is 85. As a result of simulation, the bottom HEX is more efficient than front & rear HEX in heating operation. Therefore, the bottom HEX is able to increase the number of pass by exercising refrigerant flow passage design. <Section A> <Section B> <Section A> <Section B> Section A Section B (a) Velocity distribution Figure 4. Simulation result (b) Temperature distribution Fig. 5 shows the velocity profile of air coming to the heat exchangers. The velocity at the top portion of the front HEX and rear HEX are the fastest due to their short distance to the fan. Also overall velocity profile located in the bottom HEX is the lowest because it is farthest from the fan. In the bottom HEX, the velocity also varies depending on the distance from the fan. The variation of the inlet air velocity is considered when designing refrigerant flow passes with assumption of the heat transfer rate is strongly dependent from the air velocity. Front-Hex Rear-Hex Bottom-Hex Figure 5. Velocity contour on HEX It reveals that the air flow rate becomes the highest when it is in the rear HEX, but the velocity becomes the highest when it is in the front HEX. The bottom HEX shows the lowest air velocity. These are resulted from the numerical calculations and provided to determine the number of refrigerant passes. 4. REFRIGERANT FLOW PASSAGE DESIGN The first design of the refrigerant pass was based on the equal tube length. The second design is included the numerical calculation results and changes in the pass length. As it shows in the Fig. 6, the refrigerant pass 1 and 2 in the rear HEX were designed shorter than passes 3, 4, and 5. The numbers of passes in the bottom HEX were increased to absorb more heat from the compressor in heating operation. It was increased by 20% due to the redesigning of passes for the rear and front HEX to decrease temperature difference within passes. 1 10 Air-flow 1 12 Air-flow 2 9 2 11 3 4 6 7 8 3 4 5 7 8 9 10 5 6 1 st design 2 nd design Figure 6. Hex Design

R110, Page 6 It shows in Fig. 9, evaporating temperature and temperature difference between maximum and minimum evaporating temperature in each HEX in standard rating heating operation. Evaporating temperature in 2 nd design increase than 1 st design, because temperature difference of 2 nd design is smaller than 1 st design. As a result of redesign, bottom has similar efficiency to rear HEX. 1 st design 2 nd design 2.5 3.53 2.0 2.2 1.3 1.5 1.1 0.8 1 st design 2 nd design (a) evaporating temperature Rear HEX Bottom HEX (b) max. temperature difference in path Figure 7. Temperature difference at standard rating condition Front HEX The distortion of the evaporating temperature was eliminated with the redesign of the refrigerant pass. The length of each pass was decreased and the flow resistance was reduced. As results, the heating capacity increased by 10%, which means 3,000 Btu/hr and EER improved by 0.5 compared to those of the first pass design. Also, the rated heating capacity increased by 5% in other words 4,0000Btu/hr increased and EER improved by 0.25. However, the cooling COP decreased by 3%, for the reason that the sub cooling at the condenser exit reduced. But the HSPF increased by 5.2%. Heating capacity 42500 40000 37500 35000 Heating capacity HSPF 8.5 8 7.5 7 6.5 6 5.5 HSPF 32500 1'st path design 2'nd path design Figure 8. Compare Standard rating Heating capacity & HSPF with HEX-design 5. CONCLUSIONS In this thesis, a latest way of improving HSPF was presented without adopting high priced components. The refrigerant flow pass was redesigned with the numerical calculation. The heating from the compressor were included in the air flow calculation. The inlet air velocity varies depending on the location of a heat exchanger, and also differs between heat exchangers. The inlet temperature of the heat exchanger is influenced by the compressor heating, but the velocity field is not influenced. HSPF improved by 6%, with the change of pass based on the numerical simulation. 5

R110, Page 7 REFERENCES Kim,C. M. et al., 2001, The experimental study on the comparison in performance of the system which used modulated compressors, Proceedings of the SAREK 2001 summer annual conference (III), pp. 1114-1120 Kim, C. M. et al, 2003, The experimental study on uniform distribution of oil at the air conditioning system using two compressor, J. of SAREK, Vol. no.2:p.103-108 Ryu, Y. H. et al 2002, Benchmark Performance Analysis of vapor compressor System with Capacity Modulation Compressor, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 14, No.2, pp 98-107 Song, C. G. et al, 2004, The Assessment of SEER Relating to Capacity Modulation in the Air Conditioner with Two Compressors, International Refrigeration and Air Conditioning Conference at Purdue, R111 Tassou, S. A. et al., 1981, Energy conservation throudgh the ues of capacity control in heat pumps, Junal of the Institue of energy, 30, pp. 30-35 ARI Standard 210/240, 2003, Unitary Air-conditioning and Air-source Heat Pump Equipment